Network Working Group                                   O. Nicklass, Ed.
Request for Comments: 3896                 RAD Data Communications, Ltd.
Obsoletes: 2496                                           September 2004
Category: Standards Track


     Definitions of Managed Objects for the DS3/E3 Interface Type

Status of this Memo

  This document specifies an Internet standards track protocol for the
  Internet community, and requests discussion and suggestions for
  improvements.  Please refer to the current edition of the "Internet
  Official Protocol Standards" (STD 1) for the standardization state
  and status of this protocol.  Distribution of this memo is unlimited.

Copyright Notice

  Copyright (C) The Internet Society (2004).

Abstract

  This memo defines a portion of the Management Information Base (MIB)
  for use with network management protocols in the Internet community.
  In particular, it describes objects used for managing DS3 and E3
  interfaces.  This document is a companion to the documents that
  define Managed Objects for the DS0, DS1/E1/DS2/E2 and Synchronous
  Optical Network/Synchronous Digital Hierarchy (SONET/SDH) Interface
  Types.  This document obsoletes RFC 2496.

Table of Contents

  1.   The Internet Standard Management Framework. . . . . . . . . .  2
       1.1.  Changes from RFC 2496 . . . . . . . . . . . . . . . . .  2
       1.2.  Changes from RFC 1407 . . . . . . . . . . . . . . . . .  3
       1.3.  Companion Documents . . . . . . . . . . . . . . . . . .  4
  2.   Overview. . . . . . . . . . . . . . . . . . . . . . . . . . .  4
       2.1.  Use of ifTable for DS3 Layer  . . . . . . . . . . . . .  4
       2.2.  Usage Guidelines. . . . . . . . . . . . . . . . . . . .  5
             2.2.1.  Usage of ifStackTable . . . . . . . . . . . . .  5
             2.2.2.  Usage of Channelization for DS3, DS1, DS0 . . .  7
             2.2.3.  Usage of Channelization for DS3, DS2, DS1 . . .  8
             2.2.4.  Usage of Loopbacks . . . . . . . . . . .  . . .  9
       2.3.  Objectives of this MIB Module . . . . . . . . . . . . . 10
       2.4.  DS3/E3 Terminology  . . . . . . . . . . . . . . . . . . 10
             2.4.1.  Error Events. . . . . . . . . . . . . . . . . . 10
             2.4.2.  Performance Parameters. . . . . . . . . . . . . 11
             2.4.3.  Performance Defects . . . . . . . . . . . . . . 14



Nicklass                    Standards Track                     [Page 1]

RFC 3896                       DS3/E3 MIB                 September 2004


             2.4.4.  Other Terms . . . . . . . . . . . . . . . . . . 16
  3.  Object Definitions . . . . . . . . . . . . . . . . . . . . . . 16
  4.  Appendix A - Use of the dsx3IfIndex and dsx3LineIndex. . . . . 54
  5.  Appendix B - The delay approach to Unavailable Seconds . . . . 56
  6.  Acknowledgments. . . . . . . . . . . . . . . . . . . . . . . . 58
  7.  References . . . . . . . . . . . . . . . . . . . . . . . . . . 58
      7.1.  Normative References . . . . . . . . . . . . . . . . . . 58
      7.2.  Informative References . . . . . . . . . . . . . . . . . 59
  8.  Security Considerations. . . . . . . . . . . . . . . . . . . . 60
  9.  Author's Address . . . . . . . . . . . . . . . . . . . . . . . 62
  10. Full Copyright Statement . . . . . . . . . . . . . . . . . . . 63

1.  The Internet Standard Management Framework

  For a detailed overview of the documents that describe the current
  Internet-Standard Management Framework, please refer to section 7 of
  RFC 3410 [RFC3410].

  Managed objects are accessed via a virtual information store, termed
  the Management Information Base or MIB.  MIB objects are generally
  accessed through the Simple Network Management Protocol (SNMP).
  Objects in the MIB are defined using the mechanisms defined in the
  Structure of Management Information (SMI).  This memo specifies a MIB
  module that is compliant to the SMIv2, which is described in STD 58,
  RFC 2578 [RFC2578], STD 58, RFC 2579 [RFC2579] and STD 58, RFC 2580
  [RFC2580].

1.1.  Changes from RFC 2496

  The changes from [RFC2496] are the following:

     (1) The dsx3FracIfIndex SYNTAX matches the description range.

     (2) Reference was added to Circuit Identifier object.

     (3) Usage of ifStackTable section was updated.

     (4) Align the DESCRIPTION clauses of few statistic objects with
         the near end definition, the far end definition and with
         [RFC3593].

     (5) Add new value, dsx3M13, to dsx3LineType.









Nicklass                    Standards Track                     [Page 2]

RFC 3896                       DS3/E3 MIB                 September 2004


1.2.  Changes from RFC 1407

  The changes from RFC 1407 are the following:

     (1)  The Fractional Table has been deprecated.

     (2)  This document uses SMIv2.

     (3)  Values are given for ifTable and ifXTable.

     (4)  Example usage of ifStackTable is included.

     (5)  dsx3IfIndex has been deprecated.

     (6)  The definition of valid intervals has been clarified for the
          case where the agent proxied for other devices. In
          particular, the treatment of missing intervals has been
          clarified.

     (7)  An inward loopback has been added.

     (8)  Additional lineStatus bits have been added for Near End in
          Unavailable Signal State, Carrier Equipment Out of Service.

     (9)  A read-write line Length object has been added.

     (10) Added a lineStatus last change, trap and enabler.

     (11) Textual Conventions for statistics objects have been used.

     (12) A new object, dsx3LoopbackStatus, has been introduced to
          reflect the loopbacks established on a DS3/E3 interface and
          the source to the requests.  dsx3LoopbackConfig continues to
          be the desired loopback state while dsx3LoopbackStatus
          reflects the actual state.

     (13) A dual loopback has been added to allow the setting of an
          inward loopback and a line loopback at the same time.

     (14) An object has been added to indicated whether or not this is
          a channelized DS3/E3.

     (15) A new object has been added to indicate which DS1 is to set
          for remote loopback.







Nicklass                    Standards Track                     [Page 3]

RFC 3896                       DS3/E3 MIB                 September 2004


1.3.  Companion Documents

          This document is a companion to the documents that define
          Managed Objects for the DS0 [RFC2494], DS1/E1/DS2/E2
          [RFC3895], and Synchronous Optical Network/Synchronous
          Digital Hierarchy (SONET/SDH) [RFC3592] Interface Types.

2.  Overview

  These objects are used when the particular media being used to
  realize an interface is a DS3/E3 interface.  At present, this applies
  to these values of the ifType variable in the Internet-standard MIB:

       ds3 (30)

  The DS3 definitions contained herein are based on the DS3
  specifications in ANSI T1.102-1987 [ANSI-T1.102], ANSI T1.107-1988
  [ANSI-T1.107], ANSI T1.107a-1990 [ANSI-T1.107a], and ANSI T1.404-1989
  [ANSI-T1.404].  The E3 definitions contained herein are based on the
  E3 specifications in CCITT G.751 [CCITT-G.751] and ETSI T/NA(91)18
  [ETSI-T/NA(91)18].

2.1.  Use of ifTable for DS3 Layer

  Only the ifGeneralInformationGroup needs to be supported.

          ifTable Object    Use for DS3 Layer
  ===================================================================
          ifIndex           Interface index.

          ifDescr           See interfaces MIB [RFC2863]

          ifType            ds3(30)

          ifSpeed           Speed of line rate
                            DS3 - 44736000
                            E3  - 34368000

          ifPhysAddress     The value of the Circuit Identifier.
                            If no Circuit Identifier has been assigned
                            this object should have an octet string
                            with zero length.

          ifAdminStatus     See interfaces MIB [RFC2863]

          ifOperStatus      See interfaces MIB [RFC2863]

          ifLastChange      See interfaces MIB [RFC2863]



Nicklass                    Standards Track                     [Page 4]

RFC 3896                       DS3/E3 MIB                 September 2004


          ifName            See interfaces MIB [RFC2863]

          ifLinkUpDownTrapEnable   Set to enabled(1).

          ifHighSpeed       Speed of line in Mega-bits per second
                            (either 45 or 34)

          ifConnectorPresent Set to true(1) normally, except for
                             cases such as DS3/E3 over AAL1/ATM where
                             false(2) is appropriate

2.2.  Usage Guidelines

2.2.1.  Usage of ifStackTable

  The object dsx3IfIndex has been deprecated.  This object previously
  allowed a very special proxy situation to exist for Routers and CSUs.
  This section now describes how to use ifStackTable to represent this
  relationship.

  The paragraphs discussing dsx3IfIndex and dsx3LineIndex have been
  preserved in Appendix A for informational purposes.

  The ifStackTable is used in the proxy case to represent the
  association between pairs of interfaces, e.g., this DS3 is attached
  to that DS3.  This use is consistent with the use of the ifStackTable
  to show the association between various sub-layers of an interface.
  In both cases entire PDUs are exchanged between the interface pairs -
  in the case of a DS3, entire DS3 frames are exchanged; in the case of
  PPP and HDLC, entire HDLC frames are exchanged.  This usage is not
  meant to suggest the use of the ifStackTable to represent Time
  Division Multiplexing (TDM) connections in general.

  External&Internal interface scenario: the SNMP Agent resides on a
  host external from the device supporting DS3/E3 interfaces (e.g., a
  router).  The Agent represents both the host and the DS3/E3 device.















Nicklass                    Standards Track                     [Page 5]

RFC 3896                       DS3/E3 MIB                 September 2004


  Example:

  A shelf full of CSUs connected to a Router.  An SNMP Agent residing
  on the router proxies for itself and the CSU.  The router has also an
  Ethernet interface:

        +-----+
  |     |     |
  |     |     |               +---------------------+
  |E    |     |  44.736 MBPS  |   ds3 M13    Line#A | ds3 C-bit Parity
  |t    |  R  |---------------+ - - - - -  - - -  - +------>
  |h    |     |               |                     |
  |e    |  O  |  44.736 MBPS  |   ds3 M13    Line#B | ds3 C-bit Parity
  |r    |     |---------------+ - - - - - - - - - - +------>
  |n    |  U  |               |                     |
  |e    |     |  44.736 MBPS  |   ds3 M13    Line#C | ds3 C-bit Parity
  |t    |  T  |---------------+ - - - -- -- - - - - +------>
  |     |     |               |                     |
  |-----|  E  |  44.736 MBPS  |   ds3 M13    Line#D | ds3 C-bit Parity
  |     |     |---------------+ -  - - - -- - - - - +------>
  |     |  R  |               |_____________________|
  |     |     |
  |     +-----+

  The assignment of the index values could for example be:

          ifIndex  Description
          1        Ethernet
          2        Line#A Router
          3        Line#B Router
          4        Line#C Router
          5        Line#D Router
          6        Line#A CSU Router
          7        Line#B CSU Router
          8        Line#C CSU Router
          9        Line#D CSU Router
          10       Line#A CSU Network
          11       Line#B CSU Network
          12       Line#C CSU Network
          13       Line#D CSU Network











Nicklass                    Standards Track                     [Page 6]

RFC 3896                       DS3/E3 MIB                 September 2004


  The ifStackTable is then used to show the relationships between the
  various DS3 interfaces.

          ifStackTable Entries

          HigherLayer   LowerLayer
          2             6
          3             7
          4             8
          5             9
          6             10
          7             11
          8             12
          9             13

  If the CSU shelf is managed by itself by a local SNMP Agent, the
  situation would be identical, except the Ethernet and the 4 router
  interfaces are deleted.  Interfaces would also be numbered from 1 to
  8.

          ifIndex  Description
          1        Line#A CSU Router
          2        Line#B CSU Router
          3        Line#C CSU Router
          4        Line#D CSU Router
          5        Line#A CSU Network
          6        Line#B CSU Network
          7        Line#C CSU Network
          8        Line#D CSU Network

          ifStackTable Entries

          HigherLayer   LowerLayer
          1             5
          2             6
          3             7
          4             8

2.2.2.  Usage of Channelization for DS3, DS1, DS0

  An example is given here to explain the channelization objects in the
  DS3, DS1, and DS0 MIBs to help the implementor use the objects
  correctly. Treatment of E3 and E1 would be similar, with the number
  of DS0s being different depending on the framing of the E1.







Nicklass                    Standards Track                     [Page 7]

RFC 3896                       DS3/E3 MIB                 September 2004


  Assume that a DS3 (with ifIndex 1) is Channelized into DS1s (without
  DS2s).  The object dsx3Channelization is set to enabledDs1.  When
  this object is set to enabledDS1, 28 ifEntries of type DS1 will be
  created by the agent. If dsx3Channelization is set to disabled, then
  the DS1s are destroyed.

  Assume the entries in the ifTable for the DS1s are created in channel
  order and the ifIndex values are 2 through 29. In the DS1 MIB, there
  will be an entry in the dsx1ChanMappingTable for each ds1.  The
  entries will be as follows:

          dsx1ChanMappingTable Entries

          ifIndex  dsx1Ds1ChannelNumber   dsx1ChanMappedIfIndex
          1        1                      2
          1        2                      3
          ......
          1        28                     29


  In addition, the DS1s are channelized into DS0s.  The object
  dsx1Channelization is set to enabledDS0 for each DS1.  There will be
  24 DS0s in the ifTable for each DS1.  Assume the entries in the
  ifTable are created in channel order and the ifIndex values for the
  DS0s in the first DS1 are 30 through 53.  In the DS0 MIB [RFC2494],
  there will be an entry in the dsx0ChanMappingTable for each DS0.  The
  entries will be as follows:

          dsx0ChanMappingTable Entries

          ifIndex   dsx0Ds0ChannelNumber  dsx0ChanMappedIfIndex
          2         1                     30
          2         2                     31
          ......
          2         24                    53

2.2.3.  Usage of Channelization for DS3, DS2, DS1

  An example is given here to explain the channelization objects in the
  DS3 and DS1 MIBs to help the implementor use the objects correctly.

