Internet Engineering Task Force (IETF)                    P. Aitken, Ed.
Request for Comments: 8038                                       Brocade
Category: Standards Track                                      B. Claise
ISSN: 2070-1721                                      Cisco Systems, Inc.
                                                                 S. B S
                                                    Mojo Networks, Inc.
                                                            C. McDowall
                                                                Brocade
                                                       J. Schoenwaelder
                                               Jacobs University Bremen
                                                               May 2017


                       Exporting MIB Variables
        Using the IP Flow Information Export (IPFIX) Protocol

Abstract

  This document specifies a way to complement IP Flow Information
  Export (IPFIX) Data Records with Management Information Base (MIB)
  objects, avoiding the need to define new IPFIX Information Elements
  for existing MIB objects that are already fully specified.

  Two IPFIX Options Templates, as well as a method for creating IPFIX
  Options Templates that are used to export the extra data required to
  fully describe Simple Network Management Protocol (SNMP) MIB objects
  in IPFIX, are specified herein.

Status of This Memo

  This is an Internet Standards Track document.

  This document is a product of the Internet Engineering Task Force
  (IETF).  It represents the consensus of the IETF community.  It has
  received public review and has been approved for publication by the
  Internet Engineering Steering Group (IESG).  Further information on
  Internet Standards is available in Section 2 of RFC 7841.

  Information about the current status of this document, any errata,
  and how to provide feedback on it may be obtained at
  http://www.rfc-editor.org/info/rfc8038.










Aitken, et al.               Standards Track                    [Page 1]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


Copyright Notice

  Copyright (c) 2017 IETF Trust and the persons identified as the
  document authors.  All rights reserved.

  This document is subject to BCP 78 and the IETF Trust's Legal
  Provisions Relating to IETF Documents
  (http://trustee.ietf.org/license-info) in effect on the date of
  publication of this document.  Please review these documents
  carefully, as they describe your rights and restrictions with respect
  to this document.  Code Components extracted from this document must
  include Simplified BSD License text as described in Section 4.e of
  the Trust Legal Provisions and are provided without warranty as
  described in the Simplified BSD License.

Table of Contents

  1. Introduction ....................................................4
  2. Motivation ......................................................5
  3. Terminology .....................................................7
  4. High-Level Solution Overview ....................................8
  5. MIB Object Value Information Elements and the MIB Field
     Options Template ...............................................10
     5.1. MIB Field Options Architecture ............................11
     5.2. IPFIX and MIB Data Model ..................................13
     5.3. MIB Field Options - Specifications and Required Fields ....15
          5.3.1. MIB Field Options Template .........................16
          5.3.2. MIB Type Options Template ..........................16
     5.4. MIB Field Options Template Formats ........................17
          5.4.1. Data Template Containing a mibObjectValue Field ....17
          5.4.2. MIB Field Options Template .........................19
          5.4.3. MIB Field Options Data Records .....................20
          5.4.4. Options Template Containing a
                 mibObjectValue Field ...............................21
          5.4.5. MIB Field Options Template with Semantics Fields ...23
          5.4.6. MIB Field Options Template with Extra MIB
                 Object Details .....................................24
     5.5. Use of Field Order in the MIB Field Options Template ......27
     5.6. Identifying the SNMP Context ..............................27
     5.7. Template Management .......................................28
          5.7.1. Large Messages .....................................28
          5.7.2. Template Withdrawal and Reuse ......................29









Aitken, et al.               Standards Track                    [Page 2]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


     5.8. Exporting Conceptual Rows and Tables ......................29
          5.8.1. Exporting Conceptual Rows - Indexing ...............30
          5.8.2. Exporting Conceptual Rows - mibObjectValueRow ......30
          5.8.3. Exporting Conceptual Rows - AUGMENTS ...............36
          5.8.4. Exporting Conceptual Tables - mibObjectValueTable ..37
          5.8.5. Exporting Columnar Objects: Using
                 mibIndexIndicator ..................................38
  6. Example Use Cases ..............................................39
     6.1. Non-columnar MIB Object: Established TCP Connections ......39
     6.2. Enterprise-Specific MIB Object: Detailing CPU Load
          History ...................................................42
     6.3. Exporting a Conceptual Row: The OSPF Neighbor Row .........45
     6.4. Exporting Augmented Conceptual Row: Mapping IF-MIB
          ID to Name ................................................49
     6.5. Exporting a Columnar Object: ipIfStatsInForwDatagrams .....55
     6.6. Exporting a Columnar Object Indexed by Information
          Elements: ifOutQLen .......................................58
     6.7. Exporting with Multiple Contexts: The OSPF
          Neighbor Row Revisited ....................................62
  7. Configuration Considerations ...................................65
  8. The Collecting Process's Side ..................................66
  9. Applicability ..................................................66
  10. Security Considerations .......................................67
  11. IANA Considerations ...........................................68
     11.1. New IPFIX Semantics ......................................68
          11.1.1. snmpCounter .......................................68
          11.1.2. snmpGauge .........................................68
     11.2. New IPFIX Information Elements ...........................69
          11.2.1. New MIB Object Value Information Elements .........69
          11.2.2. New MIB Field Options Information Elements ........75
          11.2.3. New MIB Type Information Elements .................79
  12. References ....................................................81
     12.1. Normative References .....................................81
     12.2. Informative References ...................................82
  Acknowledgments ...................................................84
  Authors' Addresses ................................................84















Aitken, et al.               Standards Track                    [Page 3]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


1.  Introduction

  There is growing interest in using IP Flow Information Export (IPFIX)
  as a push mechanism for exporting management information.  Using a
  push protocol such as IPFIX instead of a polling protocol like SNMP
  is especially interesting in situations where large chunks of
  repetitive data need to be exported periodically.

  While initially targeted at different problems, there is a large
  parallel between the information transported via IPFIX and SNMP.
  Furthermore, certain Management Information Base (MIB) objects are
  highly relevant to Flows as they are understood today.  For example,
  in the IPFIX Information Model [IANA-IPFIX], Information Elements
  coming from the SNMP world have already been specified, e.g.,
  ingressInterface and egressInterface both refer to the ifIndex object
  as defined in [RFC2863].

  In particular, the Management Information Base was designed as a
  separate system of definitions; this opens up the possibility of
  exporting objects defined via the MIB over other protocols.

  Rather than mapping existing MIB objects to IPFIX Information
  Elements on a case-by-case basis, it would be advantageous to enable
  the export of any existing or future MIB objects as part of an IPFIX
  Data Record.  This way, the duplication of Data Models [RFC3444],
  both as SMIv2 MIB objects and IPFIX Information Elements, out of the
  same Information Model [RFC3444] would be avoided.

  Therefore, the primary goals of this document are:

  o  to specify a way to complement IPFIX Data Records with MIB
     objects;

  o  to avoid the need to define new IPFIX Information Elements for
     existing MIB objects that are already fully specified;

  o  to allow the correlation of SNMP and IPFIX sourced data by
     exporting them together; and

  o  to allow SNMP push data from SNMP-only devices to be more easily
     integrated into IPFIX-based collection infrastructures.










Aitken, et al.               Standards Track                    [Page 4]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


2.  Motivation

  The intended scope of this work is the addition of MIB variable(s) to
  IPFIX Information Elements in Data Records, in order to complement
  the Data Records with useful and already-standardized information.
  Special consideration is given to the case of an existing
  Template Record that needs to be augmented with some MIB variables
  whose index is already present in the Template Record as an IPFIX
  Information Element -- for example, a 7-tuple Data Record containing
  the ingressInterface Information Element, which needs to be augmented
  by interface counters [RFC2863] that are indexed by the respective
  ingressInterface values already contained in the Data Records.  See
  Section 3 for terminology definitions.

  Many Data Records contain the ingressInterface and/or the
  egressInterface Information Elements.  These Information Elements
  carry an ifIndex value, a MIB object defined in [RFC2863].  In order
  to retrieve additional information about the identified interface, a
  Collector could simply poll relevant objects from the device running
  the Exporter via SNMP.  However, that approach has several problems:

  o  It requires implementing a mediation function between two Data
     Models, i.e., MIB objects and IPFIX Information Elements.

  o  Confirming the validity of simple mappings (e.g., ifIndex to
     ifName) requires either checking on a regular basis that the
     Exporter's network management system did not reload or imposing
     ifIndex persistence across an Exporter's reload.

  o  Synchronization problems occur because counters carried in
     Data Records and counters carried in SNMP messages are retrieved
     from the Exporter at different points in time and thus cannot be
     correlated.  In the best case, assuming very tight integration of
     an IPFIX Collector with an SNMP polling engine, SNMP data is
     retrieved shortly after Data Records have been received, which
     implies a delay of the sum of the active or idle timeouts (if not
     null) plus the time to export the Data Record to the Collector.
     If, however, the SNMP data is retrieved by a generic Network
     Management Station (NMS) polling interface statistics, then the
     time lag between IPFIX counters and SNMP counters can be
     significantly higher.  See [RFC5102] for details regarding active
     and idle timeouts.

  This document does not specify how to carry SNMP notifications in
  IPFIX, even if the specifications in this document could potentially
  allow this.





Aitken, et al.               Standards Track                    [Page 5]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


  Since IPFIX is a push mechanism, initiated from the Exporter with no
  acknowledgment method, this specification does not provide the
  ability to execute configuration changes.

  The Distributed Management Expression MIB [RFC2982], which is a
  mechanism to create new MIB variables based on the content of
  existing ones, could also be advantageous in the context of this
  specification.  Indeed, newly created MIB objects (for example, the
  link utilization MIB variable), created with the Distributed
  Management Expression MIB [RFC2982], could nicely complement
  Data Records.

  Another advantage of exporting MIB objects via IPFIX is that IPFIX
  would benefit from an extended series of types to be exported.  The
  simple and application-wide data types specified in SMIv2 [RFC2578],
  along with new textual conventions, can be exported within IPFIX and
  then decoded in the Collector.  However, since a textual convention
  can contain almost any name, this document does not extend the
  existing "IPFIX Information Elements" subregistry [IANA-IPFIX] that
  contains informationElementDataType.

  The overall architectural model is depicted in Figure 1.  The IPFIX
  Exporter accesses the device's instrumentation, which follows the
  specifications contained in MIB modules.  Other management
  interfaces, such as the Network Configuration Protocol (NETCONF) or
  the device's Command Line Interface (CLI), may provide access to the
  same instrumentation.

               +------+  +-------+  +.........+  +.....+
               | SNMP |  | IPFIX |  : NETCONF :  : CLI :
               +------+  +-------+  +.........+  +.....+
                   |         |           |          |
             +--------------------------------------------+
             | Instrumentation (specified in MIB modules) |
             +--------------------------------------------+

                      Figure 1: Architectural Model














Aitken, et al.               Standards Track                    [Page 6]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


3.  Terminology

  IPFIX-specific terminology (Information Element, Template,
  Template Record, Options Template Record, Template Set, Collector,
  Exporter, Data Record, Transport Session, Exporting Process,
  Collecting Process, etc.) used in this document is defined in
  Section 2 of [RFC7011].  As in [RFC7011], these IPFIX-specific terms
  have the first letter of a word capitalized.

  This document prefers the more generic term "Data Record" (as opposed
  to "Flow Record") in relation to the export of MIB objects.

  Object Identifier (MIB OID)

     An Object Identifier value is an ordered list of non-negative
     numbers.  For SMIv2, each number in the list is referred to as a
     sub-identifier.  There are at most 128 sub-identifiers in a value,
     and each sub-identifier has a maximum value of 2^32 - 1
     (4294967295 decimal).  See [RFC2578], Section 3.5.

  MIB Object Identifier Information Element

     An IPFIX Information Element ("mibObjectIdentifier") that denotes
     that a MIB Object Identifier (MIB OID) is exported in the
     (Options) Data Record.  See Section 11.2.2.1.

  SMIv2 Terminology

     The key words "MIB module", "MIB object", "INDEX", "AUGMENTS",
     "textual convention", "columnar object", "conceptual row", and
     "conceptual table" in this document are to be interpreted as
     described in SMIv2 [RFC2578].

  SMIv2 SYNTAX

     The SYNTAX key words "INTEGER", "Integer32", "OCTET STRING",
     "OBJECT IDENTIFIER", "BITS", "IpAddress", "Counter32", "Gauge32",
     "TimeTicks", "Opaque", "Counter64", "Unsigned32", "SEQUENCE", and
     "SEQUENCE OF" in this document are to be interpreted as described
     in SMIv2 [RFC2578].

  SNMP Context Terminology

     The key words "snmpEngineID", "contextEngineID", and "contextName"
     in this document are to be interpreted as described in [RFC3411].






Aitken, et al.               Standards Track                    [Page 7]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


  mibObjectValue Information Elements

     "mibObjectValue Information Elements" refers to any and all of the
     mibObjectValue Information Elements generically.  Any restriction
     or requirement in this document that refers to "mibObjectValue"
     applies to the following Information Elements as defined in
     Section 11.2.1: mibObjectValueInteger, mibObjectValueOctetString,
     mibObjectValueOID, mibObjectValueBits, mibObjectValueIPAddress,
     mibObjectValueCounter, mibObjectValueGauge,
     mibObjectValueTimeTicks, mibObjectValueUnsigned,
     mibObjectValueTable, and mibObjectValueRow.

  Abstract Data Type

     Abstract Data Types for IPFIX are defined in Section 3.1 of
     [RFC7012].  This specification uses the Abstract Data Types
     "unsigned8", "unsigned32", "unsigned64", "signed32", "octetArray",
     "string", "ipv4Address", and "subTemplateList".

  IE

     Used as shorthand for "Information Element" [RFC7011] in the
     figures.

  The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
  "SHOULD", "SHOULD NOT", "RECOMMENDED", "NOT RECOMMENDED", "MAY", and
  "OPTIONAL" in this document are to be interpreted as described in
  [RFC2119].

4.  High-Level Solution Overview

  This document specifies a method for creating IPFIX Options Templates
  that are used to export the extra data required to describe MIB
  variables (see Section 5.1).

  This allows IPFIX Templates to contain any combination of fields
  defined by traditional IPFIX Information Element(s) and/or MIB Object
  Identifier(s).  The MIB Object Identifiers can reference either
  non-columnar or columnar MIB object(s).  Enterprise-specific MIB
  Object Identifiers are also supported.

  This document also defines two standard IPFIX Options Templates (see
  Section 5.3) that are used as part of the mechanism to export MIB
  object metadata:

  o  MIB Field Options Template (Section 5.3.1)

  o  MIB Type Options Template (Section 5.3.2)



Aitken, et al.               Standards Track                    [Page 8]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


  This document defines three classes of new IPFIX Information
  Elements.  These are used to export values from the MIB, export
  required Object Identifier information, and optionally export type
  data from a MIB module:

  o  MIB Object Value Information Elements (Section 11.2.1)

  o  MIB Field Options Information Elements (Section 11.2.2)

  o  MIB Type Information Elements (Section 11.2.3)

  Additionally, this document defines two new IPFIX semantics that are
  required for the new Information Elements:

  o  snmpCounter (Section 11.1.1)

  o  snmpGauge (Section 11.1.2)

  Two common types defined in SMIv2 are conceptual rows and conceptual
  tables.  It is desirable that exporting a complete or partial
  conceptual row be simple and efficient.  This is accomplished by
  using IPFIX Structured Data [RFC6313] to reduce repetition of Object
  Identifier and indexing data.

  To allow the use of individual columnar objects that make up a
  conceptual row, a method is also specified to explain that a MIB
  object is indexed by other fields in the same Data Flow.  For an
  individually indexed mibObjectValue, the index fields are sent in the
  same way as any of the other fields in the same Data Record and may
  be mibObjectValue Information Element(s) or other existing
  Information Element(s).

