Internet Engineering Task Force (IETF)                     T. Dietz, Ed.
Request for Comments: 6615                               NEC Europe Ltd.
Obsoletes: 5815                                             A. Kobayashi
Category: Standards Track                                    NTT PF Labs
ISSN: 2070-1721                                                B. Claise
                                                    Cisco Systems, Inc.
                                                               G. Muenz
                                       Technische Universitaet Muenchen
                                                              June 2012


    Definitions of Managed Objects for IP Flow Information Export

Abstract

  This document defines managed objects for IP Flow Information eXport
  (IPFIX).  These objects provide information for monitoring IPFIX
  Exporters and IPFIX Collectors, including basic configuration
  information.

Status of This Memo

  This is an Internet Standards Track document.

  This document is a product of the Internet Engineering Task Force
  (IETF).  It represents the consensus of the IETF community.  It has
  received public review and has been approved for publication by the
  Internet Engineering Steering Group (IESG).  Further information on
  Internet Standards is available in Section 2 of RFC 5741.

  Information about the current status of this document, any errata,
  and how to provide feedback on it may be obtained at
  http://www.rfc-editor.org/info/rfc6615.

Copyright Notice

  Copyright (c) 2012 IETF Trust and the persons identified as the
  document authors.  All rights reserved.

  This document is subject to BCP 78 and the IETF Trust's Legal
  Provisions Relating to IETF Documents
  (http://trustee.ietf.org/license-info) in effect on the date of
  publication of this document.  Please review these documents
  carefully, as they describe your rights and restrictions with respect
  to this document.  Code Components extracted from this document must
  include Simplified BSD License text as described in Section 4.e of
  the Trust Legal Provisions and are provided without warranty as
  described in the Simplified BSD License.



Dietz, et al.                Standards Track                    [Page 1]

RFC 6615                        IPFIX MIB                      June 2012


Table of Contents

  1. Introduction ....................................................3
  2. IPFIX Documents Overview ........................................3
  3. The Internet-Standard Management Framework ......................4
  4. Terminology .....................................................4
  5. Structure of the IPFIX MIB ......................................4
     5.1. The Transport Session Table ................................4
     5.2. The Template Table .........................................7
     5.3. The Template Definition Table ..............................9
     5.4. The Export Table ..........................................11
     5.5. The Metering Process Table ................................13
     5.6. The Observation Point Table ...............................14
     5.7. The Selection Process Table ...............................15
     5.8. The Statistical Tables ....................................16
          5.8.1. The Transport Session Statistical Table ............16
          5.8.2. The Template Statistical Table .....................16
          5.8.3. The Metering Process Statistical Table .............16
          5.8.4. The Selection Process Statistical Table ............16
  6. Structure of the IPFIX SELECTOR MIB ............................16
     6.1. The Selector Functions ....................................17
  7. Relationship to Other MIB Modules ..............................19
     7.1. Relationship to the ENTITY MIB and Interfaces MIB .........19
     7.2. MIB Modules Required for IMPORTS ..........................19
  8. MIB Definitions ................................................20
     8.1. IPFIX MIB Definition ......................................20
     8.2. IPFIX SELECTOR MIB Definition .............................56
  9. Security Considerations ........................................60
  10. IANA Considerations ...........................................61
  11. Acknowledgments ...............................................62
  12. References ....................................................62
     12.1. Normative References .....................................62
     12.2. Informative References ...................................63


















Dietz, et al.                Standards Track                    [Page 2]

RFC 6615                        IPFIX MIB                      June 2012


1.  Introduction

  This document defines two MIB modules for monitoring IP Flow
  Information eXport (IPFIX) Devices, including Exporters and
  Collectors.  While most of the objects defined by the IPFIX MIB
  module must be implemented, some objects may be implemented
  corresponding to the functionality implemented in the equipment.
  Since the IPFIX architecture [RFC5470] foresees the possibility of
  using Filtering and/or Sampling functions to reduce the data volume,
  this document also provides the IPFIX SELECTOR MIB module, which
  contains the standardized selection methods and is controlled by
  IANA.  The full configuration of the IPFIX Metering Process is out of
  the scope of these MIB modules.

  The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
  "SHOULD", "SHOULD NOT", "RECOMMENDED", "NOT RECOMMENDED", "MAY", and
  "OPTIONAL" in this document are to be interpreted as described in
  RFC 2119 [RFC2119].

2.  IPFIX Documents Overview

  The IPFIX protocol provides network administrators with access to IP
  Flow information.  The architecture for the export of measured IP
  Flow information out of an IPFIX Exporting Process to a Collecting
  Process is defined in [RFC5470], per the requirements defined in
  [RFC3917].  The protocol document [RFC5101] specifies how IPFIX Data
  Records and Templates are carried via a congestion-aware transport
  protocol from IPFIX Exporting Processes to IPFIX Collecting
  Processes.  IPFIX has a formal description of IPFIX Information
  Elements -- their name, type, and additional semantic information --
  as specified in [RFC5102].  Finally, [RFC5472] describes what type of
  applications can use the IPFIX protocol and how they can use the
  information provided.  It furthermore shows how the IPFIX framework
  relates to other architectures and frameworks.

  It is assumed that Flow metering, export, and collection are
  performed according to the IPFIX architecture defined in [RFC5470].
  The monitored configuration parameters of the export and collection
  of Flow Templates and Data Records are modeled according to
  [RFC5101].  Packet selection methods that may be optionally used by
  the IPFIX Metering Process are not considered in this MIB document.
  They are defined in the Packet Sampling (PSAMP) framework [RFC5474]
  and Sampling techniques [RFC5475] documents.  Nevertheless, the basis
  for defining Sampling and Filtering functions is given with the IPFIX
  SELECTOR MIB module.  Since the PSAMP export protocol [RFC5476] is
  based on the IPFIX protocol, the Sampling and Filtering functions can
  be added to the IPFIX SELECTOR MIB module as needed.




Dietz, et al.                Standards Track                    [Page 3]

RFC 6615                        IPFIX MIB                      June 2012


3.  The Internet-Standard Management Framework

  For a detailed overview of the documents that describe the current
  Internet-Standard Management Framework, please refer to section 7 of
  RFC 3410 [RFC3410].

  Managed objects are accessed via a virtual information store, termed
  the Management Information Base or MIB.  MIB objects are generally
  accessed through the Simple Network Management Protocol (SNMP).
  Objects in the MIB are defined using the mechanisms defined in the
  Structure of Management Information (SMI).  This memo specifies MIB
  modules that are compliant to the SMIv2, which is described in
  STD 58, RFC 2578 [RFC2578], STD 58, RFC 2579 [RFC2579] and STD 58,
  RFC 2580 [RFC2580].

4.  Terminology

  The definitions of basic terms such as IP Traffic Flow, Exporting
  Process, Collecting Process, Observation Points, etc. can be found in
  the IPFIX protocol document [RFC5101].

5.  Structure of the IPFIX MIB

  The IPFIX MIB module consists of seven main tables: the Transport
  Session table, the Template table and the corresponding Template
  Definition table, the Export table, the Metering Process table, the
  Observation Point table, and the Selection Process table.  Since the
  IPFIX architecture [RFC5470] foresees the possibility of using
  Filtering and/or Sampling functions to reduce the data volume, the
  IPFIX MIB module provides the basic objects for these functions with
  the Selection Process table.  The IPFIX SELECTOR MIB module, defined
  in the next section, provides the standard Filtering and Sampling
  functions that can be referenced in the ipfixSelectionProcessTable.

  All remaining objects contain statistical values for the different
  tables contained in the MIB module.

  The following subsections describe all tables in the IPFIX MIB
  module.

