Development of an amplicon-based sequencing approach in response to the global emergence of mpox [1]

['Nicholas F. G. Chen', 'Department Of Epidemiology Of Microbial Diseases', 'Yale School Of Public Health', 'New Haven', 'Connecticut', 'United States Of America', 'Chrispin Chaguza', 'Luc Gagne', 'Massachusetts Department Of Public Health', 'Jamaica Plain']

Date: 2023-06

Abstract The 2022 multicountry mpox outbreak concurrent with the ongoing Coronavirus Disease 2019 (COVID-19) pandemic further highlighted the need for genomic surveillance and rapid pathogen whole-genome sequencing. While metagenomic sequencing approaches have been used to sequence many of the early mpox infections, these methods are resource intensive and require samples with high viral DNA concentrations. Given the atypical clinical presentation of cases associated with the outbreak and uncertainty regarding viral load across both the course of infection and anatomical body sites, there was an urgent need for a more sensitive and broadly applicable sequencing approach. Highly multiplexed amplicon-based sequencing (PrimalSeq) was initially developed for sequencing of Zika virus, and later adapted as the main sequencing approach for Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2). Here, we used PrimalScheme to develop a primer scheme for human monkeypox virus that can be used with many sequencing and bioinformatics pipelines implemented in public health laboratories during the COVID-19 pandemic. We sequenced clinical specimens that tested presumptively positive for human monkeypox virus with amplicon-based and metagenomic sequencing approaches. We found notably higher genome coverage across the virus genome, with minimal amplicon drop-outs, in using the amplicon-based sequencing approach, particularly in higher PCR cycle threshold (Ct) (lower DNA titer) samples. Further testing demonstrated that Ct value correlated with the number of sequencing reads and influenced the percent genome coverage. To maximize genome coverage when resources are limited, we recommend selecting samples with a PCR Ct below 31 Ct and generating 1 million sequencing reads per sample. To support national and international public health genomic surveillance efforts, we sent out primer pool aliquots to 10 laboratories across the United States, United Kingdom, Brazil, and Portugal. These public health laboratories successfully implemented the human monkeypox virus primer scheme in various amplicon sequencing workflows and with different sample types across a range of Ct values. Thus, we show that amplicon-based sequencing can provide a rapidly deployable, cost-effective, and flexible approach to pathogen whole-genome sequencing in response to newly emerging pathogens. Importantly, through the implementation of our primer scheme into existing SARS-CoV-2 workflows and across a range of sample types and sequencing platforms, we further demonstrate the potential of this approach for rapid outbreak response.

Citation: Chen NFG, Chaguza C, Gagne L, Doucette M, Smole S, Buzby E, et al. (2023) Development of an amplicon-based sequencing approach in response to the global emergence of mpox. PLoS Biol 21(6): e3002151. https://doi.org/10.1371/journal.pbio.3002151 Academic Editor: Bill Sugden, University of Wisconsin-Madison, UNITED STATES Received: January 12, 2023; Accepted: May 5, 2023; Published: June 13, 2023 Copyright: © 2023 Chen et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Data Availability: Genomic data are available on NCBI Sequence Read Archive (SRA), GenBank, and GISAID (see accession numbers in S3 Table). All other data are included in the manuscript and the Supporting Information. Funding: This publication was made possible by CTSA Grant Number UL1 TR001863 from the National Center for Advancing Translational Science (NCATS), a component of the National Institutes of Health (NIH) awarded to CBFV. INSA was partially funded by the HERA project (Grant/2021/PHF/23776) supported by the European Commission through the European Centre for Disease Control (to VB). The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript. Competing interests: I have read the journal’s policy and the authors of this manuscript have the following competing interests: NDG is a consultant for Tempus Labs and the National Basketball Association for work related to COVID-19. All other authors have declared that no competing interests exist. Abbreviations: CDPH, Connecticut Department of Public Health; CEVS, Centro Estadual de Vigilância em Saúde; COVID-19, Coronavirus Disease 2019; Ct, cycle threshold; DPHL, Delaware Public Health Lab; FDA, US Food and Drug Administration; FDH, Florida Department of Health; IBL, Idaho Bureau of Laboratories; INSA, National Institute of Health Dr. Ricardo Jorge; JHMI, Johns Hopkins Medical Institutions; LACPHL, Los Angeles County Public Health Lab; LMIC, low- or middle-income country; MASPHL, Massachusetts State Public Health Laboratory; MDH, Minnesota Department of Health; NHS Lothian, National Health Service Lothian; RIDOH RISHL, Rhode Island Department of Health/Rhode Island State Health Laboratory; SARS‑CoV‑2, Severe Acute Respiratory Syndrome Coronavirus 2; YSPH, Yale School of Public Health