  Also, in some cases Exporters may not want (or be able) to export the
  full information on how the MIB objects being exported are indexed.
  This may be because the MIB object is being used purely as type
  information or the Exporting Process may not have knowledge of the
  indexing required.  Therefore, providing index information for
  columnar objects is optional.













Aitken, et al.               Standards Track                    [Page 9]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


5.  MIB Object Value Information Elements and the MIB Field Options
   Template

  This document defines new mibObjectValue Information Elements (in
  Section 11.2.1).  These are used to export MIB objects as part of
  standard IPFIX Templates.  The mibObjectValue Information Elements
  contain the actual data values.

  The Metering Process or Exporting Process may extract the data values
  for mibObjectValue Information Elements from a Process that resides
  on the same device or may capture or create the data required to
  match the definition of the MIB object.  In particular, exporting a
  value of a MIB object defined in a certain MIB module does not imply
  that the SNMP process on the device supports that MIB module.

  The main issue that arises from exporting values of MIB objects in
  IPFIX is that MIB Object Identifiers do not fit into the standard
  IPFIX Template format [RFC7011], as this only provides a 16-bit
  Information Element identifier.

  The values of a MIB object could be exported using a MIB-specific
  Information Element, without providing any Object Identifiers.
  However, without exporting the actual MIB OID, the full type of the
  data would be unknown, and every field containing MIB object data
  would appear identical.  Without knowing which OID the contents of a
  field map to, the data would be incomprehensible to a Collector.

  For the values in the mibObjectValue Information Elements to be
  understandable, more meta-information about the mibObjectValue
  Information Elements must be sent as part of the IPFIX export.  The
  required minimum information to understand each field that is being
  exported is provided in Section 5.3.1.

  One approach to this problem would be to extend the IPFIX standard to
  allow extended Field Specifiers so that metadata about fields can be
  included in Data Templates.  This would, however, require a new
  version of the IPFIX standard that may not be backward compatible.
  However, future versions of IPFIX may export the required MIB
  metadata as part of newly defined IPFIX Set versions.

  This document defines a MIB Field Options Template to export the
  extra meta-information required for mibObjectValue Information
  Elements.  This is a standard IPFIX Options Template Set that
  includes a minimum set of required fields (see Section 5.3.1) and may
  include extra fields to provide more meta-information about one of
  the mibObjectValue Information Elements.





Aitken, et al.               Standards Track                   [Page 10]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


  The MIB Field Options export tells the Collecting Process the OID for
  the MIB object type definition for the following (Template, field).

5.1.  MIB Field Options Architecture

  Four IPFIX Sets are used together to export a Flow that contains
  mibObjectValue Information Elements.  These are:

  1.  A Template Set that includes the mibObjectValue Information
      Element.

         The Template Set informs the Collector that a MIB object value
         of length N will be exported.  This Set may also be an Options
         Template Set.

  2.  A MIB Field Options Template Set.

         The MIB Field Options Template describes which metadata will
         be sent for each mibObjectValue Information Element being
         exported.

  3.  A MIB Field Options Data Set.

         The MIB Field Options Data Set includes the metadata for each
         MIB object (i.e., the mibObjectIdentifier or
         mibSubIdentifier).  The metadata about the mibObjectValue
         Information Elements only needs to be resent as per normal
         Template refreshes or resends.

  4.  A Data Set.

         The Data Set contains only the actual data extracted from the
         MIB or described by the MIB module.


















Aitken, et al.               Standards Track                   [Page 11]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


  Figure 2 shows the IPFIX Message structure for a MIB field in a
  Template Set.

        +-------------------------------------------------------+
        | IPFIX Message Header                                  |
        +-------------------------------------------------------+
        | Template Set         (A)                              |
        +-------------------------------------------------------+
        | Options Template Set (B) (MIB Field Options Template) |
        +-------------------------------------------------------+
        | Data Set             (B) (MIB Field Options Data)     |
        +-------------------------------------------------------+
        | Data Set             (A)                              |
        +-------------------------------------------------------+

   Figure 2: IPFIX Message Structure for a MIB Field in a Template Set

  The MIB Field Options Template defines MIB Field Options
  Data Records.  The MIB Field Options Data Records annotate the Data
  Template with mibObjectValue metadata.  Together, the Data Template
  and MIB Field Options Data Records define the Data Records that will
  be exported.

  The Data Records (A) have a dependency on the two Templates and the
  MIB Field Options Data Records.

  More Data Sets that use the same mibObjectValue Information Element
  can then be sent in subsequent packets.























Aitken, et al.               Standards Track                   [Page 12]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


  Figure 3 shows the relationships between the Sets discussed above.

                                       +------------------------------+
                                       |MIB Field Options Template (B)|
                                       +------------------------------+
                                       |(templateId, elementIndex)    |
                                       +------------------------------+
                                       |        mibOID                |
                                       +------------------------------+
                                                    |
                                                    | Defines
                                                    V
   +------------------------+              +--------------------------+
   |    Data Template (A)   |              |MIB Field Options Data (B)|
   +------------------------+              +--------------------------+
   |Field 0 - regular IE    |              |                          |
   +------------------------+              +--------------------------+
   |Field 1-mibObjectValue  | <----------- | (X,1) = OID              |
   +------------------------+   Annotates  +--------------------------+
   |Field 2-mibObjectValue  | <----------- | (X,2) = OID              |
   +------------------------+              +--------------------------+
               |                                    |
               |------------------------------------/
               |
               | Defines
               |
               V
   +------------------------+
   |    Data Records (A)    |
   |------------------------|
   | Field 0 data           |
   +------------------------+
   | Field 1 data           |
   +------------------------+
   | Field 2 data           |
   +------------------------+

                  Figure 3: Relationships between Sets

5.2.  IPFIX and MIB Data Model

  [RFC2578], Section 7.1 specifies that the SYNTAX clause for a MIB
  object defines the abstract data structure of an object and what it
  must contain:

  "The data structure must be one of the following: a base type, BITS,
  or a textual convention.  (SEQUENCE OF and SEQUENCE are also possible
  for conceptual tables, see section 7.1.12)."



Aitken, et al.               Standards Track                   [Page 13]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


  For each of the SYNTAX clause options, this document specifies
  exactly which mibObjectValue Information Element to use.

  If a MIB object to be exported is a textual convention, the
  definition of the textual convention must be consulted and the SYNTAX
  clause used to determine the correct base type.  This may recurse if
  the textual convention is defined in terms of another textual
  convention, but this should end at a base type.

  If the SYNTAX clause contains a textual convention or sub-typing
  (e.g., integerSubType, octetStringSubType) [RFC2578], the
  mibObjectSyntax Information Element SHOULD be used to export this
  detail to the Collecting Process.

  The options for the SYNTAX clause are then mapped as follows:

  +-------------+-------------------+---------------------------------+
  | Section in  | SYNTAX            | mibObjectValue Information      |
  | RFC 2578    |                   | Element                         |
  +-------------+-------------------+---------------------------------+
  | 7.1.1       | INTEGER/Integer32 | mibObjectValueInteger           |
  | 7.1.2       | OCTET STRING      | mibObjectValueOctetString       |
  | 7.1.3       | OBJECT IDENTIFIER | mibObjectValueOID               |
  | 7.1.4       | BITS              | mibObjectValueBits              |
  | 7.1.5       | IpAddress         | mibObjectValueIPAddress         |
  | 7.1.6       | Counter32         | mibObjectValueCounter           |
  | 7.1.7       | Gauge32           | mibObjectValueGauge             |
  | 7.1.8       | TimeTicks         | mibObjectValueTimeTicks         |
  | 7.1.9       | Opaque            | mibObjectValueOctetString       |
  | 7.1.10      | Counter64         | mibObjectValueCounter           |
  | 7.1.11      | Unsigned32        | mibObjectValueUnsigned          |
  | 7.1.12      | SEQUENCE          | mibObjectValueRow               |
  | 7.1.12      | SEQUENCE OF       | mibObjectValueTable             |
  +-------------+-------------------+---------------------------------+

              Table 1: SMIv2 SYNTAX to mibObjectValue Types

  Values are encoded as per the standard IPFIX encoding of Abstract
  Data Types.  The only new encoding reference in this document is that
  Object Identifiers (OIDs) will be encoded as per ASN.1/BER [X.690] in
  an octetArray.

  The mibObjectValue and mibObjectIdentifier Information Elements are
  standard IPFIX fields.  Therefore, the E bit of the mibObjectValue or
  mibObjectIdentifier Information Elements is set to 0.






Aitken, et al.               Standards Track                   [Page 14]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


  The MIB object being exported may be defined in an enterprise-
  specific MIB module, but the Information Elements defined in this
  standard are still exported with the E bit set to 0.  The OID being
  exported indicates that the MIB object was defined in an
  enterprise-specific MIB module.

5.3.  MIB Field Options - Specifications and Required Fields

  For each mibObjectValue Information Element that is defined in an
  IPFIX Template, a MIB Field Options Data Record will be exported that
  provides the required minimum information to define the MIB object
  that is being exported (see Section 5.3.1).

  The MIB Field Options Data Records are defined in a Template referred
  to in this document as a MIB Field Options Template with the format
  specified in Section 5.4.

  The MIB Field Options Template and MIB Field Options Data Records
  MUST be exported in the same IPFIX Message as any Template that is
  using a mibObjectValue Information Element.  Note that this places an
  implicit size constraint on the export.

  This whole set of Templates and MIB Field Options Data Records MUST
  all be exported prior to the corresponding Data Records that depend
  upon them.  That is, the export order MUST be:

  1.  Data Template for mibObjectValue Information Elements (Set ID 2)

  2.  MIB Field Options Template (Set ID 3)

  3.  MIB Field Options Data Records (Set ID >= 256)

  4.  MIB Object Value Data Records (Set ID >= 256)

  Note that the ID of an identical MIB Field Options Template that has
  already been exported MAY be reused without exporting the Template
  again.

  IPFIX Set IDs are defined in Section 3.3.2 of [RFC7011].  A value of
  2 indicates a Template Set, a value of 3 indicates an Options
  Template Set, and values 256 and above indicate Data Sets.










Aitken, et al.               Standards Track                   [Page 15]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


5.3.1.  MIB Field Options Template

  Three fields are REQUIRED to unambiguously export a standalone
  mibObjectValue Information Element with a MIB Field Options Template:

  o  (scope) templateId [IANA-IPFIX]

  o  (scope) informationElementIndex [IANA-IPFIX]

  o  mibObjectIdentifier (Section 11.2.2.1) or mibSubIdentifier
     (Section 11.2.2.2)

  These are the minimum fields required in a MIB Field Options Template
  (see Section 5.4.2).

  The mibObjectIdentifier is used to provide the OID for all
  mibObjectValue Information Elements exported, except when IPFIX
  Structured Data [RFC6313] is being used to export a conceptual row
  (see Section 5.8.2).

  While the following are optional, they are nevertheless RECOMMENDED
  in certain circumstances, as described in the referenced sections:

  o  mibCaptureTimeSemantics
     (discussed in Section 5.4.5; Information Element defined in
     Section 11.2.2.4)

  o  mibIndexIndicator
     (discussed in Section 5.8.5; Information Element defined in
     Section 11.2.2.3)

  o  mibContextEngineID
     (discussed in Section 5.6; Information Element defined in
     Section 11.2.2.5)

  o  mibContextName
     (discussed in Section 5.6; Information Element defined in
     Section 11.2.2.6)

5.3.2.  MIB Type Options Template

  There are also fields that provide type information from a MIB object
  definition that MAY be exported to a Collecting Process.

  Type information is statically defined in a MIB module; it is not
  expected to change.  However, the additional information about the
  MIB object may help a Collecting Process that does not have access to
  the MIB module.



Aitken, et al.               Standards Track                   [Page 16]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


  To export a MIB Type Options Template, the mibObjectIdentifier is
  RECOMMENDED as a Scope Field so that it matches the MIB Field Options
  Template.  Any combination of the other MIB Type fields may be
  included.

  o  (scope) mibObjectIdentifier (see Section 11.2.2.1)

  o  mibObjectName (see Section 11.2.3.1)

  o  mibObjectDescription (see Section 11.2.3.2)

  o  mibObjectSyntax (see Section 11.2.3.3)

  o  mibModuleName (see Section 11.2.3.4)

5.4.  MIB Field Options Template Formats

5.4.1.  Data Template Containing a mibObjectValue Field

  The Template Record format of a Template that uses a mibObjectValue
  Information Element is identical to the standard IPFIX format as
  defined in [RFC7011], so a field using a mibObjectValue Information
  Element is specified using standard IPFIX Field Specifiers per
  [RFC7011].

  The only extra requirement on a Template Record using one or more
  mibObjectValue Information Elements is that it MUST export the
  required metadata specified in Section 5.3.1 for EACH mibObjectValue
  Information Element.

  If multiple MIB Field Options Data Records that refer to a
  mibObjectValue are received, the latest MUST be used.  This matches
  the expected behavior of IPFIX Templates.

  There is a one-to-one mapping between each mibObjectValue Information
  Element and a MIB Field Options Data Record.

  A MIB Field Options Template and corresponding Data Record MUST be
  exported to provide the minimum required metadata.












Aitken, et al.               Standards Track                   [Page 17]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


  Figure 4 shows an IPFIX Template Set using a mibObjectValue
  Information Element.

     0                   1                   2                   3
     0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 2           |          Length = 16          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       Template ID             |         Field Count = 2       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |0| IE = Existing IPFIX Field   |        Field Length           |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |0| IE = <mibObjectValue>       |        Field Length (MIB)     |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

  Figure 4: IPFIX Template Set Using mibObjectValue Information Element

  Where:

     <mibObjectValue>

        One of the mibObjectValue IPFIX Information Elements that
        denotes that MIB object data (i.e., the value of a MIB object)
        will be exported in the (Options) Data Record.

        This could be any one of the mibObjectValue Information
        Elements defined in Section 11.2.1: mibObjectValueInteger,
        mibObjectValueOctetString, mibObjectValueOID,
        mibObjectValueBits, mibObjectValueIPAddress,
        mibObjectValueCounter, mibObjectValueGauge,
        mibObjectValueTimeTicks, mibObjectValueUnsigned,
        mibObjectValueTable, and mibObjectValueRow.

        When a mibObjectValue Information Element is used, the MIB
        Object Identifier ("mibObjectIdentifier") MUST be exported via
        a MIB Field Options Template and MIB Field Options Data Record.
        See Section 5.3.1.

     Field Length (MIB)

        The length of the encoded MIB object data in the corresponding
        Data Records, in octets.  See [RFC7011] for a detailed
        definition.  Note that the Field Length can be expressed using
        reduced-size encoding per [RFC7011].  Note that the Field
        Length may be encoded using variable-length encoding per
        [RFC7011].





Aitken, et al.               Standards Track                   [Page 18]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


5.4.2.  MIB Field Options Template

  The MIB Field Options Template is a standard Options Template that
  defines the fields that will be exported to provide enough metadata
  about a mibObjectValue Information Element so that the Collector can
  tie the data values in the mibObjectValue Information Element back to
  the definition of the MIB object.

  All MIB Field Options Templates contain the fields specified in
  Section 5.3.1.

  Figure 5 shows the required fields to export a mibObjectIdentifier
  for the MIB Field Options Template format.

     0                   1                   2                   3
     0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 3           |          Length = 22          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       Template ID             |        Field Count = 3        |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |   Scope Field Count = 2       |0| IE = templateId             |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 2       |0| IE = informationElementIndex|
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 2       |0| IE = mibObjectIdentifier    |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 65535   |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

      Figure 5: MIB Field Options Template Format - Required Fields

  Where:

     templateId

        The first Scope Field is an IPFIX Information Element that
        denotes that a Template Identifier will be exported as part of
        the MIB Field Options Data Record.  This Template Identifier,
        paired with an index into that Template (the
        "informationElementIndex" field), uniquely references one
        mibObjectValue Information Element being exported.