5.1.  The Transport Session Table

  The Transport Session is the basis of the MIB module.  The Transport
  Session table (ipfixTransportSessionTable) contains all Transport
  Sessions between the Exporter and Collector.  The table specifies the
  transport layer protocol of the Transport Session and, depending on
  that protocol, further parameters for the Transport Session.  In the
  case of UDP and TCP, these are the source and destination address as



Dietz, et al.                Standards Track                    [Page 4]

RFC 6615                        IPFIX MIB                      June 2012


  well as the source and destination port.  For the Stream Control
  Transmission Protocol (SCTP), the table contains
  ipfixTransportSessionSctpAssocId, which is the index for the SCTP
  association in the SCTP MIB module [RFC3873].  The mode of operation
  of the device, i.e., whether the Transport Session is used for
  collecting or exporting, is given in the
  ipfixTransportSessionDeviceMode object.  Further on, the table
  contains the configured refresh parameters for Templates and Options
  Templates that are used across unreliable connections such as UDP.
  Finally, the IPFIX version that is exported or collected by this
  Transport Session and a status of the Transport Session are given in
  the table.

  To illustrate the use of this table, let us assume the following
  scenario: we have an Exporter on IP address 192.0.2.22 and a
  Collector on IP address 192.0.2.37.  The Exporter uses TCP to export
  Templates and Data Records.  The same Exporter also exports, with
  UDP, to a Collector with the IP address of 192.0.2.44.  This would
  lead to the following Transport Session table on the Exporter:
































Dietz, et al.                Standards Track                    [Page 5]

RFC 6615                        IPFIX MIB                      June 2012


   ipfixTransportSessionTable (1)
   |
   +- ipfixTransportSessionEntry (1)
      |
      +- index (5) (ipfixTransportSessionIndex)
      |  +- ipfixTransportSessionIndex (1) = 5
      |  +- ipfixTransportSessionProtocol (2) = 6 (TCP)
      |  +- ipfixTransportSessionSourceAddressType (3) = 1 (ipv4)
      |  +- ipfixTransportSessionSourceAddress (4) = 192.0.2.22
      |  +- ipfixTransportSessionDestinationAddressType (5) = 1 (ipv4)
      |  +- ipfixTransportSessionDestinationAddress (6) = 192.0.2.37
      |  +- ipfixTransportSessionSourcePort (7) = 7653
      |  +- ipfixTransportSessionDestinationPort (8) = 4739
      |  +- ipfixTransportSessionSctpAssocId (9) = 0
      |  +- ipfixTransportSessionDeviceMode (10) = exporting(1)
      |  +- ipfixTransportSessionTemplateRefreshTimeout (11) = 0
      |  +- ipfixTransportSessionOptionsTemplateRefreshTimeout (12) = 0
      |  +- ipfixTransportSessionTemplateRefreshPacket (13) = 0
      |  +- ipfixTransportSessionOptionsTemplateRefreshPacket (14) = 0
      |  +- ipfixTransportSessionIpfixVersion (15) = 10
      |  +- ipfixTransportSessionStatus (16) = 2 (active)
      .
      .
      .
      +- index (11) (ipfixTransportSessionIndex)
         +- ipfixTransportSessionIndex (1) = 11
         +- ipfixTransportSessionProtocol (2) = 17 (UDP)
         +- ipfixTransportSessionSourceAddressType (3) = 1 (ipv4)
         +- ipfixTransportSessionSourceAddress (4) = 192.0.2.22
         +- ipfixTransportSessionDestinationAddressType (5) = 1 (ipv4)
         +- ipfixTransportSessionDestinationAddress (6) = 192.0.2.44
         +- ipfixTransportSessionSourcePort (7) = 14287
         +- ipfixTransportSessionDestinationPort (8) = 4739
         +- ipfixTransportSessionSctpAssocId (9) = 0
         +- ipfixTransportSessionDeviceMode (10) = exporting(1)
         +- ipfixTransportSessionTemplateRefreshTimeout (11) = 100
         +- ipfixTransportSessionOptionsTemplateRefreshTimeout (12)
         |                                                     = 100
         +- ipfixTransportSessionTemplateRefreshPacket (13) = 10
         +- ipfixTransportSessionOptionsTemplateRefreshPacket (14) = 10
         +- ipfixTransportSessionIpfixVersion (15) = 10
         +- ipfixTransportSessionStatus (16) = 2 (active)

  The values in parentheses are the OID numbers.  The Collectors would
  then have the same entry, except that the index would most likely
  differ and the ipfixTransportSessionDeviceMode value would be
  collecting(2).




Dietz, et al.                Standards Track                    [Page 6]

RFC 6615                        IPFIX MIB                      June 2012


5.2.  The Template Table

  The Template table lists all Templates (including Options Templates)
  that are sent (by an Exporter) or received (by a Collector).  The
  (Options) Templates are unique per Observation Domain and per
  Transport Session.  Note that the Transport Session also gives the
  device mode, i.e., Exporter or Collector.  Thus, the table is
  indexed by

  o  the Transport Session Index (ipfixTransportSessionIndex) and

  o  the Observation Domain ID (ipfixTemplateObservationDomainId).

  It contains the Set ID and an access time denoting the time when the
  (Options) Template was last sent or received.

  To resume the above example, the Exporter may want to export a
  Template and an Options Template for each Transport Session defined
  above.  This leads to the following Template table, which defines the
  Template and Options Template:































Dietz, et al.                Standards Track                    [Page 7]

RFC 6615                        IPFIX MIB                      June 2012


   ipfixTemplateTable (3)
   |
   +- ipfixTemplateEntry (1)
      |
      +- index (5) (ipfixTransportSessionIndex)
      |  +- index (3) (ipfixTemplateObservationDomainId)
      |     + index (257) (ipfixTemplateId)
      |     | +- ipfixTemplateObservationDomainId (1) = 3
      |     | +- ipfixTemplateId (2) = 257
      |     | +- ipfixTemplateSetId (3) = 2
      |     | +- ipfixTemplateAccessTime (4)
      |     |                             = 2008-7-1,12:49:11.2,+2:0
      |     |
      |     + index (264) (ipfixTemplateId)
      |       +- ipfixTemplateObservationDomainId (1) = 3
      |       +- ipfixTemplateId (2) = 264
      |       +- ipfixTemplateSetId (3) = 3
      |       +- ipfixTemplateAccessTime (4)
      .                                   = 2008-7-1,12:47:04.8,+2:0
      .
      .
      .
      +- index (11) (ipfixTransportSessionIndex)
         +- index (3) (ipfixTemplateObservationDomainId)
            + index (273) (ipfixTemplateId)
            | +- ipfixTemplateObservationDomainId (1) = 3
            | +- ipfixTemplateId (2) = 273
            | +- ipfixTemplateSetId (3) = 2
            | +- ipfixTemplateAccessTime (4)
            |                             = 2008-7-1,12:49:11.2,+2:0
            |
            + index (289) (ipfixTemplateId)
              +- ipfixTemplateObservationDomainId (1) = 3
              +- ipfixTemplateId (2) = 289
              +- ipfixTemplateSetId (3) = 3
              +- ipfixTemplateAccessTime (4)
                                          = 2008-7-1,12:47:04.8,+2:0

  We assume that the Transport Session that is stored with index 5 in
  the Transport Session table of the Exporter is stored with index 17
  in the Transport Session table of the (corresponding) Collector.
  Then, the Template table would look as follows:









Dietz, et al.                Standards Track                    [Page 8]

RFC 6615                        IPFIX MIB                      June 2012


   ipfixTemplateTable (3)
   |
   +- ipfixTemplateEntry (1)
      |
      +- index (17) (ipfixTransportSessionIndex)
         +- index (3) (ipfixTemplateObservationDomainId)
            + index (257) (ipfixTemplateId)
            | +- ipfixTemplateObservationDomainId (1) = 3
            | +- ipfixTemplateId (2) = 257
            | +- ipfixTemplateSetId (3) = 2
            | +- ipfixTemplateAccessTime (4)
            |                             = 2008-7-1,12:49:11.8,+2:0
            |
            + index (264) (ipfixTemplateId)
              +- ipfixTemplateObservationDomainId (1) = 3
              +- ipfixTemplateId (2) = 264
              +- ipfixTemplateSetId (3) = 3
              +- ipfixTemplateAccessTime (4)
                                          = 2008-7-1,12:47:05.3,+2:0

  The table on the second Collector would be analogous to the one shown
  above.

