Network Working Group                                          E. Mannie
Request for Comments: 4606                                      Perceval
Obsoletes: 3946                                         D. Papadimitriou
Category: Standards Track                                        Alcatel
                                                            August 2006


  Generalized Multi-Protocol Label Switching (GMPLS) Extensions for
               Synchronous Optical Network (SONET) and
             Synchronous Digital Hierarchy (SDH) Control

Status of This Memo

  This document specifies an Internet standards track protocol for the
  Internet community, and requests discussion and suggestions for
  improvements.  Please refer to the current edition of the "Internet
  Official Protocol Standards" (STD 1) for the standardization state
  and status of this protocol.  Distribution cof this memo is
  unlimited.

Copyright Notice

  Copyright (C) The Internet Society (2006).

Abstract

  This document provides minor clarification to RFC 3946.

  This document is a companion to the Generalized Multi-protocol Label
  Switching (GMPLS) signaling.  It defines the Synchronous Optical
  Network (SONET)/Synchronous Digital Hierarchy (SDH) technology-
  specific information needed when GMPLS signaling is used.

Table of Contents

  1. Introduction ....................................................2
  2. SONET and SDH Traffic Parameters ................................3
     2.1. SONET/SDH Traffic Parameters ...............................3
     2.2. RSVP-TE Details ............................................9
     2.3. CR-LDP Details ............................................10
  3. SONET and SDH Labels ...........................................11
  4. Acknowledgements ...............................................16
  5. Security Considerations ........................................16
  6. IANA Considerations ............................................16
  Contributors ......................................................17
  Appendix 1. Signal Type Values Extension for VC-3 .................20
  Annex 1. Examples .................................................20
  Normative References ..............................................23



Mannie & Papadimitriou      Standards Track                     [Page 1]

RFC 4606        GMPLS Extensions for SONET & SDH Control     August 2006


1.  Introduction

  As described in [RFC3945], Generalized MPLS (GMPLS) extends MPLS from
  supporting packet (Packet Switching Capable, or PSC) interfaces and
  switching to include support of four new classes of interfaces and
  switching: Layer-2 Switch Capable (L2SC), Time-Division Multiplex
  (TDM), Lambda Switch Capable (LSC) and Fiber-Switch Capable (FSC).  A
  functional description of the extensions to MPLS signaling needed to
  support the new classes of interfaces and switching is provided in
  [RFC3471].  [RFC3473] describes RSVP-TE-specific formats and
  mechanisms needed to support all five classes of interfaces, and CR-
  LDP extensions can be found in [RFC3472].

  This document presents details that are specific to Synchronous
  Optical Network (SONET)/Synchronous Digital Hierarchy (SDH).  Per
  [RFC3471], SONET/SDH-specific parameters are carried in the signaling
  protocol in traffic parameter specific objects.

  The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
  "SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this
  document are to be interpreted as described in [RFC2119].

  Moreover, the reader is assumed to be familiar with the terminology
  in American National Standards Institute (ANSI) [T1.105] and ITU-T
  [G.707], as well as with that in [RFC3471], [RFC3472], and [RFC3473].
  The following abbreviations are used in this document:

  DCC: Data Communications Channel.
  LOVC: Lower-Order Virtual Container
  HOVC: Higher-Order Virtual Container
  MS: Multiplex Section.
  MSOH: Multiplex Section overhead.
  POH: Path overhead.
  RS: Regenerator Section.
  RSOH: Regenerator Section overhead.
  SDH: Synchronous digital hierarchy.
  SOH: Section overhead.
  SONET: Synchronous Optical Network.
  SPE: Synchronous Payload Envelope.
  STM(-N): Synchronous Transport Module (-N) (SDH).
  STS(-N): Synchronous Transport Signal-Level N (SONET).
  VC-n: Virtual Container-n (SDH).
  VTn: Virtual Tributary-n (SONET).








Mannie & Papadimitriou      Standards Track                     [Page 2]

RFC 4606        GMPLS Extensions for SONET & SDH Control     August 2006


2.  SONET and SDH Traffic Parameters

  This section defines the GMPLS traffic parameters for SONET/SDH.  The
  protocol-specific formats, for the SONET/SDH-specific RSVP-TE objects
  and CR-LDP TLVs, are described in Sections 2.2 and 2.3, respectively.

  These traffic parameters specify a base set of capabilities for SONET
  ANSI [T1.105] and SDH ITU-T [G.707], such as concatenation and
  transparency.  Other documents may further enhance this set of
  capabilities in the future.  For instance, signaling for SDH over PDH
  ITU-T G.832 or sub-STM-0 ITU-T G.708 interfaces could be defined.

  The traffic parameters defined hereafter (see Section 2.1) MUST be
  used when the label is encoded as SUKLM as defined in this memo (see
  Section 3).  They MUST also be used when requesting one of Section/RS
  or Line/MS overhead transparent STS-1/STM-0, STS-3*N/STM-N (N=1, 4,
  16, 64, 256) signals.

  The traffic parameters and label encoding defined in [RFC3471],
  Section 3.2, MUST be used for fully transparent STS-1/STM-0,
  STS-3*N/STM-N (N=1, 4, 16, 64, 256) signal requests.  A fully
  transparent signal is one for which all overhead is left unmodified
  by intermediate nodes; i.e., when all defined Transparency (T) bits
  would be set if the traffic parameters defined in Section 2.1 were
  used.

2.1.  SONET/SDH Traffic Parameters

  The traffic parameters for SONET/SDH are organized as follows:

   0                   1                   2                   3
   0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
  +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
  |  Signal Type  |      RCC      |              NCC              |
  +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
  |              NVC              |        Multiplier (MT)        |
  +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
  |                       Transparency (T)                        |
  +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
  |                           Profile (P)                         |
  +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

  Annex 1 lists examples of SONET and SDH signal coding.








Mannie & Papadimitriou      Standards Track                     [Page 3]

RFC 4606        GMPLS Extensions for SONET & SDH Control     August 2006


  o) Signal Type (ST): 8 bits

  This field indicates the type of Elementary Signal that constitutes
  the requested Label Switched Path (LSP).  Several transforms can be
  applied successively on the Elementary Signal to build the Final
  Signal actually being requested for the LSP.

  Each transform application is optional and must be ignored if zero,
  except the Multiplier (MT), which cannot be zero and is ignored if
  equal to one.