  Assume that a DS3 (with ifIndex 1) is Channelized into DS2s.  The
  object dsx3Channelization is set to enabledDs2.  There will be 7 DS2s
  (ifType of DS1) in the ifTable.  Assume the entries in the ifTable
  for the DS2s are created in channel order and the ifIndex values are
  2 through 8.  In the DS1 MIB [RFC3895], there will be an entry in the
  dsx1ChanMappingTable for each DS2.  The entries will be as follows:




Nicklass                    Standards Track                     [Page 8]

RFC 3896                       DS3/E3 MIB                 September 2004


          dsx1ChanMappingTable Entries

          ifIndex  dsx1Ds1ChannelNumber   dsx1ChanMappedIfIndex
          1        1                      2
          1        2                      3
          ......
          1        7                      8

  In addition, the DS2s are channelized into DS1s.  The object
  dsx1Channelization is set to enabledDS1 for each DS2.  There will be
  4 DS1s in the ifTable for each DS2.  Assume the entries in the
  ifTable are created in channel order and the ifIndex values for the
  DS1s in the first DS2 are 9 through 12, then 13 through 16 for the
  second DS2, and so on.  In the DS1 MIB, there will be an entry in the
  dsx1ChanMappingTable for each DS1.  The entries will be as follows:

          dsx1ChanMappingTable Entries

          ifIndex   dsx1Ds1ChannelNumber  dsx1ChanMappedIfIndex
          2         1                     9
          2         2                     10
          2         3                     11
          2         4                     12
          3         1                     13
          3         2                     14
          ...
          8         4                     36

2.2.4.  Usage of Loopbacks

  This section discusses the behaviour of objects related to loopbacks.

  The object dsx3LoopbackConfig represents the desired state of
  loopbacks on this interface.  Using this object a Manager can
  request:
      LineLoopback
      PayloadLoopback (if ESF framing)
      InwardLoopback
      DualLoopback (Line + Inward)
      NoLoopback

  The remote end can also request lookbacks either through the FDL
  channel if ESF or inband if D4.  The loopbacks that can be requested
  this way are:

      LineLoopback
      PayloadLoopback (if ESF framing)
      NoLoopback



Nicklass                    Standards Track                     [Page 9]

RFC 3896                       DS3/E3 MIB                 September 2004


  To model the current state of loopbacks on a DS3 interface, the
  object dsx3LoopbackStatus defines which loopback is currently applied
  to an interface.  This object, which is a bitmap, will have bits
  turned on which reflect the currently active loopbacks on the
  interface as well as the source of those loopbacks.

  The following restrictions/rules apply to loopbacks:

  The far end cannot undo loopbacks set by a manager.

  A manager can undo loopbacks set by the far end.

  Both a line loopback and an inward loopback can be set at the same
  time.  Only these two loopbacks can co-exist and either one may be
  set by the manager or the far end.  A LineLoopback request from the
  far end is incremental to an existing Inward loopback established by
  a manager.  When a NoLoopback is received from the far end in this
  case, the InwardLoopback remains in place.

2.3.  Objectives of this MIB Module

  There are numerous things that could be included in a MIB for DS3/E3
  signals:  the management of multiplexors, CSUs, DSUs, and the like.
  The intent of this document is to facilitate the common management of
  all devices with DS3/E3 interfaces.  As such, a design decision was
  made up front to very closely align the MIB with the set of objects
  that can generally be read from DS3/E3 devices that are currently
  deployed.

2.4.  DS3/E3 Terminology

  The terminology used in this document to describe error conditions on
  a DS3 interface as monitored by a DS3 device are based on the late
  but not final draft of what became the ANSI T1.231 standard [ANSI-
  T1.231].  If the definition in this document does not match the
  definition in the ANSI T1.231 document, the implementer should follow
  the definition described in this document.

2.4.1.  Error Events

  Bipolar Violation (BPV) Error Event
        A bipolar violation error event, for B3ZS(HDB3)-coded signals,
        is the occurrence of a pulse of the same polarity as the
        previous pulse without being part of the zero substitution
        code, B3ZS(HDB3).  For B3ZS(HDB3)-coded signals, a bipolar
        violation error event may also include other error patterns
        such as:  three(four) or more consecutive zeros and incorrect
        polarity (See T1.231 section 7.1.1.1.1).



Nicklass                    Standards Track                    [Page 10]

RFC 3896                       DS3/E3 MIB                 September 2004


  Excessive Zeros (EXZ) Error Event
        An EXZ is the occurrence of any zero string length equal to or
        greater than 3 for B3ZS, or greater than 4 for HDB3 (See T1.231
        section 7.1.1.1.2).

  Line Coding Violation (LCV) Error Event
        This parameter is a count of both BPVs and EXZs occurring over
        the accumulation period.  An EXZ increments the LCV by one
        regardless of the length of the zero string. (Also known as
        CV-L.  See T1.231 section 7.4.1.1.)

  P-bit Coding Violation (PCV) Error Event
        For all DS3 applications, a coding violation error event is a
        P-bit Parity Error event.  A P-bit Parity Error event is the
        occurrence of a received P-bit code on the DS3 M-frame that is
        not identical to the corresponding locally-calculated code (See
        T1.231 section 7.1.1.2.1).

  C-bit Coding Violation (CCV) Error Event
        For C-bit Parity and SYNTRAN DS3 applications, this is the
        count of coding violations reported via the C-bits.  For C-bit
        Parity, it is a count of CP-bit parity errors occurring in the
        accumulation interval.  For SYNTRAN, it is a count of CRC-9
        errors occurring in the accumulation interval (See T1.231
        section 7.1.1.2.2).

2.4.2.  Performance Parameters

  All performance parameters are accumulated in fifteen minute
  intervals and up to 96 intervals (24 hours worth) are kept by an
  agent.  Fewer than 96 intervals of data will be available if the
  agent has been restarted within the last 24 hours.  In addition,
  there is a rolling 24-hour total of each performance parameter.

  There is no requirement for an agent to ensure fixed relationship
  between the start of a fifteen minute interval and any wall clock;
  however some agents may align the fifteen minute intervals with
  quarter hours.

  Performance parameters are of types PerfCurrentCount,
  PerfIntervalCount and PerfTotalCount.  These textual conventions are
  all Gauge32, and they are used because it is possible for these
  objects to decrease.  Objects may decrease when Unavailable Seconds
  occurs across a fifteen minutes interval boundary.  See Unavailable
  Seconds discussion later in this section.






Nicklass                    Standards Track                    [Page 11]

RFC 3896                       DS3/E3 MIB                 September 2004


  Line Errored Seconds (LES)
          A Line Errored Second is a second in which one or more CV
          occurred OR one or more LOS defects.  (Also known as ES-L.
          See T1.231 section 7.4.1.2.)

  P-bit Errored Seconds (PES)
          An PES is a second with one or more PCVs OR one or more Out
          of Frame defects OR a detected incoming AIS.  This gauge is
          not incremented when UASs are counted.  (Also known as ESP-P.
          See T1.231 section 7.4.2.2.)

  P-bit Severely Errored Seconds (PSES)
          A PSES is a second with 44 or more PCVs OR one or more Out of
          Frame defects OR a detected incoming AIS.  This gauge is not
          incremented when UASs are counted.  (Also known as SESP-P.
          See T1.231 section 7.4.2.5.)

  C-bit Errored Seconds (CES)
          An CES is a second with one or more CCVs OR one or more Out
          of Frame defects OR a detected incoming AIS.  This count is
          only for the SYNTRAN and C-bit Parity DS3 applications.  This
          gauge is not incremented when UASs are counted. (Also known
          as ESCP-P.  See T1.231 section 7.4.2.2.)

  C-bit Severely Errored Seconds (CSES)
          A CSES is a second with 44 or more CCVs OR one or more Out of
          Frame defects OR a detected incoming AIS.  This count is only
          for the SYNTRAN and C-bit Parity DS3 applications.  This
          gauge is not incremented when UASs are counted. (Also known
          as SESCP-P.  See T1.231 section 7.4.2.5.)

  Severely Errored Framing Seconds (SEFS)
          A SEFS is a second with one or more Out of Frame defects OR a
          detected incoming AIS.  This item is not incremented during
          unavailable seconds.  (Also known as SAS-P.  See T1.231
          section 7.4.2.6.)

  Unavailable Seconds (UAS)
          UAS are calculated by counting the number of seconds that the
          interface is unavailable.  The DS3 interface is said to be
          unavailable from the onset of 10 contiguous PSESs, or the
          onset of the condition leading to a failure (see Failure
          States).  If the condition leading to the failure was
          immediately preceded by one or more contiguous PSESs, then
          the DS3 interface unavailability starts from the onset of
          these PSESs.  Once unavailable, and if no failure is present,
          the DS3 interface becomes available at the onset of 10
          contiguous seconds with no PSESs.  Once unavailable, and if a



Nicklass                    Standards Track                    [Page 12]

RFC 3896                       DS3/E3 MIB                 September 2004


          failure is present, the DS3 interface becomes available at
          the onset of 10 contiguous seconds with no PSESs, if the
          failure clearing time is less than or equal to 10 seconds.
          If the failure clearing time is more than 10 seconds, the DS3
          interface becomes available at the onset of 10 contiguous
          seconds with no PSESs, or the onset period leading to the
          successful clearing condition, whichever occurs later.  With
          respect to the DS3 error counts, all counters are incremented
          while the DS3 interface is deemed available.  While the
          interface is deemed unavailable, the only count that is
          incremented is UASs.

          Note that this definition implies that the agent cannot
          determine until after a ten second interval has passed
          whether a given one-second interval belongs to available or
          unavailable time.  If the agent chooses to update the various
          performance statistics in real time then it must be prepared
          to retroactively reduce the PES, PSES, CES, and CSES counts
          by 10 and increase the UAS count by 10 when it determines
          that available time has been entered.  It must also be
          prepared to adjust the PCV, CCV, and SEFS count as necessary
          since these parameters are not accumulated during unavailable
          time.  Similarly, it must be prepared to retroactively
          decrease the UAS count by 10 and increase the PES, CES, PCV,
          and CCV counts as necessary upon entering available time.  A
          special case exists when the 10 second period leading to
          available or unavailable time crosses a 900 second statistics
          window boundary, as the foregoing description implies that
          the PCV, CCV, PES, CES, PSES, CSEC, SEFS, and UAS counts for
          the PREVIOUS interval must be adjusted.  In this case
          successive GETs of the affected dsx3IntervalPSESs and
          dsx3IntervalUASs objects will return differing values if the
          first GET occurs during the first few seconds of the window.

          The agent may instead choose to delay updates to the various
          statistics by 10 seconds in order to avoid retroactive
          adjustments to the counters.  A way to do this is sketched in
          Appendix B.

  In any case, a linkDown trap shall be sent only after the agent has
  determined for certain that the unavailable state has been entered,
  but the time on the trap will be that of the first UAS (i.e., 10
  seconds earlier).  A linkUp trap shall be handled similarly.

  According to [ANSI-T1.231] unavailable time begins at the _onset_ of
  10 contiguous severely errored seconds -- that is, unavailable time
  starts with the _first_ of the 10 contiguous SESs.  Also, while an
  interface is deemed unavailable all counters for that interface are



Nicklass                    Standards Track                    [Page 13]

RFC 3896                       DS3/E3 MIB                 September 2004


  frozen except for the UAS count.  It follows that an implementation
  which strictly complies with this standard must _not_ increment any
  counters other than the UAS count -- even temporarily -- as a result
  of anything that happens during those 10 seconds.  Since changes in
  the signal state lag the data to which they apply by 10 seconds, an
  ANSI-compliant implementation must pass the one-second statistics
  through a 10-second delay line prior to updating any counters.  That
  can be done by performing the following steps at the end of each one
  second interval.

     i)   Read near/far end CV counter and alarm status flags from the
          hardware.

     ii)  Accumulate the CV counts for the preceding second and compare
          them to the ES and SES threshold for the layer in question.
          Update the signal state and shift the one-second CV counts
          and ES/SES flags into the 10-element delay line.  Note that
          far-end one-second statistics are to be flagged as "absent"
          during any second in which there is an incoming defect at the
          layer in question or at any lower layer.

     iii) Update the current interval statistics using the signal state
          from the _previous_ update cycle and the one-second CV counts
          and ES/SES flags shifted out of the 10-element delay line.

  This approach is further described in Appendix B.

2.4.3.  Performance Defects

  Failure States:
          The Remote Alarm Indication (RAI) failure, in SYNTRAN
          applications, is declared after detecting the Yellow Alarm
          Signal on the alarm channel.  See ANSI T1.107a-1990 [ANSI-
          T1.107a].  The Remote Alarm Indication failure, in C-bit
          Parity DS3 applications, is declared as soon as the presence
          of either one or two alarm signals are detected on the Far
          End Alarm Channel.  See [ANSI-T1.107].  The Remote Alarm
          Indication failure may also be declared after detecting the
          far-end SEF/AIS defect (aka yellow).  The Remote Alarm
          Indication failure is cleared as soon as the presence of the
          any of the above alarms are removed.

          Also, the incoming failure state is declared when a defect
          persists for at least 2-10 seconds.  The defects are the
          following:  Loss of Signal (LOS), an Out of Frame (OOF) or an
          incoming Alarm Indication Signal (AIS).  The Failure State is
          cleared when the defect is absent for less than or equal to
          20 seconds.



Nicklass                    Standards Track                    [Page 14]

RFC 3896                       DS3/E3 MIB                 September 2004


  Far End SEF/AIS defect (aka yellow)
          A Far End SEF/AIS defect is the occurrence of the two X-bits
          in a M-frame set to zero.  The Far End SEF/AIS defect is
          terminated when the two X-bits in a M-frame are set to one.
          (Also known as SASCP-PFE.  See T1.231 section 7.4.4.2.6)

  Out of Frame (OOF) defect
          A DS3 OOF defect is detected when any three or more errors in
          sixteen or fewer consecutive F-bits occur within a DS3 M-
          frame.  An OOF defect may also be called a Severely Errored
          Frame (SEF) defect.  An OOF defect is cleared when reframe
          occurs.  A DS3 Loss of Frame (LOF) failure is declared when
          the DS3 OOF defect is consistent for 2 to 10 seconds.  The
          DS3 OOF defect ends when reframe occurs.  The DS3 LOF failure
          is cleared when the DS3 OOF defect is absent for 10 to 20
          seconds. (See T1.231 section 7.1.2.2.1)

          An E3 OOF defect is detected when four consecutive frame
          alignment signals have been incorrectly received in there
          predicted positions in an E3 signal.  E3 frame alignment
          occurs when the presence of three consecutive frame alignment
          signals have been detected.