Introduction The integration of pathogen whole-genome sequencing with public health surveillance provides a powerful tool to inform outbreak control [1,2]. While the feasibility of real-time genomic surveillance was demonstrated during the 2013 to 2016 Ebola outbreak [3], the Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) pandemic has launched a revolution in viral genomics [4]. To date, more than 14 million SARS-CoV-2 genomes have been sequenced and shared publicly [5], furthering our understanding of viral transmission and evolution. The rapid advancement in pathogen genomics in public health laboratories was facilitated in the United States through significant investments by the Centers of Disease Control and Prevention’s Office of Advanced Molecular Detection. These programs situated sequencing equipment in state and local public health laboratories and provided practical training in laboratory and bioinformatics approaches to allow for the rapid adoption of new sequencing methods. As the Coronavirus Disease 2019 (COVID-19) pandemic remains ongoing, the recent spread of human monkeypox virus outside of endemic areas has provided a new target for genomic surveillance efforts [6]. Monkeypox is a zoonotic DNA virus of the Orthopox genus endemic to Western and Central Africa [7]. The virus consists of 3 major clades (I, IIa, and IIb), with a subgroup of clade IIb being referred to as human monkeypox virus due to direct transmission from human to human [8]. Initially rare outside endemic countries beyond imported cases, mpox has emerged as a global threat. It was first detected in the United Kingdom on May 7, 2022, quickly spreading to other continents through travel-related infections and sometimes unknown transmission chains [9]. As of January 5, 2023, 84,075 cases of mpox across 103 non-endemic countries have been reported, often with atypical clinical presentations [6,10]. The lack of consistent clinical presentations, unknown transmission dynamics, and uncertainty surrounding animal reservoirs highlights the importance of establishing rapid genomic surveillance networks. Much of the early human monkeypox virus sequencing during the 2022 global outbreak has been accomplished via a metagenomics approach [9], which employs sequencing of the total nucleic acid present in a sample. While considered the gold standard for untargeted sequencing, metagenomics incurs a high resource cost, requires experienced sequencing and bioinformatics teams, is computationally demanding, and relies on samples with high viral concentrations relative to background nucleic acids [11]. The initial metagenomic approaches included hybrid assemblies of both long and short read sequencing to allow for high confidence and polishing of the early genomes. Although this was important to establish reference genomes, it comes at the cost of being able to sequence larger numbers of specimens [12]. These characteristics of metagenomic sequencing make the approach less suitable for rapid response to large-scale pathogen outbreaks, which require low-cost, rapidly deployable solutions able to be implemented across a range of settings, sample types, and experience levels. Highly multiplexed amplicon-based sequencing (PrimalSeq) was initially developed to generate greater coverage and depth for Zika virus genomes [13] and was later adapted as the main sequencing approach during the SARS-CoV-2 pandemic for both Illumina and Oxford Nanopore Technologies sequencing platforms [14]. Here, we developed a primer scheme for human monkeypox virus using PrimalScheme for use with amplicon-based sequencing workflows widely established during the COVID-19 pandemic. We show a consistently high percent or complete genome coverage across a range of PCR cycle threshold (Ct) values, with different workflows and sequencing platforms. Our amplicon-based sequencing approach provides a more sensitive, lower cost, and higher throughput strategy that can be “plugged” into currently established genomic infrastructure, providing an invaluable tool for public health surveillance of human monkeypox virus.

