Copies of this proposal may be purchased from:            BSR X3.221
Global Engineering, 2805 McGaw St, Irvine, CA 92714       X3T9.2/90-143
800-854-7179        714-261-1455





                  working draft proposed American National
                     Standard for Information Systems -

                            ATA (AT Attachment)

                         Rev 3.2  October 16, 1992




Secretariat

Computer and Business Equipment Manufacturers Association (CBEMA)

Abstract:  This standard defines an integrated bus interface between disk
drives and host processors. It provides a common point of attachment for
systems manufacturers, system integrators, and suppliers of intelligent
peripherals.


draft proposed American National Standard

This is a draft proposed American National Standard of Accredited Standards
Committee X3.  As such this is not a completed standard.  The X3T9 Technical
Committee may modify this document as a result of comments received during
public review and its approval as a standard.




POINTS OF CONTACT:

John B. Lohmeyer                              I. Dal Allan
Chairman X3T9.2                               Vice-Chairman X3T9.2
NCR                                           ENDL
1635 Aeroplaza Dr                             14426 Black Walnut Court
Colorado Springs  CO 80916                    Saratoga  CA 95070

719-596-5795 x362                             408-867-6630



An electronic copy of this document is available from the SCSI Bulletin Board
(719-574-0424).

This document has been prepared according to the style guide of the ISO
(International Organization of Standards).


If this document was printed in a 2-up form directly from the printer, NOTEs
had to be adjusted to fit into a half-page, which may have resulted in an
imperfect representation of the format within the NOTE. This is most likely to
occur if a series of NOTEs are mixed in without any line separation.




ATA was forwarded in August 1991 from X3T9.2 to X3T9 for further processing as
an American National Standard.  X3T9 authorized a letter ballot on forwarding
this document as a preliminary draft proposed American National Standard.

X3 authorized a Public Review of Rev 3.0 of the document as a draft proposed
American National Standard.

This revision reflects comments received during the 4-month Public Review, and
recommendations made by the ATA Working Group of X3T9.2. Amongst the technical
changes included herein that differ from the Rev 3.0 document are:

         NOP:
              Additional command

         Multiword DMA:
              Additional timing chart
              Additions to Identify Drive
              Additions to Set Features

         SFF 44-pin:
              Additional Annex

         LBA (Logical Block Addressing):
              Additional description
              Additions to Identify Drive
              Additions to Register descriptions

All changes from Rev 3.0 are marked in bold.

Foreword: This Foreword is not part of American National Standard X3.***-199x.

When the first IBM PC (Personal Computer) (tm) was introduced, there was no
hard disk capability for storage. Successive generations of product resulted
in the inclusion of a hard disk as the primary storage device. When the PC AT
(tm) was developed, a hard disk was the key to system performance, and the
controller interface became a de facto industry interface for the inclusion of
hard disks in PC ATs.

The price of desktop systems has declined rapidly because of the degree of
integration to reduce the number of components and interconnects required to
build a product. A natural outgrowth of this integration was the inclusion of
controller functionality into the hard disk.

In October 1988 a number of peripheral suppliers formed the Common Access
Method Committee to encourage an industry-wide effort to adopt a common
software interface to dispatch input/output requests to SCSI peripherals.
Although this was the primary objective, a secondary goal was to specify what
is known as the AT Attachment interface.

Suggestions for improvement of this standard will be welcome. They should be
sent to the Computer and Business Equipment Manufacturers Association, 311
First Street N.W., Suite 500, Washington, DC 20001.

This standard was processed and approved for submittal to ANSI by the
Accredited Standards Committee on Information Processing Systems, X3.
Committee approval of this standard does not necessarily imply that all
committee members voted for its approval. At the time it approved this
standard, the X3 Committee had the following members:

         X3 Committee list goes here:


Subcommittee X3T9 on I/O interfaces, which reviewed this standard, had the
following members:

         X3T9 Committee list goes here:




Task Group X3T9.2 on Lower-Level Interfaces, which completed the development
of this standard, had the following members:

         X3T9.2 Committee list goes here:



The initial development work on this standard was done by the CAM Committee.

The membership of the CAM Committee consisted of the following organizations:

 Adaptec               Data Technology          NCR
 AMD                   Eastman Kodak            Olivetti
 Apple                 Emulex                   Quantum
 AT&T Bell Labs        Fujitsu uElectronics     Scientific Micro Systems
 Caliper               Future Domain            Seagate
 Cambrian Systems      Hewlett Packard          Sony
 Cipher Data           IBM                      Storage Dimensions
 Cirrus Logic          Imprimis                 Sun Microsystems
 Columbia Data         Interactive Systems      Syquest Technology
 CompuAdd              JVC                      Sytron
 Conner Peripherals    LMS OSD                  Trantor
 Dell Computer         Maxtor                   Western Digital
 Digital Equipment     Micropolis
 DPT                   Miniscribe

                          TABLE OF CONTENTS

 1.          Scope                                                     1
 1.1         Description of Clauses                                    1

 2.          References                                                1
 3.          General Description                                       1
 3.1         Structure                                                 2

 4.          Definitions and Conventions                               2
 4.1         Definitions                                               2
 4.2         Conventions                                               3

 5.          Interface Cabling Requirements                            3
 5.1         Configuration                                             3
 5.2         Addressing Considerations                                 4
 5.3         DC Cable and Connector                                    5
 5.3.1       4-Pin Power                                               5
 5.3.2       3-Pin Power                                               5
 5.3.3       Device Grounding                                          6

 5.4         I/O Connector                                             6
 5.5         I/O Cable                                                 6

 6.          Physical Interface                                        7
 6.1         Signal Conventions                                        7
 6.2         Signal Summary                                            7
 6.3         Signal Descriptions                                       9
 6.3.1       CS1FX- (Drive chip Select 0)                              9
 6.3.2       CS3FX- (Drive chip Select 1)                              9
 6.3.3       DA0-2 (Drive Address Bus)                                 10
 6.3.4       DASP- (Drive Active/Drive 1 Present)                      10
 6.3.5       DD0-DD15 (Drive Data Bus)                                 10
 6.3.6       DIOR- (Drive I/O Read)                                    10
 6.3.7       DIOW- (Drive I/O Write)                                   10
 6.3.8       DMACK- (DMA Acknowledge) (Optional)                       10
 6.3.9       DMARQ (DMA Request) (Optional)                            11
 6.3.10      INTRQ (Drive Interrupt)                                   11
 6.3.11      IOCS16- (Drive 16-bit I/O)                                11
 6.3.12      IORDY (I/O Channel Ready) (Optional)                      12
 6.3.13      PDIAG- (Passed Diagnostics)                               12
 6.3.14      RESET- (Drive Reset)                                      12
 6.3.15      SPSYNC:CSEL (Spindle Synchronization/Cable Select)
             (Optional)                                                12
 6.3.15.1    SPSYNC (Spindle Synchronization) (Optional)               13
 6.3.15.2    CSEL (Cable Select) (Optional)                            13

 7.          Logical Interface                                         14
 7.1         General                                                   14
 7.1.1       Bit Conventions                                           14
 7.1.2       Environment                                               14

 7.2         I/O Register Descriptions                                 15
 7.2.1       Alternate Status Register                                 16
 7.2.2       Command Register                                          16
 7.2.3       Cylinder High Register                                    16
 7.2.4       Cylinder Low Register                                     17
 7.2.5       Data Register                                             17
 7.2.6       Device Control Register                                   17
 7.2.7       Drive Address Register                                    17
 7.2.8       Drive/Head Register                                       18
 7.2.9       Error Register                                            18
 7.2.10      Features Register                                         19
 7.2.11      Sector Count Register                                     19
 7.2.12      Sector Number Register                                    19
 7.2.13      Status Register                                           19

 8.          Programming Requirements                                  21
 8.1         Reset Response                                            21
 8.2         Translate Mode                                            22
 8.3         Power Conditions                                          22
 8.4         Error Posting                                             22

 9.          Command Descriptions                                      23
 9.1         Acknowledge Media Change (Removable)                      25
 9.2         Boot - Post-Boot (Removable)                              25
 9.3         Boot - Pre-Boot (Removable)                               25
 9.4         Check Power Mode                                          26
 9.5         Door Lock (Removable)                                     26
 9.6         Door Unlock (Removable)                                   26
 9.7         Execute Drive Diagnostic                                  26
 9.8         Format Track                                              27
 9.9         Identify Drive                                            28
 9.9.1       Word 1: Number of cylinders                               29
 9.9.2       Word 3: Number of heads                                   29
 9.9.3       Word 4: Number of unformatted bytes per track             29
 9.9.4       Word 5: Number of unformatted bytes per sector            30
 9.9.5       Word 6: Number of sectors per track                       30
 9.9.6       Word 10-19: Serial Number                                 30
 9.9.7       Word 20: Buffer Type                                      30
 9.9.8       Word 22: ECC bytes Available on Read/Write Long Commands  30
 9.9.9       Word 23-26: Firmware Revision                             30
 9.9.10      Word 27-46: Model Number                                  30
 9.9.11      Word 51:  PIO data transfer cycle timing mode             30
 9.9.12      Word 52:  DMA data transfer cycle timing mode             30
 9.9.13      Word 54:  Number of current cylinders                     31
 9.9.14      Word 55:  Number of current heads                         31
 9.9.15      Word 56:  Number of current sectors per track             31
 9.9.16      Word 57-58: Current capacity in sectors                   31
 9.9.17      Word 59: Multiple Sector Setting                          31
 9.9.18      Word 60-61: Total Number of User Addressable Sectors      31
 9.9.19      Word 62: Single Word DMA Transfer                         31
 9.9.20      Word 63: Multiword DMA Transfer                           31

 9.10        Idle                                                      31
 9.11        Idle Immediate                                            32
 9.12        Initialize Drive Parameters                               32
 9.13        NOP                                                       32
 9.14        Read Buffer                                               32
 9.15        Read DMA                                                  33
 9.16        Read Long                                                 33
 9.17        Read Multiple Command                                     33
 9.18        Read Sector(s)                                            34
 9.19        Read Verify Sector(s)                                     34
 9.20        Recalibrate                                               35
 9.21        Seek                                                      35
 9.22        Set Features                                              35
 9.23        Set Multiple Mode                                         36
 9.24        Sleep                                                     36
 9.25        Standby                                                   37
 9.26        Standby Immediate                                         37
 9.27        Write Buffer                                              37
 9.28        Write DMA                                                 37
 9.29        Write Long                                                37
 9.30        Write Multiple Command                                    38
 9.31        Write Same                                                38
 9.32        Write Sector(s)                                           39
 9.33        Write Verify                                              39

 10.         Protocol Overview                                         39
 10.1        PIO Data In Commands                                      40
 10.1.1      PIO Read Command                                          40
 10.1.2      PIO Read Aborted Command                                  40

 10.2        PIO Data Out Commands                                     40
 10.2.1      PIO Write Command                                         41
 10.2.2      PIO Write Aborted Command                                 41

 10.3        Non-Data Commands                                         41
 10.4        Miscellaneous Commands                                    42
 10.5        DMA Data Transfer Commands (Optional)                     42
 10.5.1      Normal DMA Transfer                                       43
 10.5.2      Aborted DMA Transfer                                      43
 10.5.3      Aborted DMA Command                                       43

 11.         Timing                                                    43
 11.1        Deskewing                                                 43
 11.2        Symbols                                                   43
 11.3        Terms                                                     44
 11.4        Data Transfers                                            45
 11.5        Power On and Hard Reset                                   48

                                  FIGURES

 FIGURE 5-1:  ATA INTERFACE TO EMBEDDED BUS PERIPHERALS                4
 FIGURE 5-2:  HOST BUS ADAPTER AND PERIPHERAL DEVICES                  4
 FIGURE 5-3:  ATA INTERFACE TO CONTROLLER AND PERIPHERAL DEVICES       4
 FIGURE 5-4:  40-PIN CONNECTOR MOUNTING                                6
 FIGURE 6-1:  Cable Select                                             14
 FIGURE 11-1:  PIO DATA TRANSFER TO/FROM DRIVE                         45
 FIGURE 11-2:  IORDY TIMING REQUIREMENTS                               46
 FIGURE 11-3:  SINGLE WORD DMA DATA TRANSFER                           46
 FIGURE 11-4:  MULTIWORD DMA DATA TRANSFER                             47
 FIGURE 11-5:  RESET SEQUENCE                                          48


                                  TABLES

 TABLE 5-1:  DC INTERFACE                                              5
 TABLE 5-2:  DC INTERFACE                                              5
 TABLE 5-3:  CABLE PARAMETERS                                          7
 TABLE 6-1:  INTERFACE SIGNALS                                         8
 TABLE 6-2:  INTERFACE SIGNALS DESCRIPTION                             9
 TABLE 7-1:  I/O PORT FUNCTIONS/SELECTION ADDRESSES                    16
 TABLE 8-1:  POWER CONDITIONS                                          22
 TABLE 8-2:  REGISTER CONTENTS                                         23
 TABLE 9-1:  COMMAND CODES AND PARAMETERS - Part 1 of 2                24
 TABLE 9-1:  COMMAND CODES AND PARAMETERS - Part 2 of 2                25

 TABLE 9-2:  DIAGNOSTIC CODES                                          27
 TABLE 9-4:  SET FEATURE REGISTER DEFINITIONS                          35
 TABLE C-1  SIGNAL ASSIGNMENTS FOR ATA                                 58


  Information Processing Systems --

  AT Attachment Interface


1. Scope

This standard defines the AT Attachment Interface.

The CAM Committee was formed in October, 1988 and the first working document
of the AT Attachment was introduced in March, 1989.

1.1  Description of Clauses

Clause 1 contains the Scope and Purpose.

Clause 2 contains Referenced and Related International Standards.

Clause 3 contains the General Description.

Clause 4 contains the Glossary.

Clause 5 contains the electrical and mechanical characteristics; covering the
interface cabling requirements of the DC, data cables and connectors.

Clause 6 contains the signal descriptions of the AT Attachment Interface.

Clause 7 contains descriptions of the registers of the AT Attachment
Interface.

Clause 8 describes the programming requirements of the AT Attachment
Interface.

Clause 9 contains descriptions of the commands of the AT Attachment Interface.

Clause 10 contains an overview of the protocol of the AT Attachment Interface.

Clause 11 contains the interface timing diagrams.

Annex A is informative.

Annex B is informative.

Annex C is informative.

2. References

None.

3.  General Description

The application environment for the AT Attachment Interface is any computer
which uses an AT Bus or 40-pin ATA interface.

The PC AT Bus (tm) is a widely used and implemented interface for which a
variety of peripherals have been manufactured. As a means of reducing size and
cost, a class of products has emerged which embed the controller functionality
in the drive. These new products utilize the AT Bus fixed disk interface
protocol, and a subset of the AT bus. Because of their compatibility with
existing AT hardware and software this interface quickly became a de facto
industry standard.

The purpose of the ATA standard is to define the de facto implementations.

Software in the Operating System dispatches I/O (Input/Output) requests via
the AT Bus to peripherals which respond to direct commands.

3.1  Structure

This standard relies upon specifications of the mechanical and electrical
characteristics of the AT Bus and a subset of the AT Bus specifically
developed for the direct attachment of peripherals.

Also defined are the methods by which commands are directed to peripherals,
the contents of registers and the method of data transfers.

4.  Definitions and Conventions

4.1 Definitions

For the purpose of this standard the following definitions apply:

4.1.1 ATA (AT Attachment):  ATA defines a compatible register set and a 40-pin
connector and its associated signals.

4.1.2 CHS (Cylinder-Head-Sector): This term defines the addressing mode of the
drive as being by physical address.

4.1.3 Data block: This term describes a data transfer, and is typically a
single sector, except when declared otherwise by use of the Set Multiple
command.

4.1.4 DMA (Direct Memory Access): A means of data transfer between
peripheral and host memory without processor intervention.

4.1.5 LBA (Logical Block Address): This term defines the addressing mode of
the drive as being by the linear mapping of sectors from 1 to n.

4.1.6 Optional:  This term describes features which are not required by the
standard. However, if any feature defined by the standard is implemented, it
shall be done in the same way as defined by the standard. Describing a feature
as optional in the text is done to assist the reader. If there is a conflict
between text and tables on a feature described as optional, the table shall be
accepted as being correct.

4.1.7 PIO (Programmed Input/Output): A means of data transfer that requires
the use of the host processor.

4.1.8 Reserved:  Where this term is used for bits, bytes and fields; the bits,
bytes and fields are set aside for future standardization, and shall be zero.

4.1.9 VU (Vendor Unique):  This term is used to describe bits, bytes,
fields, code values and features which are not described in this standard,
and may be used in a way that varies between vendors.

4.2  Conventions

Certain terms used herein are the proper names of signals. These are printed
in uppercase to avoid possible confusion with other uses of the same words;
e.g., ATTENTION. Any lowercase uses of these words have the normal American-
English meaning.

A number of conditions, commands, sequence parameters, events, English text,
states or similar terms are printed with the first letter of each word in
uppercase and the rest lowercase; e.g., In, Out, Request Status. Any lowercase
uses of these words have the normal American-English meaning.

The American convention of numbering is used i.e., the thousands and higher
multiples are separated by a comma and a period is used as the decimal point.
This is equivalent to the ISO convention of a space and comma.

  American:          0.6                      ISO:          0,6
                 1,000                                  1 000
             1,323,462.9                            1 323 462,9

5. Interface Cabling Requirements

5.1  Configuration

This standard provides the capability of operating on the AT Bus in a daisy
chained configuration with a second drive that operates in accordance with
these standards. One drive (selected as Drive 0) has been referred to as the
master in industry terms and the second (selected as Drive 1) has been
referred to as the slave (see Figure 5-3).