Aitken, et al.               Standards Track                   [Page 19]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


     informationElementIndex

        The second Scope Field is an IPFIX Information Element that
        denotes a zero-based index into the fields defined by a
        Template.  When paired with a "templateId", this uniquely
        references one mibObjectValue Information Element being
        exported.

     mibObjectIdentifier

        An IPFIX Information Element that denotes the MIB Object
        Identifier for the mibObjectValue Information Element exported
        in the (Options) Template Record.

        When a MIB Object Value Information Element is used, the MIB
        Object Identifier MUST be specified in the MIB Field Options
        Template Record or specified by other means.

        The Object Identifier is encoded in the IPFIX Data Record in
        ASN.1/BER [X.690] format.

        Variable-length encoding SHOULD be used with the
        mibObjectIdentifier so that multiple MIB OIDs of different
        lengths can be exported efficiently.  This will also allow
        reuse of the MIB Field Options Template.

        Variable-length encoding is indicated by the Field Length value
        of 65535, per Sections 3.2 and 7 of [RFC7011].  The RECOMMENDED
        use of variable-length encoding for mibObjectIdentifier fields
        is indicated in subsequent figures by placing 65535 in the
        relevant length fields.

5.4.3.  MIB Field Options Data Records

  The MIB Field Options Data Records conform to the Template
  Specification in the MIB Field Options Template.  There may be
  multiple MIB Field Options Data Records exported.

  The Collecting Process MUST store all received MIB Field Options Data
  information for the duration of each Transport Session, because the
  Collecting Process will need to refer to the extra meta-information
  to fully decode each mibObjectValue Information Element.









Aitken, et al.               Standards Track                   [Page 20]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


  Figure 6 shows the format of the exported MIB Field Options
  Data Record, detailing the metadata that will be exported to match
  the Template in Figure 5.

     0                   1                   2                   3
     0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID               |          Length = N           |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        templateId             |  informationElementIndex      |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |   VLEN        |                  mibObjectIdentifier ...      |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        ... mibObjectIdentifier (continued) ...                |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        templateId             |  informationElementIndex      |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |    VLEN       |  mibObjectIdentifier  ...                     |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        ... mibObjectIdentifier (continued) ...                |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

            Figure 6: Format of MIB Field Options Data Record

  VLEN contains the variable length of the mibObjectIdentifier per
  Section 7 of [RFC7011].

5.4.4.  Options Template Containing a mibObjectValue Field

  The Options Template Record format of a Template that uses a
  mibObjectValue Information Element is identical to the standard
  format as defined in [RFC7011].  The mibObjectValue Information
  Element is specified using standard Field Specifiers per [RFC7011].

  A mibObjectValue Information Element can be either a Scope Field or a
  non-Scope Field in an Options Template Record.

  The only extra requirement on an Options Template Record using one or
  more mibObjectValue Information Elements is that it MUST export the
  required metadata specified in Section 5.3.1 for EACH mibObjectValue
  Information Element.

  An IPFIX Options Template Record MUST export a MIB Field Options
  Template and Data Record to provide the minimum required metadata for
  each mibObjectValue Information Element.






Aitken, et al.               Standards Track                   [Page 21]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


  Figure 7 shows an IPFIX Options Template Set using an existing IPFIX
  field as a Scope Field and with a mibObjectValueInteger Information
  Element as a non-Scope Field, while Figure 8 shows an IPFIX Options
  Template Set using a mibObjectValueInteger Information Element as a
  Scope Field with an existing IPFIX field as a non-Scope Field.

     0                   1                   2                   3
     0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 3           |          Length = 18          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       Template ID             |         Field Count = 2       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |      Scope Field Count = 1    |0| IE = Existing IPFIX Field   |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length           |0| IE = mibObjectValueInteger  |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length           |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

         Figure 7: IPFIX Options Template Set Using a Non-Scope
                       mibObjectValueInteger Field

     0                   1                   2                   3
     0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 3           |          Length = 18          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       Template ID             |         Field Count = 2       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |      Scope Field Count = 1    |0| IE = mibObjectValueInteger  |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length           |0| IE = Existing IPFIX Field   |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length           |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

           Figure 8: IPFIX Options Template Set Using a Scope
                       mibObjectValueInteger Field












Aitken, et al.               Standards Track                   [Page 22]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


5.4.5.  MIB Field Options Template with Semantics Fields

  A MIB Field Options Template MAY specify that extra Information
  Elements will be exported to record how the mibObjectValue was
  collected.

  Alternatively, one of the existing IPFIX observationTime* elements
  [IANA-IPFIX] may be exported to specify exactly when the value was
  collected.

  Figure 9 shows the MIB Field Options Template for a non-columnar
  field with Semantic Data.

     0                   1                   2                   3
     0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 3           |          Length = 26          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       Template ID             |        Field Count = 4        |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |   Scope Field Count = 2       |0| IE = templateId             |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 2       |0| IE = informationElementIndex|
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 2       |0| IE = mibObjectIdentifier    |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 65535   |0| IE = mibCaptureTimeSemantics|
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 1       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

      Figure 9: MIB Field Options Template for a Non-columnar Field
                           with Semantic Data

  Where:

     mibObjectIdentifier

        Note the use of variable-length encoding for this field.

     mibCaptureTimeSemantics

        The MIB Capture Time Semantics IPFIX Information Element, as
        defined in Section 11.2.2.4.

        It is RECOMMENDED to include this field when exporting a
        mibObjectValue Information Element that specifies counters or
        statistics, particularly for situations with long-lived Flows.



Aitken, et al.               Standards Track                   [Page 23]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


5.4.6.  MIB Field Options Template with Extra MIB Object Details

  The OID exported within the mibObjectIdentifier IPFIX Information
  Element provides an OID reference to a MIB object type definition
  that will fully describe the MIB object data being exported.

  However, an Exporting Process MAY decide to include some extra fields
  to more fully describe the MIB object that is being exported with a
  mibObjectValue Information Element.

  This can be helpful if the Collecting Process may not have access to
  the MIB module.

  The Exporting Process can either include the fields with extra object
  details as part of the MIB Field Options Template or export a
  separate Options Template and a Data Record that maps MIB OIDs in
  mibObjectIdentifier fields to the object details.

  If only a few fields are being exported, then including extra type
  data in the MIB Field Options export will be more efficient.































Aitken, et al.               Standards Track                   [Page 24]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


  The MIB Field Options Template for a non-columnar field with extra
  MIB object details is shown in Figure 10.

     0                   1                   2                   3
     0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 3           |          Length = 38          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       Template ID             |        Field Count = 7        |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |   Scope Field Count = 2       |0| IE = templateId             |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 2       |0| IE = informationElementIndex|
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 2       |0| IE = mibObjectIdentifier    |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 65535   |0| IE = mibObjectSyntax        |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 65535   |0| IE = mibObjectName          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 65535   |0| IE = mibObjectDescription   |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 65535   |0| IE = mibModuleName          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 65535   |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

     Figure 10: MIB Field Options Template for a Non-columnar Field
                      with Extra MIB Object Details

  Where:

     mibObjectSyntax

        The MIB object syntax string as defined in Section 11.2.3.3.

        Note that a separate mibObjectSyntax Information Element is
        required (rather than extend the existing "IPFIX Information
        Elements" subregistry [IANA-IPFIX] that contains
        informationElementDataType) because the SYNTAX clause could
        contain almost any name.

     mibObjectName

        The textual name of a mibObjectIdentifier object.






Aitken, et al.               Standards Track                   [Page 25]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


     mibObjectDescription

        The textual description for a mibObjectIdentifier.

     mibModuleName

        The textual name of the MIB module that defines a MIB object.

     Note the use of variable-length encoding for the
     mibObjectIdentifier, mibObjectSyntax, mibObjectName,
     mibObjectDescription, and mibModuleName, since these are all
     string fields.

  The MIB details can be exported in Data Records specified using a
  regular IPFIX Options Template Record [RFC7011], as shown in
  Figure 11.  This may be more efficient, as the bulk of this data is
  text based and SHOULD be exported only once to the Collecting Process
  if there are many MIB objects being exported.  This prevents this
  large textual data from being included for every use of a
  mibObjectValue Information Element.

     0                   1                   2                   3
     0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 3           |          Length = 30          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       Template ID             |        Field Count = 5        |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |   Scope Field Count = 1       |0| IE = mibObjectIdentifier    |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 65535   |0| IE = mibObjectSyntax        |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 65535   |0| IE = mibObjectName          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 65535   |0| IE = mibObjectDescription   |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 65535   |0| IE = mibModuleName          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 65535   |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

     Figure 11: Alternative mibObjectIdentifier Options Template Set
                           with Object Details








Aitken, et al.               Standards Track                   [Page 26]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


5.5.  Use of Field Order in the MIB Field Options Template

  The MIB Field Options Template export makes use of the
  informationElementIndex [IANA-IPFIX] to specify which field in the
  Template the metadata relates to; this avoids any ordering
  constraints on the Data Template.  The mibObjectValue Information
  Elements in an IPFIX export can be in any order in the export packet.
  However, fields used as an INDEX MUST be in the same order as the
  order specified in the INDEX clause of the conceptual row MIB object.

  The informationElementIndex specifies which field in the Template
  extra information is being provided for.

  This is analogous to standard IPFIX Template Sets, which also specify
  the order of the fields and provide their type and size.

  If the Template changes such that the order is different, then the
  MIB Field Options Data MUST be resent to reflect the new ordering.  A
  new Template ID MUST be used to reflect that the ordering has
  changed.  Older MIB Field Options Data may refer to the incorrect
  field.

  A templateId [IANA-IPFIX] is only locally unique within a combination
  of an Observation Domain and Transport Session.  As such, each MIB
  Field Options Data Record can only refer to templateIds within the
  same Observation Domain and session.

5.6.  Identifying the SNMP Context

  Each MIB OID is looked up in a specific context, usually the default
  context.  If exporting a MIB OID value that isn't in the default
  context, then the context MUST be identified by including the
  mibContextEngineID (see Section 11.2.2.5) and mibContextName (see
  Section 11.2.2.6) fields in the MIB Field Options Template and
  associated MIB Field Options Data Records, or be included in the same
  Template as the mibObjectValue field.

  This context data MUST be included for each field that is not in the
  default context.

  The context information MAY be exported as part of the Template that
  includes the mibObjectValue Information Element, or the context
  information MAY be exported in the MIB Field Options Data Record that
  refers to the field.  Context fields exported in the same Template
  MUST take precedence over those that refer to the Template.  Context
  fields MUST apply to all mibObjectValue Information Elements in the
  same Template, and there MUST NOT be duplicates of mibContextName or
  mibContextEngineID in a Template.



Aitken, et al.               Standards Track                   [Page 27]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


  So, a MIB Field Options Template MAY specify no context information,
  just the context engine ID or both the context engine and context
  name.  This allows the Exporter to export the bulk of data in the
  default context and only tag those items that are required.

  Since the MIB Field Options Template applies for all the Data Records
  of a Template, using context fields in the MIB Field Options Data
  Template requires that each mibContextEngineID / mibContextName pair
  have its own Template.

5.7.  Template Management

  Templates are managed as per Section 8 of [RFC7011], with the
  additional constraint that the MIB Field Options Template and MIB
  Field Options Data Records MUST be exported in the same IPFIX Message
  as any (Options) Template Record that uses a mibObjectValue
  Information Element.

  When exporting over a Stream Control Transmission Protocol (SCTP)
  transport [RFC4960], the MIB Field Options Data Records MUST be
  exported reliably and in the same SCTP stream as their associated
  Templates per [RFC6526].

  If a Template using a mibObjectValue Information Element is resent
  for any reason, the Data Records it depends on MUST be sent as well.

  If a Template is replaced with a new (Options) Template, then a new
  MIB Field Options Data Record MUST be sent with the replacement
  referencing the new Template ID.

  An Exporting Process SHOULD reuse MIB Field Options Template IDs when
  the Templates are identical.  Each (Options) Template Record MUST
  still be accompanied by a copy of the MIB Field Options Template.

5.7.1.  Large Messages

  The requirement to export the MIB Field Options Template and MIB
  Field Options Data Records in the same IPFIX Message as any (Options)
  Template Record that uses a mibObjectValue Information Element may
  result in very large IPFIX Messages.

  In environments with restricted Message sizes, and only when a
  reliable SCTP transport is being used, the MIB Field Options
  Template, MIB Field Options Data, Data Template, and Data Records MAY
  be exported in separate Messages in the same SCTP stream, provided
  that their order is maintained.





Aitken, et al.               Standards Track                   [Page 28]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


5.7.2.  Template Withdrawal and Reuse

  Data Records containing mibObjectValue Information Elements MUST NOT
  be exported if their corresponding Data Template or MIB Field Options
  Template has been withdrawn, since the MIB Field Options Template
  MUST be exported in the same IPFIX Message as the Data Template that
  it annotates, except as allowed by the caveat mentioned in
  Section 5.7.1.

  MIB Field Options Template IDs MUST NOT be reused while they are
  required by any existing Data Templates.

5.8.  Exporting Conceptual Rows and Tables

  There are three approaches for an IPFIX Exporting Process to export
  the values of columnar objects:

  1.  Ignoring the indexing of columnar objects

  2.  Exporting conceptual rows / table objects using IPFIX Structured
      Data [RFC6313]

  3.  Exporting individual indexed columnar objects

  Firstly, a subordinate columnar object may be used purely as a data
  type.  In this case, there is no index information or relation to a
  conceptual row object provided by the Exporting Process.

  Secondly, mibObjectValueRow or mibObjectValueTable can be used to
  export partial or complete conceptual rows, using IPFIX Structured
  Data [RFC6313].

  Thirdly, in a mixed option/data IPFIX/MIB Template, the
  mibObjectValue Information Element can have the values of the INDEX
  clause of the conceptual row provided by other fields in the
  Data Record.  In this case, each mibObjectValue Information Element
  must specify which other field(s) in the Template is providing the
  index information.













Aitken, et al.               Standards Track                   [Page 29]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


5.8.1.  Exporting Conceptual Rows - Indexing

  This document defines two forms of indexing that can be used for
  conceptual row MIB objects:

  Indexing based on IPFIX Structured Data [RFC6313] is used solely by
  the mibObjectValueRow Information Element.  Each conceptual row of
  the MIB object corresponds to a single Data Record exported.  The
  index fields defined in the INDEX clause of the MIB object MUST all
  be present in the same order as the Scope Fields.  This allows a
  simple table export of a conceptual row MIB object without any extra
  fields required to indicate which fields make up the conceptual row
  INDEX.

  Field-based indexing is used by giving each mibObjectValue
  Information Element a mibIndexIndicator to flag the required index
  fields.  This allows complex indexing or mixing of existing IPFIX
  Information Elements with MIB fields, with minimum overhead.  It also
  allows multiple columnar MIB objects from different conceptual rows
  to be exported with complete indexing in one IPFIX Template.

5.8.2.  Exporting Conceptual Rows - mibObjectValueRow

  The simplest approach to exporting a complete or partial conceptual
  row object is done with the mibObjectValueRow Information Element.

  This is an IPFIX Structured Data subTemplateList Information Element
  as detailed in [RFC6313].  The Template specified MUST be an Options
  Template.  It also MUST have the fields specified in the INDEX clause
  of the conceptual row object as the Scope Fields in the MIB Field
  Options Template and Data Set.