Discussion We developed an amplicon-based sequencing approach for human monkeypox virus to provide a more sensitive, lower cost, and higher throughput alternative to metagenomic sequencing. We used PrimalScheme to develop primers for human monkeypox virus based on a pre-outbreak A.1 lineage genome (GenBank accession: MT903345) and tested the primer scheme with clinical specimens in 2 independent laboratories. After initial validation, we shared primer pool aliquots with 10 additional public health laboratories, who successfully implemented the scheme in their existing amplicon-based sequencing workflows. Our findings showed greater breadth and depth of genome coverage when using the amplicon-based sequencing approach as compared to metagenomics, particularly for specimens with lower DNA concentrations. We identified Ct value and number of sequencing reads as 2 factors that influence percent genome coverage. Based on our findings, we made the following recommendations for amplicon-based sequencing of human monkeypox virus: Utilize existing amplicon-based SARS-CoV-2 sequencing infrastructure. Prioritize samples with a Ct value <31, if resources are limited. Generate at least 1 million sequencing reads per sample, if resources allow. Importantly, our human monkeypox virus primer scheme can be used with currently implemented SARS-CoV-2 sequencing workflows and Illumina or Oxford Nanopore Technologies sequencing platforms. This will enable laboratories that are currently using amplicon-based sequencing approaches for SARS-CoV-2 to expand their portfolio by including human monkeypox virus, with minimal change to their overall sequencing and bioinformatics workflow. By collaborating with 10 public health labs across the world, we show that this approach can be independently and effectively implemented across a range of settings, experience levels, and resource demands. Notably, this approach could see widespread adoption among low- or middle-income countries (LMICs), many of which saw rapid expansion of their sequencing infrastructure during the COVID-19 pandemic [21,22]. Indeed, one of the few positive developments of the pandemic has been the implementation of standardized genomic surveillance systems in LMICs, evident by the number of SARS-CoV-2 genomes submitted to genome databases from countries that previously lacked the capability for large-scale whole-genome sequencing. By utilizing many of the same sequencing resources (e.g., reagents, equipment, and bioinformatics pipelines) developed for use with SARS-CoV-2, our approach could provide a streamlined approach for genomic surveillance to aid LMICs in capacities ranging from case confirmations to outbreak response while placing little to no additional demands on resources. In particular, the outsourcing of traditionally computationally intensive workflows via the Terra platform and the ease of updating both the primer scheme and bioinformatics pipelines with our approach removes some of the barriers typically seen with implementing genomic surveillance in low-resource settings. The comparatively steep drop-off in genome coverage with higher PCR Ct samples seen with metagenomics reinforces a limitation of this sequencing approach found in other studies that used clinical metagenomics for pathogen sequencing [23]. This lack of sensitivity presents a potential challenge to genomic surveillance, as human monkeypox virus DNA concentrations fluctuate throughout the course of infection and across specimen types [24]. We show that high genome coverage can be achieved with different workflows, sequencing platforms, and sample types such as lesion and oropharyngeal swabs. The higher sensitivity seen in amplicon-based sequencing allows for sequencing of a larger variety of sample types across a wider range of Ct values compared to metagenomic sequencing. Given the large number (163) of amplicons needed to span the entire human monkeypox virus genome, there was an increased potential for amplicon drop-outs and a resulting reduction in genome coverage. Despite being an inherent risk of amplicon sequencing, here we identified only 2 amplicons (75 and 118) with consistent low coverage <10×, and an additional 8 amplicons with overall lower coverage. Moreover, we show that none of the sites associated with clade- and lineage-defining mutations have consistently low coverage. The lower coverage is likely the result of lower amplification efficiency and may be improved by further optimization to achieve high PCR efficiency across all the primer sets. As a double-stranded DNA virus with genetic proofreading mechanisms, the monkeypox virus has a comparatively slower evolutionary rate than single-stranded RNA viruses [25]. Less genetic diversity over time translates to fewer differences between the reference genome