The designation as Drive 0 or Drive 1 may be made in a number of ways:

- a switch on the drive
- a jumper plug on the drive
- use of the Cable Select (CSEL) pin

Data is transferred in parallel (8 or 16 bits) either to or from host memory
to the drive's buffer under the direction of commands previously transferred
from the host. The drive performs all of the operations necessary to properly
write data to, or read data from, the disk media. Data read from the media is
stored in the drive's buffer pending transfer to the host memory and data is
transferred from the host memory to the drive's buffer to be written to the
media.

        +-----------------------------------------------------+
        |                                                     |
        |                       HOST                          |
        |                                                     |
        +---------------^-------------------------------------+
                        |       ATA Interface
                        | _____________________
                        |/                     |
                 +------v--+            +------v--+
                 | DRIVE 0 |            | DRIVE 1 |
                 +---------+            +---------+

        FIGURE 5-1:  ATA INTERFACE TO EMBEDDED BUS PERIPHERALS

        +-----------------------------------------------------+
        |                                                     |
        |                       HOST                          |
        |                                                     |
        +------+====== AT Bus ======+-------------------------+
               |                    |
               |       ADAPTER      |
               |                    |
               +--------^-----------+
                        |       ATA Interface
                        | _____________________
                        |/                     |
                 +------v--+            +------v--+
                 | DRIVE 0 |            | DRIVE 1 |
                 +---------+            +---------+

           FIGURE 5-2:  HOST BUS ADAPTER AND PERIPHERAL DEVICES

        +-----------------------------------------------------+
        |                                                     |
        |                       HOST                          |
        |                                                     |
        +---------------^-------------------------------------+
                        |       ATA Interface
                 +------v-----+
                 |            |
                 | CONTROLLER |
                 |            |
                 +-^----^---^-+
                   |    |   |__________________   Device Interface
                   | ___|_________________     |  e.g. ESDI, SCSI
                   |/   |                 |    |
                 +-v----v--+            +-v----v--+
                 |  DRIVE  |            |  DRIVE  |
                 +---------+            +---------+

     FIGURE 5-3:  ATA INTERFACE TO CONTROLLER AND PERIPHERAL DEVICES

5.2  Addressing Considerations

In traditional controller operation, only the selected controller receives
commands from the host following selection. In this standard, the register
contents go to both drives (and their embedded controllers). The host
discriminates between the two by using the DRV bit in the Drive/Head Register.

5.3  DC Cable and Connector

The drive receives DC power through a 4-pin or a low-power application 3-pin
connector.

A drive designed for 3.3V applications may be plugged into a receptacle
designed to accept a drive designed for 5V applications, with 12V lines for
additional power. It is not required that the drive operate, but it is
recommended that precautions be taken to prevent damage to the drive.

A drive designed for 5V applications may be plugged into a receptacle designed
to accept a drive designed for 3.3V applications, with 5V lines for additional
power. It is not anticipated that damage could occur to the drive, but it is
likely to fail in an undetermined manner.

5.3.1  4-Pin Power

The pin assignments are shown in Table 5-1. Recommended part numbers for the
mating connector to 18AWG cable are shown below, but equivalent parts may be
used.

    Connector (4 Pin)          AMP 1-480424-0 or equivalent.
    Contacts (Loose Piece)     AMP 60619-4 or equivalent.
    Contacts (Strip)           AMP 61117-4 or equivalent.

                         TABLE 5-1:  DC INTERFACE
                 +------------------------+------------+
                 | POWER LINE DESIGNATION | PIN NUMBER |
                 +------------------------+------------+
                 |      +12V              |    1-01    |
                 |      +12V RETURN       |    1-02    |
                 |      +5V RETURN        |    1-03    |
                 |      +5V               |    1-04    |
                 +------------------------+------------+

5.3.2  3-Pin Power

The pin assignments are shown in Table 5-2. Recommended part numbers for the
mating connector to 18AWG cable are shown below, but equivalent parts may be
used.

    Connector (3 Pin)          Molex 5484 39-27-0032 or equivalent.

                         TABLE 5-2:  DC INTERFACE
                 +------------------------+------------+
                 | POWER LINE DESIGNATION | PIN NUMBER |
                 +------------+-----------+------------+
                 |    +5V     |   +3.3V   |    1-01    |
                 |    +12V    |   +5V     |    1-02    |
                 |   Ground   |  Ground   |    1-03    |
                 +------------+-----------+------------+

5.3.3  Device Grounding

System ground may be connected to a "quick-connect" terminal equivalent to:

    Drive Connector Terminal   AMP 61664-1 or equivalent.
    Cable Connector Terminal   AMP 62137-2 or equivalent.

Provision for tying the DC Logic ground and the chassis ground together or for
separating these two ground planes is vendor specific.

5.4  I/O Connector

The I/O connector is a 40-pin connector as shown in Figure 5-4, with pin
assignments as shown in Table 6-1.

The connector should be keyed to prevent the possibility of installing it
upside down. A key is provided by the removal of Pin 20. The corresponding pin
on the cable connector should be plugged.

The pin locations are governed by the cable plug, not the receptacle. The way
in which the receptacle is mounted on the Printed Circuit Board affects the
pin positions, and pin 1 should remain in the same relative position. This
means the pin numbers of the receptacle may not reflect the conductor number
of the plug. The header receptacle is not polarized, and all the signals are
relative to Pin 20, which is keyed.

By using the plug positions as primary, a straight cable can connect drives.
As shown in Figure 5-4, conductor 1 on pin 1 of the plug has to be in the
same relative position no matter what the receptacle numbering looks like.
If receptacle numbering was followed, the cable would have to twist 180
degrees between a drive with top-mounted receptacles, and a drive with
bottom-mounted receptacles.

       +-----------------------+
       |                      1|
       |40         20         2|
     ==+==== Circuit Board ====+==       ==+==== Circuit Board ====+==
                                           |                      1|
                                           |40         20         2|
                                           +-----------------------+
                  FIGURE 5-4:  40-PIN CONNECTOR MOUNTING

Recommended part numbers for the mating connector are shown below, but
equivalent parts may be used.

    Connector (40 Pin)             3M 3417-7000 or equivalent.
    Strain relief                  3M 3448-2040 or equivalent.
    Flat Cable (Stranded 28 AWG)   3M 3365-40 or equivalent.
    Flat Cable (Stranded 28 AWG)   3M 3517-40 (Shielded) or equivalent.

5.5  I/O Cable

The cable specifications affect system integrity and the maximum length that
can be supported in any application.

                       TABLE 5-3:  CABLE PARAMETERS
       +--------------------------------------------+------+--------+
       | Cable length of 0.46m (18 inches) *        |  Min |   Max  |
       +--------------------------------------------+------+--------+
       | Driver IoL Sink Current for 5V operation   | 12mA |        |
       | Driver IoL Sink Current for 3.3V operation |  8mA |        |
       | Driver IoH Source Current                  |      | -400uA |
       | Cable Capacitive Loading                   |      |  200pF |
       +--------------------------------------------+------+--------+
         * This distance may be exceeded in circumstances where the
        characteristics of both ends of the cable can be controlled.

6.  Physical Interface

6.1  Signal Conventions

Signal names are shown in all upper case letters. Signals can be asserted
(active, true) in either a high (more positive voltage) or low (less positive
voltage) state. A dash character (-) at the beginning or end of a signal name
indicates it is asserted at the low level (active low). No dash or a plus
character (+) at the beginning or end of a signal name indicates it is
asserted high (active high). An asserted signal may be driven high or low by
an active circuit, or it may be allowed to be pulled to the correct state by
the bias circuitry.

Control signals that are asserted for one function when high and asserted for
another function when low are named with the asserted high function name
followed by a slash character (/), and the asserted low function name followed
with a dash (-) e.g. BITENA/BITCLR- enables a bit when high and clears a bit
when low. All signals are TTL compatible unless otherwise noted. Negated means
that the signal is driven by an active circuit to the state opposite to the
asserted state (inactive, or false) or may be simply released (in which case
the bias circuitry pulls it inactive, or false), at the option of the
implementor.

Control signals that may be used for two mutually exclusive functions are
identified with their two names separated by a colon e.g. SPSYNC:CSEL can be
used for either the Spindle Sync or the Cable Select functions.

6.2  Signal Summary

The physical interface consists of single ended TTL compatible receivers and
drivers communicating through a 40-conductor flat ribbon nonshielded cable
using an asynchronous interface protocol. The pin numbers and signal names
are shown in Table 6-1. Reserved signals shall be left unconnected.

                      TABLE 6-1:  INTERFACE SIGNALS
+----------------------------------+                         +-----------+
|         HOST  I/O                |                         | DRIVE I/O |
|         CONNECTOR                |                         | CONNECTOR |
|                                  |                         |           |
| HOST RESET                     1 | -----  RESET-  -------->| 1         |
|                                2 | -----  Ground  -------- | 2         |
| HOST DATA BUS BIT 7            3 |<-----  DD7  ----------->| 3         |
| HOST DATA BUS BIT 8            4 |<-----  DD8  ----------->| 4         |
| HOST DATA BUS BIT 6            5 |<-----  DD6  ----------->| 5         |
| HOST DATA BUS BIT 9            6 |<-----  DD9  ----------->| 6         |
| HOST DATA BUS BIT 5            7 |<-----  DD5  ----------->| 7         |
| HOST DATA BUS BIT 10           8 |<-----  DD10  ---------->| 8         |
| HOST DATA BUS BIT 4            9 |<-----  DD4  ----------->| 9         |
| HOST DATA BUS BIT 11          10 |<-----  DD11  ---------->| 10        |
| HOST DATA BUS BIT 3           11 |<-----  DD3  ----------->| 11        |
| HOST DATA BUS BIT 12          12 |<-----  DD12  ---------->| 12        |
| HOST DATA BUS BIT 2           13 |<-----  DD2  ----------->| 13        |
| HOST DATA BUS BIT 13          14 |<-----  DD13  ---------->| 14        |
| HOST DATA BUS BIT 1           15 |<-----  DD1  ----------->| 15        |
| HOST DATA BUS BIT 14          16 |<-----  DD14  ---------->| 16        |
| HOST DATA BUS BIT 0           17 |<-----  DD0  ----------->| 17        |
| HOST DATA BUS BIT 15          18 |<-----  DD15  ---------->| 18        |
|                               19 | -----  Ground  -------- | 19        |
|                               20 | -----  (keypin)  ------ | 20        |
| DMA REQUEST                   21 |<-----  DMARQ  --------- | 21        |
|                               22 | -----  Ground  -------- | 22        |
| HOST I/O WRITE                23 | -----  DIOW-  --------->| 23        |
|                               24 | -----  Ground  -------- | 24        |
| HOST I/O READ                 25 | -----  DIOR-  --------->| 25        |
|                               26 | -----  Ground  -------- | 26        |
| I/O CHANNEL READY             27 |<-----  IORDY  --------- | 27        |
| SPINDLE SYNC or CABLE SELECT  28 |*---- SPSYNC:CSEL  -----*| 28        |
| DMA ACKNOWLEDGE               29 | -----  DMACK-  -------->| 29        |
|                               30 | -----  Ground  -------- | 30        |
| HOST INTERRUPT REQUEST        31 |<-----  INTRQ  --------- | 31        |
| HOST 16 BIT I/O               32 |<-----  IOCS16-  ------- | 32        |
| HOST ADDRESS BUS BIT 1        33 | -----  DA1  ----------->| 33        |
| PASSED DIAGNOSTICS            34 |*-----  PDIAG-  --------*| 34        |
| HOST ADDRESS BUS BIT 0        35 | -----  DAO  ----------->| 35        |
| HOST ADDRESS BUS BIT 2        36 | -----  DA2  ----------->| 36        |
| HOST CHIP SELECT 0            37 | -----  CS1FX-  -------->| 37        |
| HOST CHIP SELECT 1            38 | -----  CS3FX-  -------->| 38        |
| DRIVE ACTIVE/DRIVE 1 PRESENT  39 |<-----  DASP-  ---------*| 39        |
|                               40 | -----  Ground  -------- | 40        |
+----------------------------------+                         +-----------+

                    * Drive Intercommunication Signals

      +---HOST---+       +-Drive 0-+                    +-Drive 1-+
      |       28 | ----->| 28   28 |<-- SPSYNC:CSEL  -->| 28      |
      |       34 | ----- | 34   34 |<----- PDIAG-  ---- | 34      |
      |       39 |<----- | 39   39 |<----- DASP-  ----- | 39      |
      +----------+       +---------+                    +---------+

6.3  Signal Descriptions

The interface signals and pins are described in more detail than shown in
Table 6-1. The signals are listed according to function, rather than in
numerical connector pin order. Table 6-2 lists signal name mnemonic, connector
pin number, whether input to (I) or output from (O) the drive, and full signal
name.

                TABLE 6-2:  INTERFACE SIGNALS DESCRIPTION
+--------+----+-----+
| Signal | Pin| I/O |
+--------+----+-----+-----------------------------------------------------+
| CS1FX- | 37 |  I  | Drive chip Select 0                                 |
| CS3FX- | 38 |  I  | Drive chip Select 1                                 |
| DA0    | 35 |  I  | Drive Address Bus - Bit 0                           |
| DA1    | 33 |  I  |                   - Bit 1                           |
| DA2    | 36 |  I  |                   - Bit 2                           |
| DASP-  | 39 | I/O | Drive Active/Drive 1 Present                        |
| DD0    | 17 | I/O | Drive Data Bus - Bit 0                              |
| DD1    | 15 | I/O |                - Bit 1                              |
| DD2    | 13 | I/O |                - Bit 2                              |
| DD3    | 11 | I/O |                - Bit 3                              |
| DD4    |  9 | I/O |                - Bit 4                              |
| DD5    |  7 | I/O |                - Bit 5                              |
| DD6    |  5 | I/O |                - Bit 6                              |
| DD7    |  3 | I/O |                - Bit 7                              |
| DD8    |  4 | I/O |                - Bit 8                              |
| DD9    |  6 | I/O |                - Bit 9                              |
| DD10   |  8 | I/O |                - Bit 10                             |
| DD11   | 10 | I/O |                - Bit 11                             |
| DD12   | 12 | I/O |                - Bit 12                             |
| DD13   | 14 | I/O |                - Bit 13                             |
| DD14   | 16 | I/O |                - Bit 14                             |
| DD15   | 18 | I/O |                - Bit 15                             |
| DIOR-  | 25 |  I  | Drive I/O Read                                      |
| DIOW-  | 23 |  I  | Drive I/O Write                                     |
| DMACK- | 29 |  I  | DMA Acknowledge                                     |
| DMARQ  | 21 |  O  | DMA Request                                         |
| INTRQ  | 31 |  O  | Drive Interrupt                                     |
| IOCS16-| 32 |  O  | Drive 16-bit I/O                                    |
| IORDY  | 27 |  O  | I/O Channel Ready                                   |
| PDIAG- | 34 | I/O | Passed Diagnostics                                  |
| RESET- |  1 |  I  | Drive Reset                                         |
| SPSYNC:| 28 |  -  | Spindle Sync                                        |
| CSEL   | 28 |  -  | Cable Select                                        |
| keypin | 20 |  -  | Pin used for keying the interface connector.        |
+--------+----+-----+-----------------------------------------------------+

6.3.1 CS1FX- (Drive chip Select 0)

This is the chip select signal decoded from the host address bus used to
select the Command Block Registers.

6.3.2 CS3FX- (Drive chip Select 1)

This is the chip select signal decoded from the host address bus used to
select the Control Block Registers.

6.3.3 DA0-2 (Drive Address Bus)

This is the 3-bit binary coded address asserted by the host to access a
register or data port in the drive.

6.3.4 DASP- (Drive Active/Drive 1 Present)

This is a time-multiplexed signal which indicates that a drive is active, or
that Drive 1 is present. This signal shall be an open collector output and
each drive shall have a 10K ohm pull-up resistor.

During power on initialization or after RESET- is negated, DASP- shall be
asserted by Drive 1 within 400 msec to indicate that Drive 1 is present.

Drive 0 shall allow up to 450 msec for Drive 1 to assert DASP-. If Drive 1 is
not present, Drive 0 may assert DASP- to drive an activity LED.

DASP- shall be negated following acceptance of the first valid command by
Drive 1 or after 31 seconds, whichever comes first.

Any time after negation of DASP-, either drive may assert DASP- to indicate
that a drive is active.

 NOTE: Prior to the development of this standard, products were introduced
       which did not time multiplex DASP-. Some used two jumpers to indicate
       to Drive 0 whether Drive 1 was present. If such a drive is jumpered to
       indicate Drive 1 is present it should work successfully with a Drive 1
       which complies with this standard. If installed as Drive 1, such a
       drive may not work successfully because it may not assert DASP- for a
       long enough period to be recognized. However, it would assert DASP-
       to indicate that the drive is active.

6.3.5 DD0-DD15 (Drive Data Bus)

This is an 8- or 16-bit bidirectional data bus between the host and the drive.
The lower 8 bits are used for 8-bit transfers e.g. registers, ECC bytes and,
if the drive supports the Features Register capability to enable 8-bit-only
data transfers (see 9.21).

6.3.6 DIOR- (Drive I/O Read)

This is the Read strobe signal. The falling edge of DIOR- enables data from a
register or the data port of the drive onto the host data bus, DD0-DD7 or DD0-
DD15. The rising edge of DIOR- latches data at the host.

6.3.7 DIOW- (Drive I/O Write)

This is the Write strobe signal. The rising edge of DIOW- clocks data from the
host data bus, DD0-DD7 or DD0-DD15, into a register or the data port of the
drive.

6.3.8 DMACK- (DMA Acknowledge) (Optional)

This signal shall be used by the host in response to DMARQ to either
acknowledge that data has been accepted, or that data is available.

