Subj : SEXPOTS - Pulling my hair out... :)
To : cafarmer
From : Digital Man
Date : Sun Jun 09 2024 02:18 pm
Re: SEXPOTS - Pulling my hair out... :)
By: cafarmer to Digital Man on Sun Jun 09 2024 08:06 am
> My apologies on where I posted this. I click on the "go here" link and just
> started poking around not realizing you probably dropped me right where I
> needed to ask my question. We can move this if it makes more sense.
>
> I will try to answer the responses in order asked:
>
> 1. As far as I can tell, this is the latest version of SEXPOTS taken from
> the latest install v1.32-Win32
The latest is v2.0
> 2. The first two string I tried was the default one, AT&F and then ATZ.
> Neither would allow the modem to wait... it immediately detected carrier and
> tried to connect to the TCP host without an actual incoming call.
ATZ loads whatever setting you have saved in the modem's NVRAM (stored with AT&W).
> 3. For the Hayes Smartmodem 1200, I cannot get it to communicate (DTE) to
> the modem with anything higher than 1200 baud via Hyperterminal on Windows
Yeah, that would be expected for older modems like that.
> 7. (for now, I am focusing this issue with the HSM 1200, I will take what I
> learn and try to apply it to the HSM Optima 288 later. It may be that the
> HSM 1200 didn't support a DTE speed higher than the analog side of the
> connection (I can't remember what to call modem-modem connectivity - DCE?)?
Yeah, those old (2400 and slower) modems without error correction usually expecte DTE rate the same as their highest connect (DCE) rate supported. But I would read the manual to know for usre.
> 4. DTR? Not sure, I will have to look into that and how it might be
> affecting the connection.
Data terminal ready.
> 5. I have tried so many HSM 1200 init strings proposed out there. None of
> them were a "silver bullet". (again, just focusing on the 1200 for now).
I would start with the newer modem, myself.
> 6. No, neither of these modems seem to support Caller ID, but I couldn't
> figure out a way to bypass the attempt to set it.
Set the Caller-ID string to blank.
> A lot of this stuff is not new to me - I used to configure modem banks for a
> financial institution back in the early 90's (91-93). But it was a long time
> ago and yes, sometime I struggled with some of the newer Microcom modems -
> but really it was just me trying to squeeze every last drop of speed vs.
> performance I could get for the originators out in the field.
>
> Thank you very much for your responses as I work through this thing.
>
> I see your Steven Wright and raise you a Jack Handy:
>
> "If a kid asks where rain comes from, I think a cute thing to tell him is
> "God is crying." And if he asks why God is crying, another cute thing to
> tell him is "probably because of something you did."
:-)
--
digital man (rob)
Rush quote #86:
Follow men's eyes as they look to the skies .. Jacob's Ladder
Norco, CA WX: 74.0�F, 62.0% humidity, 3 mph WSW wind, 0.00 inches rain/24hrs