used to generate the primer scheme and genomes that are associated with the 2022 outbreak (clade IIb), decreasing the risk for amplicon drop-out. As a result, the primer scheme may not have to be updated as frequently as, for example, the primer scheme used to sequence SARS-CoV-2, but iterative updates can be released if needed [14]. As our primer scheme was specifically developed for clade IIb viruses, additional primer schemes may be needed for surveillance of other virus clades, such as those present in endemic regions. While we show consistently high coverage of the clade I and clade IIa defining genome sites, as well as high coverage for the majority of sites within sub-clade A.1, our primer scheme may not be able to generate sufficiently high coverage (>80%) of genomes belonging to these clades necessary for genomic surveillance. The intended use for this amplicon-based sequencing approach is for public health surveillance and it is not intended as a diagnostic assay. As such, we did not evaluate cross-reactivity with other orthopoxviruses. Similarly to the genomic surveillance systems used for SARS-CoV-2, sequencing should be performed with confirmed positive cases to generate data used to guide public health responses. While we did not test this approach with other orthopoxviruses, if they were to be present in a sample and able to be partially amplified, then it would be evident in the bioinformatics analysis and could serve as an additional use case for this approach. Public health surveillance has been implemented to understand factors that may have contributed to the rapid global spread of human monkeypox virus in 2022 [26], including evidence for human adaptation driven by the APOBEC3 enzyme [12]. In outbreak settings, whole-genome sequencing can be used to detect the introduction of new lineages, identify mutations associated with phenotypic adaptations, assess transmission dynamics and intervention effectiveness, and guide clinical decision-making. For example, our method has already proven successful in identifying a 600 bp deletion that affects commonly used RT-PCR–based clinical diagnostic assays [27,28]. Furthermore, our approach can be used to detect a mutation in the VP37 gene resulting in resistance to Tecovirimat, an antiviral medication widely used in the treatment of mpox, further highlighting the value of regular genomic surveillance to detect clinically important mutations [29,30]. There were several limitations in this study. First, the large number of primers included in the scheme resulted in differences in PCR efficiency between amplicons. By down-sampling the sequencing data, we show that a higher number of sequencing reads can overcome these challenges. Further optimization by designing primers targeting other positions and changing primer concentrations may help to reduce the number of raw sequencing reads needed to reach at least 10× coverage depth across the genome. Second, although results between laboratories were consistent, we observed some variability in the relation between Ct value and genome coverage. Differences in the sample types, qPCR assays, sequencing workflows, and thermocycler calibration can likely explain this variability. Third, there were some challenges with the more variable ends of the genome that contain inverted terminal repeats. This resulted in multiple binding sites for primers spanning these regions. In addition, this can create challenges when mapping reads to the inverted terminal repeats for both Illumina and Oxford Nanopore Technologies data, which may result in the misalignment of reads. This warrants careful interpretation of sequencing results in these genome regions. Lastly, orthopoxviruses are known to have genomic rearrangements (translocations, duplications, and inversions) especially in the inverted terminal repeats [31], which may not be well identified by amplicon-based sequencing. Although we have shown the efficacy of this approach in identifying mutations that affect diagnostic assays [28], amplicon-based sequencing may not be able to identify other genomic rearrangements that may have epidemiological or clinical significance. We recommend periodic long read metagenomic sequencing to supplement large-scale amplicon-based sequencing as an additional strategy to improve genomic surveillance of human monkeypox virus. Through this study, we have shown that amplicon-based sequencing can increase the sensitivity, breadth, and depth of human monkeypox virus genome coverage with low DNA concentration specimens. By being able to “plug” the human monkeypox virus primer scheme into existing sequencing and bioinformatics infrastructure, our approach has helped public health laboratories worldwide to quickly adapt their existing workflows in response to the global mpox outbreak.