6.3.9 DMARQ (DMA Request) (Optional)

This signal, used for DMA data transfers between host and drive, shall be
asserted by the drive when it is ready to transfer data to or from the host.
The direction of data transfer is controlled by DIOR- and DIOW-. This signal
is used in a handshake manner with DMACK- i.e. the drive shall wait until the
host asserts DMACK- before negating DMARQ, and re-asserting DMARQ if there is
more data to transfer.

When a DMA operation is enabled, IOCS16-, CS1FX- and CS3FX- shall not be
asserted and transfers shall be 16-bits wide.

 NOTE: ATA products with DMA capability require a pull-down resistor on this
       signal to prevent spurious data transfers. This resistor may affect
       driver requirements for drives sharing this signal in systems with
       unbuffered ATA signals.

6.3.10 INTRQ (Drive Interrupt)

This signal is used to interrupt the host system. INTRQ is asserted only when
the drive has a pending interrupt, the drive is selected, and the host has
cleared nIEN in the Device Control Register. If nIEN=1, or the drive is not
selected, this output is in a high impedance state, regardless of the presence
or absence of a pending interrupt.

INTRQ shall be negated by:

- assertion of RESET- or
- the setting of SRST of the Device Control Register, or
- the host writing the Command Register or
- the host reading the Status Register

 NOTE: Some drives may negate INTRQ on a PIO data transfer completion, except
       on a single sector read or on the last sector of a multi-sector read.

On PIO transfers, INTRQ is asserted at the beginning of each data block to be
transferred. A data block is typically a single sector, except when
declared otherwise by use of the Set Multiple command. An exception occurs on
Format Track, Write Sector(s), Write Buffer and Write Long commands - INTRQ
shall not be asserted at the beginning of the first data block to be
transferred.

On DMA transfers, INTRQ is asserted only once, after the command has
completed.

6.3.11 IOCS16- (Drive 16-bit I/O)

Except for DMA transfers, IOCS16- indicates to the host system that the 16-bit
data port has been addressed and that the drive is prepared to send or receive
a 16-bit data word. This shall be an open collector output.

- When transferring in PIO mode, If IOCS16- is not asserted, transfers shall
  be 8-bit using DD0-7.
- When transferring in PIO mode, if IOCS16- is asserted, transfers shall be
  16-bit using DD0-15.
  for 16-bit data transfers.
- When transferring in DMA mode, the host shall use a 16-bit DMA channel and
  IOCS16- shall not be asserted.

6.3.12 IORDY (I/O Channel Ready) (Optional)

This signal is negated to extend the host transfer cycle of any host register
access (Read or Write) when the drive is not ready to respond to a data
transfer request. When IORDY is not negated, IORDY shall be in a high
impedance state.

6.3.13 PDIAG- (Passed Diagnostics)

This signal shall be asserted by Drive 1 to indicate to Drive 0 that it has
completed diagnostics. A 10K ohm pull-up resistor shall be used on this signal
by each drive.

Following a power on reset, software reset or RESET-, Drive 1 shall negate
PDIAG- within 1 msec (to indicate to Drive 0 that it is busy). Drive 1 shall
then assert PDIAG- within 30 seconds to indicate that it is no longer busy,
and is able to provide status. After the assertion of PDIAG-, Drive 1 may be
unable to accept commands until it has finished its reset procedure and is
Ready (DRDY=1).

Following the receipt of a valid Execute Drive Diagnostics command, Drive
1 shall negate PDIAG- within 1 msec to indicate to Drive 0 that it is busy
and has not yet passed its drive diagnostics. If Drive 1 is present then
Drive 0 shall wait for up to 5 seconds from the receipt of a valid Execute
Drive Diagnostics command for Drive 1 to assert PDIAG-. Drive 1 should
clear BSY before asserting PDIAG-, as PDIAG- is used to indicate that
Drive 1 has passed its diagnostics and is ready to post status.

If DASP- was not asserted by Drive 1 during reset initialization, Drive 0
shall post its own status immediately after it completes diagnostics, and
clear the Drive 1 Status Register to 00h. Drive 0 may be unable to accept
commands until it has finished its reset procedure and is Ready (DRDY=1).

6.3.14 RESET- (Drive Reset)

This signal from the host system shall be asserted for at least 25 usec after
voltage levels have stabilized during power on and negated thereafter unless
some event requires that the drive(s) be reset following power on.

6.3.15  SPSYNC:CSEL (Spindle Synchronization/Cable Select) (Optional)

This signal shall have a 10K ohm pull-up resistor.

This is a dual purpose signal and either or both functions may be implemented.
If both functions are implemented then they cannot be active concurrently: the
choice as to which is active is made by a vendor-defined switch.

All drives connected to the same cable should have the same function active at
the same time. If SPSYNC and CSEL are mixed on the same cable, then drive
behaviour is undefined.

Prior to the introduction of this standard, this signal was defined as DALE
(Drive Address Latch Enable), and used for an address valid indication from
the host system. If used, the host address and chip selects, DAO through DA2,
CS1FX-, and CS3FX- were valid at the negation of this signal and remained
valid while DALE was negated, therefore, the drive did not need to latch these
signals with DALE.

6.3.15.1  SPSYNC (Spindle Synchronization) (Optional)

This signal may be either input or output to the drive depending on a vendor-
defined switch. If a drive is set to Master the signal is output, and if a
drive is set to slave the signal is input.

There is no requirement that each drive implementation be plug-compatible to
the extent that a multiple vendor drive subsystem be operable. Mix and match
of different manufacturers drives is unlikely because rpm, sync fields, sync
bytes etc need to be virtually identical. However, if drives are designed to
match the following recommendation, controllers can operate drives with a
single implementation.

There can only be one master drive at a time in a configuration. The host or
the drive designated as master can generate SPSYNC at least once per rotation,
but may be at a higher frequency.

SPSYNC received by a drive is used as the synchronization signal to lock the
spindles in step. The time to achieve synchronization varies, and is indicated
by the drive setting DRDY i.e. if the drive does not achieve synchronization
following power on or a reset, it shall not set DRDY.

A master drive or the host generates SPSYNC and transmits it.

A slave drive does not generate SPSYNC and is responsible to synchronize its
index to SPSYNC.

If a drive does not support synchronization, it shall ignore SPSYNC.

In the event that a drive previously synchronized loses synchronization, but
is otherwise operational, it does not clear DRDY.

6.3.15.2  CSEL (Cable Select) (Optional)

The drive is configured as either Drive 0 or Drive 1 depending upon the value
of CSEL:

- If CSEL is grounded then the drive address is 0
- If CSEL is open then the drive address is 1

Special cabling can be used by the system manufacturer to selectively ground
CSEL e.g. CSEL of Drive 0 is connected to the CSEL conductor in the cable, and
is grounded, thus allowing the drive to recognize itself as Drive 0. CSEL of
Drive 1 is not connected to CSEL because the conductor is removed, thus the
drive can recognize itself as Drive 1.

             ______ CSEL Conductor _________________________
            |                            |                Open
            |Ground                      |                  |
         +------+                   +---------+        +---------+
         | Host |                   | Drive 0 |        | Drive 1 |
         +------+                   +---------+        +---------+

             ______ CSEL Conductor _________________________
            |                          Open                 |
            |Ground                      |                  |
         +------+                   +---------+        +---------+
         | Host |                   | Drive 1 |        | Drive 0 |
         +------+                   +---------+        +---------+

                         FIGURE 6-1:  Cable Select

7.  Logical Interface

7.1  General

7.1.1  Bit Conventions

Bit names are shown in all upper case letters except where a lower case n
precedes a bit name. This indicates that when nBIT=0 (bit is zero) the action
is true and when nBIT=1 (bit is one) the action is false. If there is no
preceding n, then when BIT=1 it is true, and when BIT=0 it is false.

A bit can be set to one or cleared to zero and polarity influences whether it
is to be interpreted as true or false:

         True      BIT=1       nBIT=0
         False     BIT=0       nBIT=1

7.1.2  Environment

The drives using this interface shall be programmed by the host computer to
perform commands and return status to the host at command completion. When two
drives are daisy chained on the interface, commands are written in parallel to
both drives, and for all except the Execute Diagnostics command, only the
selected drive executes the command. On an Execute Diagnostics command
addressed to Drive 0, both drives shall execute the command, and Drive 1 shall
post its status to Drive 0 via PDIAG-.

Drives are selected by the DRV bit in the Drive/Head Register (see 7.2.8), and
by a jumper or switch on the drive designating it as either a Drive 0 or as
Drive 1. When DRV=0, Drive 0 is selected. When DRV=1, Drive 1 is selected.
When drives are daisy chained, one shall be set as Drive 0 and the other as
Drive 1. When a single drive is attached to the interface it shall be set as
Drive 0.

Prior to the adoption of this standard, some drives may have provided jumpers
to indicate Drive 0 with no Drive 1 present, or Drive 0 with Drive 1 present.

Throughout this document, drive selection always refers to the state of the
DRV bit, the position of the Drive 0/Drive 1 jumper or switch, or use of the
CSEL pin.

A drive can operate in either of two addressing modes, CHS or LBA, on a
command by command basis. A drive which can support LBA mode indicates this in
the Identify Drive Information. If the host selects LBA mode in the Drive/Head
register, Sector Number, Cylinder Low, Cylinder High and HS3-HS0 of the
Drive/Head Register contains the zero based-LBA.

In LBA mode, the sectors on the drive are assumed to be linearly mapped with
an Inital definition of:

       LBA 0 = Cylinder 0/Head 0/Sector 1.

Irrespective of translate mode geometry set by the host, the LBA address of a
given sector does not change:

 LBA = [ (Cylinder * No of Heads + Heads) * Sectors/Track ] + (Sector-1)

7.2  I/O Register Descriptions

Communication to or from the drive is through an I/O Register that routes the
input or output data to or from registers (selected) by a code on signals from
the host (CS1FX-, CS3FX-, DA2, DA1, DA0, DIOR- and DIOW-).

The Command Block Registers are used for sending commands to the drive or
posting status from the drive.

The Control Block Registers are used for drive control and to post alternate
status.

Table 7-1 lists these registers and the addresses that select them.

Logic conventions are:   A = signal asserted
                        N = signal negated
                        x = does not matter which it is

           TABLE 7-1:  I/O PORT FUNCTIONS/SELECTION ADDRESSES
+-------------------------------+-----------------------------------------+
|         Addresses             |                 Functions               |
|CS1FX-|CS3FX-| DA2 | DA1 | DA0 |    READ (DIOR-)     |   WRITE (DIOW-)   |
+------+------+-----+-----+-----+---------------------+-------------------+
|                                        Control Block Registers          |
+------+------+-----+-----+-----+---------------------+-------------------+
|  N   |  N   |  x  |  x  |  x  | Data Bus High Imped | Not used          |
|  N   |  A   |  0  |  x  |  X  | Data Bus High Imped | Not used          |
|  N   |  A   |  1  |  0  |  x  | Data Bus High Imped | Not used          |
|  N   |  A   |  1  |  1  |  0  | Alternate Status    | Device Control    |
|  N   |  A   |  1  |  1  |  1  | Drive Address       | Not used          |
+------+------+-----+-----+-----+---------------------+-------------------+
|                                        Command Block Registers          |
+------+------+-----+-----+-----+---------------------+-------------------+
|  A   |  N   |  0  |  0  |  0  | Data                | Data              |
|  A   |  N   |  0  |  0  |  1  | Error Register      | Features          |
|  A   |  N   |  0  |  1  |  0  | Sector Count        | Sector Count      |
|  A   |  N   |  0  |  1  |  1  | Sector Number       | Sector Number     |
|  A   |  N   |  0  |  1  |  1  | * LBA Bits  0- 7    | * LBA Bits  0- 7  |
|  A   |  N   |  1  |  0  |  0  | Cylinder Low        | Cylinder Low      |
|  A   |  N   |  1  |  0  |  0  | * LBA Bits  8-15    | * LBA Bits  8-15  |
|  A   |  N   |  1  |  0  |  1  | Cylinder High       | Cylinder High     |
|  A   |  N   |  1  |  0  |  1  | * LBA Bits 16-23    | * LBA Bits 16-23  |
|  A   |  N   |  1  |  1  |  0  | Drive/Head          | Drive/Head        |
|  A   |  N   |  1  |  1  |  0  | * LBA Bits 24-27    | * LBA Bits 24-27  |
|  A   |  N   |  1  |  1  |  1  | Status              | Command           |
|  A   |  A   |  x  |  x  |  x  | Invalid Address     | Invalid Address   |
+------+------+-----+-----+-----+---------------------+-------------------+
                     * Mapping of registers in LBA Mode

7.2.1  Alternate Status Register

This register contains the same information as the Status Register in the
command block. The only difference being that reading this register does not
imply interrupt acknowledge or clear a pending interrupt.

        7       6       5       4       3       2       1       0
    +-------+-------+-------+-------+-------+-------+-------+-------+
    |  BSY  | DRDY  |  DWF  |  DSC  |  DRQ  | CORR  |  IDX  |  ERR  |
    +-------+-------+-------+-------+-------+-------+-------+-------+

See 7.2.13 for definitions of the bits in this register.

7.2.2  Command Register

This register contains the command code being sent to the drive. Command
execution begins immediately after this register is written. The executable
commands, the command codes, and the necessary parameters for each command are
listed in Table 9-1.

7.2.3  Cylinder High Register

This register contains the high order bits of the starting cylinder address
for any disk access. At the end of the command, this register is updated to
reflect the current cylinder number. The most significant bits of the cylinder
address shall be loaded into the cylinder high Register.

In LBA Mode this register contains Bits 16-23. At the end of the command, this
register is updated to reflect the current LBA Bits 16-23.

 NOTE: Prior to the introduction of this standard, only the lower 2 bits of
       this register were valid, limiting cylinder address to 10 bits i.e.
       1,024 cylinders.

7.2.4  Cylinder Low Register

This register contains the low order 8 bits of the starting cylinder address
for any disk access. At the end of the command, this register is updated to
reflect the current cylinder number.

In LBA Mode this register contains Bits 8-15. At the end of the command, this
register is updated to reflect the current LBA Bits 8-15.

7.2.5  Data Register

This 16-bit register is used to transfer data blocks between the device data
buffer and the host. It is also the register through which sector information
is transferred on a Format Track command. Data transfers may be either PIO or
DMA.

7.2.6  Device Control Register

The bits in this register are as follows:

        7       6       5       4       3       2       1       0
    +-------+-------+-------+-------+-------+-------+-------+-------+
    |   x   |   x   |   x   |   x   |   1   | SRST  |  nIEN |   0   |
    +-------+-------+-------+-------+-------+-------+-------+-------+

- SRST is the host software reset bit. The drive is held reset when this bit
  is set. If two disk drives are daisy chained on the interface, this bit
  resets both simultaneously. Drive 1 is not required to execute the DASP-
  handshake procedure.
- nIEN is the enable bit for the drive interrupt to the host. When nIEN=0,
  and the drive is selected, INTRQ shall be enabled through a tri-state
  buffer. When nIEN=1, or the drive is not selected, the INTRQ signal shall
  be in a high impedance state.

7.2.7  Drive Address Register

This register contains the inverted drive select and head select addresses of
the currently selected drive. The bits in this register are as follows:

        7       6       5       4       3       2       1       0
    +-------+-------+-------+-------+-------+-------+-------+-------+
    |  HiZ  |  nWTG |  nHS3 |  nHS2 |  nHS1 |  nHS0 |  nDS1 |  nDS0 |
    +-------+-------+-------+-------+-------+-------+-------+-------+

- HiZ shall always be in a high impedance state.
- nWTG is the Write Gate bit. When writing to the disk drive is in progress,
  nWTG=0.
- nHS3 through nHS0 are the one's complement of the binary coded address of
  the currently selected head. For example, if nHS3 through nHS0 are 1100b,
  respectively, head 3 is selected. nHS3 is the most significant bit.
- nDS1 is the drive select bit for drive 1. When drive 1 is selected and
  active, nDS1=0.
- nDS0 is the drive select bit for drive 0. When drive 0 is selected and
  active, nDS0=0.

 NOTE: Care should be used when interpreting these bits, as they do not
       always represent the expected status of drive operations at the
       instant the status was put into this register. This is because of the
       use of cacheing, translate mode and the Drive 0/Drive 1 concept with
       each drive having its own embedded controller.

7.2.8  Drive/Head Register

This register contains the drive and head numbers. The contents of this
register define the number of heads minus 1, when executing an Initialize
Drive Parameters command.

        7       6       5       4       3       2       1       0
    +-------+-------+-------+-------+-------+-------+-------+-------+
    |   1   |   L   |   1   |  DRV  |  HS3  |  HS2  |  HS1  |  HS0  |
    +-------+-------+-------+-------+-------+-------+-------+-------+

- L is the binary encoded address mode select. When L=0, addressing is by CHS
  mode. When L=1, addressing is by LBA mode.
- DRV is the binary encoded drive select number. When DRV=0, Drive 0 is
  selected. When DRV=1, Drive 1 is selected.
- If L=0, HS3 through HS0 contain the binary coded address of the head to be
  selected e.g. if HS3 through HS0 are 0011b, respectively, head 3 will be
  selected. HS3 is the most significant bit. At command completion, these
  bits are updated to reflect the currently selected head.
  If L=1, HS3 through HS0 contain bits 24-27 of the LBA. At command
  completion, these bits are updated to reflect the current LBA bits 24-27.

7.2.9  Error Register

This register contains status from the last command executed by the drive or a
Diagnostic Code.

At the completion of any command except Execute Drive Diagnostic, the contents
of this register are valid when ERR=1 in the Status Register.

Following a power on, a reset, or completion of an Execute Drive Diagnostic
command, this register contains a Diagnostic Code (see Table 9-2).