  Loss of Signal (LOS) defect
          The DS3 LOS defect is declared upon observing 175 +/- 75
          contiguous pulse positions with no pulses of either positive
          or negative polarity.  The DS3 LOS defect is terminated upon
          observing an average pulse density of at least 33% over a
          period of 175 +/- 75 contiguous pulse positions starting with
          the receipt of a pulse. (See T1.231 section 7.1.2.1.1)

  Alarm Indication Signal (AIS) defect
          The DS3 AIS is framed with "stuck stuffing."  This implies
          that it has a valid M-subframe alignments bits, M-frame
          alignment bits, and P bits.  The information bits are set to
          a 1010... sequence, starting with a one (1) after each M-
          subframe alignment bit, M-frame alignment bit, X bit, P bit,
          and C bit.  The C bits are all set to zero giving what is
          called "stuck stuffing."  The X bits are set to one.  The DS3
          AIS defect is declared after DS3 AIS is present in contiguous
          M-frames for a time equal to or greater than T, where 0.2 ms
          <= T <= 100 ms.  The DS3 AIS defect is terminated after AIS
          is absent in contiguous M-frames for a time equal to or
          greater than T.  (See T1.231 section 7.1.2.2.3)







Nicklass                    Standards Track                    [Page 15]

RFC 3896                       DS3/E3 MIB                 September 2004


          The E3 binary content of the AIS is nominally a continuous
          stream of ones.  AIS detection and the application of
          consequent actions, should be completed within a time limit
          of 1 ms.

2.4.4.  Other Terms

  Circuit Identifier
          This is a character string specified by the circuit vendor,
          and is useful when communicating with the vendor during the
          troubleshooting process (see M.1400 [ITU-T-M.1400] for
          additional information).

  Proxy
          In this document, the word proxy is meant to indicate an
          application which receives SNMP messages and replies to them
          on behalf of the devices which implement the actual DS3/E3
          interfaces.  The proxy may have already collected the
          information about the DS3/E3 interfaces into its local
          database and may not necessarily forward the requests to the
          actual DS3/E3 interface.  It is expected in such an
          application that there are periods of time where the proxy is
          not communicating with the DS3/E3 interfaces.  In these
          instances the proxy will not necessarily have up-to-date
          configuration information and will most likely have missed
          the collection of some statistics data.  Missed statistics
          data collection will result in invalid data in the interval
          table.

3.  Object Definitions

  DS3-MIB DEFINITIONS ::= BEGIN

  IMPORTS
       MODULE-IDENTITY, OBJECT-TYPE,
       NOTIFICATION-TYPE, transmission
            FROM SNMPv2-SMI                    -- [RFC2578]
       DisplayString, TimeStamp, TruthValue
            FROM SNMPv2-TC                     -- [RFC2579]
       MODULE-COMPLIANCE, OBJECT-GROUP,
       NOTIFICATION-GROUP
            FROM SNMPv2-CONF                   -- [RFC2580]
       InterfaceIndex
            FROM IF-MIB                        -- [RFC2863]
       PerfCurrentCount, PerfIntervalCount,
       PerfTotalCount
            FROM PerfHist-TC-MIB;              -- [RFC3593]




Nicklass                    Standards Track                    [Page 16]

RFC 3896                       DS3/E3 MIB                 September 2004


  ds3 MODULE-IDENTITY
      LAST-UPDATED "200409080000Z"  -- September 08, 2004
      ORGANIZATION "IETF AToM MIB Working Group"
      CONTACT-INFO
        "WG charter:
           http://www.ietf.org/html.charters/atommib-charter.html

         Mailing Lists:
           General Discussion: [email protected]
           To Subscribe: [email protected]

         Editor: Orly Nicklass

         Postal: RAD Data Communications, Ltd.
                 Ziv Tower, 24 Roul Walenberg
                 Tel Aviv, Israel, 69719

                 Tel: +9723 765 9969
         E-mail: [email protected]"

      DESCRIPTION
           "The is the MIB module that describes
            DS3 and E3 interfaces objects.

            Copyright (c) The Internet Society (2004).  This
            version of this MIB module is part of RFC 3896;
            see the RFC itself for full legal notices."

      REVISION "200409080000Z"  -- September 08, 2004

       DESCRIPTION
            "The RFC 3896 version of this MIB module.
            The key changes made to this MIB module
            since its publication in RFC 2496 are as follows:

        (1) The dsx3FracIfIndex SYNTAX matches the description range.

        (2) Reference was added to Circuit Identifier object.

        (3) Usage of ifStackTable section was updated.

        (4) Align the DESCRIPTION clauses of few statistic objects with
            thenear end definition, the far end definition and with
            RFC 3593.

        (5) Add new value, dsx3M13, to dsx3LineType."

       REVISION "199808012130Z"



Nicklass                    Standards Track                    [Page 17]

RFC 3896                       DS3/E3 MIB                 September 2004


       DESCRIPTION
            "The RFC 2496 version of this MIB module.
            The key changes made to this MIB module
            since its publication in RFC 1407 are as follows:

           (1)  The Fractional Table has been deprecated.

           (2)  This document uses SMIv2.

           (3)  Values are given for ifTable and ifXTable.

           (4)  Example usage of ifStackTable is included.

           (5)  dsx3IfIndex has been deprecated.

           (6)  The definition of valid intervals has been clarified
                for the case where the agent proxied for other devices.
                In particular, the treatment of missing intervals has
                been clarified.

          (7)  An inward loopback has been added.

          (8)  Additional lineStatus bits have been added for Near End
               in Unavailable Signal State, Carrier Equipment Out of
               Service.

          (9)  A read-write line Length object has been added.

          (10) Added a lineStatus last change, trap and enabler.

          (11) Textual Conventions for statistics objects have
               been used.

          (12) A new object, dsx3LoopbackStatus, has been introduced to
               reflect the loopbacks established on a DS3/E3 interface
               and the source to the requests.  dsx3LoopbackConfig
               continues to be the desired loopback state while
               dsx3LoopbackStatus reflects the actual state.

          (13) A dual loopback has been added to allow the setting of
               an inward loopback and a line loopback at the same time.

          (14) An object has been added to indicated whether or not
               this is a channelized DS3/E3.

          (15) A new object has been added to indicate which DS1 is to
               set for remote loopback."




Nicklass                    Standards Track                    [Page 18]

RFC 3896                       DS3/E3 MIB                 September 2004


      REVISION "199301252028Z"
      DESCRIPTION
           "Initial version, published as RFC 1407."
      ::= { transmission 30 }

  -- The DS3/E3 Near End Group

  -- The DS3/E3 Near End Group consists of four tables:
  --    DS3/E3 Configuration
  --    DS3/E3 Current
  --    DS3/E3 Interval
  --    DS3/E3 Total

  -- the DS3/E3 Configuration Table

  dsx3ConfigTable OBJECT-TYPE
       SYNTAX  SEQUENCE OF Dsx3ConfigEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
              "The DS3/E3 Configuration table."
       ::= { ds3 5 }

  dsx3ConfigEntry OBJECT-TYPE
       SYNTAX  Dsx3ConfigEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
              "An entry in the DS3/E3 Configuration table."
       INDEX   { dsx3LineIndex }
       ::= { dsx3ConfigTable 1 }

  Dsx3ConfigEntry ::=
       SEQUENCE {
           dsx3LineIndex                        InterfaceIndex,
           dsx3IfIndex                          InterfaceIndex,
           dsx3TimeElapsed                      INTEGER,
           dsx3ValidIntervals                   INTEGER,
           dsx3LineType                         INTEGER,
           dsx3LineCoding                       INTEGER,
           dsx3SendCode                         INTEGER,
           dsx3CircuitIdentifier                DisplayString,
           dsx3LoopbackConfig                   INTEGER,
           dsx3LineStatus                       INTEGER,
           dsx3TransmitClockSource              INTEGER,
           dsx3InvalidIntervals                 INTEGER,
           dsx3LineLength                       INTEGER,
           dsx3LineStatusLastChange             TimeStamp,



Nicklass                    Standards Track                    [Page 19]

RFC 3896                       DS3/E3 MIB                 September 2004


           dsx3LineStatusChangeTrapEnable       INTEGER,
           dsx3LoopbackStatus                   INTEGER,
           dsx3Channelization                   INTEGER,
           dsx3Ds1ForRemoteLoop                 INTEGER

  }

  dsx3LineIndex OBJECT-TYPE
       SYNTAX  InterfaceIndex
       MAX-ACCESS  read-only  -- read-only since originally an
                              -- SMIv1 index

       STATUS  current
       DESCRIPTION
              "This object should be made equal to ifIndex.  The
              next paragraph describes its previous usage.
              Making the object equal to ifIndex allows proper
              use of ifStackTable.

              Previously, this object was the identifier of a
              DS3/E3 Interface on a managed device.  If there is
              an ifEntry that is directly associated with this
              and only this DS3/E3 interface, it should have the
              same value as ifIndex.  Otherwise, number the
              dsx3LineIndices with an unique identifier
              following the rules of choosing a number that is
              greater than ifNumber and numbering the inside
              interfaces (e.g., equipment side) with even
              numbers and outside interfaces (e.g., network side)
              with odd numbers."
       ::= { dsx3ConfigEntry 1 }

  dsx3IfIndex OBJECT-TYPE
       SYNTAX  InterfaceIndex
       MAX-ACCESS  read-only
       STATUS  deprecated
       DESCRIPTION
              "This value for this object is equal to the value
              of ifIndex from the Interfaces table of MIB II
              (RFC 1213)."
       ::= { dsx3ConfigEntry 2 }

  dsx3TimeElapsed OBJECT-TYPE
       SYNTAX  INTEGER (0..899)
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
              "The number of seconds that have elapsed since the



Nicklass                    Standards Track                    [Page 20]

RFC 3896                       DS3/E3 MIB                 September 2004


              beginning of the near end current error-
              measurement period. If, for some reason, such as
              an adjustment in the system's time-of-day clock,
              the current interval exceeds the maximum value,
              the agent will return the maximum value."
       ::= { dsx3ConfigEntry 3 }

  dsx3ValidIntervals OBJECT-TYPE
       SYNTAX  INTEGER (0..96)
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
              "The number of previous near end intervals for
              which data was collected.  The value will be 96
              unless the interface was brought online within the
              last 24 hours, in which case the value will be the
              number of complete 15 minute near end intervals
              since the interface has been online.  In the case
              where the agent is a proxy, it is possible that
              some intervals are unavailable.  In this case,
              this interval is the maximum interval number for
              which data is available."
       ::= { dsx3ConfigEntry 4 }

  dsx3LineType OBJECT-TYPE
       SYNTAX  INTEGER {
                  dsx3other(1),
                  dsx3M23(2),
                  dsx3SYNTRAN(3),
                  dsx3CbitParity(4),
                  dsx3ClearChannel(5),
                  e3other(6),
                  e3Framed(7),
                  e3Plcp(8),
                  dsx3M13(9)
              }
       MAX-ACCESS  read-write
       STATUS  current
       DESCRIPTION
              "This variable indicates the variety of DS3 C-bit
              or E3 application implementing this interface. The
              type of interface affects the interpretation of
              the usage and error statistics.  The rate of DS3
              is 44.736 Mbps and E3 is 34.368 Mbps.  The
              dsx3ClearChannel value means that the C-bits are
              not used except for sending/receiving AIS.  The
              values, in sequence, describe:




Nicklass                    Standards Track                    [Page 21]

RFC 3896                       DS3/E3 MIB                 September 2004


                             TITLE:          SPECIFICATION:
                             dsx3M23         ANSI T1.107-1988
                             dsx3SYNTRAN     ANSI T1.107-1988
                             dsx3CbitParity  ANSI T1.107a-1990
                             dsx3ClearChannel ANSI T1.102-1987
                             e3Framed        CCITT G.751
                             e3Plcp          ETSI T/NA(91)18
                             dsx3M13         ANSI T1.107a-1990."

      REFERENCE
              "American National Standard for telecommunications
                   - digital hierarchy -
                   formats specification, ANSI T1.107- 1988.
                   ANSI T1.107a-1990.
               American National Standard for telecommunications
                   - digital hierarchy -
                   electrical interfaces, ANSI T1.102- 1987.
               CCITT - Digital Multiplex Equipment Operating at
                   the Third Order Bit Rate of 34 368 Kbit/s and
                   the Forth Order Bit Rate of 139 264 Kbit/s
                   and Using Positive Justification, G.751
               European Telecommunications Standards Institute
                   -- ETS '34M' --
                   Metropolitan Area Network Physical
                   Convergence Layer Procedure for
                   34.368 Megabits per Second, T/NA(91)18,
                   May 1991."
       ::= { dsx3ConfigEntry 5 }

  dsx3LineCoding OBJECT-TYPE
       SYNTAX  INTEGER {
                  dsx3Other(1),
                  dsx3B3ZS(2),
                  e3HDB3(3)
              }
       MAX-ACCESS  read-write
       STATUS  current
       DESCRIPTION
              "This variable describes the variety of Zero Code
              Suppression used on this interface, which in turn
              affects a number of its characteristics.
              dsx3B3ZS and e3HDB3 refer to the use of specified
              patterns of normal bits and bipolar violations
              which are used to replace sequences of zero bits
              of a specified length."
       ::= { dsx3ConfigEntry 6 }

  dsx3SendCode OBJECT-TYPE



Nicklass                    Standards Track                    [Page 22]

RFC 3896                       DS3/E3 MIB                 September 2004


       SYNTAX  INTEGER {
                 dsx3SendNoCode(1),
                 dsx3SendLineCode(2),
                 dsx3SendPayloadCode(3),
                 dsx3SendResetCode(4),
                 dsx3SendDS1LoopCode(5),
                 dsx3SendTestPattern(6)
                 }
       MAX-ACCESS  read-write
       STATUS  current
       DESCRIPTION
              "This variable indicates what type of code is
              being sent across the DS3/E3 interface by the
              device.  (These are optional for E3 interfaces.)
              Setting this variable causes the interface to
              begin sending the code requested.
              The values mean:

                 dsx3SendNoCode
                     sending looped or normal data

                 dsx3SendLineCode
                     sending a request for a line loopback

                 dsx3SendPayloadCode
                     sending a request for a payload loopback
                     (i.e., all DS1/E1s in a DS3/E3 frame)

                 dsx3SendResetCode
                     sending a loopback deactivation request

                 dsx3SendDS1LoopCode
                     requesting to loopback a particular DS1/E1
                     within a DS3/E3 frame.  The DS1/E1 is
                     indicated in dsx3Ds1ForRemoteLoop.

                 dsx3SendTestPattern
                     sending a test pattern."
       ::= { dsx3ConfigEntry 7 }

  dsx3CircuitIdentifier OBJECT-TYPE
       SYNTAX  DisplayString (SIZE (0..255))
       MAX-ACCESS  read-write
       STATUS  current
       DESCRIPTION
              "This variable contains the transmission vendor's
              circuit identifier, for the purpose of
              facilitating troubleshooting."