Methods Ethics statement As part of this study, we sequenced remnant clinical specimens that tested presumptive positive for monkeypox virus. Ethical oversight for each institution is indicated in Table 1. All data were de-identified prior to sharing and sample codes as included in the manuscript are not known outside the research groups. PPT PowerPoint slide

PNG larger image

TIFF original image Download: Table 1. Ethical oversight. https://doi.org/10.1371/journal.pbio.3002151.t001 Primer scheme design The human monkeypox primer scheme (v1) was designed with PrimalScheme [15] using a pre-outbreak clade IIb reference genome (GenBank accession: MT903345) belonging to the A.1 lineage, following the newly proposed monkeypox virus naming system [8]. The primer scheme comprises a total of 163 primer pairs with an amplicon length ranging between 1,597 and 2,497 bp (average length of 1,977 bp; S1 Table). Clinical specimens for validation Validation of the primer scheme was done by MASPHL, CDPH, and YSPH. At CDPH, a total of 22 clinical specimens consisting of swabs from lesions of 12 individuals were tested. DNA was extracted from clinical specimens via the Roche MagNA pure 96 kit or manual extraction and tested with the non-variola Orthopox real-time PCR assay on the Bio-Rad CFX96 instrument [32]. At MASPHL, a total of 133 clinical specimens consisting of both lesion swabs and oropharyngeal swabs with and without detection of lesions in the throat were tested. DNA was extracted from clinical specimens using the QIAamp DSP DNA Blood Mini kit and tested with the non-variola Orthopox real-time PCR assay on the ABI 7500 Fast Real Time PCR instrument [32]. Metagenomic sequencing Initial validation was done by sequencing 10 clinical specimens with both metagenomic and amplicon-based sequencing approaches at MASPHL. For metagenomic sequencing, samples were first quantified using the Qubit 1x dsDNA High Sensitivity kit to determine concentration. Initial loading volume was calculated for each sample to fall in the recommended range of 100 to 500 ng. Each sample was then run in duplicate through the Illumina DNA Prep kit for library preparation following manufacturer’s protocol. After Flex Amplification PCR, the libraries were cleaned using the protocol option for standard DNA input. Post-library purification, each sample library was run on the Tapestation D1000 to determine the average peak size. Samples were also again quantified using the Qubit dsDNA High Sensitivity kit to best normalize the samples when pooling the libraries. Samples were then pooled, denatured, and diluted to 10 pM before being spiked with 5% PhiX. The diluted pooled libraries were then loaded and run on an Illumina v.2 300 cycle MiSeq cartridge, with a target of 1.5 to 3 million reads per library. Genomes were generated using the Broad Institute’s viral-pipelines workflows on Terra.bio using both the assemble_refbased and assemble_denovo workflows. The assemble_refbased workflow aligned reads against the MA001 (ON563414.3) genome for consensus generation. The assemble_denovo workflow scaffolded de novo SPAdes contigs against both the MA001 (ON563414.3) and RefSeq (NC_063383.1) references, followed by read-based polishing. Amplicon-based sequencing At MASPHL, libraries were prepared for sequencing using the Illumina DNA prep kit [20]. Initial library clean-up in the Illumina DNA prep protocol was done by following recommendations for standard DNA input, but later optimization showed improved coverage when following the recommendations for small PCR amplicon input. A negative template control was included during library prep for each sequencing run. Pooled libraries were sequenced on the Illumina MiSeq (paired-end 150), with a target of 0.5 to 1 million reads per library. For the initial 10 sequenced samples, primers were trimmed and consensus genomes were generated at a minimum depth of coverage of 10× via the TheiaCoV_Illumina_PE Workflow Series on Terra.bio. TheiaCoV_Illumina_PE was originally written to enable genomic characterization of SARS-CoV-2 specimens from Illumina paired-end amplicon read data. Modifications to TheiaCoV_Illumina_PE