        7       6       5       4       3       2       1       0
    +-------+-------+-------+-------+-------+-------+-------+-------+
    | BBK   |  UNC  |  MC   |  IDNF |  MCR  | ABRT  | TK0NF |  AMNF |
    +-------+-------+-------+-------+-------+-------+-------+-------+

- BBK (Bad Block Detected) indicates a bad block mark was detected in the
  requested sector's ID field.
- UNC (Uncorrectable Data Error) indicates an uncorrectable data error has
  been encountered.
- MC (Media Changed) indicates that the removable media has been changed i.e.
  there has been a change in the ability to access the media.
- IDNF (ID Not Found) indicates the requested sector's ID field could not be
  found.
- ABRT (Aborted Command) indicates the requested command has been aborted due
  to a drive status error (Not Ready, Write Fault, etc.) or because the
  command code is invalid.
- MCR (Media Change Requested) indicates that the release latch on a
  removable media drive has been pressed. This means that the user wishes to
  remove the media and requires an action of some kind e.g. have software
  issue a Media Eject or Door Unlock command.
- TK0NF (Track 0 Not Found) indicates track 0 has not been found during a
  Recalibrate command.
- AMNF (Address Mark Not Found) indicates the data address mark has not been
  found after finding the correct ID field.

7.2.10  Features Register

This register is command specific and may be used to enable and disable
features of the interface e.g. by the Set Features Command to enable and
disable cacheing.

This register may be ignored by some drives.

Some hosts, based on definitions prior to the completion of this standard, set
values in this register to designate a recommended Write Precompensation
Cylinder value.

7.2.11  Sector Count Register

This register contains the number of sectors of data requested to be
transferred on a read or write operation between the host and the drive. If
the value in this register is zero, a count of 256 sectors is specified.

If this register is zero at command completion, the command was successful. If
not successfully completed, the register contains the number of sectors which
need to be transferred in order to complete the request.

The contents of this register may be defined otherwise on some commands e.g.
Initialize Drive Parameters, Format Track or Write Same commands.

7.2.12  Sector Number Register

This register contains the starting sector number for any disk data access for
the subsequent command. The sector number may be from 1 to the maximum number
of sectors per track.

In LBA Mode this register contains Bits 0-7. At the end of the command, this
register is updated to reflect the current LBA Bits 0-7.

See the command descriptions for contents of the register at command
completion (whether successful or unsuccessful).

7.2.13  Status Register

This register contains the drive status. The contents of this register are
updated at the completion of each command. When BSY is cleared, the other bits
in this register shall be valid within 400 nsec. If BSY=1, no other bits in
this register are valid. If the host reads this register when an interrupt is
pending, it is considered to be the interrupt acknowledge. Any pending
interrupt is cleared whenever this register is read.

 NOTE: If Drive 1 is not detected as being present, Drive 0 clears the Drive
       1 Status Register to 00h (indicating that the drive is Not Ready).

        7       6       5       4       3       2       1       0
    +-------+-------+-------+-------+-------+-------+-------+-------+
    |  BSY  | DRDY  |  DWF  |  DSC  |  DRQ  | CORR  |  IDX  |  ERR  |
    +-------+-------+-------+-------+-------+-------+-------+-------+

 NOTE: Prior to the definition of this standard, DRDY and DSC were unlatched
       real time signals.

- BSY (Busy) is set whenever the drive has access to the Command Block
  Registers. The host should not access the Command Block Register when
  BSY=1. When BSY=1, a read of any Command Block Register shall return the
  contents of the Status Register. This bit is set by the drive (which may be
  able to respond at times when the media cannot be accessed) under the
  following circumstances:
  a) within 400 nsec after the negation of RESET- or after SRST has been set
     in the Device Control Register. Following acceptance of a reset it is
     recommended that BSY be set for no longer than 30 seconds by Drive 1 and
     no longer than 31 seconds by Drive 0.
  b) within 400 nsec of a host write of the Command Register with a Read,
     Read Long, Read Buffer, Seek, Recalibrate, Initialize Drive Parameters,
     Read Verify, Identify Drive, or Execute Drive Diagnostic command.
  c) within 5 usecs following transfer of 512 bytes of data during execution
     of a Write, Format Track, or Write Buffer command, or 512 bytes of data
     and the appropriate number of ECC bytes during the execution of a Write
     Long command.
- DRDY (Drive Ready) indicates that the drive is capable of responding to a
  command. When there is an error, this bit is not changed until the Status
  Register is read by the host, at which time the bit again indicates the
  current readiness of the drive. This bit shall be cleared at power on and
  remain cleared until the drive is ready to accept a command.
- DWF (Drive Write Fault) indicates the current write fault status. When an
  error occurs, this bit shall not be changed until the Status Register is
  read by the host, at which time the bit again indicates the current write
  fault status.
- DSC (Drive Seek Complete) indicates that the drive heads are settled over a
  track. When an error occurs, this bit shall not be changed until the Status
  Register is read by the host, at which time the bit again indicates the
  current Seek Complete status.
- DRQ (Data Request) indicates that the drive is ready to transfer a word or
  byte of data between the host and the drive.
- CORR (Corrected Data) indicates that a correctable data error was
  encountered and the data has been corrected. This condition does not
  terminate a data transfer.
- IDX (Index) is set once per disk revolution.
- ERR (Error) indicates that an error occurred during execution of the
  previous command. The bits in the Error Register have additional
  information regarding the cause of the error.

8.  Programming Requirements

8.1  Reset Response

A reset is accepted within 400 nsec after the negation of RESET- or within 400
nsec after SRST has been set in the Device Control Register.

When the drive is reset by RESET-, Drive 1 shall indicate it is present by
asserting DASP- within 400 msec, and DASP- shall remain asserted for 30
seconds or until Drive 1 accepts the first command. See also 6.3.4 and 6.3.13.

When the drive is reset by SRST, the drive shall set BSY=1.

See also 7.2.6.

When a reset is accepted, and with BSY set:

a) Both drives perform any necessary hardware initialization
b) Both drives clear any previously programmed drive parameters
c) Both drives may revert to the default condition
d) Both drives load the Command Block Registers with their default values
e) If a hardware reset, Drive 0 waits for DASP- to be asserted by Drive 1
f) If operational, Drive 1 asserts DASP-
g) Drive 0 waits for PDIAG- to be asserted if Drive 1 asserts DASP-
h) If operational, Drive 1 clears BSY
i) If operational, Drive 1 asserts PDIAG-
j) Drive 0 clears BSY

No interrupt is generated when initialization is complete.

The default values for the Command Block Registers if no self-tests are
performed or if no errors occurred are:

     Error         = 01h       Cylinder Low  = 00h
     Sector Count  = 01h       Cylinder High = 00h
     Sector Number = 01h       Drive/Head    = 00h

The Error Register shall contain a Diagnostic Code (see Table 9.2) if a self-
test is performed.

Following any reset, the host should issue an Initialize Drive Parameters
command to ensure the drive is initialized as desired.

There are three types of reset in ATA. The following is a suggested method of
classifying reset actions:

- Power On Reset: the drive executes a series of electrical circuitry
  diagnostics, spins up the HDA, tests speed and other mechanical
  parametrics, and sets default values.
- Hardware Reset: the drive executes a series of electrical circuitry
  diagnostics, and resets to default values.
- Software Reset: the drive resets the interface circuitry according to the
  Set Features requirement (See 9.21)

8.2   Translate Mode

The cylinder, head and sector geometry of the drive as presented to the host
may differ from the actual physical geometry. Translate mode is an optional
and device specific means of mapping between the two.

8.3  Power Conditions

Optional power commands permit the host to modify the behavior of the drive in
a manner which reduces the power required to operate.

                       TABLE 8-1:  POWER CONDITIONS
            +----------+----+----+----+------------------+-----+
            |   Mode   |SRST| BSY|DRDY| Interface Active |Media|
            +----------+----+----+----+------------------+-----+
            | Sleep    |  * |  x |  x |         *        |  0  |
            |          |    |    |    |                  |     |
            | Standby  |  x |  0 |  1 |        Yes       |  0  |
            |          |    |    |    |                  |     |
            | Idle     |  x |  0 |  1 |        Yes       |  1  |
            |          |    |    |    |                  |     |
            | Active   |  x |  x |  x |        Yes       |  1  |
            +----------+----+----+----+------------------+-----+
            |   1 = Active    0 = Inactive        * See 9.23   |
            +--------------------------------------------------+

The lowest power consumption when the drive is powered on occurs in Sleep
mode. When in Sleep mode, the drive requires a reset to be activated (see
9.23). The time to respond could be as long as 30 seconds or more.

In Standby mode the drive interface is capable of accepting commands, but as
the media is not immediately accessible, it could take the drive as long as 30
seconds or more to respond.

In Idle mode the drive is capable of responding immediately to media access
requests. A drive in Idle mode may take longer to complete the execution of a
command because it may have to activate some circuitry.

In Active mode the drive is capable of responding immediately to media access
requests, and commands complete execution in the shortest possible time.

Ready is not a power condition. A drive may post ready at the interface even
though the media may not be accessible.

See specific power-related commands.

8.4  Error Posting

The errors that are valid for each command are defined in Table 8-1. It is not
a requirement that all valid conditions be implemented. See 7.2.9 and 7.2.13
for the definition of the Error Register and Status Register bits.

                       TABLE 8-2:  REGISTER CONTENTS
                         +----------------------------+---------------------+
                         |       Error Register       |   Status Register   |
                         |BBK|UNC|IDNF|ABRT|TK0NF|AMNF|DRDY|DWF|DSC|CORR|ERR|
+------------------------+---+---+----+----+-----+----+----+---+---+----+---+
| Acknowledge Media Chge |   |   |    |  V |     |    |    |   |   |    |   |
| Boot - Post-Boot       |   |   |    |  V |     |    |    |   |   |    |   |
| Boot - Pre-Boot        |   |   |    |  V |     |    |    |   |   |    |   |
| Check Power Mode       |   |   |    |  V |     |    |  V | V | V |    | V |
| Door Lock              |   |   |  V |  V |     |    |  V |   |   |    |   |
| Door Unlock            |   |   |    |  V |     |    |    |   |   |    |   |
| Execute Drive Diags    |         See 9.7            |    |   |   |    | V |
| Format Track           |   |   |  V |  V |     |    |  V | V | V |    | V |
| Identify Drive         |   |   |    |  V |     |    |  V | V | V |    | V |
| Idle                   |   |   |    |  V |     |    |  V | V | V |    | V |
| Idle Immediate         |   |   |    |  V |     |    |  V | V | V |    | V |
| Initialize Drive Parms |   |   |    |    |     |    |  V | V | V |    |   |
| NOP                    |   |   |    |  V |     |    |    |   |   |    | V |
| Read Buffer            |   |   |    |  V |     |    |  V | V | V |    | V |
| Read DMA               | V | V |  V |  V |     |  V |  V | V | V |  V | V |
| Read Long              | V |   |  V |  V |     |  V |  V | V | V |    | V |
| Read Multiple          | V | V |  V |  V |     |  V |  V | V | V |  V | V |
| Read Sector(s)         | V | V |  V |  V |     |  V |  V | V | V |  V | V |
| Read Verify Sector(s)  | V | V |  V |  V |     |  V |  V | V | V |  V | V |
| Recalibrate            |   |   |    |  V |  V  |    |  V | V | V |    | V |
| Seek                   |   |   |  V |  V |     |    |  V | V | V |    | V |
| Set Features           |   |   |    |  V |     |    |  V | V | V |    | V |
| Set Multiple Mode      |   |   |    |  V |     |    |  V | V | V |    | V |
| Sleep                  |   |   |    |  V |     |    |  V | V | V |    | V |
| Standby                |   |   |    |  V |     |    |  V | V | V |    | V |
| Standby Immediate      |   |   |    |  V |     |    |  V | V | V |    | V |
| Write Buffer           |   |   |    |  V |     |    |  V | V | V |    | V |
| Write DMA              | V |   |  V |  V |     |    |  V | V | V |    | V |
| Write Long             | V |   |  V |  V |     |    |  V | V | V |    | V |
| Write Multiple         | V |   |  V |  V |     |    |  V | V | V |    | V |
| Write Same             | V |   |  V |  V |     |    |  V | V | V |    | V |
| Write Sector(s)        | V |   |  V |  V |     |    |  V | V | V |    | V |
| Write Verify           | V | V |  V |  V |     | V  |  V | V | V | V  | V |
+------------------------+---+---+----+----+-----+----+----+---+---+----+---+
| Invalid Command Code   |   |   |    |  V |     |    |  V | V | V |    | V |
+------------------------+---+---+----+----+-----+----+----+---+---+----+---+
| V = valid on this command                                                 |
+---------------------------------------------------------------------------+

9.  Command Descriptions

Commands are issued to the drive by loading the pertinent registers in the
command block with the needed parameters, and then writing the command code to
the Command Register.

The manner in which a command is accepted varies. There are three classes
(see Table 9-1) of command acceptance, all predicated on the fact that to
receive a command, BSY=0:

- Upon receipt of a Class 1 command, the drive sets BSY within 400 nsec.
- Upon receipt of a Class 2 command, the drive sets BSY within 400 nsec, sets
  up the sector buffer for a write operation, sets DRQ within 700 usec, and
  clears BSY within 400 nsec of setting DRQ.
- Upon receipt of a Class 3 command, the drive sets BSY within 400 nsec, sets
  up the sector buffer for a write operation, sets DRQ within 20 msec, and
  clears BSY within 400 nsec of setting DRQ.

 NOTE: DRQ may be set so quickly on Class 2 and Class 3 that the BSY
       transition is too short for BSY=1 to be recognized.

The drive shall implement all mandatory commands as identified by an M, and
may implement the optional commands identified by an O, in Table 9-1. V
indicates a Vendor Specific command code.

If a new command is issued to a drive which has an uncompleted command
(subsequently referred to as Old_Command) in progress, the drive shall
immediately respond to the new command (Subsequently referred to as
New_Command), even if execution of the Old_Command could have been completed.

There shall be no indication given to the system as to the status of the
Old_Command which was being executed at the time the New_Command was issued.

           TABLE 9-1:  COMMAND CODES AND PARAMETERS - Part 1 of 2
                                              +-------+-------------------+
 +-----+                                      |Command|  Parameters Used  |
 |Class|                                      | Code  |FR  SC  SN  CY  DH |
 +-----+----------------------------------+---+-------+---+---+---+---+---+
 |  1  | Acknowledge Media Chge           | O |  DBh  |   |   |   |   | D |
 |  1  | Boot - Post-Boot                 | O |  DCh  |   |   |   |   | D |
 |  1  | Boot - Pre-Boot                  | O |  DDh  |   |   |   |   | D |
 |  1  | Check Power Mode                 | O |98h E5h|   | y |   |   | D |
 |  1  | Door Lock                        | O |  DEh  |   |   |   |   | D |
 |  1  | Door Unlock                      | O |  DFh  |   |   |   |   | D |
 |  1  | Execute Drive Diagnostic         | M |  90h  |   |   |   |   | D*|
 |  2  | Format Track                     | M |  50h  | * | y |   | y | y |
 |  1  | Identify Drive                   | O |  ECh  |   |   |   |   | D |
 |  1  | Idle                             | O |97h E3h|   | y |   |   | D |
 |  1  | Idle Immediate                   | O |95h E1h|   |   |   |   | D |
 |  1  | Initialize Drive Parameters      | M |  91h  |   | y |   |   | y |
 |  1  | NOP                              | O |  00h  |   |   |   |   | y |
 |  1  | Read Buffer                      | O |  E4h  |   |   |   |   | D |
 |  1  | Read DMA (w/retry)               | O |  C8h  |   | y | y | y | y |
 |  1  | Read DMA (w/o retry)             | O |  C9h  |   | y | y | y | y |
 |  1  | Read Long (w/retry)              | M |  22   |   | y | y | y | y |
 |  1  | Read Long (w/o retry)            | M |  23   |   | y | y | y | y |
 |  1  | Read Multiple                    | O |  C4h  |   | y | y | y | y |
 |  1  | Read Sector(s) (w/retry)         | M |  20   |   | y | y | y | y |
 |  1  | Read Sector(s) (w/o retry)       | M |  21   |   | y | y | y | y |
 |  1  | Read Verify Sector(s) (w/retry)  | M |  40   |   | y | y | y | y |
 |  1  | Read Verify Sector(s) (w/o retry)| M |  41   |   | y | y | y | y |
 |  1  | Recalibrate                      | M |  1xh  |   |   |   |   | D |
 +-----+----------------------------------+---+-------+---+---+---+---+---+
           TABLE 9-1:  COMMAND CODES AND PARAMETERS - Part 2 of 2
                                              +-------+-------------------+
 +-----+                                      |Command|  Parameters Used  |
 |Class|                                      | Code  |FR  SC  SN  CY  DH |
 +-----+----------------------------------+---+-------+---+---+---+---+---+
 |  1  | Seek                             | M |  7xh  |   |   | y | y | y |
 |  1  | Set Features                     | O |  EFh  | y |   |   |   | D |
 |  1  | Set Multiple Mode                | O |  C6h  |   | y |   |   | D |
 |  1  | Sleep                            | O |99h E6h|   |   |   |   | D |
 |  1  | Standby                          | O |96h E2h|   | y |   |   | D |
 |  1  | Standby Immediate                | O |94h E0h|   |   |   |   | D |
 |  2  | Write Buffer                     | O |  E8h  |   |   |   |   | D |
 |  3  | Write DMA (w/retry)              | O |  CAh  |   | y | y | y | y |
 |  3  | Write DMA (w/o retry)            | O |  CBh  |   | y | y | y | y |
 |  2  | Write Long (w/retry)             | M |  32   | * | y | y | y | y |
 |  2  | Write Long (w/o retry)           | M |  33   | * | y | y | y | y |
 |  3  | Write Multiple                   | O |  C5h  | * | y | y | y | y |
 |  3  | Write Same                       | O |  E9h  | y | y | y | y | y |
 |  2  | Write Sector(s) (w/retry)        | M |  30   | * | y | y | y | y |
 |  2  | Write Sector(s) (w/o retry)      | M |  31   | * | y | y | y | y |
 |  3  | Write Verify                     | O |  3Ch  | * | y | y | y | y |
 |     | Vendor Unique                    | V |  9Ah  |   |   |   |   |   |
 |     | Vendor Unique                    | V | C0-C3h|   |   |   |   |   |
 |     | Vendor Unique                    | V |  8xh  |   |   |   |   |   |
 |     | Vendor Unique                    | V |F0h-FFh|   |   |   |   |   |
 |     | Reserved: All remaining codes    |   |       |   |   |   |   |   |
 +-----+----------------------------------+---+-------+---+---+---+---+---+
 |     | CY = Cylinder Registers         SC = Sector Count Register       |
 |     | DH = Drive/Head Register        SN = Sector Number Register      |
 |     | FR = Features Register (see command descriptions for use)        |
 |     | y - the register contains a valid parameter for this command.    |
 |     |     For the Drive/Head Register, y means both the drive and      |
 |     |     head parameters are used.                                    |
 |     | D - only the drive parameter is valid and not the head parameter.|
 |     | D* - Addressed to Drive 0 but both drives execute it.            |
 |     | * - Maintained for compatibility (see 7.2.9)                     |
 +-----+------------------------------------------------------------------+

9.1  Acknowledge Media Change (Removable)

If the drive is operating in a mode which requires that the operating system
acknowledge a media change, this command clears the Media Change Error so that
normal operation can resume. If the drive is not operating in such a mode,
this command returns an Abort error.