Nicklass                    Standards Track                    [Page 23]

RFC 3896                       DS3/E3 MIB                 September 2004


       REFERENCE "ITU-T M.1400"
       ::= { dsx3ConfigEntry 8 }

  dsx3LoopbackConfig OBJECT-TYPE
       SYNTAX  INTEGER {
                   dsx3NoLoop(1),
                   dsx3PayloadLoop(2),
                   dsx3LineLoop(3),
                   dsx3OtherLoop(4),
                   dsx3InwardLoop(5),
                   dsx3DualLoop(6)
                 }
       MAX-ACCESS  read-write
       STATUS  current
       DESCRIPTION
            "This variable represents the desired loopback
            configuration of the DS3/E3 interface.
            The values mean:

            dsx3NoLoop
              Not in the loopback state.  A device that is
              not capable of performing a loopback on
              the interface shall always return this as
              its value.

            dsx3PayloadLoop
              The received signal at this interface is looped
              through the device.  Typically the received signal
              is looped back for retransmission after it has
              passed through the device's framing function.

            dsx3LineLoop
              The received signal at this interface does not
              go through the device (minimum penetration) but
              is looped back out.

            dsx3OtherLoop
              Loopbacks that are not defined here.

            dsx3InwardLoop
              The sent signal at this interface is looped back
              through the device.

            dsx3DualLoop
              Both dsx1LineLoop and dsx1InwardLoop will be
              active simultaneously."
       ::= { dsx3ConfigEntry 9 }




Nicklass                    Standards Track                    [Page 24]

RFC 3896                       DS3/E3 MIB                 September 2004


  dsx3LineStatus OBJECT-TYPE
       SYNTAX  INTEGER (1..4095)
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
              "This variable indicates the Line Status of the
              interface.  It contains loopback state information
              and failure state information.  The dsx3LineStatus
              is a bit map represented as a sum, therefore, it
              can represent multiple failures and a loopback
              (see dsx3LoopbackConfig object for the type of
              loopback) simultaneously.  The dsx3NoAlarm must be
              set if and only if no other flag is set.

              If the dsx3loopbackState bit is set, the loopback
              in effect can be determined from the
              dsx3loopbackConfig object.
         The various bit positions are:
          1     dsx3NoAlarm         No alarm present
          2     dsx3RcvRAIFailure   Receiving Yellow/Remote
                                    Alarm Indication
          4     dsx3XmitRAIAlarm    Transmitting Yellow/Remote
                                    Alarm Indication
          8     dsx3RcvAIS          Receiving AIS failure state
         16     dsx3XmitAIS         Transmitting AIS
         32     dsx3LOF             Receiving LOF failure state
         64     dsx3LOS             Receiving LOS failure state
        128     dsx3LoopbackState   Looping the received signal
        256     dsx3RcvTestCode     Receiving a Test Pattern
        512     dsx3OtherFailure    any line status not defined
                                    here
       1024     dsx3UnavailSigState Near End in Unavailable
                                    Signal State
       2048     dsx3NetEquipOOS     Carrier Equipment Out of
                                    Service"
       ::= { dsx3ConfigEntry 10 }

  dsx3TransmitClockSource OBJECT-TYPE
       SYNTAX  INTEGER {
                  loopTiming(1),
                  localTiming(2),
                  throughTiming(3)
              }
       MAX-ACCESS  read-write
       STATUS  current
       DESCRIPTION
              "The source of Transmit Clock.




Nicklass                    Standards Track                    [Page 25]

RFC 3896                       DS3/E3 MIB                 September 2004


              loopTiming indicates that the recovered receive
              clock is used as the transmit clock.

              localTiming indicates that a local clock source is
              used or that an external clock is attached to the
              box containing the interface.

              throughTiming indicates that transmit clock is
              derived from the recovered receive clock of
              another DS3 interface."
       ::= { dsx3ConfigEntry 11 }

  dsx3InvalidIntervals OBJECT-TYPE
       SYNTAX  INTEGER (0..96)
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
              " The number of intervals in the range from 0 to
              dsx3ValidIntervals for which no data is available.
              This object will typically be zero except in cases
              where the data for some intervals are not
              available (e.g., in proxy situations)."
       ::= { dsx3ConfigEntry 12 }

  dsx3LineLength OBJECT-TYPE
       SYNTAX  INTEGER (0..64000)
       UNITS "meters"
       MAX-ACCESS  read-write
       STATUS  current
       DESCRIPTION
              "The length of the ds3 line in meters.  This
              object provides information for line build out
              circuitry if it exists and can use this object to
              adjust the line build out."
       ::= { dsx3ConfigEntry 13 }

  dsx3LineStatusLastChange OBJECT-TYPE
       SYNTAX  TimeStamp
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
              "The value of MIB II's sysUpTime object at the
              time this DS3/E3 entered its current line status
              state.  If the current state was entered prior to
              the last re-initialization of the proxy-agent,
              then this object contains a zero value."
       ::= { dsx3ConfigEntry 14 }




Nicklass                    Standards Track                    [Page 26]

RFC 3896                       DS3/E3 MIB                 September 2004


  dsx3LineStatusChangeTrapEnable  OBJECT-TYPE
       SYNTAX      INTEGER {
                      enabled(1),
                      disabled(2)
                   }
       MAX-ACCESS  read-write
       STATUS      current
       DESCRIPTION
              "Indicates whether dsx3LineStatusChange traps
              should be generated for this interface."
       DEFVAL { disabled }
       ::= { dsx3ConfigEntry 15 }

  dsx3LoopbackStatus  OBJECT-TYPE
       SYNTAX      INTEGER (1..127)
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
              "This variable represents the current state of the
              loopback on the DS3 interface.  It contains
              information about loopbacks established by a
              manager and remotely from the far end.

              The dsx3LoopbackStatus is a bit map represented as
              a sum, therefore is can represent multiple
              loopbacks simultaneously.

              The various bit positions are:
               1  dsx3NoLoopback
               2  dsx3NearEndPayloadLoopback
               4  dsx3NearEndLineLoopback
               8  dsx3NearEndOtherLoopback
              16  dsx3NearEndInwardLoopback
              32  dsx3FarEndPayloadLoopback
              64  dsx3FarEndLineLoopback"
       ::= { dsx3ConfigEntry 16 }

  dsx3Channelization  OBJECT-TYPE
       SYNTAX      INTEGER {
                      disabled(1),
                      enabledDs1(2),
                      enabledDs2(3)
                   }
       MAX-ACCESS  read-write
       STATUS      current
       DESCRIPTION
              "Indicates whether this ds3/e3 is channelized or
              unchannelized.  The value of enabledDs1 indicates



Nicklass                    Standards Track                    [Page 27]

RFC 3896                       DS3/E3 MIB                 September 2004


              that this is a DS3 channelized into DS1s.  The
              value of enabledDs3 indicated that this is a DS3
              channelized into DS2s.  Setting this object will
              cause the creation or deletion of DS2 or DS1
              entries in the ifTable.  "
       ::= { dsx3ConfigEntry 17 }

  dsx3Ds1ForRemoteLoop  OBJECT-TYPE
       SYNTAX      INTEGER (0..29)
       MAX-ACCESS  read-write
       STATUS      current
       DESCRIPTION
              "Indicates which DS1/E1 on this DS3/E3 will be
              indicated in the remote ds1 loopback request.  A
              value of 0 means no DS1 will be looped.  A value
              of 29 means all DS1s/E1s will be looped."
       ::= { dsx3ConfigEntry 18 }

  -- the DS3/E3 Current Table


  dsx3CurrentTable OBJECT-TYPE
       SYNTAX  SEQUENCE OF Dsx3CurrentEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
              "The DS3/E3 current table contains various
              statistics being collected for the current 15
              minute interval."
       ::= { ds3 6 }

  dsx3CurrentEntry OBJECT-TYPE
       SYNTAX  Dsx3CurrentEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
              "An entry in the DS3/E3 Current table."
       INDEX   { dsx3CurrentIndex }
       ::= { dsx3CurrentTable 1 }

  Dsx3CurrentEntry ::=
       SEQUENCE {
           dsx3CurrentIndex           InterfaceIndex,
           dsx3CurrentPESs            PerfCurrentCount,
           dsx3CurrentPSESs           PerfCurrentCount,
           dsx3CurrentSEFSs           PerfCurrentCount,
           dsx3CurrentUASs            PerfCurrentCount,
           dsx3CurrentLCVs            PerfCurrentCount,



Nicklass                    Standards Track                    [Page 28]

RFC 3896                       DS3/E3 MIB                 September 2004


           dsx3CurrentPCVs            PerfCurrentCount,
           dsx3CurrentLESs            PerfCurrentCount,
           dsx3CurrentCCVs            PerfCurrentCount,
           dsx3CurrentCESs            PerfCurrentCount,
           dsx3CurrentCSESs           PerfCurrentCount
      }

  dsx3CurrentIndex OBJECT-TYPE
       SYNTAX  InterfaceIndex
       MAX-ACCESS  read-only  -- read-only since originally an
                              -- SMIv1 index
       STATUS  current
       DESCRIPTION
              "The index value which uniquely identifies the
              DS3/E3 interface to which this entry is
              applicable.  The interface identified by a
              particular value of this index is the same
              interface as identified by the same value an
              dsx3LineIndex object instance."
       ::= { dsx3CurrentEntry 1 }

  dsx3CurrentPESs OBJECT-TYPE
       SYNTAX  PerfCurrentCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
              "The counter associated with the number of P-bit
              Errored Seconds."
       ::= { dsx3CurrentEntry 2 }

  dsx3CurrentPSESs OBJECT-TYPE
       SYNTAX  PerfCurrentCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
              "The counter associated with the number of P-bit
              Severely Errored Seconds."
       ::= { dsx3CurrentEntry 3 }

  dsx3CurrentSEFSs OBJECT-TYPE
       SYNTAX  PerfCurrentCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
              "The counter associated with the number of
              Severely Errored Framing Seconds."
       ::= { dsx3CurrentEntry 4 }




Nicklass                    Standards Track                    [Page 29]

RFC 3896                       DS3/E3 MIB                 September 2004


  dsx3CurrentUASs OBJECT-TYPE
       SYNTAX  PerfCurrentCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
              "The counter associated with the number of
              Unavailable Seconds."
       ::= { dsx3CurrentEntry 5 }

  dsx3CurrentLCVs OBJECT-TYPE
       SYNTAX  PerfCurrentCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
              "The counter associated with the number of Line
              Coding Violations."
       ::= { dsx3CurrentEntry 6 }

  dsx3CurrentPCVs OBJECT-TYPE
       SYNTAX  PerfCurrentCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
              "The counter associated with the number of P-bit
              Coding Violations."
       ::= { dsx3CurrentEntry 7 }

  dsx3CurrentLESs OBJECT-TYPE
       SYNTAX  PerfCurrentCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
              "The number of Line Errored Seconds."
       ::= { dsx3CurrentEntry 8 }

  dsx3CurrentCCVs OBJECT-TYPE
       SYNTAX  PerfCurrentCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
              "The number of C-bit Coding Violations."
       ::= { dsx3CurrentEntry 9 }

  dsx3CurrentCESs OBJECT-TYPE
       SYNTAX  PerfCurrentCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION



Nicklass                    Standards Track                    [Page 30]

RFC 3896                       DS3/E3 MIB                 September 2004


              "The number of C-bit Errored Seconds."
       ::= { dsx3CurrentEntry 10 }

  dsx3CurrentCSESs OBJECT-TYPE
       SYNTAX  PerfCurrentCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
              "The number of C-bit Severely Errored Seconds."
       ::= { dsx3CurrentEntry 11 }

  -- the DS3/E3 Interval Table

  dsx3IntervalTable OBJECT-TYPE
       SYNTAX  SEQUENCE OF Dsx3IntervalEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
              "The DS3/E3 Interval Table contains various
              statistics collected by each DS3/E3 Interface over
              the previous 24 hours of operation.  The past 24
              hours are broken into 96 completed 15 minute
              intervals.  Each row in this table represents one
              such interval (identified by dsx3IntervalNumber)
              and for one specific interface (identified by
              dsx3IntervalIndex)."
       ::= { ds3 7 }

  dsx3IntervalEntry OBJECT-TYPE
       SYNTAX  Dsx3IntervalEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
              "An entry in the DS3/E3 Interval table."
       INDEX   { dsx3IntervalIndex, dsx3IntervalNumber }
       ::= { dsx3IntervalTable 1 }

  Dsx3IntervalEntry ::=
       SEQUENCE {
           dsx3IntervalIndex           InterfaceIndex,
           dsx3IntervalNumber          INTEGER,
           dsx3IntervalPESs            PerfIntervalCount,
           dsx3IntervalPSESs           PerfIntervalCount,
           dsx3IntervalSEFSs           PerfIntervalCount,
           dsx3IntervalUASs            PerfIntervalCount,
           dsx3IntervalLCVs            PerfIntervalCount,
           dsx3IntervalPCVs            PerfIntervalCount,
           dsx3IntervalLESs            PerfIntervalCount,



Nicklass                    Standards Track                    [Page 31]

RFC 3896                       DS3/E3 MIB                 September 2004


           dsx3IntervalCCVs            PerfIntervalCount,
           dsx3IntervalCESs            PerfIntervalCount,
           dsx3IntervalCSESs           PerfIntervalCount,
           dsx3IntervalValidData       TruthValue
       }

  dsx3IntervalIndex OBJECT-TYPE
       SYNTAX  InterfaceIndex
       MAX-ACCESS  read-only  -- read-only since originally an
                              -- SMIv1 index
       STATUS  current
       DESCRIPTION
              "The index value which uniquely identifies the
              DS3/E3 interface to which this entry is
              applicable.  The interface identified by a
              particular value of this index is the same
              interface as identified by the same value an
              dsx3LineIndex object instance."
       ::= { dsx3IntervalEntry 1 }

  dsx3IntervalNumber OBJECT-TYPE
       SYNTAX  INTEGER (1..96)
       MAX-ACCESS  read-only  -- read-only since originally an
                              -- SMIv1 index
       STATUS  current
       DESCRIPTION
              "A number between 1 and 96, where 1 is the most
              recently completed 15 minute interval and 96 is
              the 15 minutes interval completed 23 hours and 45
              minutes prior to interval 1."
       ::= { dsx3IntervalEntry 2 }

  dsx3IntervalPESs OBJECT-TYPE
       SYNTAX  PerfIntervalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
              "The counter associated with the number of P-bit
              Errored Seconds."
       ::= { dsx3IntervalEntry 3 }

  dsx3IntervalPSESs OBJECT-TYPE
       SYNTAX  PerfIntervalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
              "The counter associated with the number of P-bit
              Severely Errored Seconds."