  Transforms must be applied strictly in the following order:

  - First, contiguous concatenation (by using the RCC and NCC fields)
    can be optionally applied on the Elementary Signal, resulting in a
    contiguously concatenated signal.

  - Second, virtual concatenation (by using the NVC field) can be
    optionally applied on the Elementary Signal, resulting in a
    virtually concatenated signal.

  - Third, some transparency (by using the Transparency field) can be
    optionally specified when a frame is requested as signal rather
    than an SPE- or VC-based signal.

  - Fourth, a multiplication (by using the Multiplier field) can be
    optionally applied directly on the Elementary Signal, on the
    contiguously concatenated signal obtained from the first phase, on
    the virtually concatenated signal obtained from the second phase,
    or on these signals combined with some transparency.

  Permitted Signal Type values for SONET/SDH are

  Value  Type (Elementary Signal)
  -----  ------------------------
    1     VT1.5  SPE / VC-11
    2     VT2    SPE / VC-12
    3     VT3    SPE
    4     VT6    SPE / VC-2
    5     STS-1  SPE / VC-3
    6     STS-3c SPE / VC-4
    7     STS-1      / STM-0   (only when transparency is requested)
    8     STS-3      / STM-1   (only when transparency is requested)
    9     STS-12     / STM-4   (only when transparency is requested)
    10    STS-48     / STM-16  (only when transparency is requested)
    11    STS-192    / STM-64  (only when transparency is requested)
    12    STS-768    / STM-256 (only when transparency is requested)




Mannie & Papadimitriou      Standards Track                     [Page 4]

RFC 4606        GMPLS Extensions for SONET & SDH Control     August 2006


  A dedicated signal type is assigned to a SONET STS-3c SPE instead of
  being coded as a contiguous concatenation of three STS-1 SPEs.  This
  is done in order to provide easy interworking between SONET and SDH
  signaling.

  Appendix 1 adds one signal type (optional) to the above values.

  o) Requested Contiguous Concatenation (RCC): 8 bits

  This field is used to request the optional SONET/SDH contiguous
  concatenation of the Elementary Signal.

  This field is a vector of flags.  Each flag indicates the support of
  a particular type of contiguous concatenation.  Several flags can be
  set at the same time to indicate a choice.

  These flags allow an upstream node to indicate to a downstream node
  the different types of contiguous concatenation that it supports.
  However, the downstream node decides which one to use according to
  its own rules.

  A downstream node receiving simultaneously more than one flag chooses
  a particular type of contiguous concatenation, if any is supported,
  and according to criteria that are out of this document's scope.  A
  downstream node that doesn't support any of the concatenation types
  indicated by the field must refuse the LSP request.  In particular,
  it must refuse the LSP request if it doesn't support contiguous
  concatenation at all.

  When several flags have been set, the upstream node retrieves the
  (single) type of contiguous concatenation the downstream node has
  selected by looking at the position indicated by the first label and
  the number of labels as returned by the downstream node (see also
  Section 3).

  The entire field is set to zero to indicate that no contiguous
  concatenation is requested at all (default value).  A non-zero field
  indicates that some contiguous concatenation is requested.

  The following flag is defined:

     Flag 1 (bit 1): Standard contiguous concatenation.

  Flag 1 indicates that the standard SONET/SDH contiguous
  concatenation, as defined in [T1.105]/[G.707], is supported.  Note
  that bit 1 is the low-order bit.  Other flags are reserved for
  extensions; if not used, they must be set to zero when sent and
  should be ignored when received.



Mannie & Papadimitriou      Standards Track                     [Page 5]

RFC 4606        GMPLS Extensions for SONET & SDH Control     August 2006


  See note 1 in the section on the NCC about the SONET contiguous
  concatenation of STS-1 SPEs when the number of components is a
  multiple of three.

  o) Number of Contiguous Components (NCC): 16 bits

  This field indicates the number of identical SONET SPEs/SDH VCs
  (i.e., Elementary Signal) that are requested to be concatenated, as
  specified in the RCC field.

  Note 1: When a SONET STS-Nc SPE with N=3*X is requested, the
  Elementary Signal to be used must always be an STS-3c_SPE signal
  type, and the value of NCC must always be equal to X.  This allows
  facilitating the interworking between SONET and SDH.  In particular,
  it means that the contiguous concatenation of three STS-1 SPEs cannot
  be requested, as according to this specification this type of signal
  must be coded using the STS-3c SPE signal type.

  Note 2: When a transparent STS-N/STM-N signal is requested that is
  limited to a single contiguously concatenated STS-Nc_SPE/VC-4-Nc, the
  signal type must be STS-N/STM-N, RCC with flag 1, NCC set to 1.

  The NCC value must be consistent with the type of contiguous
  concatenation being requested in the RCC field.  In particular, this
  field is irrelevant if no contiguous concatenation is requested (RCC
  = 0).  In that case, it must be set to zero when sent and should be
  ignored when received.  A RCC value different from 0 implies a number
  of contiguous components greater than or equal to 1.

  Note 3: Following these rules, when a VC-4 signal is requested, the
  RCC and the NCC values SHOULD be set to 0, whereas for an STS-3c SPE
  signal, the RCC and the NCC values SHOULD be set 1.  However, if
  local conditions allow, since the setting of the RCC and NCC values
  is locally driven, the requesting upstream node MAY set the RCC and
  NCC values to either SDH or SONET settings without impacting the
  function.  Moreover, the downstream node SHOULD accept the requested
  values if local conditions allow.  If these values cannot be
  supported, the receiver downstream node SHOULD generate a
  PathErr/NOTIFICATION message (see Sections 2.2 and 2.3,
  respectively).

  o) Number of Virtual Components (NVC): 16 bits

  This field indicates the number of signals that are requested to be
  virtually concatenated.  These signals are all of the same type by
  definition.  They are Elementary Signal SPEs/VCs for which signal
  types are defined in this document; i.e., VT1.5_SPE/VC-11,




Mannie & Papadimitriou      Standards Track                     [Page 6]

RFC 4606        GMPLS Extensions for SONET & SDH Control     August 2006


  VT2_SPE/VC-12, VT3_SPE, VT6_SPE/VC-2, STS-1_SPE/VC-3, or
  STS-3c_SPE/VC-4.