were made to support monkeypox virus genomic characterization; these modifications accommodated the use of a monkeypox virus reference sequence and primer scheme for consensus genome assembly. These updates were made available in the TheiaCov v2.2.0 release [33]. The Terra platform allows for consistently deployed bioinformatics environments without the need for on-site computing infrastructure and high-level programming capabilities. This allows for consistent version control, assembly parameters, and upload to public repositories across a distributed sequencing data generation network. At YSPH, libraries were prepared for sequencing using the Illumina COVIDSeq test (RUO version) [20]. A negative template control was included during library prep for each sequencing run. Pooled libraries were sequenced on the Illumina NovaSeq (paired-end 150), with on average 12 million reads per library (range: approximately 0.4 to approximately 20 million reads per library). Data analysis Bioinformatic analyses were done by YSPH to unify the analysis for data generated on Illumina sequencers. BAM files containing mapped reads were shared, and mapped reads were extracted using bamToFastq or “BEDtools bamtofastq” (version 2.30.0) [34] into FASTQ files before downstream analysis. To start the analysis, we remapped the reads to the human monkeypox reference genome (GenBank accession: MT903345) using BWA-MEM (version 0.7.17-r1188) [35]. The generated BAM mapping files were sorted using SAMtools (version 1.6) [36] and then used as input to iVar (version 1.3.1) [37] to trim primer sequences from reads. The trimmed BAM files were then used to generate consensus sequences using iVar with a minimum read depth of 10. We also calculated the per-base read coverage depth using genomeCoverageBed or “BEDTools genomecov” (version 2.30.0) [34]. To calculate the percent genome coverage for each sample, we generated a pairwise whole-genome sequence alignment of each sample against the human monkeypox virus reference genome (GenBank accession: MT903345) using Nextalign (version 1.4.1) [38]. We then calculated the percentage of alignment positions, excluding ambiguous nucleotides and deletions, using BioPython (version 1.7.9) [39]. To investigate the effect of the number of sequenced reads on the percent genome coverage, we generated randomly down-sampled sequence reads for the CDPH/YSPH samples. We used the CDPH/YSPH samples because they were sequenced at sufficiently high depth to allow down-sampling at different total read counts, namely 0.5, 1, 1.5, and 2 million reads per sample. We first generated interleaved sequencing read files from the paired-end sequencing reads using seqfu (version 1.14.0) [40] and then randomly down-sampled the reads at the specified total read count thresholds using “seqtk sample” (version 1.3-r106) [41]. Similarly, we generated the consensus whole-genome sequences and calculated the percentage genome coverage as described in the previous paragraph. All further data analysis and plotting were performed using R statistical software v4.2.0 [42] using the ggplot2 v3.3.6 [43], dplyr v1.0.9 [44], tidyr v1.2.0 [45], and cowplot v1.1.1 [46] packages. We fitted a logistic function specified as follows: y = a / (1 + exp(-b * (x—c))), where a, b, and c are parameters and “x” is the PCR Ct value and “y” is the percentage genome coverage or completeness. We used the “curve_fit” function in the numpy Python package to fit the model [47]. To interpolate the Ct value corresponding to an 80% threshold Ct value, we rearranged the logistic equation to estimate “x” given the estimated parameters a, b, and c, and genome coverage or “y” of 80% at each read coverage depth. Fig 5 was created in R using the leaflet package [48]. The base layer of the map is sourced from OpenStreetMap (https://github.com/CartoDB/basemap-styles/blob/master/LICENSE.md) and Carto (https://carto.com/basemaps/) under a CC-BY creative commons license. Public health response After initial validation, we made a detailed protocol publicly available and shared pooled primer aliquots with laboratories across the United States and internationally