Nicklass                    Standards Track                    [Page 32]

RFC 3896                       DS3/E3 MIB                 September 2004


       ::= { dsx3IntervalEntry 4 }

  dsx3IntervalSEFSs OBJECT-TYPE
       SYNTAX  PerfIntervalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
              "The counter associated with the number of
              Severely Errored Framing Seconds."
       ::= { dsx3IntervalEntry 5 }

  dsx3IntervalUASs OBJECT-TYPE
       SYNTAX  PerfIntervalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
              "The counter associated with the number of
              Unavailable Seconds.  This object may decrease if
              the occurrence of unavailable seconds occurs across
              an interval boundary."
       ::= { dsx3IntervalEntry 6 }

  dsx3IntervalLCVs OBJECT-TYPE
       SYNTAX  PerfIntervalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
              "The counter associated with the number of Line
              Coding Violations."
       ::= { dsx3IntervalEntry 7 }

  dsx3IntervalPCVs OBJECT-TYPE
       SYNTAX  PerfIntervalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
              "The counter associated with the number of P-bit
              Coding Violations."
       ::= { dsx3IntervalEntry 8 }

  dsx3IntervalLESs OBJECT-TYPE
       SYNTAX  PerfIntervalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
              "The number of Line Errored  Seconds  (BPVs  or
              illegal  zero  sequences)."
       ::= { dsx3IntervalEntry 9 }



Nicklass                    Standards Track                    [Page 33]

RFC 3896                       DS3/E3 MIB                 September 2004


   dsx3IntervalCCVs OBJECT-TYPE
        SYNTAX  PerfIntervalCount
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
               "The number of C-bit Coding Violations."
        ::= { dsx3IntervalEntry 10 }

   dsx3IntervalCESs OBJECT-TYPE
        SYNTAX  PerfIntervalCount
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
               "The number of C-bit Errored Seconds."
        ::= { dsx3IntervalEntry 11 }

   dsx3IntervalCSESs OBJECT-TYPE
        SYNTAX  PerfIntervalCount
        MAX-ACCESS  read-only
        STATUS  current
        DESCRIPTION
               "The number of C-bit Severely Errored Seconds."
        ::= { dsx3IntervalEntry 12 }

   dsx3IntervalValidData OBJECT-TYPE
        SYNTAX  TruthValue
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
               " This variable indicates if the data for this
               interval is valid."
        ::= { dsx3IntervalEntry 13 }

  -- the DS3/E3 Total

  dsx3TotalTable OBJECT-TYPE
       SYNTAX  SEQUENCE OF Dsx3TotalEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
              "The DS3/E3 Total Table contains the cumulative
              sum of the various statistics for the 24 hour
              period preceding the current interval."
       ::= { ds3 8 }

  dsx3TotalEntry OBJECT-TYPE
       SYNTAX  Dsx3TotalEntry
       MAX-ACCESS  not-accessible



Nicklass                    Standards Track                    [Page 34]

RFC 3896                       DS3/E3 MIB                 September 2004


       STATUS  current
       DESCRIPTION
              "An entry in the DS3/E3 Total table."
      INDEX   { dsx3TotalIndex }
       ::= { dsx3TotalTable 1 }

  Dsx3TotalEntry ::=
       SEQUENCE {
           dsx3TotalIndex      InterfaceIndex,
           dsx3TotalPESs       PerfTotalCount,
           dsx3TotalPSESs      PerfTotalCount,
           dsx3TotalSEFSs      PerfTotalCount,
           dsx3TotalUASs       PerfTotalCount,
           dsx3TotalLCVs       PerfTotalCount,
           dsx3TotalPCVs       PerfTotalCount,
           dsx3TotalLESs       PerfTotalCount,
           dsx3TotalCCVs       PerfTotalCount,
           dsx3TotalCESs       PerfTotalCount,
           dsx3TotalCSESs      PerfTotalCount
       }

  dsx3TotalIndex OBJECT-TYPE
       SYNTAX  InterfaceIndex
       MAX-ACCESS  read-only  -- read-only since originally an
                              -- SMIv1 index
       STATUS  current
       DESCRIPTION
              "The index value which uniquely identifies the
              DS3/E3 interface to which this entry is
              applicable.  The interface identified by a
              particular value of this index is the same
              interface as identified by the same value an
              dsx3LineIndex object instance."
       ::= { dsx3TotalEntry 1 }

  dsx3TotalPESs OBJECT-TYPE
       SYNTAX  PerfTotalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
              "The counter associated with the number of P-bit
              Errored Seconds, encountered by a DS3 interface in
              the previous 24 hour interval. Invalid 15 minute
              intervals count as 0."
       ::= { dsx3TotalEntry 2 }

  dsx3TotalPSESs OBJECT-TYPE
       SYNTAX  PerfTotalCount



Nicklass                    Standards Track                    [Page 35]

RFC 3896                       DS3/E3 MIB                 September 2004


       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
              "The counter associated with the number of P-bit
              Severely Errored Seconds, encountered by a DS3
              interface in the previous 24 hour interval.
              Invalid 15 minute intervals count as 0."
       ::= { dsx3TotalEntry 3 }

  dsx3TotalSEFSs OBJECT-TYPE
       SYNTAX  PerfTotalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
              "The counter associated with the number of
              Severely Errored Framing Seconds, encountered by a
              DS3/E3 interface in the previous 24 hour interval.
              Invalid 15 minute intervals count as 0."
       ::= { dsx3TotalEntry 4 }

  dsx3TotalUASs OBJECT-TYPE
       SYNTAX  PerfTotalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
              "The counter associated with the number of
              Unavailable Seconds, encountered by a DS3
              interface in the previous 24 hour interval.
              Invalid 15 minute intervals count as 0."
       ::= { dsx3TotalEntry 5 }

  dsx3TotalLCVs OBJECT-TYPE
       SYNTAX  PerfTotalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
              "The counter associated with the number of Line
              Coding Violations encountered by a DS3/E3
              interface in the previous 24 hour interval.
              Invalid 15 minute intervals count as 0."
       ::= { dsx3TotalEntry 6 }

  dsx3TotalPCVs OBJECT-TYPE
       SYNTAX  PerfTotalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
              "The counter associated with the number of P-bit



Nicklass                    Standards Track                    [Page 36]

RFC 3896                       DS3/E3 MIB                 September 2004


              Coding Violations, encountered by a DS3 interface
              in the previous 24 hour interval. Invalid 15
              minute intervals count as 0."
       ::= { dsx3TotalEntry 7 }

  dsx3TotalLESs OBJECT-TYPE
       SYNTAX  PerfTotalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
              "The number of Line Errored  Seconds  (BPVs  or
              illegal  zero  sequences) encountered by a DS3/E3
              interface in the previous 24 hour interval.
              Invalid 15 minute intervals count as 0."
       ::= { dsx3TotalEntry 8 }

  dsx3TotalCCVs OBJECT-TYPE
       SYNTAX  PerfTotalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
              "The number of C-bit Coding Violations encountered
              by a DS3 interface in the previous 24 hour
              interval. Invalid 15 minute intervals count as 0."
       ::= { dsx3TotalEntry 9 }

  dsx3TotalCESs OBJECT-TYPE
       SYNTAX  PerfTotalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
              "The number of C-bit Errored Seconds encountered
              by a DS3 interface in the previous 24 hour
              interval. Invalid 15 minute intervals count as 0."
       ::= { dsx3TotalEntry 10 }

  dsx3TotalCSESs OBJECT-TYPE
       SYNTAX  PerfTotalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
              "The number of C-bit Severely Errored Seconds
              encountered by a DS3 interface in the previous 24
              hour interval. Invalid 15 minute intervals count
              as 0."
       ::= { dsx3TotalEntry 11 }





Nicklass                    Standards Track                    [Page 37]

RFC 3896                       DS3/E3 MIB                 September 2004


  -- The DS3 Far End Group

  -- The DS3 Far End Group consists of four tables :
  --   DS3 Far End Configuration
  --   DS3 Far End Current
  --   DS3 Far End Interval
  --   DS3 Far End Total

  -- The DS3 Far End Configuration Table

  dsx3FarEndConfigTable OBJECT-TYPE
       SYNTAX  SEQUENCE OF Dsx3FarEndConfigEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
              "The DS3 Far End Configuration Table contains
              configuration information reported in the C-bits
              from the remote end."
       ::= { ds3 9 }

  dsx3FarEndConfigEntry OBJECT-TYPE
       SYNTAX  Dsx3FarEndConfigEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
              "An entry in the DS3 Far End Configuration table."
      INDEX   { dsx3FarEndLineIndex }
       ::= { dsx3FarEndConfigTable 1 }

  Dsx3FarEndConfigEntry ::=
       SEQUENCE {
          dsx3FarEndLineIndex          InterfaceIndex,
          dsx3FarEndEquipCode           DisplayString,
          dsx3FarEndLocationIDCode      DisplayString,
          dsx3FarEndFrameIDCode         DisplayString,
          dsx3FarEndUnitCode            DisplayString,
          dsx3FarEndFacilityIDCode      DisplayString
       }

  dsx3FarEndLineIndex OBJECT-TYPE
       SYNTAX  InterfaceIndex
       MAX-ACCESS  read-only  -- read-only since originally an
                              -- SMIv1 index
       STATUS  current
       DESCRIPTION
              "The index value which uniquely identifies the DS3
              interface to which this entry is applicable.  The
              interface identified by a particular value of this



Nicklass                    Standards Track                    [Page 38]

RFC 3896                       DS3/E3 MIB                 September 2004


              index is the same interface as identified by the
              same value an dsx3LineIndex object instance."
      ::= { dsx3FarEndConfigEntry 1 }

  dsx3FarEndEquipCode OBJECT-TYPE
       SYNTAX  DisplayString (SIZE (0..10))
       MAX-ACCESS  read-write
       STATUS  current
       DESCRIPTION
              "This is the Far End Equipment Identification code
              that describes the specific piece of equipment.
              It is sent within the Path Identification
              Message."
       ::= { dsx3FarEndConfigEntry 2 }

  dsx3FarEndLocationIDCode OBJECT-TYPE
       SYNTAX  DisplayString (SIZE (0..11))
       MAX-ACCESS  read-write
       STATUS  current
       DESCRIPTION
              "This is the Far End Location Identification code
              that describes the specific location of the
              equipment.  It is sent within the Path
              Identification Message."
       ::= { dsx3FarEndConfigEntry 3 }

  dsx3FarEndFrameIDCode OBJECT-TYPE
       SYNTAX  DisplayString (SIZE (0..10))
       MAX-ACCESS  read-write
       STATUS  current
       DESCRIPTION
              "This is the Far End Frame Identification code
              that identifies where the equipment is located
              within a building at a given location.  It is sent
              within the Path Identification Message."
       ::= { dsx3FarEndConfigEntry 4 }

  dsx3FarEndUnitCode OBJECT-TYPE
       SYNTAX  DisplayString (SIZE (0..6))
       MAX-ACCESS  read-write
       STATUS  current
       DESCRIPTION
              "This is the Far End code that identifies the
              equipment location within a bay.  It is sent
              within the Path Identification Message."
       ::= { dsx3FarEndConfigEntry 5 }

  dsx3FarEndFacilityIDCode OBJECT-TYPE



Nicklass                    Standards Track                    [Page 39]

RFC 3896                       DS3/E3 MIB                 September 2004


       SYNTAX  DisplayString (SIZE (0..38))
       MAX-ACCESS  read-write
       STATUS  current
       DESCRIPTION
              "This code identifies a specific Far End DS3 path.
              It is sent within the Path Identification
              Message."
       ::= { dsx3FarEndConfigEntry 6 }

  -- The DS3 Far End Current

  dsx3FarEndCurrentTable OBJECT-TYPE
       SYNTAX  SEQUENCE OF Dsx3FarEndCurrentEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
              "The DS3 Far End Current table contains various
              statistics being collected for the current 15
              minute interval.  The statistics are collected
              from the far end block error code within the C-
              bits."
       ::= { ds3 10 }

  dsx3FarEndCurrentEntry OBJECT-TYPE
       SYNTAX  Dsx3FarEndCurrentEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
              "An entry in the DS3 Far End Current table."
       INDEX   { dsx3FarEndCurrentIndex }
       ::= { dsx3FarEndCurrentTable 1 }