  An overview of this architecture is given in Figure 12.  This shows
  that the full MIB object type definition OID is exported for the
  mibObjectValueRow conceptual row field but that the individual
  columnar objects only require the sub-identifier to be exported.  To
  make the diagram clearer, the Templates for the MIB Field Options
  Templates are not shown.













Aitken, et al.               Standards Track                   [Page 30]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


       +---------------------------+    +------------------------+
       | Data Template             |    | MIB Field Options Data |
       |                           |    |                        |
       | mibObjectValueRow         |<---| OID                    |
       +---------------------------+    +------------------------+
         |
         | +-----------------------+    +------------------------+
         | | Options Template      |    | MIB Field Options Data |
         | |                       |    |                        |
         | | Scope mibObjectValue* |<---| mibSubIdentifier       |
         | |       mibObjectValue* |<---| mibSubIdentifier       |
         | +-----------------------+    +------------------------+
         |             |
         V             V
       +---------------------------+
       | Data Flows                |
       |                           |
       | subTemplateList (1 entry) |
       +---------------------------+

          Figure 12: Architecture for Exporting Conceptual Rows
                         with mibObjectValueRow

  The mibIndexIndicator is not required for each individual
  mibObjectValue Information Element, as mibObjectValueRow provides a
  structure that includes the index details.

  When indexing based on IPFIX Structured Data [RFC6313] is used, all
  Scope Fields MUST be the INDEX objects in the same order as defined
  in the INDEX clause of the conceptual row being exported.

  Each conceptual table MIB object has two related OIDs.  There is an
  OID that refers to the table with the syntax of SEQUENCE OF and an
  OID that refers to each entry or conceptual row with the syntax of
  SEQUENCE.  The OID for the SEQUENCE of a conceptual row MUST be
  exported.

  For example, in the IF-MIB [RFC2863], the OID for ifEntry should be
  exported rather than the OID for ifTable.  The OID for the table (in
  this case, ifTable) can be derived by removing one sub-identifier
  from the ifEntry OID.

  The full OID for the conceptual row MIB object type definition being
  exported with the mibObjectValueRow Information Element MUST be
  exported.  However, the fields that are members of the conceptual row
  need not have the full OID of their MIB object type definition
  exported.  Instead, the mibSubIdentifier Information Element can be
  used to document which entry in the conceptual row the field is.



Aitken, et al.               Standards Track                   [Page 31]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


  In this case, the exported Flow will contain a single complete or
  partial row from a table inside a single field of the Data Record.

  There may be MIB objects that are specified in the INDEX of the
  conceptual row but not columnar objects of the same conceptual row;
  for these, the Exporter MUST provide the full OID in a
  mibObjectIdentifier field.

  So, for a conceptual row object with the OID "1.2.3.4.5.6" the OID of
  the type definitions for columnar objects "1.2.3.4.5.6.1"
  "1.2.3.4.5.6.2" can be exported with just a mibSubIdentifier of "1"
  and "2", respectively.

  The mibObjectValue Information Elements exported using the
  mibObjectValueRow export MUST all either be objects defined in the
  INDEX clause, columnar objects of the same conceptual row object, or
  columnar objects that augment the same conceptual row.

  The IPFIX Structured Data [RFC6313] subTemplateList format requires
  the Structured Data Type Semantics to be specified.  Unless there is
  a more appropriate option in the "IPFIX Structured Data Types
  Semantics" subregistry [IANA-IPFIX], the "undefined" Structured Data
  Type Semantics can be used.

  Figure 13 shows an IPFIX Template for an IPFIX Structured Data
  [RFC6313] export of a conceptual row, while Figure 14 shows an IPFIX
  Options Template for a complete conceptual row with five columns and
  two index fields.  Figure 15 shows the MIB Field Options Template for
  a conceptual row field.  Figure 16 shows the MIB Field Options
  Template for the columns inside the conceptual row.  Figure 17 shows
  the OID Data for the conceptual row that will be exported.

     0                   1                   2                   3
     0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 2           |          Length = 12          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       Template ID = 300       |         Field Count = 1       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |0| IE = mibObjectValueRow      |         Field Length          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

             Figure 13: IPFIX Template for a Conceptual Row








Aitken, et al.               Standards Track                   [Page 32]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


     0                   1                   2                   3
     0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 3           |          Length = 30          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       Template ID = 301       |         Field Count = 5       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |      Scope Field Count = 2    |0| IE = mibObjectValue INDEX1  |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length           |0| IE = mibObjectValue INDEX2  |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length           |0| IE = mibObjectValue COLUMN3 |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length           |0| IE = mibObjectValue COLUMN4 |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length           |0| IE = mibObjectValue COLUMN5 |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length           |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

        Figure 14: IPFIX Options Template for a mibObjectValueRow
                 with Five Columns and Two Index Fields

     0                   1                   2                   3
     0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 3           |          Length = 22          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       Template ID = 302       |        Field Count = 3        |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |   Scope Field Count = 2       |0| IE = templateId             |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 2       |0| IE = informationElementIndex|
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 2       |0| IE = mibObjectIdentifier    |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 65535   |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

    Figure 15: MIB Field Options Template for a Conceptual Row Object











Aitken, et al.               Standards Track                   [Page 33]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


  Where:

     templateId

        The templateId for the MIB option that will be exported.

     mibObjectIdentifier

        The MIB OID for the conceptual row that is being exported.
        Note the use of variable-length encoding for this field.

     0                   1                   2                   3
     0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 3           |          Length = 22          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       Template ID = 303       |        Field Count = 3        |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |   Scope Field Count = 2       |0| IE = templateId             |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 2       |0| IE = informationElementIndex|
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 2       |0| IE = mibSubIdentifier       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 2       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

       Figure 16: MIB Field Options Template for Columnar Objects
                          of a Conceptual Table

  Where:

     templateId

        The templateId used will be for the Template referred to in the
        subTemplateList of the mibObjectValueRow that will be exported.

     mibSubIdentifier

        The sub-identifier that specifies the columnar object's ID
        within the conceptual row.










Aitken, et al.               Standards Track                   [Page 34]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


     0                   1                   2                   3
     0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 302         |          Length = N           |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       Template ID = 300       |  informationElementIndex      |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |   VLEN        |                  mibObjectIdentifier ...      |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        ... mibObjectIdentifier (continued) ...                |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 303         |          Length = N           |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        templateId = 301       |  informationElementIndex      |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |  mibSubIdentifier             |        templateId = 301       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |  informationElementIndex      |  mibSubIdentifier             |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        templateId = 301       |  informationElementIndex      |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |  mibSubIdentifier             |        templateId = 301       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |  informationElementIndex      |  mibSubIdentifier             |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        templateId = 301       |  informationElementIndex      |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |  mibSubIdentifier             |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

         Figure 17: mibOption Data Record for the Conceptual Row

  Where:

     mibObjectIdentifier

        Will contain the OID for the conceptual row as a whole.

     mibSubIdentifier

        The mibSubIdentifier fields will contain the extra
        sub-identifier that, when added to the OID for the conceptual
        row, gives the full OID for the object.






Aitken, et al.               Standards Track                   [Page 35]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


5.8.3.  Exporting Conceptual Rows - AUGMENTS

  SMIv2 defines conceptual rows as having either an INDEX clause or an
  AUGMENTS clause.  Conceptual row definitions with an AUGMENTS clause
  extend an existing base conceptual row with an INDEX clause.  It is
  not possible in SMIv2 to augment a conceptual row that itself has an
  AUGMENTS clause.  The base table and the augmentation have an
  identical INDEX.

  Since augmentations allow adding extra columns to existing tables, it
  is beneficial to be able to support them easily in IPFIX exports of
  conceptual rows.

  The mibObjectValueRow OID MAY refer to either the base table with the
  INDEX clause or a conceptual row with an AUGMENTS clause.  The
  mibSubIdentifier in any MIB Field Options Data Record MUST always
  refer to the OID exported for the mibObjectValueRow Information
  Element.

  If the mibObjectValueRow OID refers to a base table, then any extra
  columns from conceptual rows with an AUGMENTS clause MUST have their
  full OID exported.

  If the mibObjectValueRow OID refers to a conceptual row that augments
  another conceptual row using the AUGMENTS clause, then any MIB fields
  from the original table's INDEX or columnar objects MUST NOT use the
  mibSubIdentifier and MUST instead export the full OID in a
  mibObjectIdentifier.

  If the mibObjectValueRow refers to an augmenting conceptual row, the
  Scope Fields of the Template used in the subTemplateList MUST have
  the index fields from the base table, in the same order as its scope.
  This is identical to the Scope Field requirements for conceptual rows
  with an INDEX clause.

  This flexibility is provided so that the conceptual rows with the
  most columns can be exported using the more efficient
  mibSubIdentifier.  For example, exporting a complete set of
  augmentation columns would only require the full OIDs for the MIB
  objects in the INDEX.

  It is possible to export MIB object columns from multiple augmenting
  conceptual rows.  If this is done, then the base table SHOULD be used
  as the main OID for the mibObjectValueRow.







Aitken, et al.               Standards Track                   [Page 36]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


5.8.4.  Exporting Conceptual Tables - mibObjectValueTable

  Multiple rows of a conceptual table can be exported in the
  mibObjectValueTable Information Element (Section 11.2.1.10).  This
  allows a set of conceptual rows corresponding to a conceptual table
  to be exported as a single field.  Therefore, a complete set of rows
  can be exported as a single field with other Information Elements in
  a Template.  In this fashion, several complete conceptual tables
  could be exported in one packet.

  As also specified for mibObjectValueRow (Section 5.8.2), the more
  specific (i.e., full) OID of the SEQUENCE entity MUST be exported.

  The format of mibObjectValueTable is identical to mibObjectValueRow,
  except that the length of the subTemplateList may be zero or more
  entries.

  All the other, i.e., non-length, requirements for mibObjectValueRow
  in Section 5.8.2 apply to mibObjectValueTable.

  An overview of this architecture is given in Figure 18.  This
  architecture is similar to the architecture shown in Figure 12.

       +---------------------------+    +------------------------+
       | Data Template             |    | MIB Field Options Data |
       |                           |    |                        |
       | mibObjectValueTable       |<---| OID                    |
       +---------------------------+    +------------------------+
         |
         | +-----------------------+    +------------------------+
         | | Options Template      |    | MIB Field Options Data |
         | |                       |    |                        |
         | | Scope mibObjectValue* |<---| mibSubIdentifier       |
         | |       mibObjectValue* |<---| mibSubIdentifier       |
         | +-----------------------+    +------------------------+
         |             |
         V             V
       +-----------------------------+
       | Data Flows                  |
       |                             |
       | subTemplateList (n entries) |
       |    row 1                    |
       |    ...                      |
       |    row n                    |
       +-----------------------------+

         Figure 18: Architecture for Exporting Conceptual Tables
                        with mibObjectValueTable



Aitken, et al.               Standards Track                   [Page 37]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


5.8.5.  Exporting Columnar Objects: Using mibIndexIndicator

  The other option for indexing a columnar object that is part of a
  conceptual table is explicit indexing.  In this case, the Options
  Template Set scope may contain either non-index fields or columnar
  MIB objects from multiple conceptual rows being exported.  In this
  case, each mibObjectValue Information Element requires the
  mibIndexIndicator with the bits set for the fields that are used to
  index that individual columnar object.

  The index fields MUST be in the "correct" order as defined in the
  conceptual row that each columnar object is a member of.

  If a mibObjectValue Information Element that is being indexed using
  mibIndexIndicator is being used as an Options Template Scope Field,
  then all fields used to index that field MUST also be Scope Fields.

  Figure 19 shows the MIB Field Options Template for an indexed MIB
  columnar object.

     0                   1                   2                   3
     0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 3           |          Length = 26          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       Template ID             |        Field Count = 4        |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |   Scope Field Count = 2       |0| IE = templateId             |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 2       |0| IE = informationElementIndex|
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 2       |0| IE = mibIndexIndicator      |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 2       |0| IE = mibObjectIdentifier    |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 65535   |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

          Figure 19: MIB Field Options Template for an Indexed
                           MIB Columnar Object











Aitken, et al.               Standards Track                   [Page 38]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


  Where:

     mibIndexIndicator

        The MIB Index Indicator IPFIX Information Element that marks
        which fields in the Data Record will act as INDEX values for
        the exported MIB object.

        The index data for a mibObjectValue will be other fields
        contained in the same Data Record.  The mibIndexIndicator marks
        the fields whose value(s) should be added to the OID for the
        MIB object type definition exported in mibObjectIdentifier to
        get the OID for the instance of the MIB object.

        Elements used to index MIB objects MUST be exported in the same
        order as they are specified in the index field of the
        conceptual table they belong to.

     mibObjectIdentifier

        Note the use of variable-length encoding for this field.

6.  Example Use Cases

6.1.  Non-columnar MIB Object: Established TCP Connections

  The number of established TCP connections of a remote network device
  could be monitored by configuring it to periodically export the
  number of established TCP connections to a centralized Collector.  In
  this example, the Exporter would export an IPFIX Message every
  30 minutes that contained Data Records detailing the number of
  established TCP connections.

  The table of data that is to be exported looks like:

           +-------------------------+-----------------------+
           |        TIMESTAMP        | ESTABLISHED TCP CONN. |
           +-------------------------+-----------------------+
           | StartTime +   0 seconds |           10          |
           | StartTime +  60 seconds |           14          |
           | StartTime + 120 seconds |           19          |
           | StartTime + 180 seconds |           16          |
           | StartTime + 240 seconds |           23          |
           | StartTime + 300 seconds |           29          |
           +-------------------------+-----------------------+

                  Table 2: Established TCP Connections




Aitken, et al.               Standards Track                   [Page 39]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


  The Template Record for such a Data Record will provide details for
  the following two Information Elements:

  1.  flowStartSeconds from [IANA-IPFIX], Information Element 150: The
      absolute timestamp of the first packet of this Flow.

  2.  tcpCurrEstab from [RFC4022], Object ID "1.3.6.1.2.1.6.9": The
      number of TCP connections for which the current state is either
      ESTABLISHED or CLOSE-WAIT.

  Figure 20 shows the exported Template Set detailing the
  Template Record for exporting the number of established TCP
  connections.

     0                   1                   2                   3
     0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 2           |          Length = 16          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       Template ID = 400       |        Field Count = 2        |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |0|   IE = flowStartSeconds     |        Field Length = 4       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |0|   IE = mibObjectValueGauge  |        Field Length = 4       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

             Figure 20: Example of tcpCurrEstab Template Set
























Aitken, et al.               Standards Track                   [Page 40]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


  Figure 21 shows the exported MIB Field Options Template Set detailing
  the metadata that will be exported about the mibObjectValueGauge
  Information Element in Template 400 in Template Record.

     0                   1                   2                   3
     0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 3           |          Length = 22          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       Template ID = 401       |        Field Count = 3        |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |  Scope Field Count = 2        |0| IE = templateId             |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 2       |0| IE = informationElementIndex|
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 2       |0| IE = mibObjectIdentifier    |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 65535   |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

    Figure 21: Example of tcpCurrEstab MIB Field Options Template Set

  Figure 22 shows the exported MIB Field Options Data Set detailing the
  metadata that will be exported about the mibObjectValueGauge
  Information Element in Template 400 in Template Record.

  The OID for the MIB object tcpCurrEstab from [RFC4022], Object ID
  "1.3.6.1.2.1.6.9", will be encoded in ASN.1/BER [X.690] as
  "06072B060102010609" in the Data Record, which takes 9 octets.