  This field is set to 0 (default value) to indicate that no virtual
  concatenation is requested.

  o) Multiplier (MT): 16 bits

  This field indicates the number of identical signals that are
  requested for the LSP; i.e., that form the Final Signal.  These
  signals can be identical Elementary Signals, identical contiguously
  concatenated signals, or identical virtually concatenated signals.
  Note that all of these signals thus belong to the same LSP.

  The distinction between the components of multiple virtually
  concatenated signals is done via the order of the labels that are
  specified in the signaling.  The first set of labels must describe
  the first component (set of individual signals belonging to the first
  virtual concatenated signal), the second set must describe the second
  component (set of individual signals belonging to the second virtual
  concatenated signal), and so on.

  This field is set to one (default value) to indicate that exactly one
  instance of a signal is being requested.  Intermediate and egress
  nodes MUST verify that the node itself and the interfaces on which
  the LSP will be established can support the requested multiplier
  value.  If the requested values cannot be supported, the receiver
  node MUST generate a PathErr/NOTIFICATION message (see Sections 2.2
  and 2.3, respectively).

  Zero is an invalid value.  If a zero is received, the node MUST
  generate a PathErr/NOTIFICATION message (see Sections 2.2 and 2.3,
  respectively).

  Note 1: When a transparent STS-N/STM-N signal is requested that is
  limited to a single contiguously concatenated STS-Nc-SPE/VC-4-Nc, the
  multiplier field MUST be equal to 1 (only valid value).

  o) Transparency (T): 32 bits

  This field is a vector of flags that indicates the type of
  transparency being requested.  Several flags can be combined to
  provide different types of transparency.  Not all combinations are
  necessarily valid.  The default value for this field is zero, i.e.,
  no transparency is requested.






Mannie & Papadimitriou      Standards Track                     [Page 7]

RFC 4606        GMPLS Extensions for SONET & SDH Control     August 2006


  Transparency, as defined from the point of view of this signaling
  specification, is only applicable to the fields in the SONET/SDH
  frame overheads.  In the SONET case, these are the fields in the
  Section Overhead (SOH) and the Line Overhead (LOH).  In the SDH case,
  these are the fields in the Regenerator Section Overhead (RSOH), the
  Multiplex Section overhead (MSOH), and the pointer fields between the
  two.  With SONET, the pointer fields are part of the LOH.

  Note also that transparency is only applicable when the following
  signal types are used: STS-1/STM-0, STS-3/STM-1, STS-12/STM-4,
  STS-48/STM-16, STS-192/STM-64, and STS-768/STM-256.  At least one
  transparency type must be specified when such a signal type is
  requested.

  Transparency indicates precisely which fields in these overheads must
  be delivered unmodified at the other end of the LSP.  An ingress
  Label Switching Router (LSR) requesting transparency will pass these
  overhead fields that must be delivered to the egress LSR without any
  change.  From the ingress and egress LSRs point of views, these
  fields must be seen as being unmodified.

  Transparency is applied not at the interfaces with the initiating and
  terminating LSRs but only between intermediate LSRs.  The
  transparency field is used to request an LSP that supports the
  requested transparency type; it may also be used to set up the
  transparency process to be applied at each intermediate LSR.

  The different transparency flags are as follows:

     Flag 1 (bit 1): Section/Regenerator Section layer
     Flag 2 (bit 2): Line/Multiplex Section layer

  where bit 1 is the low-order bit.  Other flags are reserved; they
  should be set to zero when sent and ignored when received.  A flag is
  set to one to indicate that the corresponding transparency is
  requested.

  Intermediate and egress nodes MUST verify that the node itself and
  the interfaces on which the LSP will be established can support the
  requested transparency.  If the requested flags cannot be supported,
  the receiver node MUST generate a PathErr/NOTIFICATION message (see
  Sections 2.2 and 2.3, respectively).

  Section/Regenerator Section layer transparency means that the entire
  frames must be delivered unmodified.  This implies that pointers
  cannot be adjusted.  When Section/Regenerator Section layer
  transparency is used all other flags MUST be ignored.




Mannie & Papadimitriou      Standards Track                     [Page 8]

RFC 4606        GMPLS Extensions for SONET & SDH Control     August 2006


  Line/Multiplex Section layer transparency means that the LOH/MSOH
  must be delivered unmodified.  This implies that pointers cannot be
  adjusted.

  o) Profile (P): 32 bits

  This field is intended to indicate particular capabilities that must
  be supported for the LSP; for example, monitoring capabilities.

  No standard profile is currently defined, and this field SHOULD be
  set to zero when transmitted and ignored when received.

  In the future, TLV-based extensions may be created.

2.2. RSVP-TE Details

  For RSVP-TE, the SONET/SDH traffic parameters are carried in the
  SONET/SDH SENDER_TSPEC and FLOWSPEC objects.  The same format is used
  both for the SENDER_TSPEC object and for FLOWSPEC objects.  The
  content of the objects is defined above, in Section 2.1.  The objects
  have the following class and type for SONET ANSI T1.105 and SDH ITU-T
  G.707:

     SONET/SDH SENDER_TSPEC object: Class = 12, C-Type = 4
     SONET/SDH FLOWSPEC object: Class = 9, C-Type = 4

  There is no Adspec associated with the SONET/SDH SENDER_TSPEC.
  Either the Adspec is omitted, or an int-serv Adspec with the Default
  General Characterization Parameters and Guaranteed Service fragment
  is used; see [RFC2210].

  For a particular sender in a session, the contents of the FLOWSPEC
  object received in a Resv message SHOULD be identical to the contents
  of the SENDER_TSPEC object received in the corresponding Path
  message.  If the objects do not match, a ResvErr message with a
  "Traffic Control Error/Bad Flowspec value" error SHOULD be generated.

  Intermediate and egress nodes MUST verify that the node itself and
  the interfaces on which the LSP will be established can support the
  requested Signal Type, RCC, NCC, NVC and Multiplier (as defined in
  Section 2.1).  If the requested value(s) can not be supported, the
  receiver node MUST generate a PathErr message with a "Traffic Control
  Error/ Service unsupported" indication (see [RFC2205]).

  In addition, if the MT field is received with a zero value, the node
  MUST generate a PathErr message with a "Traffic Control Error/Bad
  Tspec value" indication (see [RFC2205]).