  Dsx3FarEndCurrentEntry ::=
       SEQUENCE {
           dsx3FarEndCurrentIndex        InterfaceIndex,
           dsx3FarEndTimeElapsed         INTEGER,
           dsx3FarEndValidIntervals      INTEGER,
           dsx3FarEndCurrentCESs         PerfCurrentCount,
           dsx3FarEndCurrentCSESs        PerfCurrentCount,
           dsx3FarEndCurrentCCVs         PerfCurrentCount,
           dsx3FarEndCurrentUASs         PerfCurrentCount,
           dsx3FarEndInvalidIntervals    INTEGER
      }

   dsx3FarEndCurrentIndex OBJECT-TYPE
       SYNTAX  InterfaceIndex
       MAX-ACCESS  read-only  -- read-only since originally an
                              -- SMIv1 index



Nicklass                    Standards Track                    [Page 40]

RFC 3896                       DS3/E3 MIB                 September 2004


       STATUS  current
       DESCRIPTION
              "The index value which uniquely identifies the DS3
              interface to which this entry is applicable.  The
              interface identified by a particular value of this
              index is identical to the interface identified by
              the same value of dsx3LineIndex."
       ::= { dsx3FarEndCurrentEntry 1 }

  dsx3FarEndTimeElapsed OBJECT-TYPE
       SYNTAX  INTEGER (0..899)
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
              "The number of seconds that have elapsed since the
              beginning of the far end current error-measurement
              period. If, for some reason, such as an adjustment
              in the system's time-of-day clock, the current
              interval exceeds the maximum value, the agent will
              return the maximum value."
       ::= { dsx3FarEndCurrentEntry 2 }

  dsx3FarEndValidIntervals OBJECT-TYPE
       SYNTAX  INTEGER (0..96)
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
              "The number of previous far end intervals for
              which data was collected.  The value will be 96
              unless the interface was brought online within the
              last 24 hours, in which case the value will be the
              number of complete 15 minute far end intervals
              since the interface has been online. In the case
              where the agent is a proxy, it is possible that
              some intervals are unavailable.  In this case,
              this interval is the maximum interval number for
              which data is available."
       ::= { dsx3FarEndCurrentEntry 3 }

  dsx3FarEndCurrentCESs OBJECT-TYPE
       SYNTAX  PerfCurrentCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
              "The counter associated with the number of Far End
              C-bit Errored Seconds."
       ::= { dsx3FarEndCurrentEntry 4 }




Nicklass                    Standards Track                    [Page 41]

RFC 3896                       DS3/E3 MIB                 September 2004


  dsx3FarEndCurrentCSESs OBJECT-TYPE
       SYNTAX  PerfCurrentCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
              "The counter associated with the number of Far End
              C-bit Severely Errored Seconds."
       ::= { dsx3FarEndCurrentEntry 5 }

  dsx3FarEndCurrentCCVs OBJECT-TYPE
       SYNTAX  PerfCurrentCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
              "The counter associated with the number of Far End
              C-bit Coding Violations reported via the far end
              block error count."
       ::= { dsx3FarEndCurrentEntry 6 }

  dsx3FarEndCurrentUASs OBJECT-TYPE
       SYNTAX  PerfCurrentCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
              "The counter associated with the number of Far End
              unavailable seconds."
       ::= { dsx3FarEndCurrentEntry 7 }

  dsx3FarEndInvalidIntervals OBJECT-TYPE
       SYNTAX  INTEGER (0..96)
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
              " The number of intervals in the range from 0 to
              dsx3FarEndValidIntervals for which no data is
              available.  This object will typically be zero
              except in cases where the data for some intervals
              are not available (e.g., in proxy situations)."
       ::= { dsx3FarEndCurrentEntry 8 }

  -- The DS3 Far End Interval Table

  dsx3FarEndIntervalTable OBJECT-TYPE
       SYNTAX  SEQUENCE OF Dsx3FarEndIntervalEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
              "The DS3 Far End Interval Table contains various



Nicklass                    Standards Track                    [Page 42]

RFC 3896                       DS3/E3 MIB                 September 2004


              statistics collected by each DS3 interface over
              the previous 24 hours of operation.  The past 24
              hours are broken into 96 completed 15 minute
              intervals."
       ::= { ds3 11 }

  dsx3FarEndIntervalEntry OBJECT-TYPE
       SYNTAX  Dsx3FarEndIntervalEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
              "An entry in the DS3 Far End Interval table."
       INDEX   { dsx3FarEndIntervalIndex,
                 dsx3FarEndIntervalNumber }
       ::= { dsx3FarEndIntervalTable 1 }

  Dsx3FarEndIntervalEntry ::=
       SEQUENCE {
            dsx3FarEndIntervalIndex      InterfaceIndex,
            dsx3FarEndIntervalNumber     INTEGER,
            dsx3FarEndIntervalCESs       PerfIntervalCount,
            dsx3FarEndIntervalCSESs      PerfIntervalCount,
            dsx3FarEndIntervalCCVs       PerfIntervalCount,
            dsx3FarEndIntervalUASs       PerfIntervalCount,
            dsx3FarEndIntervalValidData  TruthValue
      }

  dsx3FarEndIntervalIndex OBJECT-TYPE
       SYNTAX  InterfaceIndex
       MAX-ACCESS  read-only  -- read-only since originally an
                              -- SMIv1 index
       STATUS  current
       DESCRIPTION
              "The index value which uniquely identifies the DS3
              interface to which this entry is applicable.  The
              interface identified by a particular value of this
              index is identical to the interface identified by
              the same value of dsx3LineIndex."
       ::= { dsx3FarEndIntervalEntry 1 }

  dsx3FarEndIntervalNumber OBJECT-TYPE
      SYNTAX  INTEGER (1..96)
      MAX-ACCESS  read-only  -- read-only since originally an
                              -- SMIv1 index
      STATUS  current
      DESCRIPTION
              "A number between 1 and 96, where 1 is the most
              recently completed 15 minute interval and 96 is



Nicklass                    Standards Track                    [Page 43]

RFC 3896                       DS3/E3 MIB                 September 2004


              the 15 minutes interval completed 23 hours and 45
              minutes prior to interval 1."
      ::= { dsx3FarEndIntervalEntry 2 }

  dsx3FarEndIntervalCESs OBJECT-TYPE
      SYNTAX  PerfIntervalCount
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
              "The counter associated with the number of Far End
              C-bit Errored Seconds encountered by a DS3
              interface in one of the previous 96, individual 15
              minute, intervals. In the case where the agent is
              a proxy and data is not available, return
              noSuchInstance."
      ::= { dsx3FarEndIntervalEntry 3 }

  dsx3FarEndIntervalCSESs OBJECT-TYPE
      SYNTAX  PerfIntervalCount
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
              "The counter associated with the number of Far End
              C-bit Severely Errored Seconds."
       ::= { dsx3FarEndIntervalEntry 4 }

  dsx3FarEndIntervalCCVs OBJECT-TYPE
       SYNTAX  PerfIntervalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
              "The counter associated with the number of Far End
              C-bit Coding Violations reported via the far end
              block error count."
       ::= { dsx3FarEndIntervalEntry 5 }

  dsx3FarEndIntervalUASs OBJECT-TYPE
       SYNTAX  PerfIntervalCount
       MAX-ACCESS  read-only
       STATUS  current
       DESCRIPTION
              "The counter associated with the number of Far End
              unavailable seconds."
       ::= { dsx3FarEndIntervalEntry 6 }

  dsx3FarEndIntervalValidData OBJECT-TYPE
       SYNTAX  TruthValue
       MAX-ACCESS  read-only



Nicklass                    Standards Track                    [Page 44]

RFC 3896                       DS3/E3 MIB                 September 2004


       STATUS  current
       DESCRIPTION
              " This variable indicates if the data for this
              interval is valid."
       ::= { dsx3FarEndIntervalEntry 7 }

  -- The DS3 Far End Total

  dsx3FarEndTotalTable OBJECT-TYPE
       SYNTAX  SEQUENCE OF Dsx3FarEndTotalEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
              "The DS3 Far End Total Table contains the
              cumulative sum of the various statistics for the
              24 hour period preceding the current interval."
       ::= { ds3 12 }

  dsx3FarEndTotalEntry OBJECT-TYPE
       SYNTAX  Dsx3FarEndTotalEntry
       MAX-ACCESS  not-accessible
       STATUS  current
       DESCRIPTION
              "An entry in the DS3 Far End Total table."
       INDEX   { dsx3FarEndTotalIndex }
       ::= { dsx3FarEndTotalTable 1 }

  Dsx3FarEndTotalEntry ::=
       SEQUENCE {
           dsx3FarEndTotalIndex       InterfaceIndex,
           dsx3FarEndTotalCESs        PerfTotalCount,
           dsx3FarEndTotalCSESs       PerfTotalCount,
           dsx3FarEndTotalCCVs        PerfTotalCount,
           dsx3FarEndTotalUASs        PerfTotalCount
       }

  dsx3FarEndTotalIndex OBJECT-TYPE
      SYNTAX  InterfaceIndex
      MAX-ACCESS  read-only  -- read-only since originally an
                              -- SMIv1 index
      STATUS  current
      DESCRIPTION
              "The index value which uniquely identifies the DS3
              interface to which this entry is applicable.  The
              interface identified by a particular value of this
              index is identical to the interface identified by
              the same value of dsx3LineIndex."
      ::= { dsx3FarEndTotalEntry 1 }



Nicklass                    Standards Track                    [Page 45]

RFC 3896                       DS3/E3 MIB                 September 2004


  dsx3FarEndTotalCESs OBJECT-TYPE
      SYNTAX  PerfTotalCount
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
              "The counter associated with the number of Far End
              C-bit Errored Seconds encountered by a DS3
              interface in the previous 24 hour interval.
              Invalid 15 minute intervals count as 0."
      ::= { dsx3FarEndTotalEntry 2 }

  dsx3FarEndTotalCSESs OBJECT-TYPE
      SYNTAX  PerfTotalCount
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
              "The counter associated with the number of Far End
              C-bit Severely Errored Seconds encountered by a
              DS3 interface in the previous 24 hour interval.
              Invalid 15 minute intervals count as 0."
      ::= { dsx3FarEndTotalEntry 3 }

  dsx3FarEndTotalCCVs OBJECT-TYPE
      SYNTAX  PerfTotalCount
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
              "The counter associated with the number of Far End
              C-bit Coding Violations reported via the far end
              block error count encountered by a DS3 interface
              in the previous 24 hour interval. Invalid 15
              minute intervals count as 0."
      ::= { dsx3FarEndTotalEntry 4 }

  dsx3FarEndTotalUASs OBJECT-TYPE
      SYNTAX  PerfTotalCount
      MAX-ACCESS  read-only
      STATUS  current
      DESCRIPTION
              "The counter associated with the number of Far End
              unavailable seconds encountered by a DS3 interface
              in the previous 24 hour interval.  Invalid 15
              minute intervals count as 0."
      ::= { dsx3FarEndTotalEntry 5 }

  -- the DS3/E3 Fractional Table

  -- This table is deprecated.



Nicklass                    Standards Track                    [Page 46]

RFC 3896                       DS3/E3 MIB                 September 2004


  dsx3FracTable OBJECT-TYPE
      SYNTAX  SEQUENCE OF Dsx3FracEntry
      MAX-ACCESS  not-accessible
      STATUS  deprecated
      DESCRIPTION
              "This table is deprecated in favour of using
              ifStackTable.

              Implementation of this table was optional.  It was
              designed for those systems dividing a DS3/E3 into
              channels containing different data streams that
              are of local interest.

              The DS3/E3 fractional table identifies which
              DS3/E3 channels associated with a CSU are being
              used to support a logical interface, i.e., an
              entry in the interfaces table from the Internet-
              standard MIB.

              For example, consider a DS3 device with 4 high
              speed links carrying router traffic, a feed for
              voice, a feed for video, and a synchronous channel
              for a non-routed protocol.  We might describe the
              allocation of channels, in the dsx3FracTable, as
              follows:
              dsx3FracIfIndex.2. 1 = 3  dsx3FracIfIndex.2.15 = 4
              dsx3FracIfIndex.2. 2 = 3  dsx3FracIfIndex.2.16 = 6
              dsx3FracIfIndex.2. 3 = 3  dsx3FracIfIndex.2.17 = 6
              dsx3FracIfIndex.2. 4 = 3  dsx3FracIfIndex.2.18 = 6
              dsx3FracIfIndex.2. 5 = 3  dsx3FracIfIndex.2.19 = 6
              dsx3FracIfIndex.2. 6 = 3  dsx3FracIfIndex.2.20 = 6
              dsx3FracIfIndex.2. 7 = 4  dsx3FracIfIndex.2.21 = 6
              dsx3FracIfIndex.2. 8 = 4  dsx3FracIfIndex.2.22 = 6
              dsx3FracIfIndex.2. 9 = 4  dsx3FracIfIndex.2.23 = 6
              dsx3FracIfIndex.2.10 = 4  dsx3FracIfIndex.2.24 = 6
              dsx3FracIfIndex.2.11 = 4  dsx3FracIfIndex.2.25 = 6
              dsx3FracIfIndex.2.12 = 5  dsx3FracIfIndex.2.26 = 6
              dsx3FracIfIndex.2.13 = 5  dsx3FracIfIndex.2.27 = 6
              dsx3FracIfIndex.2.14 = 5  dsx3FracIfIndex.2.28 = 6
              For dsx3M23, dsx3 SYNTRAN, dsx3CbitParity, and
              dsx3ClearChannel  there are 28 legal channels,
              numbered 1 through 28.