to support their public health genomic efforts [20]. Each laboratory sequenced samples by adapting their SARS-CoV-2 amplicon sequencing workflows, performed their own bioinformatics, and submitted sequencing data and consensus genomes to public repositories such as NCBI or GISAID (S3 Table). By sharing de-identified sequencing data (e.g., coded human-depleted raw reads or BAM files containing mapped reads) and metadata (e.g., sample codes, sample types, and Ct values), we ran the same bioinformatics pipeline on all data generated on Illumina platforms to determine breadth and depth of coverage for each genome under standardized conditions, as described above. After initial dissemination of primer aliquots, Integrated DNA Technologies created pre-pooled primer aliquots, which eliminates the need to manually pool individually ordered primers. These pools were validated by YSPH and revealed similar coverage as compared to initial results with manually pooled primers (S1 Fig). Centro Estadual de Vigilância em Saúde (CEVS) A total of 19 clinical specimens consisting of lesion swabs and the crusts of healing lesions were tested. DNA was extracted from clinical specimens using the Invitrogen PureLink Viral RNA/DNA Mini kit and tested with a clade-specific PCR assay on the Bio-Rad CFX opus 96 instrument. Libraries were prepared for sequencing using the Illumina DNA prep kit. Pooled libraries were sequenced on the Illumina MiSeq v3 (paired-end 150), with 2 million reads per library. Delaware Public Health Lab (DPHL) A total of 10 clinical specimens consisting of dry swabs from lesion sites were tested. DNA was manually extracted from clinical specimens using the QIAGEN QIAamp DSP DNA Blood Mini Kit. Amplification was achieved by using the Perfecta Multiplex qPCR SuperMix Low Rox PCR assay in conjunction with CDC issued Non-variola Orthopoxvirus Real-Time PCR Primer and Probe Set on the Applied Biosystems 7500 Fast Real-Time PCR instrument. Libraries were prepared for sequencing using the Illumina DNA prep kit. Pooled libraries were sequenced on the Illumina Miseq (paired-end 150), with about 1 million to 2.5 million reads per library. Florida Department of Health (FDH) A total of 6 clinical lesion swab specimens were tested. DNA was extracted from clinical specimens using the Qiagen QIAamp DSP DNA Blood Mini Kit and tested with the non-variola Orthopox real-time PCR assay on the BioRad T100 instrument [32]. Libraries were prepared for sequencing using the Illumina Nextera v2 kit. Pooled libraries were sequenced on the Illumina iSeq 100 v2 (paired-end 150), with 1 to 2.4 million reads per library. Idaho Bureau of Laboratories (IBL) A total of 9 lesion swab clinical specimens were tested. DNA was extracted from clinical specimens using the QIAGEN QIAamp DSP DNA Blood Mini kit and tested with Perfecta Multiplex qPCR SuperMix Low Rox PCR assay in conjunction with the CDC FDA-approved Non-variola Orthopoxvirus (VAC1) assay on the Applied Biosystems 7500 Fast Dx Real-Time PCR instrument. Libraries were prepared for sequencing using the Illumina DNA prep kit. Pooled libraries were sequenced on the Illumina MiSeq, with 0.8 to 1.2 million reads per library. Johns Hopkins Medical Institutions (JHMI) A total of 8 clinical lesion swab specimens were tested. DNA was extracted from clinical specimens using the bioMérieux easyMag and tested with a LDT PCR assay that adopted the primer and probe sequences of the non-variola orthopoxvirus, modified from Li and colleagues [49]. Total reaction volume for the real-time PCR was 20 μL (5 μL of template and 15 μL master mix). The master mix contained 5 μL TaqPath 1-Step RT-qPCR Master Mix (Applied Biosystems, A15299, Waltham, Massachusetts), 4 μL water, and 1 μL of each primer (10 nm) and the probe (5 nm) in addition to 1 μL of each primer (10 nm) and the probe (5 nm) for the RNAse P internal control target. Real-time PCR was performed using Prism 7500 Detection System (Applied Biosystems) and the following cycling conditions: 1 cycle at 95.0°C for 2 min and 40 cycles at 95.0°C for 3 s and 60.0°C for 31 s. Libraries were prepared for sequencing using NEBNext ARTIC reagents