     0                   1                   2                   3
     0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 401         |          Length = 18          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       Template ID = 400       | informationElementIndex = 1   |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |   VLEN = 9    | mibObjectIdentifier ...                       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       ... mibObjectIdentifier = "1.3.6.1.2.1.6.9" ...         |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |   ... 06072B060102010609 ...  |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

      Figure 22: Example of tcpCurrEstab MIB Field Options Data Set






Aitken, et al.               Standards Track                   [Page 41]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


  Figure 23 shows the start of the Data Set for exporting the number of
  established TCP connections (see Section 6.1).

     0                   1                   2                   3
     0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 400         |          Length = 52          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                    StartTime +   0 seconds                    |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                              10                               |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                    StartTime +  60 seconds                    |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                              14                               |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                    StartTime + 120 seconds                    |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                              19                               |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                    StartTime + 180 seconds                    |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                              16                               |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                    StartTime + 240 seconds                    |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                              23                               |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                    StartTime + 300 seconds                    |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                              29                               |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

               Figure 23: Example of tcpCurrEstab Data Set

6.2.  Enterprise-Specific MIB Object: Detailing CPU Load History

  For the sake of demonstration, an enterprise-specific MIB object from
  the CISCO-PROCESS-MIB [CISCO-PROCESS-MIB] is chosen.  This example
  would be valid with any enterprise-specific MIB module.

  The CPU usage of a remote network device with one CPU could be
  monitored by configuring it to periodically export CPU usage
  information, i.e., the cpmCPUTotal1minRev from the proprietary
  CISCO-PROCESS-MIB, Object ID "1.3.6.1.4.1.9.9.109.1.1.1.1.7", to a
  centralized Collector.





Aitken, et al.               Standards Track                   [Page 42]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


  Although the cpmCPUTotal1minRev MIB object is a columnar object in a
  conceptual row, if there is only one CPU no extra information is
  conveyed by providing the index field.  So, in this case, it is
  acceptable to not export the cpmCPUTotalIndex MIB object.  If there
  were multiple CPUs, it would be appropriate to include the
  cpmCPUTotalIndex field and specify the relationship.

  In this example, the Exporter would export an IPFIX Message every
  30 minutes that contained Data Records detailing the CPU 1-minute
  busy average at 1-minute intervals.

  The table of data that is to be exported looks like:

            +-------------------------+---------------------+
            |        TIMESTAMP        | CPU BUSY PERCENTAGE |
            +-------------------------+---------------------+
            | StartTime +   0 seconds |         10%         |
            | StartTime +  60 seconds |         14%         |
            | StartTime + 120 seconds |         19%         |
            | StartTime + 180 seconds |         16%         |
            | StartTime + 240 seconds |         23%         |
            | StartTime + 300 seconds |         29%         |
            +-------------------------+---------------------+

                         Table 3: CPU Usage Data

  The Template Record for such a Data Record will provide details for
  the following two Information Elements:

  1.  flowStartSeconds from [IANA-IPFIX], Information Element 150: The
      absolute timestamp of the first packet of this Flow.

  2.  A mibObjectValueGauge for cpmCPUTotal1minRev, the overall CPU
      busy percentage in the last 1-minute period.

















Aitken, et al.               Standards Track                   [Page 43]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


  Figure 24 shows the exported Template Set detailing the
  Template Record for exporting CPU Load (see Section 6.2).

     0                   1                   2                   3
     0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 2           |          Length = 16          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       Template ID = 402       |        Field Count = 2        |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |0|   IE = flowStartSeconds     |        Field Length = 4       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |0|   IE = mibObjectValueGauge  |        Field Length = 1       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

               Figure 24: Example of CPU Load Template Set

  Figure 25 shows the exported Template Set detailing the MIB Field
  Options Template for exporting CPU Load (see Section 6.2).  Note:
  This is identical to the MIB Field Options Template given in
  Figure 21, so the same Template could have been reused.

     0                   1                   2                   3
     0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 3           |          Length = 22          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       Template ID = 403       |        Field Count = 3        |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |   Scope Field Count = 2       |0| IE = templateId             |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 2       |0| IE = informationElementIndex|
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 2       |0| IE = mibObjectIdentifier    |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 65535   |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

      Figure 25: Example of CPU Load MIB Field Options Template Set

  Figure 26 shows the exported MIB Field Options Data Set detailing the
  metadata that will be exported about the mibObjectValueGauge
  Information Element in Template 402 in Template Record (see
  Section 6.2).

  The OID for the cpmCPUTotal1minRev has been encoded using ASN.1/BER
  to "060D2B0601040109096D0101010107" at 15 octets long.




Aitken, et al.               Standards Track                   [Page 44]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


     0                   1                   2                   3
     0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 403         |          Length = 24          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       Template ID = 402       | informationElementIndex = 1   |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |   VLEN = 15   |  mibObjectIdentifier                     ...  |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |              "1.3.6.1.4.1.9.9.109.1.1.1.1.7"             ...  |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |               060D2B0601040109096D0101010107             ...  |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                                                          ...  |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

        Figure 26: Example of CPU Load MIB Field Options Data Set

  Note that although cpmCPUTotal1minRev is 32 bits long, reduced-size
  encoding [RFC7011] has been used to encode it within a single octet.
  The encoding size was specified by setting the length for the
  mibObjectValueGauge field to 1 octet in the main Data Template; see
  Figure 24.

  This example stresses that, even though the OID cpmCPUTotal1minRev is
  enterprise-specific, the E bit for the mibObjectValueGauge and
  mibObjectIdentifier is set to 0, because the mibObjectValueGauge and
  mibObjectIdentifier Information Elements are not enterprise-specific.
  That this data is from an Enterprise MIB is included in the OID that
  includes an Enterprise ID.

  The corresponding Data Set does not add any value for this example
  and is therefore not displayed.

6.3.  Exporting a Conceptual Row: The OSPF Neighbor Row

  Many conceptual tables are already defined in standard and
  proprietary MIBs.  These can be exported with a minimum of overhead
  by using the mibObjectValueRow.  This allows the Exporting Process to
  unambiguously define the INDEX for the entire conceptual row as the
  Scope Fields of an Options Template Set.  The use of a MIB Field
  Options Template with mibSubIdentifier being used means that each
  individual columnar object does not need to have its OID exported to
  the Collector.







Aitken, et al.               Standards Track                   [Page 45]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


  The ospfNbrTable, defined in the OSPF MIB [RFC4750], consists of
  ospfNbrEntry, which has the OID "1.3.6.1.2.1.14.10.1".  Each
  mibObjectValueRow Data Record will therefore correspond to an
  ospfNbrEntry.

  The following fields will be exported:

  +------------------+----------------+-------------------------+-----+
  | Object           | ID             | mibObjectValue          | Len |
  +------------------+----------------+-------------------------+-----+
  | ospfNbrIpAddr    | ospfNbrEntry 1 | mibObjectValueIPAddress |  4  |
  | ospfNbrAddress-  | ospfNbrEntry 2 | mibObjectValueInteger   |  4  |
  | -LessIndex       |                |                         |     |
  | ospfNbrRtrId     | ospfNbrEntry 3 | mibObjectValueIPAddress |  4  |
  | ospfNbrState     | ospfNbrEntry 6 | mibObjectValueInteger   |  1  |
  +------------------+----------------+-------------------------+-----+

                  Table 4: OSPF Neighbor Entry Objects

  The OIDs that will be used to export this table are shown in Table 5.

   +------------------+-----------------------+---------------------+
   | Entity           | Full OID              | Exported as         |
   +------------------+-----------------------+---------------------+
   | ospfNbrEntry     | 1.3.6.1.2.1.14.10.1   | 1.3.6.1.2.1.14.10.1 |
   | ospfNbrIpAddr    | 1.3.6.1.2.1.14.10.1.1 | 1                   |
   | ospfNbrAddress-  | 1.3.6.1.2.1.14.10.1.2 | 2                   |
   | -LessIndex       |                       |                     |
   | ospfNbrRtrId     | 1.3.6.1.2.1.14.10.1.3 | 3                   |
   | ospfNbrState     | 1.3.6.1.2.1.14.10.1.6 | 6                   |
   +------------------+-----------------------+---------------------+

                           Table 5: OSPF OIDs

  Figure 27 shows the Templates exported to support the
  mibObjectValueRow.  Figure 28 shows the example OID Data for the
  conceptual row exported in mibObjectValueRow.  Figure 29 shows the
  example data export for a few neighbors in the table; Figure 29 also
  shows a Data Record formatted as per IPFIX Structured Data [RFC6313]
  and using the "undefined" (= 0xFF) semantic from the "IPFIX
  Structured Data Types Semantics" subregistry [IANA-IPFIX].  Note that
  the OID for ospfNbrEntry has been encoded using ASN.1/BER to
  "06082B060102010E0A01" at 10 octets long.








Aitken, et al.               Standards Track                   [Page 46]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


     0                   1                   2                   3
     0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 2           |          Length = 12          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       Template ID = 500       |         Field Count = 1       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |0| IE = mibObjectValueRow      |         Field Length = 16     |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 3           |          Length = 26          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       Template ID = 501       |        Field Count = 4        |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |   Scope Field Count = 2       |0| IE = mibObjectValueIPAddress|
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 4       |0| IE = mibObjectValueInteger  |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 4       |0| IE = mibObjectValueIPAddress|
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 4       |0| IE = mibObjectValueInteger  |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 1       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

                                    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
                                    |       Set ID = 3              |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Length = 22          |      Template ID = 502        |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Count = 3        |  Scope Field Count = 2        |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |0| IE = templateId             |        Field Length = 2       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |0| IE = informationElementIndex|        Field Length = 2       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |0| IE = mibObjectIdentifier    |        Field Length = 65535   |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+












Aitken, et al.               Standards Track                   [Page 47]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 3           |          Length = 22          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       Template ID = 503       |        Field Count = 3        |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |   Scope Field Count = 2       |0| IE = templateId             |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 2       |0| IE = informationElementIndex|
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 2       |0| IE = mibSubIdentifier       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 2       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

  Figure 27: Example of ospfNbrEntry Template and Options Template Sets

     0                   1                   2                   3
     0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 502         |          Length = 20          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       Template ID = 500       | informationElementIndex = 0   |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |   VLEN = 10   | mibObjectIdentifier = "1.3.6.1.2.1.14.10.1"   |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                  06082B060102010E0A01                         |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                                               | Padding = 0   |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 503         |          Length = 28          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       templateId = 501        |  informationElementIndex = 0  |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |     mibSubIdentifier = 1      |        templateId = 501       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |  informationElementIndex = 1  |      mibSubIdentifier = 2     |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       templateId = 501        |  informationElementIndex = 2  |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |     mibSubIdentifier = 3      |        templateId = 501       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |  informationElementIndex = 3  |      mibSubIdentifier = 6     |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

           Figure 28: Example of ospfNbrEntry OID Data Export




Aitken, et al.               Standards Track                   [Page 48]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


     0                   1                   2                   3
     0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 500         |          Length = 52          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |Semantic=0xFF  |     Template ID = 501         |        ...    |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       ospfNbrIpAddr = 192.0.2.1               |        ...    |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       ospfNbrAddressLessIndex = 0             |        ...    |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       ospfNbrRtrId = 1.1.1.1                  |ospfNbrState=8 |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |Semantic=0xFF  |     Template ID = 501         |        ...    |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       ospfNbrIpAddr = 192.0.2.2               |        ...    |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       ospfNbrAddressLessIndex = 0             |        ...    |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       ospfNbrRtrId = 2.2.2.2                  |ospfNbrState=8 |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |Semantic=0xFF  |     Template ID = 501         |        ...    |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       ospfNbrIpAddr = 192.0.2.3               |        ...    |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       ospfNbrAddressLessIndex = 0             |        ...    |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       ospfNbrRtrId = 3.3.3.3                  |ospfNbrState=1 |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

           Figure 29: Example of Data Export for ospfNbrEntry

6.4.  Exporting Augmented Conceptual Row: Mapping IF-MIB ID to Name

  The ifTable, defined in the IF-MIB [RFC2863], is augmented by the
  ifXTable (defined in the same MIB module).

  The OID of the ifEntry is 1.3.6.1.2.1.2.2.1, which is encoded using
  ASN.1/BER to "06082B06010201020201" at 10 octets long, while the OID
  of the augmenting ifXEntry is 1.3.6.1.2.1.31.1.1.1, which is encoded
  using ASN.1/BER to "060A2B060102011F01010101" at 12 octets long.

  This example demonstrates how columnar objects from the base
  conceptual row and the augmenting row can be exported in a single
  mibObjectValueRow Information Element.






Aitken, et al.               Standards Track                   [Page 49]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


  Table 6 shows the fields that will be exported.

       +---------+------------------+-------+-------------------+
       | ifIndex | ifType           | ifMtu | ifName            |
       +---------+------------------+-------+-------------------+
       | 1       | ethernetCsmacd:6 | 1500  | Ethernet 10       |
       | 2       | ethernetCsmacd:6 | 1500  | Ethernet 20       |
       | 3       | ethernetCsmacd:6 | 1500  | FastEthernet 30   |
       +---------+------------------+-------+-------------------+

                          Table 6: IF-MIB Data

  The OIDs that will be used to export this table are shown in Table 7.

  +---------+------------------------+--------------------------------+
  | Entity  | Full OID               | Exported as                    |
  +---------+------------------------+--------------------------------+
  | ifEntry | 1.3.6.1.2.1.2.2.1      | OID   = 1.3.6.1.2.1.2.2.1      |
  | ifIndex | 1.3.6.1.2.1.2.2.1.1    | subID = 1                      |
  | ifType  | 1.3.6.1.2.1.2.2.1.3    | subID = 3                      |
  | ifMtu   | 1.3.6.1.2.1.2.2.1.4    | subID = 4                      |
  | ifName  | 1.3.6.1.2.1.31.1.1.1.1 | OID   = 1.3.6.1.2.1.31.1.1.1.1 |
  +---------+------------------------+--------------------------------+

                          Table 7: IF-MIB OIDs

  Figure 30 shows the Templates exported to support the
  mibObjectValueRow Information Element.  Figure 31 shows the example
  OID Data for the conceptual row exported in mibObjectValueRow to
  match Table 7.  Figure 32 shows the example data export as per
  Table 6.




