              For e3Framed there are 16 legal channels, numbered
              1 through 16.  The channels (1..16) correspond
              directly to the equivalently numbered time-slots."
       ::= { ds3 13 }




Nicklass                    Standards Track                    [Page 47]

RFC 3896                       DS3/E3 MIB                 September 2004


  dsx3FracEntry OBJECT-TYPE
       SYNTAX  Dsx3FracEntry
       MAX-ACCESS  not-accessible
       STATUS  deprecated
       DESCRIPTION
                      "An entry in the DS3 Fractional table."
      INDEX   { dsx3FracIndex, dsx3FracNumber }
      ::= { dsx3FracTable 1 }

  Dsx3FracEntry ::=
       SEQUENCE {
           dsx3FracIndex     INTEGER,
           dsx3FracNumber    INTEGER,
           dsx3FracIfIndex   INTEGER
      }

  dsx3FracIndex OBJECT-TYPE
      SYNTAX  INTEGER (1..'7fffffff'h)
      MAX-ACCESS  read-only -- read-only since originally an
                                -- SMIv1 index
      STATUS  deprecated
      DESCRIPTION
              "The index value which uniquely identifies  the
              DS3  interface  to which this entry is applicable
              The interface identified by a  particular value
              of  this  index is the same interface as
              identified by the same value  an  dsx3LineIndex
              object instance."
      ::= { dsx3FracEntry 1 }

  dsx3FracNumber OBJECT-TYPE
      SYNTAX  INTEGER (1..31)
      MAX-ACCESS  read-only  -- read-only since originally an
                              -- SMIv1 index
      STATUS  deprecated
      DESCRIPTION
              "The channel number for this entry."
     ::= { dsx3FracEntry 2 }

  dsx3FracIfIndex OBJECT-TYPE
     SYNTAX  INTEGER (0..'7fffffff'h)
     MAX-ACCESS  read-write
     STATUS  deprecated
     DESCRIPTION
             "An index value that uniquely identifies an
             interface.  The interface identified by a
             particular value of this index is the same
             interface as  identified by the same value an



Nicklass                    Standards Track                    [Page 48]

RFC 3896                       DS3/E3 MIB                 September 2004


             ifIndex object instance. If no interface is
             currently using a channel, the value should be
             zero.  If a single interface occupies more  than
             one  time slot,  that ifIndex value will be found
             in multiple time slots."
     ::= { dsx3FracEntry 3 }

   -- DS3 TRAPS

  ds3Traps OBJECT IDENTIFIER ::= { ds3 15 }

  dsx3LineStatusChange NOTIFICATION-TYPE
      OBJECTS { dsx3LineStatus,
                dsx3LineStatusLastChange }
      STATUS  current
      DESCRIPTION
              "A dsx3LineStatusChange trap is sent when the
              value of an instance of dsx3LineStatus changes. It
              can be utilized by an NMS to trigger polls.  When
              the line status change results in a lower level
              line status change (i.e., ds1), then no traps for
              the lower level are sent."
       ::= { ds3Traps 0 1 }

  -- conformance information

  ds3Conformance OBJECT IDENTIFIER ::= { ds3 14 }
  ds3Groups      OBJECT IDENTIFIER ::= { ds3Conformance 1 }
  ds3Compliances OBJECT IDENTIFIER ::= { ds3Conformance 2 }

  -- compliance statements

  ds3Compliance MODULE-COMPLIANCE
      STATUS  current
      DESCRIPTION
              "The compliance statement for DS3/E3 interfaces."
      MODULE  -- this module
          MANDATORY-GROUPS { ds3NearEndConfigGroup,
                             ds3NearEndStatisticsGroup }

          GROUP       ds3FarEndGroup
          DESCRIPTION
              "Implementation of this group is optional for all
              systems that attach to a DS3 Interface.  However,
              only C-bit Parity and SYNTRAN DS3 applications
              have the capability (option) of providing this
              information."
          GROUP       ds3NearEndOptionalTrapGroup



Nicklass                    Standards Track                    [Page 49]

RFC 3896                       DS3/E3 MIB                 September 2004


          DESCRIPTION
              "Implementation of this group is optional for all
              systems that attach to a DS3 Interface.  If it is
              implemented then ds3NearEndOptionalConfigGroup
              should also be implemented."
          GROUP       ds3NearEndOptionalConfigGroup
          DESCRIPTION
              "Implementation of this group is optional for all
              systems that attach to a DS3 interface."

          OBJECT      dsx3LineType
          MIN-ACCESS  read-only
          DESCRIPTION
              "Write access for the line type is not required."

          OBJECT      dsx3LineCoding
          MIN-ACCESS  read-only
          DESCRIPTION
              "Write access for the line coding is not
              required."

          OBJECT      dsx3SendCode
          MIN-ACCESS  read-only
          DESCRIPTION
              "Write access for the send code is not required."

          OBJECT      dsx3LoopbackConfig
          MIN-ACCESS  read-only
          DESCRIPTION
              "Write access for loopbacks is not required."

          OBJECT      dsx3TransmitClockSource
          MIN-ACCESS  read-only
          DESCRIPTION
              "Write access for the transmit clock source is not
              required."

          OBJECT      dsx3LineLength
          MIN-ACCESS  read-only
          DESCRIPTION
              "Write access for the line length is not
              required."

          OBJECT      dsx3Channelization
          MIN-ACCESS  read-only
          DESCRIPTION
              "Write access for the channelization is not
              required."



Nicklass                    Standards Track                    [Page 50]

RFC 3896                       DS3/E3 MIB                 September 2004


      ::= { ds3Compliances 1 }

  -- units of conformance

  ds3NearEndConfigGroup  OBJECT-GROUP
      OBJECTS { dsx3LineIndex,
                dsx3TimeElapsed,
                dsx3ValidIntervals,
                dsx3LineType,
                dsx3LineCoding,
                dsx3SendCode,
                dsx3CircuitIdentifier,
                dsx3LoopbackConfig,
                dsx3LineStatus,
                dsx3TransmitClockSource,
                dsx3InvalidIntervals,
                dsx3LineLength,
                dsx3LoopbackStatus,
                dsx3Channelization,
                dsx3Ds1ForRemoteLoop}
      STATUS  current
      DESCRIPTION
              "A collection of objects providing configuration
              information applicable to all DS3/E3 interfaces."
      ::= { ds3Groups 1 }

  ds3NearEndStatisticsGroup OBJECT-GROUP
      OBJECTS { dsx3CurrentIndex,
                dsx3CurrentPESs,
                dsx3CurrentPSESs,
                dsx3CurrentSEFSs,
                dsx3CurrentUASs,
                dsx3CurrentLCVs,
                dsx3CurrentPCVs,
                dsx3CurrentLESs,
                dsx3CurrentCCVs,
                dsx3CurrentCESs,
                dsx3CurrentCSESs,
                dsx3IntervalIndex,
                dsx3IntervalNumber,
                dsx3IntervalPESs,
                dsx3IntervalPSESs,
                dsx3IntervalSEFSs,
                dsx3IntervalUASs,
                dsx3IntervalLCVs,
                dsx3IntervalPCVs,
                dsx3IntervalLESs,
                dsx3IntervalCCVs,



Nicklass                    Standards Track                    [Page 51]

RFC 3896                       DS3/E3 MIB                 September 2004


                dsx3IntervalCESs,
                dsx3IntervalCSESs,
                dsx3IntervalValidData,
                dsx3TotalIndex,
                dsx3TotalPESs,
                dsx3TotalPSESs,
                dsx3TotalSEFSs,
                dsx3TotalUASs,
                dsx3TotalLCVs,
                dsx3TotalPCVs,
                dsx3TotalLESs,
                dsx3TotalCCVs,
                dsx3TotalCESs,
                dsx3TotalCSESs }
      STATUS  current
      DESCRIPTION
              "A collection of objects providing statistics
              information applicable to all DS3/E3 interfaces."
      ::= { ds3Groups 2 }

  ds3FarEndGroup  OBJECT-GROUP
      OBJECTS { dsx3FarEndLineIndex,
                dsx3FarEndEquipCode,
                dsx3FarEndLocationIDCode,
                dsx3FarEndFrameIDCode,
                dsx3FarEndUnitCode,
                dsx3FarEndFacilityIDCode,
                dsx3FarEndCurrentIndex,
                dsx3FarEndTimeElapsed,
                dsx3FarEndValidIntervals,
                dsx3FarEndCurrentCESs,
                dsx3FarEndCurrentCSESs,
                dsx3FarEndCurrentCCVs,
                dsx3FarEndCurrentUASs,
                dsx3FarEndInvalidIntervals,
                dsx3FarEndIntervalIndex,
                dsx3FarEndIntervalNumber,
                dsx3FarEndIntervalCESs,
                dsx3FarEndIntervalCSESs,
                dsx3FarEndIntervalCCVs,
                dsx3FarEndIntervalUASs,
                dsx3FarEndIntervalValidData,
                dsx3FarEndTotalIndex,
                dsx3FarEndTotalCESs,
                dsx3FarEndTotalCSESs,
                dsx3FarEndTotalCCVs,
                dsx3FarEndTotalUASs }
      STATUS  current



Nicklass                    Standards Track                    [Page 52]

RFC 3896                       DS3/E3 MIB                 September 2004


      DESCRIPTION
              "A collection of objects providing remote
              configuration and statistics information
              applicable to C-bit Parity and SYNTRAN DS3
              interfaces."
      ::= { ds3Groups 3 }

  ds3DeprecatedGroup OBJECT-GROUP

      OBJECTS { dsx3IfIndex,
                dsx3FracIndex,
                dsx3FracNumber,
                dsx3FracIfIndex }
      STATUS  deprecated
      DESCRIPTION
              "A collection of obsolete objects that may be
              implemented for backwards compatibility."
      ::= { ds3Groups 4 }

  ds3NearEndOptionalConfigGroup OBJECT-GROUP
      OBJECTS { dsx3LineStatusLastChange,
                dsx3LineStatusChangeTrapEnable }

      STATUS    current
      DESCRIPTION
              "A collection of objects that may be implemented
              on DS3/E3 interfaces."
      ::= { ds3Groups 5 }

  ds3NearEndOptionalTrapGroup NOTIFICATION-GROUP
      NOTIFICATIONS { dsx3LineStatusChange }
      STATUS    current
      DESCRIPTION
              "A collection of notifications that may be
              implemented on DS3/E3 interfaces."
      ::= { ds3Groups 6 }

  END













Nicklass                    Standards Track                    [Page 53]

RFC 3896                       DS3/E3 MIB                 September 2004


4.  Appendix A - Use of dsx3IfIndex and dsx3LineIndex

  This Appendix exists to document the previous use if dsx3IfIndex and
  dsx3LineIndex and to clarify the relationship of dsx3LineIndex as
  defined in RFC 1407 with the dsx3LineIndex as defined in this
  document.

  The following shows the old and new definitions and the relationship:

  [New Definition]: "This object should be made equal to ifIndex.  The
  next paragraph describes its previous usage.  Making the object equal
  to ifIndex allows proper use of ifStackTable.

  [Old Definition]: "this object is the identifier of a DS3/E3
  Interface on a managed device.  If there is an ifEntry that is
  directly associated with this and only this DS3/E3 interface, it
  should have the same value as ifIndex.  Otherwise, number the
  dsx3LineIndices with an unique identifier following the rules of
  choosing a number that is greater than ifNumber and numbering the
  inside interfaces (e.g., equipment side) with even numbers and
  outside interfaces (e.g, network side) with odd numbers."

  When the "Old Definition" was created, it was described this way to
  allow a manager to treat the value _as if_ it were an ifIndex, i.e.,
  the value would either be:  1) an ifIndex value or 2) a value that
  was guaranteed to be different from all valid ifIndex values.

  The new definition is a subset of that definition, i.e., the value is
  always an ifIndex value.

  The following is Section 3.1 from [RFC1407]:

  Different physical configurations for the support of SNMP with DS3/E3
  equipment exist.  To accommodate these scenarios, two different
  indices for DS3/E3 interfaces are introduced in this MIB.  These
  indices are dsx3IfIndex and dsx3LineIndex.

  External interface scenario: the SNMP Agent represents all managed
  DS3/E3 lines as external interfaces (for example, an Agent residing
  on the device supporting DS3/E3 interfaces directly):











Nicklass                    Standards Track                    [Page 54]

RFC 3896                       DS3/E3 MIB                 September 2004


  For this scenario, all interfaces are assigned an integer value equal
  to ifIndex, and the following applies:

     ifIndex=dsx3IfIndex=dsx3LineIndex for all interfaces.

  The dsx3IfIndex column of the DS3/E3 Configuration table relates each
  DS3/E3 interface to its corresponding interface (ifIndex) in the
  Internet-standard MIB (MIB-II STD 17, [RFC1213]).

  External&Internal interface scenario: the SNMP Agents resides on an
  host external from the device supporting DS3/E3 interfaces (e.g., a
  router).  The Agent represents both the host and the DS3/E3 device.
  The index dsx3LineIndex is used to not only represent the DS3/E3
  interfaces external from the host/DS3/E3-device combination, but also
  the DS3/E3 interfaces connecting the host and the DS3/E3 device.  The
  index dsx3IfIndex is always equal to ifIndex.

  Example:

  A shelf full of CSUs connected to a Router.  An SNMP Agent residing
  on the router proxies for itself and the CSU.  The router has also an
  Ethernet interface:

        +-----+
  |     |     |
  |     |     |               +---------------------+
  |E    |     |  44.736 MBPS  |   ds3 M13    Line#A | ds3 C-bit Parity
  |t    |  R  |---------------+ - - - - -  - - -  - +------>
  |h    |     |               |                     |
  |e    |  O  |  44.736 MBPS  |   ds3 M13    Line#B | ds3 C-bit Parity
  |r    |     |---------------+ - - - - - - - - - - +------>
  |n    |  U  |               |                     |
  |e    |     |  44.736 MBPS  |   ds3 M13    Line#C | ds3 C-bit Parity
  |t    |  T  |---------------+ - - - -- -- - - - - +------>
  |     |     |               |                     |
  |-----|  E  |  44.736 MBPS  |   ds3 M13    Line#D | ds3 C-bit Parity
  |     |     |---------------+ -  - - - -- - - - - +------>
  |     |  R  |               |_____________________|
  |     |     |
  |     +-----+











Nicklass                    Standards Track                    [Page 55]

RFC 3896                       DS3/E3 MIB                 September 2004


  The assignment of the index values could for example be:

          ifIndex (= dsx3IfIndex)                     dsx3LineIndex

                  1                   NA                  NA (Ethernet)
                  2      Line#A   Router Side             6
                  2      Line#A   Network Side            7
                  3      Line#B   Router Side             8
                  3      Line#B   Network Side            9
                  4      Line#C   Router Side            10
                  4      Line#C   Network Side           11
                  5      Line#D   Router Side            12
                  5      Line#D   Network Side           13

  For this example, ifNumber is equal to 5.  Note the following
  description of dsx3LineIndex:  the dsx3LineIndex identifies a DS3/E3
  Interface on a managed device.  If there is an ifEntry that is
  directly associated with this and only this DS3/E3 interface, it
  should have the same value as ifIndex.  Otherwise, number the
  dsx3LineIndices with an unique identifier following the rules of
  choosing a number greater than ifNumber and numbering inside
  interfaces (e.g., equipment side) with even numbers and outside
  interfaces (e.g., network side) with odd numbers.