5.3.  The Template Definition Table

  The Template Definition table lists all the Information Elements
  contained in a Template or Options Template.  Therefore, it has the
  same indexes as the corresponding Template table plus the Template
  ID.  Its own index denotes the order of the Information Element
  inside the Template.  Besides the Information Element ID and the
  length of the encoded value, the table contains the enterprise number
  for enterprise-specific Information Elements and flags for each
  Information Element.  The flags indicate whether the Information
  Element is used for scoping or as a Flow Key.

  To resume the above example again, the Exporter is configured to
  export the octets received and dropped at the Observation Point since
  the last export of these values.  In addition, it exports the start
  and end time of the Flow relative to the timestamp contained in the
  IPFIX header.  This leads to the following Template Definition table
  on the Exporter:










Dietz, et al.                Standards Track                    [Page 9]

RFC 6615                        IPFIX MIB                      June 2012


   ipfixTemplateDefinitionTable (4)
   |
   +- ipfixTemplateDefinitionEntry (1)
      |
      +- index (5) (ipfixTransportSessionIndex)
         +- index (3) (ipfixTemplateObservationDomainId)
            + index (257) (ipfixTemplateId)
              +- index (1) (ipfixTemplateDefinitionIndex)
              |  +- ipfixTemplateDefinitionIndex (1) = 1
              |  +- ipfixTemplateDefinitionIeId (2) = 158
              |  |                      (flowStartDeltaMicroseconds)
              |  +- ipfixTemplateDefinitionIeLength (3) = 4
              |  +- ipfixTemplateDefinitionEnterpriseNumber (4) = 0
              |  +- ipfixTemplateDefinitionFlags (5) = 0
              |
              +- index (2) (ipfixTemplateDefinitionIndex)
              |  +- ipfixTemplateDefinitionIndex (1) = 2
              |  +- ipfixTemplateDefinitionIeId (2) = 159
              |  |                      (flowEndDeltaMicroseconds)
              |  +- ipfixTemplateDefinitionIeLength (3) = 4
              |  +- ipfixTemplateDefinitionEnterpriseNumber (4) = 0
              |  +- ipfixTemplateDefinitionFlags (5) = 0
              |
              +- index (3) (ipfixTemplateDefinitionIndex)
              |  +- ipfixTemplateDefinitionIndex (1) = 3
              |  +- ipfixTemplateDefinitionIeId (2) = 1
              |  |                                 (octetDeltaCount)
              |  +- ipfixTemplateDefinitionIeLength (3) = 8
              |  +- ipfixTemplateDefinitionEnterpriseNumber (4) = 0
              |  +- ipfixTemplateDefinitionFlags (5) = 0
              |
              +- index (4) (ipfixTemplateDefinitionIndex)
                 +- ipfixTemplateDefinitionIndex (1) = 4
                 +- ipfixTemplateDefinitionIeId (2) = 132
                 |                          (droppedOctetDeltaCount)
                 +- ipfixTemplateDefinitionIeLength (3) = 8
                 +- ipfixTemplateDefinitionEnterpriseNumber (4) = 0
                 +- ipfixTemplateDefinitionFlags (5) = 0

  The corresponding table entry on the Collector is the same, except
  that it would have another ipfixTransportSessionIndex, e.g., 17 as in
  the previous example.









Dietz, et al.                Standards Track                   [Page 10]

RFC 6615                        IPFIX MIB                      June 2012


5.4.  The Export Table

  On Exporters, the Export table (ipfixExportTable) can be used to
  support features like failover, load-balancing, duplicate export to
  several Collectors, etc.  The table has three indexes that link an
  entry with

  o  the Metering Process table (ipfixMeteringProcessCacheId; see
     below) and

  o  the Transport Session table (ipfixTransportSessionIndex).

  Those entries with the same ipfixExportIndex and the same
  ipfixMeteringProcessCacheId define a Transport Session group.  The
  member type for each group member describes its functionality.  All
  Transport Sessions referenced in this table MUST have a
  ipfixTransportSessionDeviceMode value of exporting(1).

  If the Exporter does not use Transport Session grouping, then each
  ipfixExportIndex contains a single ipfixMeteringProcessCacheId, and
  thus a single Transport Session (ipfixTransportSessionIndex); this
  session MUST have a member type value of primary(1).

  For failover, a Transport Session group can contain one Transport
  Session with member type primary(1) and several Transport Sessions
  with type secondary(2).  Entries with other member types are not
  allowed for that type of group.  For load-balancing or parallel
  export, all Transport Sessions in the group MUST have the same member
  type -- either loadBalancing(4) or parallel(3).

  The algorithms used for failover or load-balancing are out of the
  scope of this document.

  To continue the example, we assume that the Exporter uses the two
  connections shown in the examples above as one primary Transport
  Session protected by a secondary Transport Session.  The Exporter
  then has the following entries in the ipfixExportTable:














Dietz, et al.                Standards Track                   [Page 11]

RFC 6615                        IPFIX MIB                      June 2012


   ipfixExportTable (5)
   |
   +- ipfixExportEntry (1)
      |
      +- index (7) (ipfixExportIndex)
      |  +- index (9) (ipfixMeteringProcessCacheId)
      |     |  +- index (5) (ipfixTransportSessionIndex)
      |        |  +- ipfixExportIndex (1) = 7
      |        |  +- ipfixExportMemberType (2) = 1 (primary)
      |        |
      |        +- index (11) (ipfixTransportSessionIndex)
      |           +- ipfixExportIndex (1) = 7
      |           +- ipfixExportMemberType (2) = 2 (secondary)
      |
      +- index (8) (ipfixExportIndex)
         +- index (9) (ipfixMeteringProcessCacheId)
            +- index (5) (ipfixTransportSessionIndex)
            |  +- ipfixExportIndex (1) = 8
            |  +- ipfixExportMemberType (2) = 2 (secondary)
            +- index (11) (ipfixTransportSessionIndex)
               +- ipfixExportIndex (1) = 8
               +- ipfixExportMemberType (2) = 1 (primary)

  The example shows that the Exporter uses the Metering Process cache
  (index (9)), explained below, to export IPFIX Data Records for
  Transport Sessions 5 and 11.  Templates 257 and 264 defined above are
  exported within Transport Session 5 as primary, while the secondary
  Transport Session is 11.  Templates 273 and 289 are exported within
  Transport Session 11 as primary, while the secondary Transport
  Session is 5.

  Here are the steps required by a manager in order to understand what
  the backups are (if any) for Template Records exported from a
  specific Exporter to a specific Collector:

  1.  Look up the Collector IP address in the
      ipfixTransportSessionDestinationAddress object (in the
      ipfixTransportSessionTable).