Aitken, et al.               Standards Track                   [Page 50]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


     0                   1                   2                   3
     0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 2           |          Length = 12          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       Template ID = 600       |         Field Count = 1       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |0| IE = mibObjectValueRow      |         Field Length = 24     |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 3           |          Length = 26          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       Template ID = 601       |        Field Count = 4        |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |   Scope Field Count = 1       |0| IE = mibObjectValueInteger  |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 1       |0| IE = mibObjectValueInteger  |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 2       |0| IE = mibObjectValueInteger  |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 2       |0|IE =mibObjectValueOctetString|
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 65535   |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

                                    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
                                    |       Set ID = 3              |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Length = 22          |      Template ID = 602        |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Count = 3        |   Scope Field Count = 2       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |0| IE = templateId             |        Field Length = 2       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |0| IE = informationElementIndex|        Field Length = 2       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |0| IE = mibObjectIdentifier    |        Field Length = 65535   |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+












Aitken, et al.               Standards Track                   [Page 51]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 3           |          Length = 22          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       Template ID = 603       |        Field Count = 3        |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |   Scope Field Count = 2       |0| IE = templateId             |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 2       |0| IE = informationElementIndex|
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 2       |0| IE = mibSubIdentifier       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 2       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

          Figure 30: Example of Augmented ifEntry Template and
                          Options Template Sets



































Aitken, et al.               Standards Track                   [Page 52]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


     0                   1                   2                   3
     0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 602         |          Length = 40          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       Template ID = 600       | informationElementIndex = 0   |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |   VLEN = 10   | mibObjectIdentifier ...                       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |              ifEntry = 1.3.6.1.2.1.2.2.1                      |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |              06082B06010201020201             |   Padding = 0 |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        templateId = 601       | informationElementIndex = 3   |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |   VLEN = 12   | mibObjectIdentifier ifName ...                |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |              ifName = 1.3.6.1.2.1.31.1.1.1.1                  |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |              060A2B060102011F01010101                         |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |               |                  Padding = 0                  |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 603         |          Length = 22          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       templateId = 601        |  informationElementIndex = 0  |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |     mibSubIdentifier = 1      |        templateId = 601       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |  informationElementIndex = 1  |      mibSubIdentifier = 3     |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       templateId = 601        |  informationElementIndex = 2  |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |     mibSubIdentifier = 4      |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

         Figure 31: Example of Augmented ifEntry OID Data Export












Aitken, et al.               Standards Track                   [Page 53]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


     0                   1                   2                   3
     0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 600         |          Length = 68          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |Semantic=0xFF  |     Template ID = 601         | ifIndex = 1   |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       ifType = 6              |        ifMtu = 1500           |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |  Length = 11  |      ifName = Ethernet 10                     |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                        ...                                    |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                        ...                                    |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |Semantic=0xFF  |     Template ID = 601         | ifIndex = 2   |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       ifType = 6              |        ifMtu = 1500           |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |  Length = 11  |      ifName = Ethernet 20                     |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                        ...                                    |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                        ...                                    |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |Semantic=0xFF  |     Template ID = 601         | ifIndex = 3   |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       ifType = 6              |        ifMtu = 1500           |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |  Length = 15  |      ifName = FastEthernet 30                 |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                        ...                                    |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                        ...                                    |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                        ...                                    |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

         Figure 32: Example of Data Export for Augmented ifEntry












Aitken, et al.               Standards Track                   [Page 54]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


6.5.  Exporting a Columnar Object: ipIfStatsInForwDatagrams

  It may be that the full set of columnar objects that are supported by
  a conceptual row are not required to be exported.  Rather than use
  the IPFIX Structured Data [RFC6313] method, the mibIndexIndicator
  method can be used to provide the relationship between fields.

  This example shows the MIB objects that are part of the INDEX of the
  conceptual row being exported in the correct order and then being
  referred to by using mibIndexIndicator.

  This example shows the export of ipIfStatsInForwDatagrams from the
  IP-MIB [RFC4293].  ipIfStatsInForwDatagrams is a columnar object that
  is part of the ipIfStatsTable conceptual table.  This is comprised of
  ipIfStatsEntry conceptual rows.

  The ipIfStatsTable conceptual table is indexed by ipIfStatsIPVersion
  and ipIfStatsIfIndex.

  The Options Template Record for the example Data Record contains the
  following Information Elements:

  1.  ipIfStatsIPVersion (1.3.6.1.2.1.4.31.3.1.1) (Scope Field)
      (encoded using ASN.1/BER to "060A2B06010201041F030101" at
      12 octets long)

  2.  ipIfStatsIfIndex (1.3.6.1.2.1.4.31.3.1.2) (Scope Field)
      (encoded using ASN.1/BER to "060A2B06010201041F030102" at
      12 octets long)

  3.  ipIfStatsInForwDatagrams (1.3.6.1.2.1.4.31.3.1.12) (non-Scope
      Field)
      (encoded using ASN.1/BER to "060A2B06010201041F03010C" at
      12 octets long)

  Note that ipIfStatsIfIndex has been reduced-size encoded to 2 octets
  in the following example.  An exporting device with more interfaces
  would use the full length.













Aitken, et al.               Standards Track                   [Page 55]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


  Figure 33 shows the exported Options Template Set.

     0                   1                   2                   3
     0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 3           |          Length = 22          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       Template ID = 701       |        Field Count = 3        |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |     Scope Field Count = 2     |0|Scope 1=mibObjectValueInteger|
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |   Scope Field 1 Length = 1    |0|Scope 2=mibObjectValueInteger|
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |   Scope Field 1 Length = 2    |0| IE = mibObjectValueCounter  |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |           Field Length = 4    |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

   Figure 33: Example of an Options Template for an Indexed MIB Object
                         with Two Index Objects

  Figure 34 shows the exported MIB Field Options Template used to
  export the required mibObjectValue Information Element metadata.
  This example of the MIB Field Options Template includes the
  mibIndexIndicator to indicate that some of the other fields in the
  Data Records are index objects.

     0                   1                   2                   3
     0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 3           |          Length = 26          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       Template ID = 702       |        Field Count = 4        |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |   Scope Field Count = 2       |0| IE = templateId             |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 2       |0| IE = informationElementIndex|
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 2       |0| IE = mibIndexIndicator      |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 1       |0| IE = mibObjectIdentifier    |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 65535   |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

    Figure 34: Example of a MIB Field Options Template for an Indexed
                    MIB Object with Two Index Objects




Aitken, et al.               Standards Track                   [Page 56]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


  Figure 35 shows the exported MIB Field Options Data used to export
  the required mibObjectValue Information Element metadata.  Note that
  the first two Data Records have all their mibIndexIndicator bits set
  to 0.  The third mibIndexIndicator has the value "00000011" to show
  that the first two fields in the Data Record are the INDEXes for this
  columnar object.

     0                   1                   2                   3
     0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 702         |          Length = 58          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       Template ID = 701       | informationElementIndex = 0   |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |Index 00000000 | VLEN = 12     | mibObjectIdentifier       ... |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |              "1.3.6.1.2.1.4.31.3.1.1"                     ... |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |               060A2B06010201041F030101                    ... |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                               |        templateId = 701       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    | informationElementIndex = 1   |Index 00000000 |   VLEN = 12   |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |  mibObjectIdentifier = "1.3.6.1.2.1.4.31.3.1.2"           ... |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                         060A2B06010201041F030102          ... |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                                                           ... |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        templateId = 701       | informationElementIndex = 2   |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    | Index 00000011 |  VLEN = 12   | mibObjectIdentifier      ...  |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                  "1.3.6.1.2.1.4.31.3.1.12"               ...  |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                   060A2B06010201041F03010C               ...  |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                               |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

    Figure 35: Example of a MIB Field Options Data Set for an Indexed
                    MIB Object with Two Index Objects








Aitken, et al.               Standards Track                   [Page 57]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


  Figure 36 shows the Data Records that export the values of the three
  mibObjectValue Information Elements.

     0                   1                   2                   3
     0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 701         |          Length = 18          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    | ipVer = 1     |     ifIndex = 10              |  ...          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |    InForwDatagrams = 10000                    | ipVer = 2     |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |    ifIndex = 10               | InForwDatagrams = 20000       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |             ...               |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

     Figure 36: Example of a MIB Data Set for an Indexed MIB Object
                         with Two Index Objects

6.6.  Exporting a Columnar Object Indexed by Information Elements:
     ifOutQLen

  If a Packet Sampling (PSAMP) Packet Report [RFC5476] was generated on
  any dropped packets on an interface, then it may be desirable to know
  if the send queue on the output interface was full.  This could be
  done by exporting the size of the send queue (ifOutQLen) in the same
  Data Record as the PSAMP Packet Report.

  The exported data looks like:

  +-----------+-----------+---------+--------------+------------------+
  |  SRC ADDR |  DST ADDR | PKT LEN |    OUTPUT    | OUTPUT QUEUE LEN |
  |           |           |         |  INTERFACE   |   (ifOutQLen)    |
  +-----------+-----------+---------+--------------+------------------+
  | 192.0.2.1 | 192.0.2.3 |   150   | Eth 1/0 (15) |        45        |
  | 192.0.2.4 | 192.0.2.9 |   350   | Eth 1/0 (15) |        45        |
  | 192.0.2.3 | 192.0.2.9 |   650   | Eth 1/0 (15) |        23        |
  | 192.0.2.4 | 192.0.2.6 |   350   | Eth 1/1 (16) |         0        |
  +-----------+-----------+---------+--------------+------------------+

        Table 8: Packet Report with Interface Output Queue Length
                            (ifOutQLen) Data

  The ifOutQLen MIB object, defined in the IF-MIB [RFC2863], provides
  the length of the output packet queue.  This columnar object is part
  of the ifEntry conceptual row and indexed by the interface index
  (ifIndex).



Aitken, et al.               Standards Track                   [Page 58]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


  This relationship between the ifOutQLen field and the index field is
  exported using mibIndexIndicator in the MIB Field Options Template.
  The value of "00001000" flags the index fields concisely.

  The Template Record for the example Data Record contains the
  following Information Elements:

  1.  sourceIPv4Address

  2.  destinationIPv4Address

  3.  totalLengthIPv4

  4.  egressInterface

  5.  ifOutQLen (indexed by egressInterface)

  Figure 37 shows the exported Template Set detailing the Template for
  exporting a PSAMP Report with ifOutQLen.  Figures 38 and 39 show the
  MIB Field Options Template and Data Record.

     0                   1                   2                   3
     0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 2           |          Length = 28          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       Template ID = 703       |        Field Count = 5        |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |0| IE = sourceIPv4Address      |        Field Length = 4       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |0| IE = destinationIPv4Address |        Field Length = 4       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |0| IE = totalLengthIPv4        |        Field Length = 4       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |0| IE = egressInterface        |        Field Length = 4       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |0| IE = mibObjectValueGauge    |        Field Length = 4       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

    Figure 37: Example of Template for a PSAMP Report with ifOutQLen
                       Indexed by egressInterface










Aitken, et al.               Standards Track                   [Page 59]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


     0                   1                   2                   3
     0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 3           |          Length = 26          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       Template ID = 704       |        Field Count = 4        |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |   Scope Field Count = 2       |0| IE = templateId             |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 2       |0| IE = informationElementIndex|
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 2       |0| IE = mibIndexIndicator      |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 1       |0| IE = mibObjectIdentifier    |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 65535   |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

   Figure 38: Example of MIB Field Options Template for a PSAMP Report
                with ifOutQLen Indexed by egressInterface

     0                   1                   2                   3
     0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 704         |          Length = 21          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       Template ID = 703       | informationElementIndex = 4   |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |Index 00001000  | VLEN = 11    | mibObjectIdentifier    ...    |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |             "1.3.6.1.2.1.2.2.1.21"                     ...    |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |              06092B0601020102020115                    ...    |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |               |
    +-+-+-+-+-+-+-+-+

     Figure 39: Example of MIB Field Options Data Record for a PSAMP
            Report with ifOutQLen Indexed by egressInterface

  The corresponding IPFIX Data Record is shown in Figure 40.  For the
  sake of the example, the interface index of "Eth 1/0" is 15 and the
  interface index of "Eth 1/1" is 16.








Aitken, et al.               Standards Track                   [Page 60]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


     0                   1                   2                   3
     0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 703         |          Length = 84          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                          192.0.2.1                            |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                          192.0.2.3                            |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                             150                               |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                        15 (Eth 1/0)                           |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                              45                               |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                          192.0.2.4                            |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                          192.0.2.9                            |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                             350                               |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                        15 (Eth 1/0)                           |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                              45                               |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                          192.0.2.3                            |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                          192.0.2.9                            |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                             650                               |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                        15 (Eth 1/0)                           |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                              23                               |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                          192.0.2.4                            |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                          192.0.2.6                            |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                             350                               |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                        16 (Eth 1/1)                           |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                               0                               |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

        Figure 40: Example of PSAMP Packet Report with ifOutQLen
                       Indexed by egressInterface



Aitken, et al.               Standards Track                   [Page 61]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


6.7.  Exporting with Multiple Contexts: The OSPF Neighbor Row Revisited

  If the context used to export the MIB objects is the default one, no
  extra context fields are required.  This example demonstrates how to
  handle the case when the context needs to be specified.  It is based
  on the previous example (Section 6.3).

  The OSPF details of the conceptual row that was exported per
  Section 6.3 would be suitable if there were only one OSPF process
  running at the Observation Point.  If multiple OSPF processes are
  present, then they can be differentiated by also exporting the
  mibContextEngineID and mibContextName.

  The following fields will be exported:

  +------------------+----------------+-------------------------+-----+
  | Object           | ID             | mibObjectValue          | Len |
  +------------------+----------------+-------------------------+-----+
  | ospfNbrIpAddr    | ospfNbrEntry 1 | mibObjectValueIPAddress |  4  |
  | ospfNbrAddress-  | ospfNbrEntry 2 | mibObjectValueInteger   |  4  |
  | -LessIndex       |                |                         |     |
  | ospfNbrRtrId     | ospfNbrEntry 3 | mibObjectValueIPAddress |  4  |
  | ospfNbrState     | ospfNbrEntry 6 | mibObjectValueInteger   |  1  |
  +------------------+----------------+-------------------------+-----+

                  Table 9: OSPF Neighbor Entry Objects

  The example contextEngineID matches the example from [RFC3411] for
  Acme Networks: "'800002B804616263'H (enterprise 696, string "abc")".

  Figure 41 shows the Templates exported to support a mibObjectValueRow
  that is defined within a context.  Figure 42 shows the example OID
  Data for the conceptual row exported in mibObjectValueRow.  These are
  unchanged from the previous example (Section 6.3).  Figure 43 shows
  the example data for two OSPF neighbors.  Although these have
  identical INDEX/scope values, the context information indicates that
  they come from different OSPF processes.  Note that the OID for
  ospfNbrEntry has been encoded using ASN.1/BER to
  "06082B060102010E0A01" at 10 octets long.












Aitken, et al.               Standards Track                   [Page 62]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


     0                   1                   2                   3
     0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 2           |          Length = 20          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       Template ID = 800       |         Field Count = 3       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |0| IE = mibContextEngineID     |         Field Length = 8      |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |0| IE = mibContextName         |         Field Length = 4      |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |0| IE = mibObjectValueRow      |         Field Length = 16     |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 3           |          Length = 26          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       Template ID = 801       |        Field Count = 4        |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |   Scope Field Count = 2       |0| IE = mibObjectValueIPAddress|
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 4       |0| IE = mibObjectValueInteger  |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 4       |0| IE = mibObjectValueIPAddress|
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 4       |0| IE = mibObjectValueInteger  |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 1       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

                                    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
                                    |       Set ID = 3              |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Length = 22          |      Template ID = 802        |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Count = 3        |  Scope Field Count = 2        |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |0| IE = templateId             |        Field Length = 2       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |0| IE = informationElementIndex|        Field Length = 2       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |0| IE = mibObjectIdentifier    |        Field Length = 65535   |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+








Aitken, et al.               Standards Track                   [Page 63]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 3           |          Length = 22          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       Template ID = 803       |        Field Count = 3        |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |   Scope Field Count = 2       |0| IE = templateId             |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 2       |0| IE = informationElementIndex|
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 2       |0| IE = mibSubIdentifier       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |        Field Length = 2       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

  Figure 41: Example of ospfNbrEntry Template and Options Template Sets
                              with Context

     0                   1                   2                   3
     0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 802         |          Length = 20          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       Template ID = 800       | informationElementIndex = 2   |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |   VLEN = 10   | mibObjectIdentifier = "1.3.6.1.2.1.14.10.1"   |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                     06082B060102010E0A01                      |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |                                               | Padding = 0   |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 803         |          Length = 28          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       templateId = 801        |  informationElementIndex = 0  |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |     mibSubIdentifier = 1      |        templateId = 801       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |  informationElementIndex = 1  |      mibSubIdentifier = 2     |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       templateId = 801        |  informationElementIndex = 2  |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |     mibSubIdentifier = 3      |        templateId = 801       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |  informationElementIndex = 3  |      mibSubIdentifier = 6     |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

     Figure 42: Example of ospfNbrEntry OID Data Export with Context



Aitken, et al.               Standards Track                   [Page 64]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


     0                   1                   2                   3
     0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |          Set ID = 800         |          Length = 60          |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |  mibContextEngineID = 800002B804616263                        |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |  ... mibContextEngineID                                       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |  mibContextName = con1                                        |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |Semantic=0xFF  |     Template ID = 801         |        ...    |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       ospfNbrIpAddr = 192.0.2.1               |        ...    |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       ospfNbrAddressLessIndex = 0             |        ...    |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       ospfNbrRtrId = 1.1.1.1                  |ospfNbrState=8 |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |  mibContextEngineID = 800002B804616263                        |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |  ... mibContextEngineID                                       |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |  mibContextName = con2                                        |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |Semantic=0xFF  |     Template ID = 801         |        ...    |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       ospfNbrIpAddr = 192.0.2.2               |        ...    |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       ospfNbrAddressLessIndex = 0             |        ...    |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
    |       ospfNbrRtrId = 2.2.2.2                  |ospfNbrState=8 |
    +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+

     Figure 43: Example of Data Export for ospfNbrEntry with Context

7.  Configuration Considerations

  When configuring a MIB OID for export, consideration should be given
  to whether the SNMP context should also be configurable.  If a
  non-default context is used, then it should be associated with the
  fields as per Section 5.6.