9.2  Boot - Post-Boot (Removable)

This command provides a means to send vendor-specific information that may be
required in order to pass diagnostics which are applicable to non-removable
disk drives.

9.3  Boot - Pre-Boot (Removable)

This command is issued to prepare a removable drive to respond to boot.

9.4  Check Power Mode

This command checks the power mode.

If the drive is in, going to, or recovering from the Standby Mode the drive
shall set BSY, set the Sector Count Register to 00h, clear BSY, and generate
an interrupt.

If the drive is in the Idle Mode, the drive shall set BSY, set the Sector
Count Register to FFh, clear BSY, and generate an interrupt.

9.5  Door Lock (Removable)

This command locks the door if the drive is Ready and unlocked, otherwise it
responds with Not Ready.

9.6  Door Unlock (Removable)

This command unlocks the door if the drive is Ready and locked, otherwise it
responds with Not Ready.

9.7  Execute Drive Diagnostic

This command shall perform the internal diagnostic tests implemented by the
drive. See also 6.3.4 and 6.3.13. The DRV bit is ignored. Both drives, if
present, shall execute this command.

If Drive 1 is present:

- Drive 0 waits up to 5 seconds for Drive 1 to assert PDIAG-.
- If Drive 1 has not asserted PDIAG-, indicating a failure, Drive 0 shall
  append 80h to its own diagnostic status.
- Both drives shall execute diagnostics.
- If Drive 1 diagnostic failure is detected when Drive 0 status is read,
  Drive 1 status is obtained by setting the DRV bit, and reading status.

If there is no Drive 1 present:

- Drive 0 posts only its own diagnostic results.
- Drive 0 clears BSY, and generates an interrupt.

The Diagnostic Code written to the Error Register is a unique 8-bit code as
shown in Table 9-2, and not as the single bit flags defined in 7.2.9.

If Drive 1 fails diagnostics, Drive 0 "ORs" 80h with its own status and loads
that code into the Error Register. If Drive 1 passes diagnostics or there is
no Drive 1 connected, Drive 0 "ORs" 00h with its own status and loads that
code into the Error Register.

                        TABLE 9-2:  DIAGNOSTIC CODES
                +-------+
                | Code  |
                +-------+----------------------------------+
                |  01h  | No error detected                |
                |  02h  | Formatter device error           |
                |  03h  | Sector buffer error              |
                |  04h  | ECC circuitry error              |
                |  05h  | Controlling microprocessor error |
                |  8xh  | Drive 1 failed                   |
                +-------+----------------------------------+

9.8  Format Track

The implementation of the Format Track command is vendor specific. The actions
may be a physical reformatting of a track, initializing the data field
contents to some value, or doing nothing.

The Sector Count Register contains the number of sectors per track.

The track address is specified in the Cylinder High and Cylinder Low
Registers, and the number of sectors is specified in the Sector Count
Register. When the command is accepted, the drive sets the DRQ bit and waits
for the host to fill the sector buffer. When the sector buffer is full, the
drive clears DRQ, sets BSY and begins command execution.

The contents of the sector buffer shall not be written to the media, and may
be either ignored or interpreted as follows:

    DD15 ---- DD0               DD15 ---- DD0
   +-------------+             +-------------+--------------------------+
   | First Sector|             | Last Sector |  Remainder of buffer     |
   | Descriptor  | : : : : : : | Descriptor  |  filled with zeros       |
   +-------------+             +-------------+--------------------------+

One 16-bit word represents each sector, the words being contiguous from the
start of a sector. Any words remaining in the buffer after the representation
of the last sector are filled with zeros. DD15-8 contain the sector number. If
an interleave is specified, the words appear in the same sequence as they
appear on the track. DD7-0 contain a descriptor value defined as follows:

    00h - Format sector as good
    20h - Unassign the alternate location for this sector
    40h - Assign this sector to an alternate location
    80h - Format sector as bad

 NOTE: Some users of the ATA drive expect the operating system partition
       table to be erased on a Format command. It is recommended that a drive
       which does not perform a physical format of the track, write a data
       pattern of all zeros to the sectors which have been specified by the
       Format Track command.

 NOTE: It is recommended that implementors resassign data blocks which show
       repeated errors.

9.9  Identify Drive

The Identify Drive command enables the host to receive parameter information
from the drive. When the command is issued, the drive sets BSY, stores the
required parameter information in the sector buffer, sets DRQ, and generates
an interrupt. The host then reads the information out of the sector buffer.
The parameter words in the buffer have the arrangement and meanings defined in
Table 9-3. All reserved bits or words shall be zero.

+-------+          TABLE 9-3:  IDENTIFY DRIVE INFORMATION (1)
|  Word |
+-------+------------------------------------------------------------------+
|    0  | General configuration bit-significant information:               |
|       |   15  0   reserved for non-magnetic drives                       |
|       |   14  1=format speed tolerance gap required                      |
|       |   13  1=track offset option available                            |
|       |   12  1=data strobe offset option available                      |
|       |   11  1=rotational speed tolerance is > 0.5%                     |
|       |   10  1=disk transfer rate > 10 Mbs                              |
|       |    9  1=disk transfer rate > 5Mbs but <= 10Mbs                   |
|       |    8  1=disk transfer rate <= 5Mbs                               |
|       |    7  1=removable cartridge drive                                |
|       |    6  1=fixed drive                                              |
|       |    5  1=spindle motor control option implemented                 |
|       |    4  1=head switch time > 15 usec                               |
|       |    3  1=not MFM encoded                                          |
|       |    2  1=soft sectored                                            |
|       |    1  1=hard sectored                                            |
|       |    0  0=reserved                                                 |
|    1  | Number of cylinders                                              |
|    2  |   reserved                                                       |
|    3  | Number of heads                                                  |
|    4  | Number of unformatted bytes per track                            |
|    5  | Number of unformatted bytes per sector                           |
|    6  | Number of sectors per track                                      |
|  7-9  |   Vendor Unique                                                  |
| 10-19 | Serial number (20 ASCII characters, 0000h=not specified)         |
|   20  | Buffer type                                                      |
|   21  | Buffer size in 512 byte increments (0000h=not specified)         |
|   22  | # of ECC bytes avail on Read/Write Long cmds (0000h=not spec'd)  |
| 23-26 | Firmware revision (8 ASCII characters, 0000h=not specified)      |
| 27-46 | Model number (40 ASCII characters, 0000h=not specified)          |
+-------+------------------------------------------------------------------+

+-------+          TABLE 9-3:  IDENTIFY DRIVE INFORMATION (2)
|  Word |
+-------+------------------------------------------------------------------+
|   47  | 15-8  Vendor Unique                                              |
|       |  7-0  00h = Read/Write Multiple commands not implemented         |
|       |       xxh = Maximum number of sectors that can be transferred    |
|       |             per interrupt on Read and Write Multiple commands    |
|   48  | 0000h = cannot perform doubleword I/O    Included for Backwards  |
|       | 0001h = can perform doubleword I/O       Compatible VU Use       |
|   49  | Capabilities                                                     |
|       | 15-10  0=reserved                                                |
|       |     9  1=LBA Supported                                           |
|       |     8  1=DMA Supported                                           |
|       |  7- 0  Vendor Unique                                             |
|   50  |   reserved                                                       |
|   51  | 15-8  PIO data transfer cycle timing mode                        |
|       |  7-0  Vendor Unique                                              |
|   52  | 15-8  DMA data transfer cycle timing mode                        |
|       |  7-0  Vendor Unique                                              |
|   53  | 15-1    reserved                                                 |
|       |    0  1=the fields reported in Words 54-58 are valid             |
|       |       0=the fields reported in Words 54-58 may be valid          |
|   54  | Number of current cylinders                                      |
|   55  | Number of current heads                                          |
|   56  | Number of current sectors per track                              |
| 57-58 | Current capacity in sectors                                      |
|   59  | 15-9    reserved                                                 |
|       |    8  1 = Multiple Sector Setting is Valid                       |
|       |  7-0  xxh = Current setting for number of sectors that can be    |
|       |             transferred per interrupt on R/W Multiple commands   |
| 60-61 | Total Number of User Addressable Sectors (LBA Mode Only)         |
|   62  | 15-8  Single Word DMA Transfer Mode Active                       |
|       |  7-0  Single Word DMA Transfer Modes Supported (see 11-3a)       |
|   63  | 15-8  Multiword DMA Transfer Mode Active                         |
|       |  7-0  Multiword DMA Transfer Modes Supported (see 11-3b)         |
| 64-127|   reserved                                                       |
|128-159| Vendor Unique                                                    |
|160-255|   reserved                                                       |
+-------+------------------------------------------------------------------+

The fields described in 9.4.1 through 9.4.5 are not affected by the Initialize
Drive Parameters command.

9.9.1  Word 1: Number of cylinders

The number of user-addressable cylinders in the default translation mode.

9.9.2  Word 3: Number of heads

The number of user-addressable heads in the default translation mode.

9.9.3  Word 4: Number of unformatted bytes per track

The number of unformatted bytes per translated track in the default
translation mode.

9.9.4  Word 5: Number of unformatted bytes per sector

The number of unformatted bytes per sector in the default translation mode.

9.9.5  Word 6: Number of sectors per track

The number of user-addressable sectors per track in the default translation
mode.

9.9.6  Word 10-19: Serial Number

The contents of this field are right justified and padded with spaces (20h).

9.9.7  Word 20: Buffer Type

The contents of the field are determined by the manufacturer.

 0000h = not specified.
 0001h = a single ported single sector buffer which is not capable of
         simultaneous data transfers to or from the host and the disk.
 0002h = a dual ported multi-sector buffer capable of simultaneous data
         transfers to or from the host and the disk.
 0003h = a dual ported multi-sector buffer capable of simultaneous transfers
         with a read cacheing capability.
 0004-FFFFh = reserved

These codes are typically not used by the operating system, however, they are
useful for diagnostic programs which perform initialization routines e.g. a
different interleave may be desirable for 0001h vs 0002h or 0003h.

9.9.8  Word 22: ECC bytes Available on Read/Write Long Commands

If the contents of this field are set to a value other than 4, the only way to
use this information is via the Set Features commands.

9.9.9  Word 23-26: Firmware Revision

The contents of this field are left justified and padded with spaces (20h).

9.9.10  Word 27-46: Model Number

The contents of this field are left justified and padded with spaces (20h).

9.9.11 Word 51:  PIO data transfer cycle timing mode

The PIO transfer timing for each ATA device falls into categories which have
unique parametric timing specifications. To determine the proper device timing
category, compare the Cycle Time specified in Figure 11-1 with the contents of
this field. The value returned in Bits 15-8 should fall into one of the
categories specified in Figure 11-1, and if it does not, then Mode 0 shall be
used to serve as the default timing.

9.9.12 Word 52:  DMA data transfer cycle timing mode

The DMA transfer timing for each ATA device falls into categories which have
unique parametric timing specifications. To determine the proper device timing
category, compare the Cycle Time specified in Figure 11-3 with the contents of
this field. The value returned in Bits 15-8 should fall into one of the
categories specified in Figure 11-3, and if it does not, then Mode 0 shall be
used to serve as the default timing.

The contents of this word shall be ignored if Words 62 or 63 are supported.

9.9.13 Word 54:  Number of current cylinders

The number of user-addressable cylinders in the current translation mode.

9.9.14 Word 55:  Number of current heads

The number of user-addressable heads in the current translation mode.

9.9.15 Word 56:  Number of current sectors per track

The number of user-addressable sectors per track in the current translation
mode.

9.9.16 Word 57-58: Current capacity in sectors

The current capacity in sectors excludes all sectors used for device-specific
purposes. The number of sectors of available capacity may be calculated as:

  (Number of current cylinders
   * Number of current heads
   * Number of current sectors per track)


9.9.17  Word 59: Multiple Sector Setting

If the valid bit is set, then bits 7-0 reflect the number of sectors currently
set to transfer on a Read or Write Multiple command.

9.9.18  Word 60-61: Total Number of User Addressable Sectors

If the drive supports LBA Mode, these words reflect the total number of user
addressable sectors. This value does not depend on the current drive geometry.
If the drive does not support LBA mode, these words shall be set to 0.

9.9.19  Word 62: Single Word DMA Transfer

The low order byte identifies by bit all of the Modes which are supported e.g.
if Mode 0 is supported, bit 0 is set. The high order byte contains a single
bit set to indicate which mode is active.

9.9.20  Word 63: Multiword DMA Transfer

The low order byte identifies by bit all of the Modes which are supported e.g.
if Mode 0 is supported, bit 0 is set. The high order byte contains a single
bit set to indicate which mode is active.

9.10  Idle

This command causes the drive to set BSY, enter the Idle Mode, clear BSY, and
generate an interrupt. The interrupt is generated even though the drive may
not have fully transitioned to Idle Mode.

If the drive is already spinning, the spinup sequence is not executed.

If the Sector Count Register is non-zero then the automatic power down
sequence shall be enabled and the timer begins counting down immediately. If
the Sector Count Register is zero then the automatic power down sequence shall
be disabled.

9.11  Idle Immediate

This command causes the drive to set BSY, enter the Idle Mode, clear BSY, and
generate an interrupt. The interrupt is generated even though the drive may
not have fully transitioned to Idle Mode.

9.12  Initialize Drive Parameters

This command enables the host to set the number of sectors per track and the
number of heads minus 1, per cylinder. Upon receipt of the command, the drive
sets BSY, saves the parameters, clears BSY, and generates an interrupt.

The only two register values used by this command are the Sector Count
Register which specifies the number of sectors per track, and the Drive/Head
Register which specifies the number of heads minus 1. The DRV bit designates
these values to Drive 0 or Drive 1, as appropriate.

The sector count and head values are not checked for validity by this command.
If they are invalid, no error will be posted until an illegal access is made
by some other command.

9.13  NOP

This command enables a host which can only perform 16-bit register accesses to
check drive status. The drive shall respond as it does to an unrecognized
command by setting Abort in the Error Register, Error in the Status Register,
clearing Busy in the Status Register, and asserting INTRQ.

NOTE: When a 16-bit host writes to the Drive Head Register, one byte contains
     the Command Register, so the drive sees a new command when the intended
     purpose is only to select a drive. Both drives may be Busy but not
     necessarily Ready i.e. Drive 0 may be ready, but not drive 1. To check
     this possibility a typical sequence for an 8-bit host would be:

      a. Read the Status Register (wait until Busy False)
      b. Select the drive (write to the Drive Head Register)
      c. Read the Status Register (wait until Busy False and Ready True)
      d. Send the command (write to the Command Register).

     As a 16-bit host executes 2 and 4 simultaneously, a problem occurs if
     the drive being selected is Not Ready at the time the command is issued.

9.14  Read Buffer

The Read Buffer command enables the host to read the current contents of the
drive's sector buffer. When this command is issued, the drive sets BSY, sets
up the sector buffer for a read operation, sets DRQ, clears BSY, and generates
an interrupt. The host then reads up to 512 bytes of data from the buffer.

The Read Buffer and Write Buffer commands shall be synchronized such that
sequential Write Buffer and Read Buffer commands access the same 512 bytes
within the buffer.

9.15  Read DMA

This command executes in a similar manner to the Read Sectors command except
for the following:

- the host initializes a slave-DMA channel prior to issuing the command
- data transfers are qualified by DMARQ and are performed by the slave-DMA
  channel
- the drive issues only one interrupt per command to indicate that data
  transfer has terminated and status is available.

Any unrecoverable error encountered during execution of a Read DMA command
results in the termination of data transfer at the sector where the error was
detected. The sector in error is not transferred. The drive generates an
interrupt to indicate that data transfer has terminated and status is
available. The error posting is the same as that of the Read Sectors command.

9.16  Read Long

The Read Long command performs similarly to the Read Sectors command except
that it returns the data and the ECC bytes contained in the data field of the
desired sector. During a Read Long command, the drive does not check the ECC
bytes to determine if there has been a data error. Only single sector read
long operations are supported.