  If the CSU shelf is managed by itself by a local SNMP Agent, the
  situation would be:

          ifIndex (= dsx3IfIndex)                      dsx3LineIndex

                  1      Line#A     Network Side            1
                  2      Line#A     RouterSide              2
                  3      Line#B     Network Side            3
                  4      Line#B     RouterSide              4
                  5      Line#C     Network Side            5
                  6      Line#C     Router Side             6
                  7      Line#D     Network Side            7
                  8      Line#D     Router Side             8

5.  Appendix B - The delay approach to Unavialable Seconds.

  This procedure is illustrated below for a DS3 C-Bit parity
  application.  Similar rules would apply for other interfaces covered
  by this MIB.  The procedure guarantees that the statistical counters
  are correctly updated at all times, although they lag real time by 10
  seconds.  At the end of each 15 minutes interval the current interval
  counts are transferred to the most recent interval entry and each
  interval is shifted up by one position, with the oldest being
  discarded if necessary in order to make room.  The current interval



Nicklass                    Standards Track                    [Page 56]

RFC 3896                       DS3/E3 MIB                 September 2004


  counts then start over from zero.  Note, however, that the signal
  state calculation does not start afresh at each interval boundary;
  rather, signal state information is retained across interval
  boundaries.

  +----------------------------------------------------------------+
  |           READ COUNTERS & STATUS INFO FROM HARDWARE            |
  |                                                                |
  |BPV EXZ LOS     PCV CCV AIS SEF OOF LOF         FEBE  RAI       |
  +----------------------------------------------------------------+
    |   |   |       |   |   |   |   |   |            |    |
    |   |   |       |   |   |   |   |   |            |    |
    V   V   V       V   V   V   V   V   V            V    V
  +----------------------------------------------------------------+
  | ACCUM ONE-SEC STATS, CHK ERR THRESHOLDS, & UPDT SIGNAL STATE   |
  |                                                                |
  |<------------- NEAR END ---------------->| |<---- FAR END ----->|
  |                                                                |
  |LCV LES PCV CCV PES CES PSES CSES SEFS A/U CCV CES CSES SEFS A/U|
  +----------------------------------------------------------------+
    |   |   |   |   |   |    |    |    |   |   |   |    |    |   |
    |   |   |   |   |   |    |    |    |   |   |   |    |    |   |
    V   V   V   V   V   V    V    V    V   |   V   V    V    V   |
  +--------------------------------------+ | +-----------------+ |
  |            ONE-SEC DELAY             | | | ONE-SEC DELAY   | |
  |              (1 OF 10)               | | |   (1 OF 10)     | |
  +--------------------------------------+ | +-----------------+ |
    |   |   |   |   |   |    |    |    |   |   |   |    |    |   |
    /   /   /   /   /   /    /    /    /   /   /   /    /    /   /
    |   |   |   |   |   |    |    |    |   |   |   |    |    |   |
    V   V   V   V   V   V    V    V    V   |   V   V    V    V   |
  +--------------------------------------+ | +-----------------+ |
  |            ONE-SEC DELAY             | | | ONE-SEC DELAY   | |
  |             (10 OF 10)               | | |  (10 OF 10)     | |
  +--------------------------------------+ | +-----------------+ |
    |   |   |   |   |   |    |    |    |   |   |   |    |    |   |
    |   |   |   |   |   |    |    |    |   |   |   |    |    |   |
    V   V   V   V   V   V    V    V    V   V   V   V    V    V   V
  +----------------------------------------------------------------+
  |               UPDATE STATISTICS COUNTERS                       |
  |                                                                |
  |<------------- NEAR END ---------------->| |<---- FAR END ----->|
  |                                                                |
  |LCV LES PCV CCV PES CES PSES CSES SEFS UAS CCV CES CSES SEFS UAS|
  +----------------------------------------------------------------+

  Note that if such a procedure is adopted there is no current interval
  data for the first ten seconds after a system comes up.



Nicklass                    Standards Track                    [Page 57]

RFC 3896                       DS3/E3 MIB                 September 2004


  noSuchInstance must be returned if a management station attempts to
  access the current interval counters during this time.

  It is an implementation-specific matter whether an agent assumes that
  the initial state of the interface is available or unavailable.

6.  Acknowledgments

  This document was produced by the AToM MIB Working Group.  The Editor
  would like to dedicate a special thanks to C. Mike Heard for
  providing a top notch doctor review and many helpful suggestions, and
  to acknowledge D. Fowler, Editor of RFC 2496, T. Cox and K. Tesink
  Editors of RFC 1407.

7.  References

7.1.  Normative References

  [RFC2578]          McCloghrie, K., Perkins, D., and J. Schoenwaelder,
                     "Structure of Management Information Version 2
                     (SMIv2)", STD 58, RFC 2578, April 1999.

  [RFC2579]          McCloghrie, K., Perkins, D., and J. Schoenwaelder,
                     "Textual Conventions for SMIv2", STD 58, RFC 2579,
                     April 1999.

  [RFC2580]          McCloghrie, K., Perkins, D., and J. Schoenwaelder,
                     "Conformance Statements for SMIv2", STD 58, RFC
                     2580, April 1999.

  [RFC2863]          McCloghrie, K. and F. Kastenholz, "The Interfaces
                     Group MIB", RFC 2863, June 2000.

  [ANSI-T1.102]      American National Standard for telecommunications
                     - digital hierarchy - electrical interfaces, ANSI
                     T1.102-1987.

  [ANSI-T1.107]      American National Standard for telecommunications
                     - digital hierarchy - formats specification, ANSI
                     T1.107- 1988.

  [ANSI-T1.107a]     ANSI T1.107a-1990.

  [ANSI-T1.404]      American National Standard for telecommunications
                     - Carrier-to-Customer Installation - DS3 Metallic
                     Interface, ANSI T1.404-1989.





Nicklass                    Standards Track                    [Page 58]

RFC 3896                       DS3/E3 MIB                 September 2004


  [ANSI-T1.231]      American National Standard for Telecommunications
                     -- Layer 1 In- Service Digital Transmission
                     Performance Monitoring T1.231, Sept 1993.

  [CCITT-G.751]      CCITT - Digital Multiplex Equipment Operating at
                     the Third Order Bit Rate of 34 368 Kbit/s and the
                     Forth Order Bit Rate of 139 264 Kbit/s and Using
                     Positive Justification, G.751

  [ETSI-T/NA(91)18]  European Telecommunications Standards Institute --
                     ETS "34M" -- Metropolitan Area Network Physical
                     Convergence Layer Procedure for 34.368 Megabits
                     per Second, T/NA(91)18, May 1991.

  [RFC3593]          Tesink, K., "Textual Conventions for MIB Modules
                     Using Performance History Based on 15 Minute
                     Intervals", RFC 3593, September 2003.

  [ITU-T-M.1400]     ITU-T M.1400: Designation For Interconnections
                     Among Network Operators, October 2001.

7.2.  Informative References

  [RFC1213]          McCloghrie, K. and M. Rose, "Management
                     Information Base for Network Management of
                     TCP/IP-based internets:MIB-II", STD 17, RFC 1213,
                     March 1991.

  [RFC1407]          Cox, T. and K. Tesink, "Definitions of Managed
                     Objects for the DS3/E3 Interface Type", RFC 1407,
                     January 1993.

  [RFC2496]          Fowler, D., "Definitions of Managed Object for the
                     DS3/E3 Interface Type", RFC 2496, January 1999.

  [RFC3895]          Nicklass, O., Ed., "Definitions of Managed Objects
                     for the DS1, E1, DS2, and E2 Interface Types", RFC
                     3895, September 2004.

  [RFC3592]          Tesink, K., "Definitions of Managed Objects for
                     the Synchronous Optical Network/Synchronous
                     Digital Hierarchy (SONET/SDH) Interface Type", RFC
                     3592, September 2003.

  [RFC2494]          Fowler, D., "Definitions of Managed Objects for
                     the DS0 and DS0 Bundle Interface Type", RFC 2494,
                     January 1999.




Nicklass                    Standards Track                    [Page 59]

RFC 3896                       DS3/E3 MIB                 September 2004


  [RFC3410]          Case, J., Mundy, R., Partain, D., and B. Stewart,
                     "Introduction and Applicability Statements for
                     Internet-Standard Management Framework", RFC 3410,
                     December 2002.

8.  Security Considerations

  There are a number of management objects defined in this MIB module
  with a MAX-ACCESS clause of read-write.  Such objects may be
  considered sensitive or vulnerable in some network environments.  The
  support for SET operations in a non-secure environment without proper
  protection can have a negative effect on network operations.  The
  specific the objects and their sensitivities/vulnerabilities are as
  follows.

  Setting the following objects to incorrect values may result in
  traffic interruptions:

     dsx3LineType
     dsx3LineCoding
     dsx3SendCode
     dsx3LoopbackConfig
     dsx3TransmitClockSource
     dsx3LineLength
     dsx3Channelization
     dsx3Ds1ForRemoteLoop

  In the case of dsx3LineType, for example, both ends of a DS3/E3 must
  have the same value in order for traffic to flow.  In the case of
  dsx3SendCode and dsx3LoopbackConfig, for another example, traffic may
  stop transmitting when particular loopbacks are applied.

  Setting the following objects to an incorrect value will result in
  the remote end receiving an incorrect Path Identification message,
  which may result in a connectivity inconsistency:

     dsx3FarEndEquipCode
     dsx3FarEndLocationIDCode
     dsx3FarEndFrameIDCode
     dsx3FarEndUnitCode
     dsx3FarEndFacilityIDCode










Nicklass                    Standards Track                    [Page 60]

RFC 3896                       DS3/E3 MIB                 September 2004


  Setting the following object to an incorrect value will not harm the
  traffic, but it may cause a circuit to be mis-identified and thereby
  create difficulties for service personnel when attempting to
  troubleshoot a problem:

     dsx3CircuitIdentifier

  Setting the following object can cause an increase in the number of
  traps received by the network management station:

     dsx3LineStatusChangeTrapEnable

  The readable objects in this MIB module (i.e., the objects with a
  MAX-ACCESS other than not-accessible) may be considered sensitive in
  some environments since, collectively, they provide extensive
  information about the performance of interfaces in DS3/E3 equipment
  or networks and can reveal some aspects of their configuration.  In
  such environments it is important to control even GET and NOTIFY
  access to these objects and possibly to encrypt the values of these
  objects when sending them over the network via SNMP.

  SNMP versions prior to SNMPv3 did not include adequate security.
  Even if the network itself is secure (for example by using IPSec),
  even then, there is no control as to who on the secure network is
  allowed to access and GET/SET (read/change/create/delete) the objects
  in this MIB module.

  It is RECOMMENDED that implementers consider the security features as
  provided by the SNMPv3 framework (see [RFC3410], section 8),
  including full support for the SNMPv3 cryptographic mechanisms (for
  authentication and privacy).

  Further, deployment of SNMP versions prior to SNMPv3 is NOT
  RECOMMENDED.  Instead, it is RECOMMENDED to deploy SNMPv3 and to
  enable cryptographic security.  It is then a customer/operator
  responsibility to ensure that the SNMP entity giving access to an
  instance of this MIB module is properly configured to give access to
  the objects only to those principals (users) that have legitimate
  rights to indeed GET or SET (change/create/delete) them.












Nicklass                    Standards Track                    [Page 61]

RFC 3896                       DS3/E3 MIB                 September 2004


9.  Author's Address

  Orly Nicklass (editor)
  RAD Data Communications, Ltd.
  Ziv Tower, 24 Roul Walenberg
  Tel Aviv, Israel, 69719

  Phone: 9723-765-9969
  EMail: [email protected]










































Nicklass                    Standards Track                    [Page 62]

RFC 3896                       DS3/E3 MIB                 September 2004


10.  Full Copyright Statement

  Copyright (C) The Internet Society (2004).

  This document is subject to the rights, licenses and restrictions
  contained in BCP 78, and except as set forth therein, the authors
  retain all their rights.

  This document and the information contained herein are provided on an
  "AS IS" basis and THE CONTRIBUTOR, THE ORGANIZATION HE/S HE
  REPRESENTS OR IS SPONSORED BY (IF ANY), THE INTERNET SOCIETY AND THE
  INTERNET ENGINEERING TASK FORCE DISCLAIM ALL WARRANTIES, EXPRESS OR
  IMPLIED, INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF
  THE INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED
  WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

Intellectual Property

  The IETF takes no position regarding the validity or scope of any
  Intellectual Property Rights or other rights that might be claimed to
  pertain to the implementation or use of the technology described in
  this document or the extent to which any license under such rights
  might or might not be available; nor does it represent that it has
  made any independent effort to identify any such rights.  Information
  on the IETF's procedures with respect to rights in IETF Documents can
  be found in BCP 78 and BCP 79.

  Copies of IPR disclosures made to the IETF Secretariat and any
  assurances of licenses to be made available, or the result of an
  attempt made to obtain a general license or permission for the use of
  such proprietary rights by implementers or users of this
  specification can be obtained from the IETF on-line IPR repository at
  http://www.ietf.org/ipr.

  The IETF invites any interested party to bring to its attention any
  copyrights, patents or patent applications, or other proprietary
  rights that may cover technology that may be required to implement
  this standard.  Please address the information to the IETF at ietf-
  [email protected].

Acknowledgement

  Funding for the RFC Editor function is currently provided by the
  Internet Society.







Nicklass                    Standards Track                    [Page 63]