Aitken, et al.               Standards Track                   [Page 65]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


8.  The Collecting Process's Side

  The specifications in Section 9 of [RFC7011] also apply to Collectors
  that implement this specification.  In addition, the following
  specifications should be noted:

  o  A Collecting Process that implements this specification MUST store
     the Data Records containing the OID object type definitions with
     the same retention policy as Templates.

  o  A Collecting Process that implements this specification SHOULD
     have access to MIB modules in order to look up the received MIB
     Object Identifiers and find the full type definition and name of
     MIB OID fields used in received Templates.

  o  It should be noted that, because reduced-size encoding MAY be used
     by the Exporting Process, the Collecting Process cannot assume
     that a received size for a field is the maximum size it should
     expect for that field.

  o  If a Collecting Process receives a MIB Object Identifier that it
     cannot decode, it MAY log a warning.

  o  A Collecting Process MUST support the three options for handling
     columnar objects detailed in Section 5.8.

9.  Applicability

  Making available the many and varied items from MIB modules opens up
  a wide range of possible applications for the IPFIX protocol, some
  quite different from the usual Flow information.

  Some monitoring applications periodically export a mapping of
  interface ID to interface name using IPFIX Options Templates.  This
  could be expanded to include the ifInUcastPkts MIB object as defined
  in the IF-MIB [RFC2863], indexed using the ingressInterface
  Information Element.  This would provide the input statistics for
  each interface; these statistics can be compared to the Flow
  information to ensure that the sampling rate is as expected, or, in
  the absence of sampling, to ensure that all expected packets are
  being monitored.










Aitken, et al.               Standards Track                   [Page 66]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


10.  Security Considerations

  For this extension to the IPFIX protocol, the same security
  considerations as those for the IPFIX protocol apply [RFC7011].

  If the Exporter is generating or capturing the field values itself,
  e.g., using the MIB objects only as an encoding or type mechanism,
  there are no extra security considerations beyond standard IPFIX.

  However, if the Exporter is implemented as an SNMP manager accessing
  an SNMP agent, it MUST authenticate itself to the SNMP agent
  [RFC3414] [RFC5591] [RFC5592] [RFC6353], and the SNMP agent MUST
  enforce SNMP access control rules [RFC3415] as required by the SNMP
  architecture [RFC3411].

  Access to particular MIB objects is controlled by the configuration
  of the IPFIX Exporter.  This is consistent with the way IPFIX
  controls access to other Information Elements in general.

  The configuration of an IPFIX Exporter determines which MIB objects
  are included in IPFIX Data Records sent to certain Collectors.
  Network operators should take care that the only MIB objects that are
  included in IPFIX Data Records are objects that the receiving
  Collector is allowed to receive.  Note that multiple users may have
  access to the data from the Collector.

  When exporting MIB objects that may be considered sensitive or
  vulnerable in some network environments (as mentioned in the Security
  Considerations section of the RFC containing the MIB module), the
  Exporter should consider using anonymization techniques per [RFC6235]
  if the information is anonymizable.  Consumers of exported data
  should therefore be able to handle the kinds of data modifications
  that are described in [RFC6235].


















Aitken, et al.               Standards Track                   [Page 67]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


11.  IANA Considerations

11.1.  New IPFIX Semantics

  New IPFIX semantics have been allocated in IANA's IPFIX registry
  [IANA-IPFIX] per Section 6 of [RFC7012], as defined in the
  subsections below.

11.1.1.  snmpCounter

  An integral value reporting the value of a counter, identical to the
  Counter32 and Counter64 semantics in [RFC2578], as determined by the
  Field Length.

  This is similar to IPFIX's totalCounter semantic, except that total
  counters have an initial value of 0 but SNMP counters do not.

  IANA has assigned value 7 to snmpCounter.

11.1.2.  snmpGauge

  An integral value identical to the Gauge32 semantic in [RFC2578] and
  the Gauge64 semantic in [RFC2856], as determined by the Field Length.

  IANA has assigned value 8 to snmpGauge.


























Aitken, et al.               Standards Track                   [Page 68]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


11.2.  New IPFIX Information Elements

  The new Information Elements in Table 10 have been allocated in
  IANA's IPFIX registry [IANA-IPFIX], as defined in the subsections
  below.

  In each case, the "Units" and "Range" have been left blank, since
  these are not applicable.

                +-----------+---------------------------+
                | ElementId | Name                      |
                +-----------+---------------------------+
                | 434       | mibObjectValueInteger     |
                | 435       | mibObjectValueOctetString |
                | 436       | mibObjectValueOID         |
                | 437       | mibObjectValueBits        |
                | 438       | mibObjectValueIPAddress   |
                | 439       | mibObjectValueCounter     |
                | 440       | mibObjectValueGauge       |
                | 441       | mibObjectValueTimeTicks   |
                | 442       | mibObjectValueUnsigned    |
                | 443       | mibObjectValueTable       |
                | 444       | mibObjectValueRow         |
                | 445       | mibObjectIdentifier       |
                | 446       | mibSubIdentifier          |
                | 447       | mibIndexIndicator         |
                | 448       | mibCaptureTimeSemantics   |
                | 449       | mibContextEngineID        |
                | 450       | mibContextName            |
                | 451       | mibObjectName             |
                | 452       | mibObjectDescription      |
                | 453       | mibObjectSyntax           |
                | 454       | mibModuleName             |
                +-----------+---------------------------+

                   Table 10: New Information Elements

11.2.1.  New MIB Object Value Information Elements

11.2.1.1.  mibObjectValueInteger

  A new Information Element "mibObjectValueInteger" has been allocated
  in IANA's IPFIX registry [IANA-IPFIX], with the following definition:

     Description: An IPFIX Information Element that denotes that the
     integer value of a MIB object will be exported.  The MIB Object
     Identifier ("mibObjectIdentifier") for this field MUST be exported
     in a MIB Field Option or via another means.  This Information



Aitken, et al.               Standards Track                   [Page 69]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


     Element is used for MIB objects with the Base syntax of Integer32
     and INTEGER with IPFIX reduced-size encoding used as required.
     The value is encoded as per the standard IPFIX Abstract Data Type
     of signed32.

     Abstract Data Type: signed32

     Data Type Semantics: quantity

     ElementId: 434

     Status: current

     Reference: RFC 8038

11.2.1.2.  mibObjectValueOctetString

  A new Information Element "mibObjectValueOctetString" has been
  allocated in IANA's IPFIX registry [IANA-IPFIX], with the following
  definition:

     Description: An IPFIX Information Element that denotes that an
     Octet String or Opaque value of a MIB object will be exported.
     The MIB Object Identifier ("mibObjectIdentifier") for this field
     MUST be exported in a MIB Field Option or via another means.  This
     Information Element is used for MIB objects with the Base syntax
     of OCTET STRING and Opaque.  The value is encoded as per the
     standard IPFIX Abstract Data Type of octetArray.

     Abstract Data Type: octetArray

     Data Type Semantics: default

     ElementId: 435

     Status: current

     Reference: RFC 8038

11.2.1.3.  mibObjectValueOID

  A new Information Element "mibObjectValueOID" has been allocated in
  IANA's IPFIX registry [IANA-IPFIX], with the following definition:

     Description: An IPFIX Information Element that denotes that an
     Object Identifier or OID value of a MIB object will be exported.
     The MIB Object Identifier ("mibObjectIdentifier") for this field
     MUST be exported in a MIB Field Option or via another means.  This



Aitken, et al.               Standards Track                   [Page 70]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


     Information Element is used for MIB objects with the Base syntax
     of OBJECT IDENTIFIER.  Note: In this case, the
     "mibObjectIdentifier" defines which MIB object is being exported,
     and the "mibObjectValueOID" field will contain the OID value of
     that MIB object.  The mibObjectValueOID Information Element is
     encoded as ASN.1/BER [X.690] in an octetArray.

     Abstract Data Type: octetArray

     Data Type Semantics: default

     ElementId: 436

     Status: current

     Reference: RFC 8038

11.2.1.4.  mibObjectValueBits

  A new Information Element "mibObjectValueBits" has been allocated in
  IANA's IPFIX registry [IANA-IPFIX], with the following definition:

     Description: An IPFIX Information Element that denotes that a set
     of Enumerated flags or bits from a MIB object will be exported.
     The MIB Object Identifier ("mibObjectIdentifier") for this field
     MUST be exported in a MIB Field Option or via another means.  This
     Information Element is used for MIB objects with the Base syntax
     of BITS.  The flags or bits are encoded as per the standard IPFIX
     Abstract Data Type of octetArray, with sufficient length to
     accommodate the required number of bits.  If the number of bits is
     not an integer multiple of octets, then the most significant bits
     at the end of the octetArray MUST be set to 0.

     Abstract Data Type: octetArray

     Data Type Semantics: flags

     ElementId: 437

     Status: current

     Reference: RFC 8038









Aitken, et al.               Standards Track                   [Page 71]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


11.2.1.5.  mibObjectValueIPAddress

  A new Information Element "mibObjectValueIPAddress" has been
  allocated in IANA's IPFIX registry [IANA-IPFIX], with the following
  definition:

     Description: An IPFIX Information Element that denotes that the
     IPv4 address value of a MIB object will be exported.  The MIB
     Object Identifier ("mibObjectIdentifier") for this field MUST be
     exported in a MIB Field Option or via another means.  This
     Information Element is used for MIB objects with the Base syntax
     of IpAddress.  The value is encoded as per the standard IPFIX
     Abstract Data Type of ipv4Address.

     Abstract Data Type: ipv4Address

     Data Type Semantics: default

     ElementId: 438

     Status: current

     Reference: RFC 8038

11.2.1.6.  mibObjectValueCounter

  A new Information Element "mibObjectValueCounter" has been allocated
  in IANA's IPFIX registry [IANA-IPFIX], with the following definition:

     Description: An IPFIX Information Element that denotes that the
     counter value of a MIB object will be exported.  The MIB Object
     Identifier ("mibObjectIdentifier") for this field MUST be exported
     in a MIB Field Option or via another means.  This Information
     Element is used for MIB objects with the Base syntax of Counter32
     or Counter64 with IPFIX reduced-size encoding used as required.
     The value is encoded as per the standard IPFIX Abstract Data Type
     of unsigned64.

     Abstract Data Type: unsigned64

     Data Type Semantics: snmpCounter

     ElementId: 439

     Status: current

     Reference: RFC 8038




Aitken, et al.               Standards Track                   [Page 72]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


11.2.1.7.  mibObjectValueGauge

  A new Information Element "mibObjectValueGauge" has been allocated in
  IANA's IPFIX registry [IANA-IPFIX], with the following definition:

     Description: An IPFIX Information Element that denotes that the
     Gauge value of a MIB object will be exported.  The MIB Object
     Identifier ("mibObjectIdentifier") for this field MUST be exported
     in a MIB Field Option or via another means.  This Information
     Element is used for MIB objects with the Base syntax of Gauge32.
     The value is encoded as per the standard IPFIX Abstract Data Type
     of unsigned32.  This value represents a non-negative integer that
     may increase or decrease but that shall never exceed a maximum
     value or fall below a minimum value.

     Abstract Data Type: unsigned32

     Data Type Semantics: snmpGauge

     ElementId: 440

     Status: current

     Reference: RFC 8038

11.2.1.8.  mibObjectValueTimeTicks

  A new Information Element "mibObjectValueTimeTicks" has been
  allocated in IANA's IPFIX registry [IANA-IPFIX], with the following
  definition:

     Description: An IPFIX Information Element that denotes that the
     TimeTicks value of a MIB object will be exported.  The MIB Object
     Identifier ("mibObjectIdentifier") for this field MUST be exported
     in a MIB Field Option or via another means.  This Information
     Element is used for MIB objects with the Base syntax of TimeTicks.
     The value is encoded as per the standard IPFIX Abstract Data Type
     of unsigned32.

     Abstract Data Type: unsigned32

     Data Type Semantics: quantity

     ElementId: 441

     Status: current

     Reference: RFC 8038



Aitken, et al.               Standards Track                   [Page 73]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


11.2.1.9.  mibObjectValueUnsigned

  A new Information Element "mibObjectValueUnsigned" has been allocated
  in IANA's IPFIX registry [IANA-IPFIX], with the following definition:

     Description: An IPFIX Information Element that denotes that an
     unsigned integer value of a MIB object will be exported.  The MIB
     Object Identifier ("mibObjectIdentifier") for this field MUST be
     exported in a MIB Field Option or via another means.  This
     Information Element is used for MIB objects with the Base syntax
     of unsigned32 with IPFIX reduced-size encoding used as required.
     The value is encoded as per the standard IPFIX Abstract Data Type
     of unsigned32.

     Abstract Data Type: unsigned32

     Data Type Semantics: quantity

     ElementId: 442

     Status: current

     Reference: RFC 8038

11.2.1.10.  mibObjectValueTable

  A new Information Element "mibObjectValueTable" has been allocated in
  IANA's IPFIX registry [IANA-IPFIX], with the following definition:

     Description: An IPFIX Information Element that denotes that a
     complete or partial conceptual table will be exported.  The MIB
     Object Identifier ("mibObjectIdentifier") for this field MUST be
     exported in a MIB Field Option or via another means.  This
     Information Element is used for MIB objects with a syntax of
     SEQUENCE OF.  This is encoded as a subTemplateList of
     mibObjectValue Information Elements.  The Template specified in
     the subTemplateList MUST be an Options Template and MUST include
     all the objects listed in the INDEX clause as Scope Fields.

     Abstract Data Type: subTemplateList

     Data Type Semantics: list

     ElementId: 443

     Status: current

     Reference: RFC 8038



Aitken, et al.               Standards Track                   [Page 74]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


11.2.1.11.  mibObjectValueRow

  A new Information Element "mibObjectValueRow" has been allocated in
  IANA's IPFIX registry [IANA-IPFIX], with the following definition:

     Description: An IPFIX Information Element that denotes that a
     single row of a conceptual table will be exported.  The MIB Object
     Identifier ("mibObjectIdentifier") for this field MUST be exported
     in a MIB Field Option or via another means.  This Information
     Element is used for MIB objects with a syntax of SEQUENCE.  This
     is encoded as a subTemplateList of mibObjectValue Information
     Elements.  The subTemplateList exported MUST contain exactly one
     row (i.e., one instance of the subTemplate).  The Template
     specified in the subTemplateList MUST be an Options Template and
     MUST include all the objects listed in the INDEX clause as Scope
     Fields.