  2.  From the same row, double-check the Exporter IP address in the
      ipfixTransportSessionSourceAddress object.

  3.  From the same row, write down the ipfixTransportSessionIndex
      value.







Dietz, et al.                Standards Track                   [Page 12]

RFC 6615                        IPFIX MIB                      June 2012


  4.  Use that ipfixTransportSessionIndex value in the
      ipfixTemplateTable and look up the pairs of
      (ipfixTemplateObservationDomainId, ipfixTemplateId).  From there,
      the manager deduces the Template Record(s) (ipfixTemplateId),
      exported from the Observation Domain(s)
      (ipfixTemplateObservationDomainId) on the tracked Exporter
      (ipfixTransportSessionSourceAddress) to the tracked Collector
      (ipfixTransportSessionDestinationAddress).

  5.  Reusing the same ipfixTransportSessionIndex in the
      ipfixExportTable, look in the table for a value of
      ipfixExportMemberType that equals "primary".  Note that there
      could be multiple entries for which the ipfixExportMemberType
      equals "primary" in the ipfixExportTable, so multiple iterations
      might be required until the correct value of
      ipfixTransportSessionIndex is found.

  6.  From the same row, write down the ipfixExportIndex value.

  7.  In the ipfixExportTable, under the same three index values
      (ipfixExportIndex, ipfixMeteringProcessCacheId, and
      ipfixTransportSessionIndex), look up the entries for which
      ipfixExportMemberType is different than "primary".  Write down
      the associated ipfixTransportSessionIndex value.

  8.  From the ipfixTransportSessionTable, look up the Transport
      Session details for this ipfixTransportSessionIndex value -- for
      example, the secondary Collector IP address and port
      (ipfixTransportSessionDestinationAddress and
      ipfixTransportSessionSourcePort).

5.5.  The Metering Process Table

  The Metering Process, as defined in [RFC5101], consists of a set of
  functions.  Maintaining the Flow Records is one of them.  This
  function is responsible for passing the Flow Records to the Exporting
  Process and also for detecting Flow expiration.  The Flow Records
  that are maintained by the Metering Process can be grouped by the
  Observation Points at which they are observed.  The instance that
  maintains such a group of Flow Records is a kind of cache.  For this
  reason, the Metering Process table (ipfixMeteringProcessTable) is
  indexed by cache IDs (ipfixMeteringProcessCacheId).  Each cache can
  be maintained by a separate instance of the Metering Process.  To
  specify the Observation Point(s) where the Flow Records are gathered,
  the ipfixMeteringProcessObservationPointGroupRef may contain an
  ipfixObservationPointGroupId from the Observation Point table
  (ipfixObservationPointTable), which is described in the next
  subsection.  If an Observation Point is not specified for the Flow



Dietz, et al.                Standards Track                   [Page 13]

RFC 6615                        IPFIX MIB                      June 2012


  Records, the ipfixMeteringProcessObservationPointGroupRef MUST be
  zero(0).  The timeouts (ipfixMeteringProcessCacheActiveTimeout and
  ipfixMeteringProcessCacheIdleTimeout) specify when Flows are expired.

   ipfixMeteringProcessTable (6)
   |
   +- ipfixMeteringProcessEntry (1)
      |
      +- index (9) (ipfixMeteringProcessCacheId)
         +- ipfixMeteringProcessCacheId (1) = 9
         +- ipfixMeteringProcessObservationPointGroupRef (2) = 17
         +- ipfixMeteringProcessCacheActiveTimeout (3) = 100
         +- ipfixMeteringProcessCacheIdleTimeout (4) = 100

5.6.  The Observation Point Table

  The Observation Point table (ipfixObservationPointTable) groups
  Observation Points with the ipfixObservationPointGroupId.  Each entry
  contains the Observation Domain ID in which the Observation Point is
  located and a reference to the ENTITY MIB module [RFC4133] or the
  Interfaces MIB module [RFC2863].  The objects in the ENTITY MIB
  module referenced by ipfixObservationPointPhysicalEntity, or the
  objects in the Interfaces MIB module referenced by
  ipfixObservationPointPhysicalInterface, denote the Observation Point.
  At least one reference for the objects
  ipfixObservationPointPhysicalEntity or
  ipfixObservationPointPhysicalInterface MUST exist for a valid
  Observation Point entry.  If a reference to the Observation Point is
  given in both object ipfixObservationPointPhysicalEntity and
  ipfixObservationPointPhysicalInterface, then both MUST point to the
  same physical interface.  However, if one of two references
  (ipfixObservationPointPhysicalEntity or
  ipfixObservationPointPhysicalInterface) cannot be given, its
  reference MUST be 0.  In addition, a direction can be given to render
  more specifically which Flow to monitor.
















Dietz, et al.                Standards Track                   [Page 14]

RFC 6615                        IPFIX MIB                      June 2012


   ipfixObservationPointTable (7)
   |
   +- ipfixObservationPointEntry (1)
      |
      +- index (17) (ipfixObservationPointGroupId)
         +- index (1) (ipfixObservationPointIndex)
         |  +- ipfixObservationPointGroupId (1) = 17
         |  +- ipfixObservationPointIndex (2) = 1
         |  +- ipfixObservationPointObservationDomainId (3) = 3
         |  +- ipfixObservationPointPhysicalEntity (4) = 6
         |  +- ipfixObservationPointPhysicalInterface(5) = 0
         |  +- ipfixObservationPointPhysicalEntityDirection (6)
                                                            = 3 (both)
         |
         +- index (2) (ipfixObservationPointIndex)
            +- ipfixObservationPointGroupId (1) = 17
            +- ipfixObservationPointIndex (2) = 2
            +- ipfixObservationPointObservationDomainId (3) = 3
            +- ipfixObservationPointPhysicalEntity (4) = 0
            +- ipfixObservationPointPhysicalInterface (5) = 0
            +- ipfixObservationPointPhysicalEntityDirection (6)
                                                          = 1 (ingress)

5.7.  The Selection Process Table

  This table supports the usage of Filtering and Sampling functions, as
  described in [RFC5470].  It contains lists of functions per Metering
  Process cache (ipfixMeteringProcessCacheId).  The selection process
  index ipfixSelectionProcessIndex forms groups of selection methods
  that are applied to an observed packet stream.  The selection process
  selector index (ipfixSelectionProcessSelectorIndex) indicates the
  order in which the functions are applied to the packets observed at
  the Observation Points associated with the Metering Process cache.
  The selection methods are applied in increasing order; i.e.,
  selection methods with a lower ipfixSelectionProcessSelectorIndex are
  applied first.  The functions are referenced by object identifiers
  pointing to each function with its parameters.  If the selection
  method does not use parameters, then it MUST point to the root of the
  function subtree (see also Section 6).  If the function uses
  parameters, then it MUST point to an entry in the parameter table of
  the selection method.  If no Filtering or Sampling function is used
  for a Metering Process, then an entry for the Metering Process SHOULD
  be created that points to the Select All function
  (ipfixFuncSelectAll).







Dietz, et al.                Standards Track                   [Page 15]

RFC 6615                        IPFIX MIB                      June 2012


5.8.  The Statistical Tables

  Statistical tables that augment the ipfixTransportSessionTable,
  ipfixTemplateTable, ipfixMeteringProcessTable, and
  ipfixSelectionProcessTable have been defined.  All the statistical
  tables contain a discontinuity object that holds a timestamp denoting
  the time when a discontinuity event occurred, in order to notify the
  management system that the counters contained in those tables might
  not be continuous anymore.

5.8.1.  The Transport Session Statistical Table

  The Transport Session Statistical table
  (ipfixTransportSessionStatsTable) augments the
  ipfixTransportSessionTable with statistical values.  It contains the
  rate (in bytes per second) at which it receives or sends out IPFIX
  Messages; the number of bytes, packets, messages, Records, Templates,
  and Options Templates received or sent; and the number of messages
  that were discarded.