The transfer of the ECC bytes shall be 8-bits wide.

9.17  Read Multiple Command

The Read Multiple command performs similarly to the Read Sectors command.
Interrupts are not generated on every sector, but on the transfer of a block
which contains the number of sectors defined by a Set Multiple command.

Command execution is identical to the Read Sectors operation except that the
number of sectors defined by a Set Multiple command are transferred without
intervening interrupts. DRQ qualification of the transfer is required only at
the start of the data block, not on each sector.

The block count of sectors to be transferred without intervening interrupts is
programmed by the Set Multiple Mode command, which shall be executed prior to
the Read Multiple command.

When the Read Multiple command is issued, the Sector Count Register contains
the number of sectors (not the number of blocks or the block count) requested.

If the number of requested sectors is not evenly divisible by the block count,
as many full blocks as possible are transferred, followed by a final, partial
block transfer. The partial block transfer shall be for n sectors, where

         n = Remainder (Sector Count / Block Count)

If the Read Multiple command is attempted before the Set Multiple Mode command
has been executed or when Read Multiple commands are disabled, the Read
Multiple operation shall be rejected with an Aborted Command error.

Disk errors encountered during Read Multiple commands are posted at the
beginning of the block or partial block transfer, but DRQ is still set and the
data transfer shall take place as it normally would, including transfer of
corrupted data, if any.

The contents of the Command Block Registers following the transfer of a data
block which had a sector in error are undefined. The host should retry the
transfer as individual requests to obtain valid error information.

Subsequent blocks or partial blocks are transferred only if the error was a
correctable data error. All other errors cause the command to stop after
transfer of the block which contained the error. Interrupts are generated when
DRQ is set at the beginning of each block or partial block.

9.18  Read Sector(s)

This command reads from 1 to 256 sectors as specified in the Sector Count
register. A sector count of 0 requests 256 sectors. The transfer begins at the
sector specified in the Sector Number Register. See 10.1 for the DRQ, IRQ and
BSY protocol on data transfers.

If the drive is not already on the desired track, an implied seek is
performed. Once at the desired track, the drive searches for the appropriate
ID field.

If retries are disabled and two index pulses have occurred without error free
reading of the requested ID, an ID Not Found error is posted.

If retries are enabled, up to a vendor specific number of attempts may be made
to read the requested ID before posting an error.

If the ID is read correctly, the data address mark shall be recognized within
a specified number of bytes, or the Address Mark Not Found error is posted.

DRQ is always set prior to data transfer regardless of the presence or absence
of an error condition.

At command completion, the Command Block Registers contain the cylinder, head,
and sector number of the last sector read.

If an error occurs, the read terminates at the sector where the error
occurred. The Command Block Registers contain the cylinder, head, and sector
number of the sector where the error occurred.

The flawed data is pending in the sector buffer.

9.19  Read Verify Sector(s)

This command is identical to the Read Sectors command, except that DRQ is
never set, and no data is transferred to the host. See 10.3 for protocol. When
the command is accepted, the drive sets BSY.

When the requested sectors have been verified, the drive clears BSY and
generates an interrupt. Upon command completion, the Command Block Registers
contain the cylinder, head, and sector number of the last sector verified.

If an error occurs, the verify terminates at the sector where the error
occurs. The Command Block Registers contain the cylinder, head, and sector
number of the sector where the error occurred. The Sector Count Register shall
contain the number of sectors not yet verified.

9.20  Recalibrate

This command moves the read/write heads from anywhere on the disk to cylinder
0. Upon receipt of the command, the drive sets BSY and issues a seek to
cylinder zero. The drive then waits for the seek to complete before updating
status, clearing BSY and generating an interrupt.

If the drive cannot reach cylinder 0, a Track Not Found error is posted.

9.21  Seek

This command initiates a seek to the track and selects the head specified in
the command block. The drive need not be formatted for a seek to execute
properly. See 10.3 for protocol. The drive shall not set DSC=1 until the
action of seeking has completed. The drive may return the interrupt before the
seek is completed.

If another command is issued to the drive while a seek is being executed, the
drive sets BSY=1, waits for the seek to complete, and then begins execution of
the command.

9.22  Set Features

This command is used by the host to establish the following parameters which
affect the execution of certain drive features as shown in Table 9-4.

                TABLE 9-4:  SET FEATURE REGISTER DEFINITIONS
   +-----+---------------------------------------------------------------+
   | 01h | Enable 8-bit data transfers (see 6.3.5)                       |
   | 02h | Enable Write Cache *                                          |
   | 03h | Set Transfer Mode based on value in Sector Count Register     |
   | 33h | Disable Retry *                                               |
   | 44h | Vendor unique length of ECC on Read Long/Write Long commands  |
   | 54h | Set cache segments to Sector Count Register value *           |
   | 55h | Disable read look-ahead feature                               |
   | 66h | Disable reverting to power on defaults (see 9.22)             |
   | 77h | Disable ECC *                                                 |
   | 81h | Disable 8-bit data transfers (see 6.3.5)                      |
   | 82h | Disable Write Cache *                                         |
   | 88h | Enable ECC *                                                  |
   | 99h | Enable Retries *                                              |
   | AAh | Enable read look-ahead feature                                |
   | ABh | Set maximum prefetch using Sector Count Register value *      |
   | BBh | 4 bytes of ECC apply on Read Long/Write Long commands         |
   | CCh | Enable reverting to power on defaults (see 9.22)              |
   +-----+---------------------------------------------------------------+
           * These commands are Vendor-specified

See 10.3 for protocol. If the value in the register is not supported or is
invalid, the drive posts an Aborted Command error.

At power on, or after a hardware reset, the default mode is the same as that
represented by values greater than 80h. A setting of 66h allows settings of
greater than 80h which may have been modified since power on to remain at the
same setting after a software reset.

A host can choose the transfer mechanism by Set Transfer Mode and specifying a
value in the Sector Count Register. The upper 5 bits define the type of
transfer and the low order 3 bits encode the mode value.

  Block Transfer (Default)    00000  000
  Single Word DMA Mode x      00010  0xx
  Multiword DMA Mode 0        00100  000

See vendor specification for the default mode of the commands which are
vendor-specified.

9.23  Set Multiple Mode

This command enables the drive to perform Read and Write Multiple operations
and establishes the block count for these commands. See 10.3 for protocol.

The Sector Count Register is loaded with the number of sectors per block.
Drives shall support block sizes of 2, 4, 8, and 16 sectors, if their buffer
size is at least 8,192 bytes, and may also support other block sizes. Upon
receipt of the command, the drive sets BSY=1 and checks the Sector Count
Register.

If the Sector Count Register contains a valid value and the block count is
supported, the value is loaded for all subsequent Read Multiple and Write
Multiple commands and execution of those commands is enabled. If a block count
is not supported, an Aborted Command error is posted, and Read Multiple and
Write Multiple commands are disabled.

If the Sector Count Register contains 0 when the command is issued, Read and
Write Multiple commands are disabled.

At power on, or after a hardware reset, the default mode is Read and Write
Multiple disabled. If Disable Default has been set in the Features Register
then the mode remains the same as that last established prior to a software
reset, otherwise it reverts to the default of disabled.

9.24  Sleep

This command is the only way to cause the drive to enter Sleep Mode. The drive
is spun down, and when it is stopped, BSY is cleared, an interrupt is
generated, and the interface becomes inactive.

The only way to recover from Sleep mode is with a software reset or a hardware
reset.

 NOTE: The use of hardware reset to recover from Sleep mode may be
       incompatible with continued operation of the host system.

A drive shall not power on in Sleep Mode nor remain in Sleep Mode following a
reset sequence. If the drive is already spun down, the spin down sequence is
not executed.

9.25  Standby

This command causes the drive to enter the Standby Mode. See 10.3 for
protocol. The drive may return the interrupt before the transition to Standby
Mode is completed.

If the drive is already spun down, the spin down sequence is not executed.

If the Sector Count Register is non-zero then the automatic power down
sequence shall be enabled and the timer will begin counting down when the
drive returns to Idle mode. If the Sector Count Register is zero then the
automatic power down sequence shall be disabled.

9.26  Standby Immediate

This command causes the drive to enter the Standby Mode. See 10.3 for
protocol. The drive may return the interrupt before the transition to Standby
Mode is completed.

If the drive is already spun down, the spin down sequence is not executed.

9.27  Write Buffer

This command enables the host to overwrite the contents of the drive's sector
buffer with any data pattern desired. See 10.2 for protocol.

The Read Buffer and Write Buffer commands shall be synchronized within the
drive such that sequential Write Buffer and Read Buffer commands access the
same 512 bytes within the buffer.

9.28  Write DMA

This command executes in a similar manner to Write Sectors except for the
following:

- the host initializes a slave-DMA channel prior to issuing the command
- data transfers are qualified by DMARQ and are performed by the slave-DMA
  channel
- the drive issues only one interrupt per command to indicate that data
  transfer has terminated and status is available.

Any error encountered during Write DMA execution results in the termination of
data transfer. The drive issues an interrupt to indicate that data transfer
has terminated and status is available in the Error Register. The error
posting is the same as that of the Write Sectors command.

9.29  Write Long

This command is similar to the Write Sectors command except that it writes the
data and the ECC bytes directly from the sector buffer; the drive does not
generate the ECC bytes itself. Only single sector Write Long operations are
supported.

The transfer of the ECC bytes shall be 8-bits wide.

9.30  Write Multiple Command

This command is similar to the Write Sectors command. The drive sets BSY
within 400 nsec of accepting the command, and interrupts are not presented on
each sector but on the transfer of a block which contains the number of
sectors defined by Set Multiple.

Command execution is identical to the Write Sectors operation except that the
number of sectors defined by the Set Multiple command are transferred without
intervening interrupts. DRQ qualification of the transfer is required only at
the start of the data block, not on each sector.

The block count of sectors to be transferred without intervening interrupts is
programmed by the Set Multiple Mode command, which shall be executed prior to
the Read Multiple command.

When the Write Multiple command is issued, the Sector Count Register contains
the number of sectors (not the number of blocks or the block count) requested.

If the number of requested sectors is not evenly divisible by the block count,
as many full blocks as possible are transferred, followed by a final, partial
block transfer. The partial block transfer is for n sectors, where

         n = Remainder (Sector Count / Block Count)

If the Write Multiple command is attempted before the Set Multiple Mode
command has been executed or when Write Multiple commands are disabled, the
Write Multiple operation shall be rejected with an aborted command error.

Disk errors encountered during Write Multiple commands are posted after the
attempted disk write of the block or partial block transferred. The Write
command ends with the sector in error, even if it was in the middle of a
block. Subsequent blocks are not transferred in the event of an error.
Interrupts are generated when DRQ is set at the beginning of each block or
partial block.

The contents of the Command Block Registers following the transfer of a data
block which had a sector in error are undefined. The host should retry the
transfer as individual requests to obtain valid error information.

9.31  Write Same

This command executes in a similar manner to Write Sectors except that only
one sector of data is transferred. The contents of the sector are written to
the medium one or more times.

NOTE: The Write Same command allows for initialization of part or all of the
medium to the specified data with a single command.

If the Features Register is 22h, the drive shall write that part of the medium
specified by the sector count, sector number, cylinder and drive/head
registers. If the Features Register contains DDh, the drive shall initialize
all the user accessible medium. If the register contains a value other than
22h or DDh, the command shall be rejected with an aborted command error.

The drive issues an interrupt to indicate that the command is complete. Any
error encountered during execution results in the termination of the write
operation. Status is available in the Error Register if an error occurs. The
error posting is the same as that of the Write Sectors command.

9.32  Write Sector(s)

This command writes from 1 to 256 sectors as specified in the Sector Count
Register (a sector count of zero requests 256 sectors), beginning at the
specified sector. See 10.1 for the DRQ, IRQ and BSY protocol on data
transfers.

If the drive is not already on the desired track, an implied seek is
performed. Once at the desired track, the drive searches for the appropriate
ID field.

If retries are disabled and two index pulses have occurred without error free
reading of the requested ID, an ID Not Found error is posted.

If retries are enabled, up to a vendor specific number of attempts may be made
to read the requested ID before posting an error.

If the ID is read correctly, the data loaded in the buffer is written to the
data field of the sector, followed by the ECC bytes. Upon command completion,
the Command Block Registers contain the cylinder, head, and sector number of
the last sector written.

If an error occurs during a write of more than one sector, writing terminates
at the sector where the error occurs. The Command Block Registers contain the
cylinder, head, and sector number of the sector where the error occurred. The
host may then read the command block to determine what error has occurred, and
on which sector.

9.33  Write Verify

This command is similar to the Write Sectors command, except that each sector
is verified immediately after being written. The verify operation is a read
without transfer and a check for data errors. Any errors encountered during
the verify operation are posted. Multiple sector Write Verify commands write
all the requested sectors and then verify all the requested sectors before
generating the final interrupt.

10. Protocol Overview

Commands can be grouped into different classes according to the protocols
followed for command execution. The command classes with their associated
protocols are defined below.

For all commands, the host first checks if BSY=1, and should proceed no
further unless and until BSY=0. For most commands, the host will also wait for
DRDY=1 before proceeding. Those commands shown with DRDY=x can be executed
when DRDY=0.

Data transfers may be accomplished in more ways than are described below, but
these sequences should work with all known implementations of ATA drives.

10.1  PIO Data In Commands

This class includes:

- Identify Drive
- Read Buffer
- Read Long
- Read Sector(s)

Execution includes the transfer of one or more 512 byte (>512 bytes on Read
Long) sectors of data from the drive to the host.

a) The host writes any required parameters to the Features, Sector Count,
   Sector Number, Cylinder and Drive/Head registers.
b) The host writes the command code to the Command Register.
c) The drive sets BSY and prepares for data transfer.
d) When a sector of data is available, the drive sets DRQ and clears BSY
   prior to asserting INTRQ.
e) After detecting INTRQ, the host reads the Status Register, then reads one
   sector of data via the Data Register. In response to the Status Register
   being read, the drive negates INTRQ.
f) The drive clears DRQ. If transfer of another sector is required, the drive
   also sets BSY and the above sequence is repeated from d).

10.1.1  PIO Read Command

+- a) -+-- b) -+        +- e) -+--------+       +- e) -+--------+
|Setup | Issue |        | Read |Transfer|       | Read |Transfer|
|      |Command|        |Status|  Data  |:::::::|Status|  Data  |
+------+-------+        +------+--------+       +------+--------+
|BSY=0 |       |BSY=1   |BSY=0 |        |BSY=1  |BSY=0 |        |BSY=1
       |DRDY=1          |      |        |       |      |        |
                        |DRQ=1 |        |DRQ=0  |DRQ=1 |        |DRQ=0
                        |Assert|Negate  |       |Assert|Negate
                         INTRQ  INTRQ            INTRQ  INTRQ

If Error Status is presented, the drive is prepared to transfer data, and it
is at the host's discretion that the data is transferred.

10.1.2  PIO Read Aborted Command

+- a) -+-- b) -+        +- e) -+
|Setup | Issue |        | Read |
|      |Command|        |Status|
+------+-------+        +------+
|BSY=0 |       |BSY=1   |BSY=0 |
       |DRDY=1          |      |
                        |DRQ=1 |DRQ=0
                        |Assert|Negate
                         INTRQ  INTRQ

Although DRQ=1, there is no data to be transferred under this condition.

10.2  PIO Data Out Commands

This class includes:

- Format
- Write Buffer
- Write Long
- Write Sector(s)

Execution includes the transfer of one or more 512 byte (>512 bytes on Write
Long) sectors of data from the drive to the host.

a) The host writes any required parameters to the Features, Sector Count,
   Sector Number, Cylinder and Drive/Head registers.
b) The host writes the command code to the Command Register.
c) The drive sets DRQ when it is ready to accept the first sector of data.
d) The host writes one sector of data via the Data Register.
e) The drive clears DRQ and sets BSY.
f) When the drive has completed processing of the sector, it clears BSY and
   asserts INTRQ. If transfer of another sector is required, the drive also
   sets DRQ.
g) After detecting INTRQ, the host reads the Status Register.
h) The drive clears the interrupt.
i) If transfer of another sector is required, the above sequence is repeated
   from d).

10.2.1  PIO Write Command

+- a) -+-- b) -+      +--------+      +- e) -+--------+       +- e) -+
|Setup | Issue |      |Transfer|      | Read |Transfer|       | Read |
|      |Command|      |  Data  |      |Status|  Data  |:::::::|Status|
+------+-------+      +--------+      +------+--------+       +------+
|BSY=0 |       |BSY=1 |BSY=0   |BSY=1 |BSY=0 |        |BSY=1  |BSY=0 |
       |DRDY=1        |        |      |      |        |       |      |
                      |DRQ=1   |DRQ=0 |DRQ=1 |        |DRQ=0  |      |
                      |        |      |Assert|Negate  |       |Assert|Negate
                                       INTRQ  INTRQ            INTRQ  INTRQ

10.2.2  PIO Write Aborted Command

+- a) -+-- b) -+       +- e) -+
|Setup | Issue |       | Read |
|      |Command|       |Status|
+------+-------+       +------+
|BSY=0 |       |BSY=1  |BSY=0 |
       |DRDY=1         |      |
       |               |Assert|Negate
                        INTRQ  INTRQ

10.3  Non-Data Commands

This class includes:

- Execute Drive Diagnostic (DRDY=x)
- Idle
- Initialize Drive Parameters (DRDY=x)
- Read Power Mode
- Read Verify Sector(s)
- Recalibrate
- Seek
- Set Features
- Set Multiple Mode
- Standby

Execution of these commands involves no data transfer.

a) The host writes any required parameters to the Features, Sector Count,
   Sector Number, Cylinder and Drive/Head registers.
b) The host writes the command code to the Command Register.
c) The drive sets BSY.
d) When the drive has completed processing, it clears BSY and asserts INTRQ.
g) The host reads the Status Register.
h) The drive negates INTRQ.