Mannie & Papadimitriou      Standards Track                     [Page 9]

RFC 4606        GMPLS Extensions for SONET & SDH Control     August 2006


  Intermediate nodes MUST also verify that the node itself and the
  interfaces on which the LSP will be established can support the
  requested Transparency (as defined in Section 2.1).  If the requested
  value(s) cannot be supported, the receiver node MUST generate a
  PathErr message with a "Traffic Control Error/Service unsupported"
  indication (see [RFC2205]).

2.3.  CR-LDP Details

  For CR-LDP, the SONET/SDH traffic parameters are carried in the
  SONET/SDH Traffic Parameters TLV.  The content of the TLV is defined
  above, in Section 2.1.  The header of the TLV has the following
  format:

   0                   1                   2                   3
   0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
  +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
  |U|F|          Type             |      Length                   |
  +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

  The type field for the SONET/SDH Traffic Parameters TLV is 0x0838.

  Intermediate and egress nodes MUST verify that the node itself and
  the interfaces on which the LSP will be established can support the
  requested Signal Type, RCC, NCC, NVC, and Multiplier (as defined in
  Section 2.1).  If the requested value(s) cannot be supported, the
  receiver node MUST generate a NOTIFICATION message with a "Resource
  Unavailable" status code (see [RFC3212]).

  In addition, if the MT field is received with a zero value, the node
  MUST generate a NOTIFICATION message with a "Resource Unavailable"
  status code (see [RFC3212]).

  Intermediate nodes MUST also verify that the node itself and the
  interfaces on which the LSP will be established can support the
  requested Transparency (as defined in Section 2.1).  If the requested
  value(s) cannot be supported, the receiver node MUST generate a
  NOTIFICATION message with a "Resource Unavailable" status code (see
  [RFC3212]).












Mannie & Papadimitriou      Standards Track                    [Page 10]

RFC 4606        GMPLS Extensions for SONET & SDH Control     August 2006


3.  SONET and SDH Labels

  SONET and SDH each define a multiplexing structure.  Both structures
  are trees whose roots are, respectively, an STS-N or an STM-N and
  whose leaves are the signals that can be transported via the time-
  slots and switched between time-slots within an ingress port and
  time-slots within an egress port; i.e., a VTx SPE, an STS-x SPE, or a
  VC-x.  A SONET/SDH label will identify the exact position (i.e.,
  first time-slot) of a particular VTx SPE, STS-x SPE, or VC-x signal
  in a multiplexing structure.  SONET and SDH labels are carried in the
  Generalized Label per [RFC3473] and [RFC3472].

  Note that by time-slots we mean the time-slots as they appear
  logically and sequentially in the multiplex, not as they appear after
  any possible interleaving.

  These multiplexing structures will be used as naming trees to create
  unique multiplex entry names or labels.  The same format of label is
  used for SONET and SDH.  As explained in [RFC3471], a label does not
  identify the "class" to which the label belongs.  This is implicitly
  determined by the link on which the label is used.

  In case of signal concatenation or multiplication, a list of labels
  can appear in the Label field of a Generalized Label.

  In case of contiguous concatenation, only one label appears in the
  Label field.  This unique label is encoded as a single 32-bit label
  value (as defined in this section) of the Generalized Label object
  (Class-Num = 16, C-Type = 2)/TLV (0x0825).  This label identifies the
  lowest time-slot occupied by the contiguously concatenated signal.
  By lowest time-slot, we mean the one having the lowest label (value)
  when compared as an integer value; i.e., the time-slot occupied by
  the first component signal of the concatenated signal encountered
  descending the tree.

  In case of virtual concatenation, the explicit ordered list of all
  labels in the concatenation is given.  This ordered list of labels is
  encoded as a sequence of 32-bit label values (as defined in this
  section) of the Generalized Label object (Class-Num = 16, C-Type =
  2)/TLV (0x0825).  Each label indicates the first time-slot occupied
  by a component of the virtually concatenated signal.  The order of
  the labels must reflect the order of the payloads to concatenate (not
  the physical order of time-slots).  The above representation limits
  virtual concatenation to remain within a single (component) link; it
  imposes, as such, a restriction compared to the ANSI [T1.105]/ ITU-T
  [G.707] recommendations.  The standard definition for virtual
  concatenation allows each virtual concatenation components to travel
  over diverse paths.  Within GMPLS, virtual concatenation components



Mannie & Papadimitriou      Standards Track                    [Page 11]

RFC 4606        GMPLS Extensions for SONET & SDH Control     August 2006


  must travel over the same (component) link if they are part of the
  same LSP.  This is due to the way that labels are bound to a
  (component) link.  Note, however, that the routing of components on
  different paths is indeed equivalent to establishing different LSPs,
  each one having its own route.  Several LSPs can be initiated and
  terminated between the same nodes, and their corresponding components
  can then be associated together (i.e., virtually concatenated).

  In case of multiplication (i.e., using the multiplier transform), the
  explicit ordered list of all labels that take part in the Final
  Signal is given.  This ordered list of labels is encoded as a
  sequence of 32-bit label values (as defined in this section) of the
  Generalized Label object (Class-Num = 16, C-Type = 2)/TLV (0x0825).
  In case of multiplication of virtually concatenated signals, the
  explicit ordered list of the set of labels that take part in the
  Final Signal is given.  The first set of labels indicates the time-
  slots occupied by the first virtually concatenated signal, the second
  set of labels indicates the time-slots occupied by the second
  virtually concatenated signal, and so on.  The above representation
  limits multiplication to remain within a single (component) link.

  The format of the label for SONET and/or SDH TDM-LSR link is

   0                   1                   2                   3
   0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
  +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
  |               S               |   U   |   K   |   L   |   M   |
  +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

  This is an extension of the numbering scheme defined in [G.707],
  Sections 7.3.7 through 7.3.13; i.e., the (K, L, M) numbering.  Note
  that the higher order numbering scheme defined in [G.707], Sections
  7.3.1 through 7.3.6, is not used here.

  Each letter indicates a possible branch number starting at the parent
  node in the multiplex structure.  Branches are considered as being
  numbered in increasing order, starting from the top of the
  multiplexing structure.  The numbering starts at 1; zero is used to
  indicate a non-significant or ignored field.

  When a field is not significant or ignored in a particular context,
  it MUST be set to zero when transmitted and ignored when received.