     Abstract Data Type: subTemplateList

     Data Type Semantics: list

     ElementId: 444

     Status: current

     Reference: RFC 8038

11.2.2.  New MIB Field Options Information Elements

11.2.2.1.  mibObjectIdentifier

  A new Information Element "mibObjectIdentifier" has been allocated in
  IANA's IPFIX registry [IANA-IPFIX], with the following definition:

     Description: An IPFIX Information Element that denotes that a MIB
     Object Identifier (MIB OID) is exported in the (Options)
     Template Record.  The mibObjectIdentifier Information Element
     contains the OID assigned to the MIB object type definition
     encoded as ASN.1/BER [X.690].

     Abstract Data Type: octetArray

     Data Type Semantics: default

     ElementId: 445






Aitken, et al.               Standards Track                   [Page 75]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


     Status: current

     Reference: RFC 8038

11.2.2.2.  mibSubIdentifier

  A new Information Element "mibSubIdentifier" has been allocated in
  IANA's IPFIX registry [IANA-IPFIX], with the following definition:

     Description: A non-negative sub-identifier of an Object Identifier
     (OID).

     Abstract Data Type: unsigned32

     Data Type Semantics: identifier

     ElementId: 446

     Status: current

     Reference: RFC 8038

11.2.2.3.  mibIndexIndicator

  A new Information Element "mibIndexIndicator" has been allocated in
  IANA's IPFIX registry [IANA-IPFIX], with the following definition:

     Description: A set of bit fields that is used for marking the
     Information Elements of a Data Record that serve as INDEX MIB
     objects for an indexed columnar MIB object.  Each bit represents
     an Information Element in the Data Record, with the n-th least
     significant bit representing the n-th Information Element.  A bit
     set to 1 indicates that the corresponding Information Element is
     an index of the columnar object represented by the mibObjectValue.
     A bit set to 0 indicates that this is not the case.

     If the Data Record contains more than 64 Information Elements, the
     corresponding Template SHOULD be designed such that all index
     fields are among the first 64 Information Elements, because the
     mibIndexIndicator only contains 64 bits.  If the Data Record
     contains less than 64 Information Elements, then the extra bits in
     the mibIndexIndicator for which no corresponding Information
     Element exists MUST have the value 0 and must be disregarded by
     the Collector.  This Information Element may be exported with
     IPFIX reduced-size encoding.






Aitken, et al.               Standards Track                   [Page 76]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


     Abstract Data Type: unsigned64

     Data Type Semantics: flags

     ElementId: 447

     Status: current

     Reference: RFC 8038

11.2.2.4.  mibCaptureTimeSemantics

  A new Information Element "mibCaptureTimeSemantics" has been
  allocated in IANA's IPFIX registry [IANA-IPFIX], with the following
  definition:

     Description: Indicates when in the lifetime of the Flow the MIB
     value was retrieved from the MIB for a mibObjectIdentifier.  This
     is used to indicate if the value exported was collected from the
     MIB closer to Flow creation or Flow export time and refers to the
     Timestamp fields included in the same Data Record.  This field
     SHOULD be used when exporting a mibObjectValue that specifies
     counters or statistics.

     If the MIB value was sampled by SNMP prior to the IPFIX Metering
     Process or Exporting Process retrieving the value (i.e., the data
     is already stale) and it is important to know the exact sampling
     time, then an additional observationTime* element should be paired
     with the OID using IPFIX Structured Data [RFC6313].  Similarly, if
     different MIB capture times apply to different mibObjectValue
     elements within the Data Record, then individual
     mibCaptureTimeSemantics Information Elements should be paired with
     each OID using IPFIX Structured Data.


















Aitken, et al.               Standards Track                   [Page 77]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


     Values:

        0  undefined

        1  begin - The value for the MIB object is captured from the
           MIB when the Flow is first observed

        2  end - The value for the MIB object is captured from the MIB
           when the Flow ends

        3  export - The value for the MIB object is captured from the
           MIB at export time

        4  average - The value for the MIB object is an average of
           multiple captures from the MIB over the observed life of
           the Flow

     Abstract Data Type: unsigned8

     Data Type Semantics: identifier

     ElementId: 448

     Status: current

     Reference: RFC 8038

11.2.2.5.  mibContextEngineID

  A new Information Element "mibContextEngineID" has been allocated in
  IANA's IPFIX registry [IANA-IPFIX], with the following definition:

     Description: A mibContextEngineID that specifies the SNMP
     engine ID for a MIB field being exported over IPFIX.  Definition
     as per [RFC3411], Section 3.3.

     Abstract Data Type: octetArray

     Data Type Semantics: default

     ElementId: 449

     Status: current

     Reference: RFC 8038






Aitken, et al.               Standards Track                   [Page 78]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


11.2.2.6.  mibContextName

  A new Information Element "mibContextName" has been allocated in
  IANA's IPFIX registry [IANA-IPFIX], with the following definition:

     Description: An Information Element that denotes that a MIB
     context name is specified for a MIB field being exported over
     IPFIX.  Reference [RFC3411], Section 3.3.

     Abstract Data Type: string

     Data Type Semantics: default

     ElementId: 450

     Status: current

     Reference: RFC 8038

11.2.3.  New MIB Type Information Elements

11.2.3.1.  mibObjectName

  A new Information Element "mibObjectName" has been allocated in
  IANA's IPFIX registry [IANA-IPFIX], with the following definition:

     Description: The name (called a descriptor in [RFC2578]) of an
     object type definition.

     Abstract Data Type: string

     Data Type Semantics: default

     ElementId: 451

     Status: current

     Reference: RFC 8038













Aitken, et al.               Standards Track                   [Page 79]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


11.2.3.2.  mibObjectDescription

  A new Information Element "mibObjectDescription" has been allocated
  in IANA's IPFIX registry [IANA-IPFIX], with the following definition:

     Description: The value of the DESCRIPTION clause of a MIB object
     type definition.

     Abstract Data Type: string

     Data Type Semantics: default

     ElementId: 452

     Status: current

     Reference: RFC 8038

11.2.3.3.  mibObjectSyntax

  A new Information Element "mibObjectSyntax" has been allocated in
  IANA's IPFIX registry [IANA-IPFIX], with the following definition:

     Description: The value of the SYNTAX clause of a MIB object type
     definition, which may include a textual convention or sub-typing.
     See [RFC2578].

     Abstract Data Type: string

     Data Type Semantics: default

     ElementId: 453

     Status: current

     Reference: RFC 8038















Aitken, et al.               Standards Track                   [Page 80]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


11.2.3.4.  mibModuleName

  A new Information Element "mibModuleName" has been allocated in
  IANA's IPFIX registry [IANA-IPFIX], with the following definition:

     Description: The textual name of the MIB module that defines a MIB
     object.

     Abstract Data Type: string

     Data Type Semantics: default

     ElementId: 454

     Status: current

     Reference: RFC 8038

12.  References

12.1.  Normative References

  [IANA-IPFIX]
             IANA, "IP Flow Information Export (IPFIX) Entities",
             <http://www.iana.org/assignments/ipfix/>.

  [RFC2119]  Bradner, S., "Key words for use in RFCs to Indicate
             Requirement Levels", BCP 14, RFC 2119,
             DOI 10.17487/RFC2119, March 1997,
             <http://www.rfc-editor.org/info/rfc2119>.

  [RFC2578]  McCloghrie, K., Ed., Perkins, D., Ed., and J.
             Schoenwaelder, Ed., "Structure of Management Information
             Version 2 (SMIv2)", STD 58, RFC 2578,
             DOI 10.17487/RFC2578, April 1999,
             <http://www.rfc-editor.org/info/rfc2578>.

  [RFC2856]  Bierman, A., McCloghrie, K., and R. Presuhn, "Textual
             Conventions for Additional High Capacity Data Types",
             RFC 2856, DOI 10.17487/RFC2856, June 2000,
             <http://www.rfc-editor.org/info/rfc2856>.

  [RFC3411]  Harrington, D., Presuhn, R., and B. Wijnen, "An
             Architecture for Describing Simple Network Management
             Protocol (SNMP) Management Frameworks", STD 62, RFC 3411,
             DOI 10.17487/RFC3411, December 2002,
             <http://www.rfc-editor.org/info/rfc3411>.




Aitken, et al.               Standards Track                   [Page 81]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


  [RFC6526]  Claise, B., Aitken, P., Johnson, A., and G. Muenz,
             "IP Flow Information Export (IPFIX) Per Stream Control
             Transmission Protocol (SCTP) Stream", RFC 6526,
             DOI 10.17487/RFC6526, March 2012,
             <http://www.rfc-editor.org/info/rfc6526>.

  [RFC7011]  Claise, B., Ed., Trammell, B., Ed., and P. Aitken,
             "Specification of the IP Flow Information Export (IPFIX)
             Protocol for the Exchange of Flow Information", STD 77,
             RFC 7011, DOI 10.17487/RFC7011, September 2013,
             <http://www.rfc-editor.org/info/rfc7011>.

  [RFC7012]  Claise, B., Ed., and B. Trammell, Ed., "Information Model
             for IP Flow Information Export (IPFIX)", RFC 7012,
             DOI 10.17487/RFC7012, September 2013,
             <http://www.rfc-editor.org/info/rfc7012>.

  [X.690]    International Telecommunication Union, "Information
             Technology - ASN.1 encoding rules: Specification of Basic
             Encoding Rules (BER), Canonical Encoding Rules (CER) and
             Distinguished Encoding Rules (DER)", ITU-T Recommendation
             X.690, ISO/IEC 8825-1, August 2015,
             <https://www.itu.int/rec/T-REC-X.690>.

12.2.  Informative References

  [CISCO-PROCESS-MIB]
             Cisco Systems Inc., "CISCO-PROCESS-MIB.my: MIB for CPU and
             process statistics", <ftp://ftp.cisco.com/pub/mibs/v2/
             CISCO-PROCESS-MIB.my>.

  [RFC2863]  McCloghrie, K. and F. Kastenholz, "The Interfaces Group
             MIB", RFC 2863, DOI 10.17487/RFC2863, June 2000,
             <http://www.rfc-editor.org/info/rfc2863>.

  [RFC2982]  Kavasseri, R., Ed., "Distributed Management Expression
             MIB", RFC 2982, DOI 10.17487/RFC2982, October 2000,
             <http://www.rfc-editor.org/info/rfc2982>.

  [RFC3414]  Blumenthal, U. and B. Wijnen, "User-based Security Model
             (USM) for version 3 of the Simple Network Management
             Protocol (SNMPv3)", STD 62, RFC 3414,
             DOI 10.17487/RFC3414, December 2002,
             <http://www.rfc-editor.org/info/rfc3414>.







Aitken, et al.               Standards Track                   [Page 82]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


  [RFC3415]  Wijnen, B., Presuhn, R., and K. McCloghrie, "View-based
             Access Control Model (VACM) for the Simple Network
             Management Protocol (SNMP)", STD 62, RFC 3415,
             DOI 10.17487/RFC3415, December 2002,
             <http://www.rfc-editor.org/info/rfc3415>.

  [RFC3444]  Pras, A. and J. Schoenwaelder, "On the Difference between
             Information Models and Data Models", RFC 3444,
             DOI 10.17487/RFC3444, January 2003,
             <http://www.rfc-editor.org/info/rfc3444>.

  [RFC4022]  Raghunarayan, R., Ed., "Management Information Base for
             the Transmission Control Protocol (TCP)", RFC 4022,
             DOI 10.17487/RFC4022, March 2005,
             <http://www.rfc-editor.org/info/rfc4022>.

  [RFC4293]  Routhier, S., Ed., "Management Information Base for the
             Internet Protocol (IP)", RFC 4293, DOI 10.17487/RFC4293,
             April 2006, <http://www.rfc-editor.org/info/rfc4293>.

  [RFC4750]  Joyal, D., Ed., Galecki, P., Ed., Giacalone, S., Ed.,
             Coltun, R., and F. Baker, "OSPF Version 2 Management
             Information Base", RFC 4750, DOI 10.17487/RFC4750,
             December 2006, <http://www.rfc-editor.org/info/rfc4750>.

  [RFC4960]  Stewart, R., Ed., "Stream Control Transmission Protocol",
             RFC 4960, DOI 10.17487/RFC4960, September 2007,
             <http://www.rfc-editor.org/info/rfc4960>.

  [RFC5102]  Quittek, J., Bryant, S., Claise, B., Aitken, P., and J.
             Meyer, "Information Model for IP Flow Information Export",
             RFC 5102, DOI 10.17487/RFC5102, January 2008,
             <http://www.rfc-editor.org/info/rfc5102>.

  [RFC5476]  Claise, B., Ed., Johnson, A., and J. Quittek, "Packet
             Sampling (PSAMP) Protocol Specifications", RFC 5476,
             DOI 10.17487/RFC5476, March 2009,
             <http://www.rfc-editor.org/info/rfc5476>.

  [RFC5591]  Harrington, D. and W. Hardaker, "Transport Security Model
             for the Simple Network Management Protocol (SNMP)",
             STD 78, RFC 5591, DOI 10.17487/RFC5591, June 2009,
             <http://www.rfc-editor.org/info/rfc5591>.

  [RFC5592]  Harrington, D., Salowey, J., and W. Hardaker, "Secure
             Shell Transport Model for the Simple Network Management
             Protocol (SNMP)", RFC 5592, DOI 10.17487/RFC5592,
             June 2009, <http://www.rfc-editor.org/info/rfc5592>.



Aitken, et al.               Standards Track                   [Page 83]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


  [RFC6235]  Boschi, E. and B. Trammell, "IP Flow Anonymization
             Support", RFC 6235, DOI 10.17487/RFC6235, May 2011,
             <http://www.rfc-editor.org/info/rfc6235>.

  [RFC6313]  Claise, B., Dhandapani, G., Aitken, P., and S. Yates,
             "Export of Structured Data in IP Flow Information Export
             (IPFIX)", RFC 6313, DOI 10.17487/RFC6313, July 2011,
             <http://www.rfc-editor.org/info/rfc6313>.

  [RFC6353]  Hardaker, W., "Transport Layer Security (TLS) Transport
             Model for the Simple Network Management Protocol (SNMP)",
             STD 78, RFC 6353, DOI 10.17487/RFC6353, July 2011,
             <http://www.rfc-editor.org/info/rfc6353>.

Acknowledgments

  The authors would like to thank Andrew Johnson for his collaboration
  on the first draft version of this document, and to thank Andrew
  Feren and Brian Trammell for their detailed reviews.

  Juergen Schoenwaelder was partly funded by Flamingo, a Network of
  Excellence project (ICT-318488) supported by the European Commission
  under its Seventh Framework Programme.

Authors' Addresses

  Paul Aitken (editor)
  Brocade Communications Systems, Inc.
  19a Canning Street, Level 3
  Edinburgh, Scotland  EH3 8EG
  United Kingdom

  Phone: +44 203 005 0731
  Email: [email protected]


  Benoit Claise
  Cisco Systems, Inc.
  De Kleetlaan 6a b1
  Diegem  1813
  Belgium

  Phone: +32 2 704 5622
  Email: [email protected]







Aitken, et al.               Standards Track                   [Page 84]

RFC 8038           Exporting MIB Variables with IPFIX           May 2017


  Srikar B S
  Mojo Networks, Inc.
  S. No. 7, Pinnac House II
  Kothrud, Pune  411038
  India

  Phone: +91 94 4847 6672
  Email: [email protected]


  Colin McDowall
  Brocade Communications Systems, Inc.
  19a Canning Street, Level 3
  Edinburgh, Scotland  EH3 8EG
  United Kingdom

  Phone: +44 203 005 0687
  Email: [email protected]


  Juergen Schoenwaelder
  Jacobs University Bremen
  Campus Ring 1
  Bremen  28725
  Germany

  Phone: +49 421 200 3587
  Email: [email protected]























Aitken, et al.               Standards Track                   [Page 85]