10.4  Miscellaneous Commands

This class includes:

- Read Multiple
- Sleep
- Write Multiple
- Write Same

The protocol for these commands is contained in the individual command
descriptions.

10.5  DMA Data Transfer Commands (Optional)

This class comprises:

- Read DMA
- Write DMA

Data transfers using DMA commands differ in two ways from PIO transfers:

- data transfers are performed using the slave-DMA channel
- no intermediate sector interrupts are issued on multi-sector commands

Initiation of the DMA transfer commands is identical to the Read Sector or
Write Sector commands except that the host initializes the slave-DMA channel
prior to issuing the command.

The interrupt handler for DMA transfers is different in that:

- no intermediate sector interrupts are issued on multi-sector commands
- the host resets the DMA channel prior to reading status from the drive.

The DMA protocol allows high performance multi-tasking operating systems to
eliminate processor overhead associated with PIO transfers.

a) Command Phase
   1) Host initializes the slave-DMA channel
   2) Host updates the Command Block Registers
   3) Host writes command code to the Command Register
b) Data Phase - the register contents are not valid during a DMA Data Phase.
   1) The slave-DMA channel qualifies data transfers to and from the drive
      with DMARQ
c) Status Phase
   1) Drive generates the interrupt to the host
   2) Host resets the slave-DMA channel
   3) Host reads the Status Register and Error Register

10.5.1  Normal DMA Transfer

+--------------+-------+      +---------------------+  +---------+------+
|Initialize DMA|Command|      |  DMA Data Transfer  |  |Reset DMA|Status|
+--------------+-------+      +---------------------+  +---------+------+
|BSY=0                 |BSY=1 |BSY=x                   |BSY=1    |BSY=0
                              |DRQ=x                   |nIEN=0

10.5.2  Aborted DMA Transfer

+--------------+-------+      +-------------+  +---------+------+
|Initialize DMA|Command|      |    DMA Data |  |Reset DMA|Status|
+--------------+-------+      +-------------+  +---------+------+
|BSY=0                 |BSY=1 |BSY=x           |BSY=1    |BSY=0
                              |DRQ=1           |nIEN=0

10.5.3  Aborted DMA Command

+--------------+-------+      +---------+------+
|Initialize DMA|Command|      |Reset DMA|Status|
+--------------+-------+      +---------+------+
|BSY=0                 |BSY=1 |BSY=1    |BSY=0
                              |nIEN=0

11.  Timing

11.1  Deskewing

The host shall provide cable deskewing for all signals originating from the
controller. The drive shall provide cable deskewing for all signals
originating at the host.

11.2  Symbols

Certain symbols are used in the timing diagrams. These symbols and their
respective definitions are listed below.

/ or \    -  signal transition (asserted or negated) *
< or >    -  data transition (asserted or negated)
XXXXXX    -  undefined but not necessarily released
.  .  .   -  the "other" condition if a signal is shown with no change
  #n      -  used to number the sequence in which events occur e.g. #a, #b
  _ _ __
__/_ _/    -  a degree of uncertainty as to when a signal may be asserted

__ _ _
 \_ _\__  -  a degree of uncertainty as to when a signal may be negated

* All signals are shown with the Asserted condition facing to the top of
  the page. The negated condition is shown towards the bottom of the page
  relative to the asserted condition.

11.3  Terms

The interface uses a mixture of negative and positive signals for control and
data. The terms asserted and negated are used for consistency and are
independent of electrical characteristics.

In all timing diagrams, the lower line indicates negated, and the upper line
indicates asserted e.g. the following illustrates the representation of a
signal named TEST going from negated to asserted and back to negated, based on
the polarity of the signal.

                             Assert          Negate
                                  |          |
        Bit Setting=1             |__________|
        Bit Setting=0  TEST  _____/          \_______

                             Assert          Negate
                                  |          |
        Bit Setting=0             |__________|
        Bit Setting=1  TEST- _____/          \_______

11.4  Data Transfers

Figure 11-1 defines the relationships between the interface signals for both
16-bit and 8-bit data transfers.

                             |<------------ t0 -------------------->|
                       __________________________________________   |
Address Valid *1 ...../                                          \________
                      |<-t1->|                            ->| t9 |<-
                    ->|t7|<- |<----------- t2 ------------->|  ->|t8|<-
                      |  |   |______________________________|    |  |_____
DIOR-/DIOW-      ____________/                              \_______/
                      |  |   |_ _ _ _ _ _ _ _ _ _ _____________     |
Write Data Valid *2__________/_ _ _ _ _ _ _ _ _ _/             \__________
                      |  |   |                   |<--t3---->|  |
                      |  |   |                            ->|t4|<-  |
                      |  |   |_ _ _ _ _ _ _ _ _ _ _ ___________     |
Read Data Valid  *2__________/_ _ _ _ _ _ _ _ _ _ _/        |  \__________
                      |  |   |                     |<--t5-->|  |    |
                      |  |   |                            ->|t6|<-  |
                      |  |   |                              |  |    |
                      |  |__________________________________________|
IOCS16-          ________/                                          \_____

       *1  Drive Address consists of signals CS1FX-, CS3FX- and DA2-0
       *2  Data consists of DD0-15 (16-bit) or DD0-7 (8-bit)

     +------------------------------------------+-------+-------+-------+
     | PIO                                      | Mode 0| Mode 1| Mode 2|
     | Timing Parameters                        |  nsec |  nsec |  nsec |
+----+------------------------------------------+-------+-------+-------+
| t0 | Cycle Time                         (Min) |  600  |  383  |  240  |
| t1 | Address Valid to DIOR-/DIOW- Setup (Min) |   70  |   50  |   30  |
| t2 | DIOR-/DIOW-      16-bit            (Min) |  165  |  125  |  100  |
|    |   Pulse Width     8-bit            (Min) |  290  |  290  |  290  |
| t3 | DIOW- Data Setup                   (Min) |   60  |   45  |   30  |
| t4 | DIOW- Data Hold                    (Min) |   30  |   20  |   15  |
| t5 | DIOR- Data Setup                   (Min) |   50  |   35  |   20  |
| t6 | DIOR- Data Hold                    (Min) |    5  |    5  |    5  |
| t7 | Addr Valid to IOCS16- Assertion    (Max) |   90  |   50  |   40  |
| t8 | Addr Valid to IOCS16- Negation     (Max) |   60  |   45  |   30  |
| t9 | DIOR-/DIOW- to Address Valid Hold  (Min) |   20  |   15  |   10  |
+----+------------------------------------------+-------+-------+-------+

                FIGURE 11-1:  PIO DATA TRANSFER TO/FROM DRIVE

                       ___________________________________
DIOR-/DIOW- __________/                                   \______________
                      |
                      |<- tA ->|<---    tB    ---->|
            ___________________|                   |_____________________
IORDY                          \___________________/

Label               Description                          Min  Max  Units

tA  IORDY  Setup time                                     -     35 nsecs
tB  IORDY  Pulse Width                                    -  1,250 nsecs

 WARNING: The use of IORDY for data transfers is a system integration issue
          which requires control of both ends of the cable.

                 FIGURE 11-2:  IORDY TIMING REQUIREMENTS

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

                   |<----------------------- t0 ----------------------->|
                ____________                                         _______
DMARQ       ___/            \_______________________________________/   |
                   |<- tC ->|                                           |
                   |______________________________________________      |___
DMACK-      _______/                                              \_____/
                   |<--- tI --->|_________________|<----- tJ -----|     |
DIOR-/DIOW- ____________________/                 \_________________________
                   |            |                 |                     |
                   |            |<------ tD ----->|                     |
Read               |                      _________________             |
DD0-15      -----------------------------<_________________>----------------
                   |            |<- tE ->|<- tS ->|<- tF ->|            |
Write              |                  __________________________        |
DD0-15     --------------------------<__________________________>-----------
                   |                 |            |             |       |
                   |                 |<--- tG --->|<--  tH   -->|       |

         +----------------------------------+-------+-------+-------+
         | Single Word DMA                  | Mode 0| Mode 1| Mode 2|
         | Timing Parameters                |  nsec |  nsec |  nsec |
    +----+----------------------------------+-------+-------+-------+
    | t0 | Cycle Time                 (Min) |  960  |  480  |  240  |
    | tC | DMACK to DMREQ Delay       (Max) |  200  |  100  |   80  |
    | tD | DIOR-/DIOW-      16-bit    (Min) |  480  |  240  |  120  |
    | tE | DIOR- Data Access          (Max) |  250  |  150  |   60  |
    | tF | DIOR- Data Hold            (Min) |    5  |    5  |    5  |
    | tG | DIOW- Data Setup           (Min) |  250  |  100  |   35  |
    | tH | DIOW- Data Hold            (Min) |   50  |   30  |   20  |
    | tI | DMACK to DIOR-/DIOW- Setup (Min) |    0  |    0  |    0  |
    | tJ | DIOR-/DIOW- to DMACK Hold  (Min) |    0  |    0  |    0  |
    | tS | DIOR- Setup                (Min) | tD-tE | tD-tE | tD-tE |
    +----+----------------------------------+-------+-------+-------+
                FIGURE 11-3:  SINGLE WORD DMA DATA TRANSFER

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

                  |<-------------- t0 ---------------->|
           __________________________________________________            __
DMARQ  ___/                                                  \__________/
                  |                                    |<--->|
                  |                                    |  tL
              __________________________________________________
DMACK- ______/                                                  \_________/
             |<-->|         |                          |
               tI |<-- tD ->|<--------- tK ----------->|<- tJ ->|
                  |         |                          |
DIOR-             |_________|                          |_________
DIOW-  ___________/         \__________________________/         \_________

                  |<--->|   |
READ                 tE  ________                             ________
DD0-15 -----------------<________>---------------------------<________>----

                            |<-->|
                            | tF
WRITE                 ____________                         ____________
DD0-15 --------------<____________>-----------------------<____________>---

                     |<---->|<--->|
                        tG    tH

                    +----------------------------+-----------+
                    | Multiword DMA              |   Mode 0  |
                    | Timing Parameters          |    nsec   |
                    |                            | Min | Max |
              +-----+----------------------------+-----+-----+
              | t0  | Cycle Time                 | 480 |     |
              | tC  | DMACK to DMREQ Delay       |     | --- |
              | tD  | DIOR-/DIOW-      16-bit    | 215 |     |
              | tE  | DIOR- Data Access          |     | 150 |
              | tF  | DIOR- Data Hold            |   5 |     |
              | tF  | DIOR- Data Hold            |     |  20 |
              | tG  | DIOW- Data Setup           | 100 |     |
              | tH  | DIOW- Data Hold            |  20 |     |
              | tI  | DMACK to DIOR-/DIOW- Setup |   0 |     |
              | tJ  | DIOR-/DIOW- to DMACK Hold  |   0 |     |
              | tKr | DIOR- Negated Pulse Width  |  50 |     |
              | tKw | DIOW- Negated Pulse Width  | 215 |     |
              | tLr | DIOR- to DMREQ Delay       |     | 120 |
              | tLw | DIOW- to DMREQ Delay       |     |  40 |
              +-----+----------------------------+-----+-----+
                 FIGURE 11-4:  MULTIWORD DMA DATA TRANSFER

11.5 Power On and Hard Reset

             ______
RESET- _____/      \_____________________________________________________
            |<-tM->|
            |      |          Drive 0
         _ _ _ _ _ _ _ _______ _ _ _ _ _ _ _ _ _ _ _ _ _|
BSY      _ _ _ _ _ _ _/       \_ _ _ _ _ *1  _ _ _ _ _ _\________________
                 ->|tN|<-
         _ _ _ _ _ _ _ _         _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
DASP-    _ _ _ _ _ _ _ _\_______/_ _ _ _ *2 _ _ _ _ _ _ _ _ _ _\=== *3 ==
                 ->| tP |<-     |                       |_ _ _ __________
Control Registers_______________________________________/_ _ _ /
                   |  | |
                   |  | |     Drive 1
       _ _ _ _ _ _ _ _ _________________________________|
BSY    _ _ _ _ _ _ _ _/                                 \________________
        _ _ _ _ _ _ _ _ _ _                              ______ _ _ _ _ _
PDIAG-  _ _ _ _ _ _ _ _ _ _\____________________________/      \_ _ _ _ _
                   |  | |     |<----------- tQ -------->|
       _ _ _ _ _ _ _ _ _       _________________________ _ _ _
DASP-  _ _ _ _ _ _ _ _ _\_____/                         \ _ _ _\=== *3 ==
                   |<-  tR  ->|<------------ tS -------------->|
                                                         _ _ _ __________
Control Registers_______________________________________/_ _ _ /

    *1 Drive 0 can set BSY=0 if Drive 1 not present
    *2 Drive 0 can use DASP- to indicate it is active if Drive 1 is not
       present
    *3 DASP- can be asserted to indicate that the drive is active
                     +-------------------+------------+
                     | Label             |   Units    |
                     +-------------------+------------+
                     | tM         (Min)  |  25   usec |
                     | tN         (Max)  | 400   nsec |
                     | tP         (Max)  |   1   msec |
                     | tQ         (Max)  |  30   secs |
                     | tR Drive 0 (Max)  | 450   msec |
                     | tR Drive 1 (Max)  | 400   msec |
                     | tS         (Max)  |  30.5 secs |
                     +-------------------+------------+

                        FIGURE 11-5:  RESET SEQUENCE

Annex A: Diagnostic and Reset Considerations
        (informative).

This annex describes the following timing relationships during:

a) Power On and Hardware Resets
   - One drive
   - Two drives
b) Software Reset
   - One drive
   - Two drives
c) Diagnostic Command Execution
   - One drive
   - Two drives
   - Two drives - Drive 1 failed

The timing assumes the following:

o DASP- is asserted by Drive 1 and received by Drive 0 at power-on or
  hardware reset to indicate the presence of Drive 1. At all other times it
  is asserted by Drive 0 and Drive 1 to indicate when a drive is active.
o PDIAG- is asserted by Drive 1 and detected by Drive 0. It is used by
  Drive 1 to indicate to Drive 0 that it has completed diagnostics and is
  ready to accept commands from the Host (BSY bit is cleared). This does not
  indicate that the drive is ready, only that it can accept commands. This
  line may remain asserted until the next reset occurs or an Execute
  Diagnostic command is received.
o Unless indicated otherwise, all times are relative to the event that
  triggers the operation (RESET-, SRST=1, Execute Diagnostic Command).

A.1 Power On and Hardware Resets

A.1.1 Power On and Hardware Resets - One Drive

- Host asserts RESET- for a minimum of 25 usec.
- Drive 0 sets BSY within 400 nsecs after RESET- is negated.
- Drive 0 negates DASP- within 1 msec after RESET- negated.
- Drive 0 performs hardware initialization
- Drive 0 may revert to its default condition
- Drive 0 waits 1 msec then samples for at least 450 msec for DASP- to be
  asserted from Drive 1.
- Drive 0 clears BSY when ready to accept commands (within 31 seconds).

A.1.2  Power On and Hardware Resets - Two Drives

- Host asserts RESET- for a minimum of 25 usec.
- Drive 0 and Drive 1 set BSY within 400 nsec after RESET- negated.
- DASP- is negated within 1 msec after RESET- is negated.

A.1.2.1  Drive 1

- Drive 1 negates PDIAG- before asserting DASP-.
- Drive 1 asserts DASP- within 400 msecs after RESET- (to show presence).
- Drive 1 performs hardware initialization and executes its internal
  diagnostics.
- Drive 1 may revert to its default condition
- Drive 1 posts diagnostic results to the Error Register
- Drive 1 clears BSY when ready to accept commands.
- Drive 1 asserts PDIAG- to indicate that it is ready to accept commands
  (within 30 seconds from RESET-).
- Drive 1 negates DASP- after the first command is received or negates DASP-
  if no command is received within 30 seconds after RESET-.

A.1.2.2  Drive 0

- Drive 0 performs hardware initialization and executes its internal
  diagnostics.
- Drive 0 may revert to its default condition
- Drive 0 posts diagnostic results to the Error Register
- After 1 msec, Drive 0 waits at least 450 msec for DASP- to be asserted
  (from Drive 1). If DASP- is not asserted, no Drive 1 is present (see POWER-
  ON RESET - One Drive operation).
- Drive 0 waits up to 31 seconds for Drive 1 to assert PDIAG-. If PDIAG- is
  not asserted, Drive 0 sets Bit 7=1 in the Error Register.
- Drive 0 clears BSY when ready to accept commands (within 31 seconds).

A.2  Software Reset

A.2.1  Software Reset - One Drive

- Host sets SRST=1 in the Device Control Register.
- Drive 0 sets BSY within 400 nsec after detecting that SRST=1.
- Drive 0 performs hardware initialization and executes its internal
  diagnostics.
- Drive 0 may revert to its default condition.
- Drive 0 posts diagnostic results to the Error Register.
- Drive 0 clears BSY when ready to accept commands (within 31 seconds).

A.2.2  Software Reset - Two Drives

- Host sets SRST=1 in the Device Control Register.
- Drive 0 and Drive 1 set BSY within 400 nsec after detecting that SRST=1.
- Drive 0 and Drive 1 perform hardware initialization.
- Drive 0 and Drive 1 may revert to their default condition.

A.2.2.1  Drive 1

- Drive 1 negates PDIAG- within 1 msec.
- Drive 1 clears BSY when ready to accept commands.
- Drive 1 asserts PDIAG- to indicate that it is ready to accept commands
  (within 30 seconds).