5.8.2.  The Template Statistical Table

  This table contains a statistical value for each Template.  It
  augments the Template table (ipfixTemplateTable) and specifies the
  number of Data Records exported or collected for the Template.

5.8.3.  The Metering Process Statistical Table

  This table augments the Metering Process table
  (ipfixMeteringProcessTable).  It contains the statistical values for
  the exported Data Records and the number of unused cache entries.

5.8.4.  The Selection Process Statistical Table

  This table augments the Selection Process table
  (ipfixSelectionProcessTable) and introduces two generic statistical
  values: the number of packets observed and the number of packets
  dropped by the selection method.

6.  Structure of the IPFIX SELECTOR MIB

  The IPFIX SELECTOR MIB module defined in this section provides the
  standard Filtering and Sampling functions that can be referenced in
  the ipfixSelectionProcessTable.  All standard Filtering and Sampling
  functions MUST be registered in the subtree under object
  ipfixSelectorFunctions (iso.org.dod.internet.mgmt.mib-2.
  ipfixSelectorMIB.ipfixSelectorObjects.ipfixSelectorFunctions, or
  1.3.6.1.2.1.194.1.1).  The top-level OIDs in the subtree under object



Dietz, et al.                Standards Track                   [Page 16]

RFC 6615                        IPFIX MIB                      June 2012


  ipfixSelectorFunctions MUST be registered in a sub-registry
  maintained by IANA at http://www.iana.org/assignments/smi-numbers.
  The first entry in this subtree is the Select All function
  (ipfixFuncSelectAll), defined in this document as
  {ipfixSelectorFunctions 1}.

  New Selector Functions MUST be registered at IANA and are subject to
  Expert Review [RFC5226], i.e., review by one of a group of experts
  designated by an IETF Area Director.  The group of experts MUST check
  the requested MIB objects for completeness and accuracy of the
  description.  Requests for MIB objects that duplicate the
  functionality of existing objects SHOULD be declined.  The smallest
  available OID SHOULD be assigned to new MIB objects.  The
  specification of new MIB objects SHOULD follow the structure
  specified in Section 6.1 and MUST be published using a well-
  established and persistent publication medium.  The experts will
  initially be drawn from the Working Group Chairs and document editors
  of the IPFIX and PSAMP Working Groups.

6.1.  The Selector Functions

  The following figure shows what the MIB tree usually should look
  like.  It already contains ipfixFuncSelectAll.  The subtree in
  ipfixFuncF2 gives the basic structure that all selection methods
  SHOULD follow.

   ipfixSelectorFunctions
   |
   +- ipfixFuncSelectAll
   |  |
   |  +- ipfixFuncSelectAllAvail (is the function available?)
   |
   +- ipfixFuncF2
   |  |
   |  +- ipfixFuncF2Avail (is the function F2 available?)
   |  |
   |  +- ipfixFuncF2Parameters (a table with parameters)
   ...
   |
   +- ipfixFuncFn...

  The selection method SHOULD be designed as a MIB subtree introduced
  by an object with the name ipfixFunc appended by a function name.
  The objects in this subtree SHOULD be prefixed by this name.  If the
  function is named Fx, then we would start a subtree with an OID named
  ipfixFuncFx.  This subtree should contain an object ipfixFuncFxAvail
  that has the type TruthValue.  If a selection method takes
  parameters, the MIB should contain a table named



Dietz, et al.                Standards Track                   [Page 17]

RFC 6615                        IPFIX MIB                      June 2012


  ipfixFuncFxParameters, which should contain all the parameters that
  the selection method specifies.  An entry in this table will be
  referenced by the IPFIX MIB module if the selection method with the
  parameters is used.

  To illustrate the structure defined above, the following contains an
  example of a function MyFunc that holds three integer parameters
  Param1, Param2, and Param3.  In the example, there are currently two
  instances of the parameter sets, defined with indexes 1 and 4.

   ipfixSelectorFunctions (1)
   |
   +- ipfixFuncMyFunc (?)
      |
      +- ipfixFuncMyFuncAvail (1) = true
      +- ipfixFuncMyFuncParameters (2)
         |
         +- ipfixFuncMyFuncParametersEntry (1)
            |
            +- index (1) (ipfixFuncMyFuncParametersIndex)
            |  +- ipfixFuncMyFuncParam1 (1) = 47
            |  +- ipfixFuncMyFuncParam2 (2) = -128
            |  +- ipfixFuncMyFuncParam3 (3) = 19
            |
            +- index(4) (ipfixFuncMyFuncParametersIndex)
               +- ipfixFuncMyFuncParam1 (1) = 19
               +- ipfixFuncMyFuncParam2 (2) = -1
               +- ipfixFuncMyFuncParam3 (3) = 728

  If the function defined above is referenced in the IPFIX MIB module,
  the ipfixSelectionProcessTable would look as follows:

   ipfixSelectionProcessTable (8)
   |
   +- ipfixSelectionProcessEntry (1)
      |
      +- index (9) (ipfixMeteringProcessCacheId)
         +- index (1) (ipfixSelectionProcessIndex)
            +- index (1) (ipfixSelectionProcessSelectorIndex)
            |  +- ipfixSelectionProcessSelectorFunction (3)
            |                          = ipfixSelectorFunctions.?.2.1.4
            +- index (2) (ipfixSelectionProcessSelectorIndex)
               +- ipfixSelectionProcessSelectorFunction (3)
                                       = ipfixSelectorFunctions.?.2.1.1







Dietz, et al.                Standards Track                   [Page 18]

RFC 6615                        IPFIX MIB                      June 2012


  This means that for the ipfixMeteringProcessCacheId(9), a Selection
  Process with index 1 is created that applies the same function two
  times but with different parameter sets.  First, the function MyFunc
  is applied with the parameters of the set with index 4, and then with
  the parameters of the set with index 1.

7.  Relationship to Other MIB Modules

  Besides the usual imports from the SNMP Standards [RFC2578],
  [RFC2579], and [RFC2580], the IPFIX MIB module references the ENTITY
  MIB module [RFC4133] and the Interfaces MIB module [RFC2863].

7.1.  Relationship to the ENTITY MIB and Interfaces MIB

  The Observation Point table (ipfixObservationPointTable) contains a
  reference to the ENTITY MIB module [RFC4133]
  (ipfixObservationPointPhysicalEntity) and a reference to the
  Interfaces MIB module [RFC2863]
  (ipfixObservationPointPhysicalInterface).  If the implementers of the
  IPFIX MIB module want to specify the physical entity where Flows are
  observed, then they SHOULD also implement the ENTITY MIB and/or the
  Interfaces MIB module.  The implementation of the ENTITY MIB and/or
  the Interfaces MIB module is OPTIONAL.  If one of them is not
  implemented, then all values of the respective column
  ipfixObservationPointPhysicalEntity or
  ipfixObservationPointPhysicalInterface in the Observation Point table
  are zero and the values of the
  ipfixObservationPointPhysicalEntityDirection columns are unknown(0),
  if none of them are defined.

7.2.  MIB Modules Required for IMPORTS

  The IPFIX MIB module requires the modules SNMPv2-SMI [RFC2578],
  SNMPv2-TC [RFC2579], and SNMPv2-CONF [RFC2580].  Further on, it
  imports the textual conventions InetAddressType and InetAddress from
  the INET ADDRESS MIB module [RFC4001].

  The IPFIX SELECTOR MIB module also requires the modules SNMPv2-SMI
  [RFC2578], SNMPv2-TC [RFC2579], and SNMPv2-CONF [RFC2580].