  When a hierarchy of SONET/SDH LSPs is used, a higher-order LSP with a
  given bandwidth can be used to carry lower-order LSPs.  Remember that
  a higher-order LSP is established through a SONET/SDH higher-order
  path layer network, and a lower-order LSP through a SONET/SDH lower-
  order path layer network (see also ITU-T G.803, Section 3, for the



Mannie & Papadimitriou      Standards Track                    [Page 12]

RFC 4606        GMPLS Extensions for SONET & SDH Control     August 2006


  corresponding definitions).  In this context, the higher-order
  SONET/SDH LSP behaves as a "virtual link" with a given bandwidth
  (e.g., VC-3); it may also be used as a Forwarding Adjacency.  A
  lower-order SONET/SDH LSP can be established through that higher-
  order LSP.  Since a label is local to a (virtual) link, the highest
  part of that label (i.e., the S, U, and K fields) is non-significant
  and is set to zero; i.e., the label is "0,0,0,L,M".  Similarly, if
  the structure of the lower-order LSP is unknown or not relevant, the
  lowest part of that label (i.e., the L and M fields) is non-
  significant and is set to zero; i.e., the label is "S,U,K,0,0".

  For instance, a VC-3 LSP can be used to carry lower-order LSPs.  In
  that case, the labels allocated between the two ends of the VC-3 LSP
  for the lower-order LSPs will have S, U, and K set to zero (i.e.,
  non-significant) while L and M will be used to indicate the signal
  allocated in that VC-3.

  In case of tunneling, such as VC-4 containing VC-3 containing
  VC-12/VC-11, where the SUKLM structure is not adequate to represent
  the full signal structure, a hierarchical approach must be used;
  i.e., per layer network signaling.

  The possible values of S, U, K, L, and M are defined as follows:

  1.  S=1->N is the index of a particular STS-3/AUG-1 inside an
      STS-N/STM-N multiplex.  S is only significant for SONET STS-N
      (N>1) and SDH STM-N (N>0).  S must be 0 and ignored for STS-1 and
      STM-0.

  2.  U=1->3 is the index of a particular STS-1_SPE/VC-3 within an
      STS-3/AUG-1.  U is only significant for SONET STS-N (N>1) and SDH
      STM-N (N>0).  U must be 0 and ignored for STS-1 and STM-0.

  3.  K=1->3 is the index of a particular TUG-3 within a VC-4.  K is
      only significant for an SDH VC-4 structured in TUG-3s.  K must be
      0 and ignored in all other cases.

  4.  L=1->7 is the index of a particular VT_Group/TUG-2 within an
      STS-1_SPE/TUG-3 or VC-3.  L must be 0 and ignored in all other
      cases.

  5.  M is the index of a particular VT1.5_SPE/VC-11, VT2_SPE/VC-12, or
      VT3_SPE within a VT_Group/TUG-2.  M=1->2 indicates a specific VT3
      SPE inside the corresponding VT Group; these values MUST NOT be
      used for SDH, since there is no equivalent of VT3 with SDH.
      M=3->5 indicates a specific VT2_SPE/VC-12 inside the
      corresponding VT_Group/TUG-2.  M=6->9 indicates a specific
      VT1.5_SPE/VC-11 inside the corresponding VT_Group/TUG-2.



Mannie & Papadimitriou      Standards Track                    [Page 13]

RFC 4606        GMPLS Extensions for SONET & SDH Control     August 2006


  Note that a label always has to be interpreted according the
  SONET/SDH traffic parameters; i.e., a label by itself does not allow
  knowing which signal is being requested (a label is context
  sensitive).

  The label format defined in this section, referred to as SUKLM, MUST
  be used for any SONET/SDH signal requests that are not transparent;
  i.e., when all Transparency (T) bits defined in Section 2.1 are set
  to zero.  Any transparent STS-1/STM-0/STS-3*N/STM-N (N=1, 4, 16, 64,
  256) signal request MUST use a label format as defined in [RFC3471].

  The S encoding is summarized in the following table:

   S    SDH                     SONET
  ------------------------------------------------
   0    other                   other
   1    1st AUG-1               1st STS-3
   2    2nd AUG-1               2nd STS-3
   3    3rd AUG-1               3rd STS-3
   4    4rd AUG-1               4rd STS-3
   :    :                       :
   N    Nth AUG-1               Nth STS-3


  The U encoding is summarized in the following table:

   U    SDH AUG-1               SONET STS-3
  -------------------------------------------------
   0    other                   other
   1    1st VC-3                1st STS-1 SPE
   2    2nd VC-3                2nd STS-1 SPE
   3    3rd VC-3                3rd STS-1 SPE


  The K encoding is summarized in the following table:

   K    SDH VC-4
  ---------------
   0    other
   1    1st TUG-3
   2    2nd TUG-3
   3    3rd TUG-3









Mannie & Papadimitriou      Standards Track                    [Page 14]

RFC 4606        GMPLS Extensions for SONET & SDH Control     August 2006


  The L encoding is summarized in the following table:

   L    SDH TUG-3    SDH VC-3    SONET STS-1 SPE
  -------------------------------------------------
   0    other        other       other
   1    1st TUG-2    1st TUG-2   1st VTG
   2    2nd TUG-2    2nd TUG-2   2nd VTG
   3    3rd TUG-2    3rd TUG-2   3rd VTG
   4    4th TUG-2    4th TUG-2   4th VTG
   5    5th TUG-2    5th TUG-2   5th VTG
   6    6th TUG-2    6th TUG-2   6th VTG
   7    7th TUG-2    7th TUG-2   7th VTG


  The M encoding is summarized in the following table:

   M    SDH TUG-2                 SONET VTG
  -------------------------------------------------
   0    other                     other
   1    -                         1st VT3 SPE
   2    -                         2nd VT3 SPE
   3    1st VC-12                 1st VT2 SPE
   4    2nd VC-12                 2nd VT2 SPE
   5    3rd VC-12                 3rd VT2 SPE
   6    1st VC-11                 1st VT1.5 SPE
   7    2nd VC-11                 2nd VT1.5 SPE
   8    3rd VC-11                 3rd VT1.5 SPE
   9    4th VC-11                 4th VT1.5 SPE

  Examples of Labels

  Example 1: the label for the STS-3c_SPE/VC-4 in the Sth
             STS-3/AUG-1 is: S>0, U=0, K=0, L=0, M=0.