A.2.2.2  Drive 0

- Drive 0 waits up to 31 seconds for Drive 1 to assert PDIAG-.
- Drive 0 clears BSY when ready to accept commands (within 31 seconds).

A.3  Diagnostic Command Execution

A.3.1  Diagnostic Command Execution - One Drive (Passed)

- Drive 0 sets BSY within 400 nsec after the Execute Diagnostic command was
  received.
- Drive 0 performs hardware initialization and internal diagnostics.
- Drive 0 resets Command Block registers to default condition.
- Drive 0 posts diagnostic results to the Error Register
- Drive 0 clears BSY when ready to accept commands (within 6 seconds).

A.3.2  Diagnostic Command - Two Drives (Passed)

- Drive 0 and Drive 1 set BSY within 400 nsec after the Execute Diagnostic
  command was received.

A.3.2.1  Drive 1

- Drive 1 negates PDIAG- within 1 msec after command received.
- Drive 1 performs hardware initialization and internal diagnostics.
- Drive 1 resets the Command Block registers to their default condition.
- Drive 1 posts diagnostic results to the Error Register
- Drive 1 clears BSY when ready to accept commands.
- Drive 1 asserts PDIAG- to indicate that it is ready to accept commands
  (within 5 seconds).

A.3.2.2  Drive 0

- Drive 0 performs hardware initialization and internal diagnostics.
- Drive 0 resets the Command Block registers to their default condition.
- Drive 0 waits up to <5 seconds for Drive 1 to assert PDIAG-.
- Drive 0 posts diagnostic results to the Error Register
- Drive 0 clears BSY when ready to accept commands (within 6 seconds).

A.3.3  Diagnostic Command Execution - One Drive (Failed)

- Drive 0 sets BSY within 400 nsec after Diagnostic command received.
- Drive 0 performs hardware initialization and internal diagnostics.
- Drive 0 resets Command Block registers to default condition.
- Drive 0 posts a Diagnostic Code to the Error Register indicating a failure.
- Drive 0 clears BSY when ready to accept commands (within 6 seconds)

A.3.4  Diagnostic Command Execution - Two Drives (Drive 1 Failed)

- Drive 0 and Drive 1 set BSY within 400 nsec after Diagnostic command
  received.

A.3.4.1  Drive 1

- Drive 1 negates PDIAG- within 1 msec after command received.
- Drive 1 performs hardware initialization and internal diagnostics.
- Drive 1 resets the Command Block registers to their default condition.
- Drive 1 posts a Diagnostic Code to the Error Register indicating failure.
- Drive 1 clears BSY.
- Drive 1 does not assert PDIAG-, indicating that it failed diagnostics.

A.3.4.2  Drive 0

- Drive 0 performs hardware initialization and internal diagnostics.
- Drive 0 resets the Command Block registers to their default condition.
- Drive 0 waits 6 seconds for Drive 1 to assert PDIAG- but PDIAG- is not
  asserted by Drive 1.
- Drive 0 posts a Diagnostic Code to the Error Register setting Bit 7=1 to
  indicate that Drive 1 failed diagnostics.
- Drive 0 clears BSY when ready to accept commands (within 6 seconds).

 NOTE: The 6 seconds referenced above is a host-oriented value.

Annex B: Diagnostic and Reset Considerations
        (informative).

B.1  Power on and hardware reset (RESET-)

DASP- is read by Drive 0 to determine if Drive 1 is present. If Drive 1 is
present Drive 0 will read PDIAG- to determine when it is valid to clear BSY
and whether Drive 1 has powered on or reset without error, otherwise Drive 0
clears BSY whenever it is ready to accept commands. Drive 0 may assert DASP-
to indicate drive activity.

B.2  Software reset

If Drive 1 is present Drive 0 will read PDIAG- to determine when it is valid
to clear BSY and whether Drive 1 has reset without any errors, otherwise
Drive  0 will simply reset and clear BSY.  DASP- is asserted by Drive 0 (and
Drive 1 if it is present) in order to indicate drive active.

B.3  Drive Diagnostic Command

If Drive 1 is present, Drive 0 will read PDIAG- to determine when it is valid
to clear BSY and if Drive 1 passed or failed the Execute Drive Diagnostic
command, otherwise Drive 0 will simply execute its diagnostics and then clear
BSY.  DASP- is asserted by Drive 0 (and Drive 1 if it is present) in order to
indicate the drive is active.

B.4  Truth Table

In all the above cases:  Power on, RESET-, software reset, and the Execute
Drive Diagnostics command the Drive 0 Error Register is calculated as follows:

       Drive 1           PDIAG-         Drive 0         Error
       Present?        Asserted?        Passed        Register

         Yes             Yes             Yes           01h
         Yes             Yes              No           0xh
         Yes              No             Yes           81h
         Yes              No              No           8xh
          No           (not read)        Yes           01h
          No           (not read)         No           0xh

Where x indicates the appropriate Diagnostic Code for the Power on, RESET-,
software reset, or drive diagnostics error.

B.5  Power On or Hardware Reset Algorithm

1) Power on or hardware reset
2) The hardware should automatically do the following:
        a) Set up the hardware to post both Drive 0 and Drive 1 status
        b) Set the Drive 0 Status Register to 80h (set BSY and clear
           all the other status bits)
        c) Set the Drive 1 Status Register to 80h (set BSY and clear all
           the other status bits)
3) Read the single Drive 0/Drive 1 jumper and note its state
4) Perform any remaining time critical hardware initialization including
   starting the spin up of the disk if needed
5) If Drive 1
        a) Negate the PDIAG- signal
        b) Set up PDIAG- as an output
        c) Assert the DASP- output
        d) Set up DASP- as an output if necessary
        e) Set up the hardware so it posts Drive 1 status only and
           continue to post 80h for Drive 1 status
        NOTE: all this must happen within 400 msec after power on or RESET-
   If Drive 0
        a) Set up PDIAG- as an input
        b) Release DASP- and set up DASP- as an input
        c) Test DASP- for 450 msec or until DASP- is asserted by Drive 1
        d) If DASP- is asserted within 450 msec
                i)   Note that Drive 1 is present
                ii)  Set up the hardware so it posts Drive 0 status only
                     and continue to post 80h for the Drive 0 status
           If DASP- is not asserted within 450 msec
                   i)   note that Drive 1 is not present
        e) Assert DASP- to indicate drive activity
6) Complete all the hardware initialization needed to get the drive ready,
   including:
        a) Set the Sector Count Register to 01h
        b) Set the Sector Number Register to 01h
        c) Set the Cylinder Low Register to 00h
        d) Set the Cylinder High Register to 00h
        e) Set the Drive/Head Register to 00h
7) If Drive 1 and power on, or RESET- is valid
        a) Set the Error Register to Diagnostic Code 01h
        b) Set the Drive 1 Status Register to 00h
        c) Assert PDIAG-
        NOTE:  All this must happen within 5 seconds of power on or the
               negation of RESET-
   If Drive 1 and power on or RESET- bad
        a) Set the Error Register to the appropriate Diagnostic Code
        b) Set the Drive 1 Status Register to 00h
        NOTE:  All this must happen within 5 seconds of power on or the
               negation of RESET-
   If Drive 0, power on or RESET- valid, and a Drive 1 is present
        a) Test PDIAG- for 6 seconds or until PDIAG- is asserted by Drive 1
        b) If PDIAG- is asserted within 6 seconds
                i)  Set the Error Register to Diagnostic Code 01h
        c) If PDIAG- is not asserted within 6 seconds
                i)  Set the Error Register to 81h
        d) Set the Drive 0 Status Register to 00h
   If Drive 0, power on or RESET- bad, and a Drive 1 is present
        a) Test PDIAG- for 6 seconds or until PDIAG- is asserted by
           Drive 1
        b) If PDIAG- is asserted within 6 seconds
                i)  Set the Error Register to the appropriate Diagnostic Code
        c) If PDIAG- is not asserted within 6 seconds
                i)  Set the Error Register to 80h + the appropriate code
        d) Set the Drive 0 Status Register to 00h
   If Drive 0, power on or RESET- valid, and no Drive 1 is present
        a) Set the Error Register to Diagnostic Code 01h
        b) Set the Drive 1 Status Register to 00h
        c) Set the Drive 0 Status Register to 00h
   If Drive 0, power on or RESET- bad, and no Drive 1 is present
        a) Set the Error Register to the appropriate Diagnostic Code
        b) Set the Drive 1 Status Register to 00h
        c) Set the Drive 0 Status Register to 00h
8) Finish spin up if needed
9) If Drive 1
        a) Set the Drive 1 Status Register to 50h
        b) Negate DASP- if a command is not received within 30 seconds
   If Drive 0 and a Drive 1 is present
        a) Set the Drive 0 Status Register to 50h
        b) Negate DASP-
   If Drive 0 and no Drive 1 is present
        a) Leave the Drive 1 Status Register 00h
        b) Set the Drive 0 Status Register to 50h
        c) Negate DASP-

B.6  Software Reset Algorithm

1) The software reset bit is set
2) If Drive 1
        a) The hardware should set BUSY in the Drive 1 Status Register
        b) Negate the PDIAG- signal
        NOTE: this must happen within 1 msec of the software reset
   If Drive 0 and Drive 1 is present
           a) The hardware should set BUSY in the Drive 0 Status Register
   If Drive 0 and there is no Drive 1 the hardware should:
           a) Set BUSY in the Drive 0 Status Register
        b) Set the Drive 1 Status Register to 80h
3) Assert DASP-
4) Finish all the hardware initialization needed to place the drive in reset
5) Wait for the software reset bit to clear
6) Finish all hardware initialization needed to get the drive ready
   to receive any type of command from the host including:
        a) Set the Sector Count Register to 01h
        b) Set the Sector Number Register to 01h
        c) Set the Cylinder Low Register to 00h
        d) Set the Cylinder High Register to 00h
        e) Set the Drive/Head Register to 00h
7) If Drive 1 and reset valid
        a) Set the Error Register to Diagnostic Code 01h
        b) Set the Drive 1 Status Register to 50h
        c) Assert PDIAG-
        NOTE:  All this must happen within 5 seconds of the clearing of
               the software reset bit
   If Drive 1 and reset bad
        a) Set the Error Register to the appropriate Diagnostic Code
        b) Set the Drive 1 Status Register to 50h
        NOTE:  All this must happen within 5 seconds of the clearing of
               the software reset bit
   If Drive 0, reset valid, and a Drive 1 is present
           a) Test PDIAG- for 6 seconds or until PDIAG- is asserted by
           Drive 1
           b) If PDIAG- is asserted within 6 seconds
                i)  Set the Error Register to Diagnostic Code 01h
        c) If PDIAG- is not asserted within 6 seconds
                i)  Set the Error Register to 81h
        d) Set the Drive 0 Status Register to 50h
   If Drive 0, reset bad, and a Drive 1 is present
           a) Test PDIAG- for 31 seconds or until PDIAG- is asserted by
           Drive 1
           b) If PDIAG- is asserted within 31 seconds
                i)  Set the Error Register to the appropriate Diagnostic Code
        c) If PDIAG- is not asserted within 31 seconds
                i)  Set the Error Register to 80h + the appropriate code
        d) Set the Drive 0 Status Register to 50h
   If Drive 0, reset valid, and no Drive 1 is present
           a) Set the Error Register to Diagnostic Code 01h
        b) Set the Drive 1 Status Register to 00h
           c) Set the Drive 0 Status Register to 50h
   If Drive 0, reset bad, and no Drive 1 is present
           a) Set the Error Register to the appropriate Diagnostic Code
        b) Set the Drive 1 Status Register to 00h
           c) Set the Drive 0 Status Register to 50h

B.7  Diagnostic Command Algorithm

1) The diagnostics command is received
2) If Drive 1
        a) The hardware should set BUSY in the Drive 1 Status Register
        b) Negate the PDIAG- signal
        NOTE: this must happen within 1 msec after command acceptance
   If Drive 0 and Drive 1 is present
           a) The hardware should set BUSY in the Drive 0 Status Register
   If Drive 0 and there is no Drive 1 the hardware should
           a) Set BUSY in the Drive 0 Status Register
        b) Set BUSY in the Drive 1 Status Register
3) Assert DASP-
4) Perform all the drive diagnostics and note their results
5) Finish all the hardware initialization needed to get the drive ready
   to receive any type of command from the host including:
        a) Set the Sector Count Register to 01h
        b) Set the Sector Number Register to 01h
        c) Set the Cylinder Low Register to 00h
        d) Set the Cylinder High Register to 00h
        e) Set the Drive/Head Register to 00h
6) If Drive 1 and passed
        a) Set the Error Register to Diagnostic Code 01h
        b) Set the Drive 1 status to 50h
        c) Assert PDIAG-
        NOTE:  All this must happen within 5 seconds of the acceptance
               of the diagnostic command
   If Drive 1 and did not pass
           a) Set the Error Register to the appropriate Diagnostic Code
        b) Set the Drive 1 status to 50h
        NOTE:  All this must happen within 5 seconds of the acceptance
               of the diagnostic command
   If Drive 0, passed, and a Drive 1 is present
           a) Test PDIAG- for 6 seconds or until PDIAG- is asserted by
           Drive 1
           b) If PDIAG- is asserted within 6 seconds
                i)  Set the Error Register to Diagnostic Code 01h
        c) If PDIAG- is not asserted within 6 seconds
                i)  Set the Error Register to 81h
        d) Set the Drive 0 status to 50h
        e) Issue interrupt to the host
   If Drive 0, did not pass, and a Drive 1 is present
        a) Test PDIAG- for 6 seconds or until PDIAG- is asserted by Drive 1
        b) If PDIAG- is asserted within 6 seconds
                i)  Set the Error Register to the appropriate Diagnostic Code
        c) If PDIAG- is not asserted within  seconds
                i)  Set the Error Register to 80h + the appropriate code
        d) Set the Drive 0 Status Register to 50h
        e) Issue interrupt to the host
   If Drive 0, passed, and no Drive 1 is present
        a) Set the Error Register to Diagnostic Code 01h
        b) Set the Drive 1 Status Register to 00h
        c) Set the Drive 0 Status Register to 50h
        d) Issue interrupt to the host
   If Drive 0, did not pass, and no Drive 1 is present
        a) Set the Error Register to the appropriate Diagnostic Code
        b) Set the Drive 1 Status Register to 00h
        c) Set the Drive 0 Status Register to 50h
        d) Issue interrupt to the host

Annex C: Small Form Factor Connectors
        (informative).

This annex describes the connector-connector mating alternatives for 2 1/2"
disk drives or smaller which were developed by the Small Form Factor (SFF)
Committee, an industry ad hoc group.

In an effort to broaden the applications for small form factor disk drives, a
group of companies representing system integrators, peripheral suppliers, and
component suppliers decided to address the issues involved.

A primary purpose of the SFF Committee was to define the external dimensions
of small form factor disk drives so that products from different vendors could
be used in the same mounting configurations.

The restricted area, and the mating of drives directly to a motherboard
required that the number of connectors be reduced, which caused the assignment
of additional pins for power. Power is provided to the drives on the same
connector as used for the signals, and addresses are set by the receptacle
into which the drives are plugged.

The 50-pin connector that has been widely adopted across industry for SFF
drives is a low density 2mm connector which has no shroud on the plug which is
mounted on the drive. A number of suppliers provide intermatable components.
The following information has been provided to assist users in specifying
components used in an implementation.

     Signals Connector Plug               DuPont 86451 or equivalent
     Signals Connector Receptacle         DuPont 86455 or equivalent

C.1  44-pin Signal Assignments

The signals assigned for 44-pin applications are described in Table C-1.
Although there are 50 pins in the plug, the mating receptacle need contain
only 44 pins (the removal of pins E and F provides room for the wall of the
receptacle).

44-pin Signal Assignments for ATA

The first four pins of the connector plug located on the drive are not to be
connected to the host, as they are reserved for manufacturer's use. Pins E,
F and K are keys, and are removed.

           +-------------------------------------------1-E-----+
           | o o o o o o o o o o o o o o o o o o o o o o K C A |
           | o o o o o o o o o o o o K o o o o o o o o o K D B |
           +44----------------------20-----------------2-F-----+

                   TABLE C-1  SIGNAL ASSIGNMENTS FOR ATA
======================================================================
     Signal        Connector              Connector      Signal
      Name          Contact   Conductor    Contact        Name
======================================================================
    Vendor Unique      A                      B         Vendor Unique
    Vendor Unique      C                      D         Vendor Unique
    (keypin)           E                      F         (keypin)
    RESET-             1        1 |  2        2         Ground
    DD7                3        3 |  4        4         DD8
    DD6                5        5 |  6        6         DD9
    DD5                7        7 |  8        8         DD10
    DD4                9        9 | 10       10         DD11
    DD3               11       11 | 12       12         DD12
    DD2               13       13 | 14       14         DD13
    DD1               15       15 | 16       16         DD14
    DD0               17       17 | 18       18         DD15
    Ground            19       19 | 20       20         (keypin)
    DMARQ             21       21 | 22       22         Ground
    DIOW-             23       23 | 24       24         Ground
    DIOR-             25       25 | 26       26         Ground
    IORDY             27       27 | 28       28         PSYNC:CSEL
    DMACK-            29       29 | 30       30         Ground
    INTRQ             31       31 | 32       32         IOCS16-
    DA1               33       33 | 34       34         PDIAG-
    DAO               35       35 | 36       36         DA2
    CS1FX-            37       37 | 38       38         CS3FX-
    DASP-             39       39 | 40       40         Ground
 *  +5V (Logic)       41       41 | 42       42         +5V (Motor)     *
 *  Ground (Return)   43       43 | 44       44         TYPE- (0=ATA)   *
        * Pins which are additional to those of the 40-pin cable.
======================================================================