Dietz, et al.                Standards Track                   [Page 19]

RFC 6615                        IPFIX MIB                      June 2012


8.  MIB Definitions

  This section contains the definitions of the IPFIX-MIB module and the
  IPFIX-SELECTOR-MIB module.  There are different mandatory groups
  defined for Collector and Exporter implementations.  The statistical
  objects are made OPTIONAL.

8.1.  IPFIX MIB Definition

  IPFIX-MIB DEFINITIONS ::= BEGIN

  IMPORTS
      MODULE-IDENTITY, OBJECT-TYPE, mib-2, Unsigned32, Counter64,
      Gauge32
          FROM SNMPv2-SMI                              -- [RFC2578]
      TimeStamp, DateAndTime
          FROM SNMPv2-TC                               -- [RFC2579]
      MODULE-COMPLIANCE, OBJECT-GROUP
          FROM SNMPv2-CONF                             -- [RFC2580]
      InterfaceIndexOrZero
          FROM IF-MIB                                  -- [RFC2863]
      InetAddressType, InetAddress, InetPortNumber
          FROM INET-ADDRESS-MIB                        -- [RFC4001]
      PhysicalIndexOrZero
          FROM ENTITY-MIB;                             -- [RFC4133]

  ipfixMIB MODULE-IDENTITY
      LAST-UPDATED "201206110000Z"         -- 11 June 2012
      ORGANIZATION "IETF IPFIX Working Group"
      CONTACT-INFO
          "WG charter:
            http://www.ietf.org/html.charters/ipfix-charter.html

          Mailing Lists:
            General Discussion: [email protected]
            To Subscribe: http://www1.ietf.org/mailman/listinfo/ipfix
            Archive:
        http://www1.ietf.org/mail-archive/web/ipfix/current/index.html

          Editor:
            Thomas Dietz
            NEC Europe Ltd.
            NEC Laboratories Europe
            Network Research Division
            Kurfuersten-Anlage 36
            Heidelberg  69115
            Germany




Dietz, et al.                Standards Track                   [Page 20]

RFC 6615                        IPFIX MIB                      June 2012


            Phone: +49 6221 4342-128
            Email: [email protected]

            Atsushi Kobayashi
            NTT Information Sharing Platform Laboratories
            3-9-11 Midori-cho
            Musashino-shi, Tokyo  180-8585
            Japan
            Phone: +81-422-59-3978
            Email: [email protected]

            Benoit Claise
            Cisco Systems, Inc.
            De Kleetlaan 6a b1
            Diegem  1831
            Belgium
            Phone:  +32 2 704 5622
            Email: [email protected]

            Gerhard Muenz
            Technische Universitaet Muenchen
            Department of Informatics
            Chair for Network Architectures and Services (I8)
            Boltzmannstr. 3
            Garching  85748
            Germany
            Email: [email protected]"

      DESCRIPTION
          "The IPFIX MIB defines managed objects for IP Flow
          Information eXport.  These objects provide information about
          managed nodes supporting the IPFIX protocol,
          for Exporters as well as for Collectors.

          Copyright (c) 2012 IETF Trust and the persons identified as
          authors of the code.  All rights reserved.

          Redistribution and use in source and binary forms, with or
          without modification, is permitted pursuant to, and subject
          to the license terms contained in, the Simplified BSD
          License set forth in Section 4.c of the IETF Trust's
          Legal Provisions Relating to IETF Documents
          (http://trustee.ietf.org/license-info)."

  --  Revision history

      REVISION     "201206110000Z"         -- 11 June 2012
      DESCRIPTION



Dietz, et al.                Standards Track                   [Page 21]

RFC 6615                        IPFIX MIB                      June 2012


          "Fixed errata from RFC 5815.  Published as RFC 6615."

      REVISION     "201004190000Z"         -- 19 April 2010
      DESCRIPTION
          "Initial version, published as RFC 5815."

      ::= { mib-2 193 }

  --******************************************************************
  -- Top-Level Structure of the MIB
  --******************************************************************

  ipfixObjects     OBJECT IDENTIFIER ::= { ipfixMIB 1 }
  ipfixConformance OBJECT IDENTIFIER ::= { ipfixMIB 2 }

  ipfixMainObjects OBJECT IDENTIFIER ::= { ipfixObjects 1 }
  ipfixStatistics  OBJECT IDENTIFIER ::= { ipfixObjects 2 }

  --==================================================================
  -- 1.1: Objects Used by All IPFIX Implementations
  --==================================================================
  --------------------------------------------------------------------
  -- 1.1.1: Transport Session Table
  --------------------------------------------------------------------
  ipfixTransportSessionTable  OBJECT-TYPE
      SYNTAX      SEQUENCE OF IpfixTransportSessionEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "This table lists the currently established Transport
          Sessions between an Exporting Process and a Collecting
          Process."
      ::= { ipfixMainObjects 1 }

  ipfixTransportSessionEntry OBJECT-TYPE
      SYNTAX      IpfixTransportSessionEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "Defines an entry in the ipfixTransportSessionTable."
      INDEX       { ipfixTransportSessionIndex }
      ::= { ipfixTransportSessionTable 1 }

  IpfixTransportSessionEntry ::=
      SEQUENCE {
         ipfixTransportSessionIndex                  Unsigned32,
         ipfixTransportSessionProtocol               Unsigned32,
         ipfixTransportSessionSourceAddressType      InetAddressType,



Dietz, et al.                Standards Track                   [Page 22]

RFC 6615                        IPFIX MIB                      June 2012


         ipfixTransportSessionSourceAddress          InetAddress,
         ipfixTransportSessionDestinationAddressType InetAddressType,
         ipfixTransportSessionDestinationAddress     InetAddress,
         ipfixTransportSessionSourcePort             InetPortNumber,
         ipfixTransportSessionDestinationPort        InetPortNumber,
         ipfixTransportSessionSctpAssocId            Unsigned32,
         ipfixTransportSessionDeviceMode             INTEGER,
         ipfixTransportSessionTemplateRefreshTimeout Unsigned32,
         ipfixTransportSessionOptionsTemplateRefreshTimeout Unsigned32,
         ipfixTransportSessionTemplateRefreshPacket  Unsigned32,
         ipfixTransportSessionOptionsTemplateRefreshPacket Unsigned32,
         ipfixTransportSessionIpfixVersion           Unsigned32,
         ipfixTransportSessionStatus                 INTEGER
      }

  ipfixTransportSessionIndex OBJECT-TYPE
      SYNTAX      Unsigned32 (1..4294967295)
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "Locally arbitrary, but unique identifier of an entry in
          the ipfixTransportSessionTable.  The value is expected to
          remain constant from a re-initialization of the entity's
          network management agent to the next re-initialization."
      ::= { ipfixTransportSessionEntry 1 }

  ipfixTransportSessionProtocol OBJECT-TYPE
      SYNTAX      Unsigned32 (1..255)
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The transport protocol used for receiving or transmitting
          IPFIX Messages.  Protocol numbers are assigned by IANA.  A
          current list of all assignments is available from
          <http://www.iana.org/assignments/protocol-numbers/>."
      REFERENCE
          "RFC 5101, Specification of the IP Flow Information Export
          (IPFIX) Protocol for the Exchange of IP Traffic Flow
          Information, Section 10."
      ::= { ipfixTransportSessionEntry 2 }

  ipfixTransportSessionSourceAddressType OBJECT-TYPE
      SYNTAX      InetAddressType { unknown(0), ipv4(1), ipv6 (2) }
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The type of address used for the source address,
          as specified in RFC 4001.  The InetAddressType supported



Dietz, et al.                Standards Track                   [Page 23]