for SARS-CoV-2 sequencing. Pooled libraries were sequenced on the Oxford Nanopore Technologies GridIon. Primers were trimmed and consensus genomes were generated at a minimum depth of coverage of 10× using the ARTIC bioinformatics pipeline [50]. Los Angeles County Public Health Lab (LACPHL) A total of 27 remnant lesion swab specimens were tested. DNA was extracted using the Qiagen EZ1&2 DNA Tissue Kit from specimens that were previously tested with the non-variola Orthopoxvirus real-time PCR assay on the ABI 7500 FastDx instrument following Centers for Disease Control and Prevention Laboratory Response Network protocols [32]. Libraries were prepared for sequencing using the Illumina DNA prep kit. Pooled libraries were sequenced on the Illumina MiSeq v2 (paired-end 150), with 0.5 to 1 million reads per library. Minnesota Department of Health (MDH) A total of 25 clinical specimens consisting of lesion swabs from various anatomical sites were tested. DNA was extracted from clinical specimens using the QIAamp DSP DNA Blood Mini kit and tested with a non-variola Orthopox real-time PCR assay on the ABI 7500 Fast Real Time PCR instrument [32]. Libraries were prepared for sequencing using the Illumina DNA prep kit. Pooled libraries were sequenced on the Illumina MiSeq v2 (paired-end 250), with target of 500,000 reads per library. National Institute of Health Dr. Ricardo Jorge (INSA) A total of 78 clinical specimens consisting of lesion swabs from various anatomical sites and oropharyngeal swabs were tested. DNA was extracted from clinical specimens using the MagMAX Viral/Pathogen Nucleic Acid Isolation kit and tested with a real-time PCR assay on the CFX Opus real-time PCR system [51–53]. Libraries were prepared for sequencing using the Illumina Nextera XT library prep kit. Pooled libraries were sequenced on the Illumina NextSeq 550, with 2 million reads per library. National Health Service Lothian (NHS Lothian) A total of 34 clinical specimens consisting of vesicle swabs and swabs from various anatomical sites were tested. DNA was extracted from clinical specimens using the Biomerieux Nuclisens EasyMag kit and tested with the clade-specific real-time PCR assay on the Applied Biosystems 7500 Fast Real-Time PCR instrument [54]. Illumina libraries were prepared for sequencing using the Illumina COVIDSeq test (RUO version). Pooled libraries were sequenced on the Illumina MiSeq—Micro v2 reagent kit, with 400,000 reads per library. Primers were trimmed and consensus genomes were generated at a minimum depth of coverage of 5× using the Public Health Wales Nextflow nCoV-2019 pipeline that utilizes iVar [55]. Whole-genome PCR amplicons were also used to prepare Nanopore libraries using the Artic LoCost method [56], substituting Blunt TA Ligase with NEBNext Ultra II Ligation Mastermix for barcode ligation. Libraries were pooled on a single R9.4.1 flowcell and sequenced with a GridION (Oxford Nanopore Technologies) running live High Accuracy basecalling in MinKnow v21.11.6, aiming for 100,000 reads per library. Consensus genomes were generated at a minimum depth of coverage of 20× with the Artic field bioinformatics pipeline v1.2.1 and variants called with Nanopolish [55]. Rhode Island Department of Health/Rhode Island State Health Laboratory (RIDOH RISHL) A total of 56 clinical specimens consisting of dry vesicle swabs from various anatomical sites were tested. DNA was extracted from clinical specimens using the Qiagen QIAmp DSP Blood mini kit and tested with the non-variola Orthopox real-time PCR assay on the Applied biosystems 7500 instrument. Libraries were prepared for sequencing using the Illumina DNA prep kit. Pooled libraries were sequenced on the Illumina MiSeq (paired-end 150), with 1.2 million reads per library.

Acknowledgments We thank Cornelius Roemer for help with the logistic function analysis.

[END]
---
[1] Url: https://journals.plos.org/plosbiology/article?id=10.1371/journal.pbio.3002151

Published and (C) by PLOS One
Content appears here under this condition or license: Creative Commons - Attribution BY 4.0.

via Magical.Fish Gopher News Feeds:
gopher://magical.fish/1/feeds/news/plosone/