  Example 2: the label for the VC-3 within the Kth-1 TUG-3 within
             the VC-4 in the Sth AUG-1 is: S>0, U=0, K>0, L=0, M=0.

  Example 3: the label for the Uth-1 STS-1_SPE/VC-3 within the Sth
             STS-3/AUG-1 is: S>0, U>0, K=0, L=0, M=0.

  Example 4: the label for the VT6/VC-2 in the Lth-1 VT Group/TUG-2
             in the Uth-1 STS-1_SPE/VC-3 within the Sth STS-3/AUG-1
             is: S>0, U>0, K=0, L>0, M=0.

  Example 5: the label for the 3rd VT1.5_SPE/VC-11 in the Lth-1 VT
             Group/TUG-2 within the Uth-1 STS-1_SPE/VC-3 within the
             Sth STS-3/AUG-1 is: S>0, U>0, K=0, L>0, M=8.




Mannie & Papadimitriou      Standards Track                    [Page 15]

RFC 4606        GMPLS Extensions for SONET & SDH Control     August 2006


  Example 6: the label for the STS-12c SPE/VC-4-4c which uses the
             9th STS-3/AUG-1 as its first timeslot is: S=9, U=0,
             K=0, L=0, M=0.

  In case of contiguous concatenation, the label that is used is the
  lowest label (value) of the contiguously concatenated signal, as
  explained before.  The higher part of the label indicates where the
  signal starts, and the lowest part is not significant.

  In case of STM-0/STS-1, the values of S, U, and K must be equal to
  zero, according to the field coding rules.  For instance, when a VC-3
  in an STM-0 is requested, the label is S=0, U=0, K=0, L=0, M=0.  When
  a VC-11 in a VC-3 in an STM-0 is requested, the label is S=0, U=0,
  K=0, L>0, M=6..9.


  Note: when a Section/RS or Line/MS transparent STS-1/STM-0/
  STS-3*N/STM-N (N=1, 4, 16, 64, 256) signal is requested, the SUKLM
  label format and encoding is not applicable, and the label encoding
  MUST follow the rules defined in [RFC3471], Section 3.2.

4.  Acknowledgements

  Valuable comments and input were received from the CCAMP mailing
  list, where outstanding discussions took place.

  The authors would like to thank Richard Rabbat for his valuable
  input, which lead to this revision.

5.  Security Considerations

  This document introduces no new security considerations to either
  [RFC3473] or [RFC3472].  GMPLS security is described in Section 11 of
  [RFC3471] and refers to [RFC3209] for RSVP-TE and to [RFC3212] for
  CR-LDP.

6. IANA Considerations

  Three values defined by IANA for RFC 3946 now apply to this document.

  Two RSVP C-Types in registry:
     http://www.iana.org/assignments/rsvp-parameters

  -  A SONET/SDH SENDER_TSPEC object: Class = 12, C-Type = 4 (see
     Section 2.2).

  -  A SONET/SDH FLOWSPEC object: Class = 9, C-Type = 4 (see Section
     2.2).



Mannie & Papadimitriou      Standards Track                    [Page 16]

RFC 4606        GMPLS Extensions for SONET & SDH Control     August 2006


  One LDP TLV Type in registry:
     http://www.iana.org/assignments/ldp-namespaces

  -  A type field for the SONET/SDH Traffic Parameters TLV (see Section
     2.3).

Contributors

  Contributors are listed in alphabetical order:

  Stefan Ansorge (Alcatel)
  Lorenzstrasse 10
  70435 Stuttgart, Germany
  EMail: [email protected]

  Peter Ashwood-Smith (Nortel)
  PO. Box 3511 Station C,
  Ottawa, ON K1Y 4H7, Canada
  EMail:[email protected]

  Ayan Banerjee (Calient)
  5853 Rue Ferrari
  San Jose, CA 95138, USA
  EMail: [email protected]

  Lou Berger (Movaz)
  7926 Jones Branch Drive
  McLean, VA 22102, USA
  EMail: [email protected]

  Greg Bernstein (Ciena)
  10480 Ridgeview Court
  Cupertino, CA 94014, USA
  EMail: [email protected]

  Angela Chiu (Celion)
  One Sheila Drive, Suite 2
  Tinton Falls, NJ 07724-2658
  EMail: [email protected]

  John Drake (Calient)
  5853 Rue Ferrari
  San Jose, CA 95138, USA
  EMail: [email protected]







Mannie & Papadimitriou      Standards Track                    [Page 17]

RFC 4606        GMPLS Extensions for SONET & SDH Control     August 2006


  Yanhe Fan (Axiowave)
  100 Nickerson Road
  Marlborough, MA 01752, USA
  EMail: [email protected]

  Michele Fontana (Alcatel)
  Via Trento 30,
  I-20059 Vimercate, Italy
  EMail: [email protected]

  Gert Grammel (Alcatel)
  Lorenzstrasse, 10
  70435 Stuttgart, Germany
  EMail: [email protected]

  Juergen Heiles (Siemens)
  Hofmannstr. 51
  D-81379 Munich, Germany
  EMail: [email protected]

  Suresh Katukam (Cisco)
  1450 N. McDowell Blvd,
  Petaluma, CA 94954-6515, USA
  EMail: [email protected]

  Kireeti Kompella (Juniper)
  1194 N. Mathilda Ave.
  Sunnyvale, CA 94089, USA
  EMail: [email protected]

  Jonathan P. Lang (Calient)
  25 Castilian
  Goleta, CA 93117, USA
  EMail: [email protected]

  Fong Liaw (Solas Research)
  EMail: [email protected]

  Zhi-Wei Lin (Lucent)
  101 Crawfords Corner Rd
  Holmdel, NJ  07733-3030, USA
  EMail: [email protected]

  Ben Mack-Crane (Tellabs)
  EMail: [email protected]






Mannie & Papadimitriou      Standards Track                    [Page 18]

RFC 4606        GMPLS Extensions for SONET & SDH Control     August 2006


  Dimitrios Pendarakis (Tellium)
  2 Crescent Place, P.O. Box 901
  Oceanport, NJ 07757-0901, USA
  EMail: [email protected]