RFC 6615                        IPFIX MIB                      June 2012


          values are ipv4(1) and ipv6(2).  This object is used with
          protocols (specified in ipfixTransportSessionProtocol) like
          TCP (6) and UDP (17) that have the notion of addresses.
          SCTP (132) should use the ipfixTransportSessionSctpAssocId
          instead.  If SCTP (132) or any other protocol without the
          notion of addresses is used, the object MUST be set to
          unknown(0)."
      ::= { ipfixTransportSessionEntry 3 }

  ipfixTransportSessionSourceAddress OBJECT-TYPE
      SYNTAX      InetAddress
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The source address of the Exporter of the IPFIX Transport
          Session.  This value is interpreted according to the value of
          ipfixTransportSessionAddressType, as specified in RFC 4001.
          This object is used with protocols (specified in
          ipfixTransportSessionProtocol) like TCP (6) and UDP (17) that
          have the notion of addresses.  SCTP (132) should use the
          ipfixTransportSessionSctpAssocId instead.  If SCTP (132) or
          any other protocol without the notion of addresses is used,
          the object MUST be set to a zero-length string."
      ::= { ipfixTransportSessionEntry 4 }

  ipfixTransportSessionDestinationAddressType OBJECT-TYPE
      SYNTAX      InetAddressType { unknown(0), ipv4(1), ipv6 (2) }
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The type of address used for the destination address,
          as specified in RFC 4001.  The InetAddressType supported
          values are ipv4(1) and ipv6(2).  This object is used with
          protocols (specified in ipfixTransportSessionProtocol) like
          TCP (6) and UDP (17) that have the notion of addresses.
          SCTP (132) should use the ipfixTransportSessionSctpAssocId
          instead.  If SCTP (132) or any other protocol without the
          notion of addresses is used, the object MUST be set to
          unknown(0)."
      ::= { ipfixTransportSessionEntry 5 }

  ipfixTransportSessionDestinationAddress OBJECT-TYPE
      SYNTAX      InetAddress
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The destination address of the Collector of the IPFIX
          Transport Session.  This value is interpreted according to



Dietz, et al.                Standards Track                   [Page 24]

RFC 6615                        IPFIX MIB                      June 2012


          the value of ipfixTransportSessionAddressType, as specified
          in RFC 4001.  This object is used with protocols
          (specified in ipfixTransportSessionProtocol) like TCP (6)
          and UDP (17) that have the notion of addresses.  SCTP (132)
          should use the ipfixTransportSessionSctpAssocId instead.
          If SCTP (132) or any other protocol without the notion of
          addresses is used, the object MUST be set to a zero-length
          string."
      ::= { ipfixTransportSessionEntry 6 }

  ipfixTransportSessionSourcePort OBJECT-TYPE
      SYNTAX      InetPortNumber
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The transport protocol port number of the Exporter.
          This object is used with protocols (specified in
          ipfixTransportSessionProtocol) like TCP (6)
          and UDP (17) that have the notion of ports.  SCTP (132)
          should copy the value of sctpAssocLocalPort if the
          Transport Session is in collecting mode or
          sctpAssocRemPort if the Transport Session is in
          exporting mode.  The association is referenced
          by the ipfixTransportSessionSctpAssocId.
          If any other protocol without the notion of
          ports is used, the object MUST be set to zero."
      ::= { ipfixTransportSessionEntry 7 }

  ipfixTransportSessionDestinationPort OBJECT-TYPE
      SYNTAX      InetPortNumber
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The transport protocol port number of the Collector.  The
          default value is 4739 for all currently defined transport
          protocol types.  This object is used with protocols
          (specified in ipfixTransportSessionProtocol) like TCP (6)
          and UDP (17) that have the notion of ports.  SCTP (132)
          should copy the value of sctpAssocRemPort if the
          Transport Session is in collecting mode or
          sctpAssocLocalPort if the Transport Session is in
          exporting mode.  The association is referenced
          by the ipfixTransportSessionSctpAssocId.
          If any other protocol without the notion of
          ports is used, the object MUST be set to zero."

      ::= { ipfixTransportSessionEntry 8 }




Dietz, et al.                Standards Track                   [Page 25]

RFC 6615                        IPFIX MIB                      June 2012


  ipfixTransportSessionSctpAssocId OBJECT-TYPE
      SYNTAX      Unsigned32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The association ID used for the SCTP session between the
          Exporter and the Collector of the IPFIX Transport Session.
          It is equal to the sctpAssocId entry in the sctpAssocTable
          defined in the SCTP MIB.  This object is only valid if
          ipfixTransportSessionProtocol has the value 132 (SCTP).  In
          all other cases, the value MUST be zero."
      REFERENCE
          "RFC 3873, Stream Control Transmission Protocol (SCTP)
          Management Information Base (MIB)."
      ::= { ipfixTransportSessionEntry 9 }

  ipfixTransportSessionDeviceMode OBJECT-TYPE
      SYNTAX      INTEGER {
                      exporting(1),
                      collecting(2)
                  }
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The mode of operation of the device for the given Transport
          Session.  This object can have the following values:

          exporting(1)
              This value MUST be used if the Transport Session is
              used for exporting Records to other IPFIX Devices;
              i.e., this device acts as Exporter.

          collecting(2)
              This value MUST be used if the Transport Session is
              used for collecting Records from other IPFIX Devices;
              i.e., this device acts as Collector."
      ::= { ipfixTransportSessionEntry 10 }

  ipfixTransportSessionTemplateRefreshTimeout OBJECT-TYPE
      SYNTAX      Unsigned32
      UNITS       "seconds"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "On Exporters, this object contains the time in seconds
          after which IPFIX Templates are resent by the
          Exporter.




Dietz, et al.                Standards Track                   [Page 26]

RFC 6615                        IPFIX MIB                      June 2012


          On Collectors, this object contains the lifetime in seconds
          after which a Template becomes invalid when it is not
          received again within this lifetime.

          This object is only valid if ipfixTransportSessionProtocol
          has the value 17 (UDP).  In all other cases, the value MUST
          be zero."
      REFERENCE
          "RFC 5101, Specification of the IP Flow Information Export
          (IPFIX) Protocol for the Exchange of IP Traffic Flow
          Information, Sections 10.3.6 and 10.3.7."
      ::= { ipfixTransportSessionEntry 11 }

  ipfixTransportSessionOptionsTemplateRefreshTimeout OBJECT-TYPE
      SYNTAX      Unsigned32
      UNITS       "seconds"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "On Exporters, this object contains the time in seconds
          after which IPFIX Options Templates are resent by the
          Exporter.

          On Collectors, this object contains the lifetime in seconds
          after which an Options Template becomes invalid when it is
          not received again within this lifetime.

          This object is only valid if ipfixTransportSessionProtocol
          has the value 17 (UDP).  In all other cases, the value MUST
          be zero."
      REFERENCE
          "RFC 5101, Specification of the IP Flow Information Export
          (IPFIX) Protocol for the Exchange of IP Traffic Flow
          Information, Sections 10.3.6 and 10.3.7."
      ::= { ipfixTransportSessionEntry 12 }

  ipfixTransportSessionTemplateRefreshPacket OBJECT-TYPE
      SYNTAX      Unsigned32
      UNITS       "packets"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "On Exporters, this object contains the number of exported
          IPFIX Messages after which IPFIX Templates are resent
          by the Exporter.






Dietz, et al.                Standards Track                   [Page 27]

RFC 6615                        IPFIX MIB                      June 2012


          On Collectors, this object contains the lifetime in number
          of exported IPFIX Messages after which a Template becomes
          invalid when it is not received again within this lifetime.