  Mike Raftelis (White Rock)
  18111 Preston Road
  Dallas, TX 75252, USA

  Bala Rajagopalan (Tellium)
  2 Crescent Place, P.O. Box 901
  Oceanport, NJ 07757-0901, USA
  EMail: [email protected]

  Yakov Rekhter (Juniper)
  1194 N. Mathilda Ave.
  Sunnyvale, CA 94089, USA
  EMail: [email protected]

  Debanjan Saha (Tellium)
  2 Crescent Place, P.O. Box 901
  Oceanport, NJ 07757-0901, USA
  EMail: [email protected]

  Vishal Sharma (Metanoia)
  335 Elan Village Lane
  San Jose, CA 95134, USA
  EMail: [email protected]

  George Swallow (Cisco)
  250 Apollo Drive
  Chelmsford, MA 01824, USA
  EMail: [email protected]

  Z. Bo Tang (Tellium)
  2 Crescent Place, P.O. Box 901
  Oceanport, NJ 07757-0901, USA
  EMail: [email protected]

  Eve Varma (Lucent)
  101 Crawfords Corner Rd
  Holmdel, NJ  07733-3030, USA
  EMail: [email protected]

  Yangguang Xu (Lucent)
  21-2A41, 1600 Osgood Street
  North Andover, MA 01845, USA
  EMail: [email protected]



Mannie & Papadimitriou      Standards Track                    [Page 19]

RFC 4606        GMPLS Extensions for SONET & SDH Control     August 2006


Appendix 1.  Signal Type Values Extension for VC-3

  This appendix defines the following optional additional Signal
  Type value for the Signal Type field of Section 2.1:

  Value         Type
  -----  ---------------------
   20     "VC-3 via AU-3 at the end"

  According to the ITU-T [G.707] recommendation, a VC-3 in the TU-
  3/TUG-3/VC-4/AU-4 branch of the SDH multiplex cannot be structured in
  TUG-2s; however, a VC-3 in the AU-3 branch can be.  In addition, a
  VC-3 could be switched between the two branches, if required.

  A VC-3 circuit could be terminated on an ingress interface of an LSR
  (e.g., forming a VC-3 forwarding adjacency).  This LSR could then
  want to demultiplex this VC-3 and switch internal low-order LSPs.
  For implementation reasons, this could be only possible if the LSR
  receives the VC-3 in the AU-3 branch.  For example, for an LSR not
  able to switch internally from a TU-3 branch to an AU-3 branch on its
  incoming interface before demultiplexing and then switching the
  content with its switch fabric.

  In that case, it is useful to indicate that the VC-3 LSP must be
  terminated at the end in the AU-3 branch instead of the TU-3 branch.

  This is achieved by using the "VC-3 via AU-3 at the end" signal type.
  This information can be used, for instance, by the penultimate LSR to
  switch an incoming VC-3 received in any branch to the AU-3 branch on
  the outgoing interface to the destination LSR.

  The "VC-3 via AU-3 at the end" signal type does not imply that the
  VC-3 must be switched via the AU-3 branch at some other places in the
  network.  The VC-3 signal type just indicates that a VC-3 in any
  branch is suitable.

Annex 1.  Examples

  This annex defines examples of SONET and SDH signal coding.  The
  objective is to help the reader to understand how the traffic
  parameter coding works and not to give examples of typical SONET or
  SDH signals.

  As stated above, signal types are Elementary Signals to which
  successive concatenation, multiplication, and transparency transforms
  can be applied to obtain Final Signals.





Mannie & Papadimitriou      Standards Track                    [Page 20]

RFC 4606        GMPLS Extensions for SONET & SDH Control     August 2006


  1.   A VC-4 signal is formed by the application of RCC with value 0,
       NCC with value 0, NVC with value 0, MT with value 1, and T with
       value 0 to a VC-4 Elementary Signal.

  2.   A VC-4-7v signal is formed by the application of RCC with value
       0, NCC with value 0, NVC with value 7 (virtual concatenation of
       7 components), MT with value 1, and T with value 0 to a VC-4
       Elementary Signal.

  3.   A VC-4-16c signal is formed by the application of RCC with value
       1 (standard contiguous concatenation), NCC with value 16, NVC
       with value 0, MT with value 1, and T with value 0 to a VC-4
       Elementary Signal.

  4.   An STM-16 signal with Multiplex Section layer transparency is
       formed by the application of RCC with value 0, NCC with value 0,
       NVC with value 0, MT with value 1, and T with flag 2 to an
       STM-16 Elementary Signal.

  5.   An STM-4 signal with Multiplex Section layer transparency is
       formed by the application of RCC with value 0, NCC with value 0,
       NVC with value 0, MT with value 1, and T with flag 2 applied to
       an STM-4 Elementary Signal.

  6.   An STM-256 signal with Multiplex Section layer transparency is
       formed by the application of RCC with value 0, NCC with value 0,
       NVC with value 0, MT with value 1, and T with flag 2 applied to
       an STM-256 Elementary Signal.

  7.   An STS-1 SPE signal is formed by the application of RCC with
       value 0, NCC with value 0, NVC with value 0, MT with value 1,
       and T with value 0 to an STS-1 SPE Elementary Signal.

  8.   An STS-3c SPE signal is formed by the application of RCC with
       value 1 (standard contiguous concatenation), NCC with value 1,
       NVC with value 0, MT with value 1, and T with value 0 to an
       STS-3c SPE Elementary Signal.

  9.   An STS-48c SPE signal is formed by the application of RCC with
       value 1 (standard contiguous concatenation), NCC with value 16,
       NVC with value 0, MT with value 1, and T with value 0 to an
       STS-3c SPE Elementary Signal.

  10.  An STS-1-3v SPE signal is formed by the application of RCC with
       value 0, NVC with value 3 (virtual concatenation of 3
       components), MT with value 1, and T with value 0 to an STS-1 SPE
       Elementary Signal.




Mannie & Papadimitriou      Standards Track                    [Page 21]

RFC 4606        GMPLS Extensions for SONET & SDH Control     August 2006


  11.  An STS-3c-9v SPE signal is formed by the application of RCC with
       value 1, NCC with value 1, NVC with value 9 (virtual
       concatenation of 9 STS-3c), MT with value 1, and T with value 0
       to an STS-3c SPE Elementary Signal.

  12.  An STS-12 signal with Section layer (full) transparency is
       formed by the application of RCC with value 0, NCC with value 0,
       NVC with value 0, MT with value 1, and T with flag 1 to an
       STS-12 Elementary Signal.

  13.  A 3 x STS-768c SPE signal is formed by the application of RCC
       with value 1, NCC with value 256, NVC with value 0, MT with
       value 3, and T with value 0 to an STS-3c SPE Elementary Signal.

  14.  A 5 x VC-4-13v composed signal is formed by the application of
       RCC with value 0, NVC with value 13, MT with value 5, and T with
       value 0 to a VC-4 Elementary Signal.

  The encoding of these examples is summarized in the following table:

  Signal                     ST   RCC   NCC   NVC   MT   T
  --------------------------------------------------------
  VC-4                        6     0     0     0    1   0
  VC-4-7v                     6     0     0     7    1   0
  VC-4-16c                    6     1    16     0    1   0
  STM-16 MS transparent      10     0     0     0    1   2
  STM-4 MS transparent        9     0     0     0    1   2
  STM-256 MS transparent     12     0     0     0    1   2
  STS-1 SPE                   5     0     0     0    1   0
  STS-3c SPE                  6     1     1     0    1   0
  STS-48c SPE                 6     1    16     0    1   0
  STS-1-3v SPE                5     0     0     3    1   0
  STS-3c-9v SPE               6     1     1     9    1   0
  STS-12 Section transparent  9     0     0     0    1   1
  3 x STS-768c SPE            6     1   256     0    3   0
  5 x VC-4-13v                6     0     0    13    5   0















Mannie & Papadimitriou      Standards Track                    [Page 22]

RFC 4606        GMPLS Extensions for SONET & SDH Control     August 2006


Normative References

  [G.707]     ITU-T Recommendation G.707, "Network Node Interface for
              the Synchronous Digital Hierarchy", October 2000.

  [RFC2119]   Bradner, S., "Key words for use in RFCs to Indicate
              Requirement Levels", BCP 14, RFC 2119, March 1997.

  [RFC2205]   Braden, R., Zhang, L., Berson, S., Herzog, S., and S.
              Jamin, "Resource ReSerVation Protocol (RSVP) -- Version 1
              Functional Specification", RFC 2205, September 1997.

  [RFC2210]   Wroclawski, J., "The Use of RSVP with IETF Integrated
              Services", RFC 2210, September 1997.

  [RFC3209]   Awduche, D., Berger, L., Gan, D., Li, T., Srinivasan, V.,
              and G. Swallow, "RSVP-TE: Extensions to RSVP for LSP
              Tunnels", RFC 3209, December 2001.

  [RFC3212]   Jamoussi, B., Andersson, L., Callon, R., Dantu, R., Wu,
              L., Doolan, P., Worster, T., Feldman, N., Fredette, A.,
              Girish, M., Gray, E., Heinanen, J., Kilty, T., and A.
              Malis, "Constraint-Based LSP Setup using LDP", RFC 3212,
              January 2002.

  [RFC3471]   Berger, L., "Generalized Multi-Protocol Label Switching
              (GMPLS) Signaling Functional Description", RFC 3471,
              January 2003.

  [RFC3472]   Ashwood-Smith, P. and L. Berger, "Generalized Multi-
              Protocol Label Switching (GMPLS) Signaling Constraint-
              based Routed Label Distribution Protocol (CR-LDP)
              Extensions", RFC 3472, January 2003.

  [RFC3473]   Berger, L., "Generalized Multi-Protocol Label Switching
              (GMPLS) Signaling Resource ReserVation Protocol-Traffic
              Engineering (RSVP-TE) Extensions", RFC 3473, January
              2003.

  [RFC3945]   Mannie, E., "Generalized Multi-Protocol Label Switching
              (GMPLS) Architecture", RFC 3945, October 2004.

  [T1.105]   "Synchronous Optical Network (SONET): Basic Description
              Including Multiplex Structure, Rates, and Formats", ANSI
              T1.105, October 2000.






Mannie & Papadimitriou      Standards Track                    [Page 23]

RFC 4606        GMPLS Extensions for SONET & SDH Control     August 2006


Authors' Addresses

  Eric Mannie
  Perceval
  Rue Tenbosch, 9
  1000 Brussels
  Belgium

  Phone: +32-2-6409194
  EMail: [email protected]


  Dimitri Papadimitriou
  Alcatel
  Copernicuslaan 50
  B-2018 Antwerpen, Belgium

  Phone: +32 3 240-8491
  EMail: [email protected]
































Mannie & Papadimitriou      Standards Track                    [Page 24]

RFC 4606        GMPLS Extensions for SONET & SDH Control     August 2006


Full Copyright Statement

  Copyright (C) The Internet Society (2006).

  This document is subject to the rights, licenses and restrictions
  contained in BCP 78, and except as set forth therein, the authors
  retain all their rights.

  This document and the information contained herein are provided on an
  "AS IS" basis and THE CONTRIBUTOR, THE ORGANIZATION HE/SHE REPRESENTS
  OR IS SPONSORED BY (IF ANY), THE INTERNET SOCIETY AND THE INTERNET
  ENGINEERING TASK FORCE DISCLAIM ALL WARRANTIES, EXPRESS OR IMPLIED,
  INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE
  INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED
  WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

Intellectual Property

  The IETF takes no position regarding the validity or scope of any
  Intellectual Property Rights or other rights that might be claimed to
  pertain to the implementation or use of the technology described in
  this document or the extent to which any license under such rights
  might or might not be available; nor does it represent that it has
  made any independent effort to identify any such rights.  Information
  on the procedures with respect to rights in RFC documents can be
  found in BCP 78 and BCP 79.

  Copies of IPR disclosures made to the IETF Secretariat and any
  assurances of licenses to be made available, or the result of an
  attempt made to obtain a general license or permission for the use of
  such proprietary rights by implementers or users of this
  specification can be obtained from the IETF on-line IPR repository at
  http://www.ietf.org/ipr.

  The IETF invites any interested party to bring to its attention any
  copyrights, patents or patent applications, or other proprietary
  rights that may cover technology that may be required to implement
  this standard.  Please address the information to the IETF at
  [email protected].

Acknowledgement

  Funding for the RFC Editor function is provided by the IETF
  Administrative Support Activity (IASA).







Mannie & Papadimitriou      Standards Track                    [Page 25]