          This object is only valid if ipfixTransportSessionProtocol
          has the value 17 (UDP).  In all other cases, the value MUST
          be zero."
      REFERENCE
          "RFC 5101, Specification of the IP Flow Information Export
          (IPFIX) Protocol for the Exchange of IP Traffic Flow
          Information, Sections 10.3.6 and 10.3.7."
      ::= { ipfixTransportSessionEntry 13 }

  ipfixTransportSessionOptionsTemplateRefreshPacket OBJECT-TYPE
      SYNTAX      Unsigned32
      UNITS       "packets"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "On Exporters, this object contains the number of exported
          IPFIX Messages after which IPFIX Options Templates are
          resent by the Exporter.

          On Collectors, this object contains the lifetime in number
          of exported IPFIX Messages after which an Options Template
          becomes invalid when it is not received again within this
          lifetime.

          This object is only valid if ipfixTransportSessionProtocol
          has the value 17 (UDP).  In all other cases, the value MUST
          be zero."
      REFERENCE
          "RFC 5101, Specification of the IP Flow Information Export
          (IPFIX) Protocol for the Exchange of IP Traffic Flow
          Information, Sections 10.3.6 and 10.3.7."
      ::= { ipfixTransportSessionEntry 14 }

  ipfixTransportSessionIpfixVersion OBJECT-TYPE
      SYNTAX      Unsigned32 (0..65535)
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "On Exporters, the object contains the version number of the
          IPFIX protocol that the Exporter uses to export its data in
          this Transport Session.

          On Collectors, the object contains the version number of the
          IPFIX protocol it receives for this Transport Session.



Dietz, et al.                Standards Track                   [Page 28]

RFC 6615                        IPFIX MIB                      June 2012


          If IPFIX Messages of different IPFIX protocol versions are
          transmitted or received in this Transport Session, this
          object contains the maximum version number."
      REFERENCE
          "RFC 5101, Specification of the IP Flow Information Export
          (IPFIX) Protocol for the Exchange of IP Traffic Flow
          Information, Section 3.1."
      ::= { ipfixTransportSessionEntry 15 }

  ipfixTransportSessionStatus OBJECT-TYPE
      SYNTAX      INTEGER {
                      unknown(0),
                      inactive(1),
                      active(2)
                  }
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The status of a Transport Session.  This object can have the
          following values:

          unknown(0)
              This value MUST be used if the status of the
              Transport Session cannot be detected by the equipment.
              This value should be avoided as far as possible.

          inactive(1)
              This value MUST be used for Transport Sessions that
              are specified in the system but are not currently active.
              The value can be used, for example, for Transport
              Sessions that are backup (secondary) sessions in a
              Transport Session group.

          active(2)
              This value MUST be used for Transport Sessions that are
              currently active and transmitting or receiving data."
      ::= { ipfixTransportSessionEntry 16 }














Dietz, et al.                Standards Track                   [Page 29]

RFC 6615                        IPFIX MIB                      June 2012


  --------------------------------------------------------------------
  -- 1.1.2: Template Table
  --------------------------------------------------------------------
  ipfixTemplateTable  OBJECT-TYPE
      SYNTAX      SEQUENCE OF IpfixTemplateEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "This table lists the Templates and Options Templates that
          are transmitted by the Exporting Process or received by the
          Collecting Process.

          The table contains the Templates and Options Templates that
          are received or used for exporting data for a given
          Transport Session group and Observation Domain.

          Withdrawn or invalidated (Options) Templates MUST be removed
          from this table."
      ::= { ipfixMainObjects 2 }

  ipfixTemplateEntry OBJECT-TYPE
      SYNTAX      IpfixTemplateEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "Defines an entry in the ipfixTemplateTable."
      INDEX       {
          ipfixTransportSessionIndex,
          ipfixTemplateObservationDomainId,
          ipfixTemplateId
      }
      ::= { ipfixTemplateTable 1 }

  IpfixTemplateEntry ::=
      SEQUENCE {
          ipfixTemplateObservationDomainId Unsigned32,
          ipfixTemplateId                  Unsigned32,
          ipfixTemplateSetId               Unsigned32,
          ipfixTemplateAccessTime          DateAndTime
      }

  ipfixTemplateObservationDomainId OBJECT-TYPE
      SYNTAX      Unsigned32 (0..4294967295)
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "The ID of the Observation Domain for which this Template
          is defined.  This value is used when sending IPFIX Messages.



Dietz, et al.                Standards Track                   [Page 30]

RFC 6615                        IPFIX MIB                      June 2012


          The special value of 0 indicates that the Data Records
          exported with this (Options Template) cannot be applied to a
          single Observation Domain."
      REFERENCE
          "RFC 5101, Specification of the IP Flow Information Export
          (IPFIX) Protocol for the Exchange of IP Traffic Flow
          Information, Section 3.1."
      ::= { ipfixTemplateEntry 1 }

  ipfixTemplateId OBJECT-TYPE
      SYNTAX      Unsigned32 (256..65535)
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "This number indicates the Template ID in the IPFIX
          Message.  Values from 0 to 255 are not allowed for Template
          IDs."
      REFERENCE
          "RFC 5101, Specification of the IP Flow Information Export
          (IPFIX) Protocol for the Exchange of IP Traffic Flow
          Information, Section 3.4.1."
      ::= { ipfixTemplateEntry 2 }

  ipfixTemplateSetId OBJECT-TYPE
      SYNTAX      Unsigned32 (1..65535)
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "This number indicates the Set ID of the Template.  This
          object allows the Template type to be easily retrieved.

          Currently, there are two values defined.  The value 2 is
          used for Sets containing Template definitions.  The value 3
          is used for Sets containing Options Template definitions."
      REFERENCE
          "RFC 5101, Specification of the IP Flow Information Export
          (IPFIX) Protocol for the Exchange of IP Traffic Flow
          Information, Section 3.3.2."
      ::= { ipfixTemplateEntry 3 }

  ipfixTemplateAccessTime OBJECT-TYPE
      SYNTAX      DateAndTime
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "If the Transport Session is in exporting mode
          (ipfixTransportSessionDeviceMode) the time when this
          (Options) Template was last sent to the Collector(s).



Dietz, et al.                Standards Track                   [Page 31]

RFC 6615                        IPFIX MIB                      June 2012


          In the specific case of UDP as transport protocol, this
          time is used to know when a retransmission of the
          (Options) Template is needed.

          If the Transport Session is in collecting mode, this object
          contains the time when this (Options) Template was last
          received from the Exporter.  In the specific case of UDP as
          transport protocol, this time is used to know when this
          (Options) Template times out and thus is no longer valid."
      ::= { ipfixTemplateEntry 4 }

  --------------------------------------------------------------------
  -- 1.1.3: Exported Template Definition Table
  --------------------------------------------------------------------
  ipfixTemplateDefinitionTable  OBJECT-TYPE
      SYNTAX      SEQUENCE OF IpfixTemplateDefinitionEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "On Exporters, this table lists the (Options) Template fields
          of which a (Options) Template is defined.  It defines the
          (Options) Template given in the ipfixTemplateId specified in
          the ipfixTemplateTable.

          On Collectors, this table lists the (Options) Template fields
          of which a (Options) Template is defined.  It defines the
          (Options) Template given in the ipfixTemplateId specified in
          the ipfixTemplateTable."
      ::= { ipfixMainObjects 3 }

  ipfixTemplateDefinitionEntry OBJECT-TYPE
      SYNTAX      IpfixTemplateDefinitionEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "Defines an entry in the ipfixTemplateDefinitionTable."
      INDEX       {
          ipfixTransportSessionIndex,
          ipfixTemplateObservationDomainId,
          ipfixTemplateId,
          ipfixTemplateDefinitionIndex
      }
      ::= { ipfixTemplateDefinitionTable 1 }

  IpfixTemplateDefinitionEntry ::=
      SEQUENCE {
          ipfixTemplateDefinitionIndex            Unsigned32,
          ipfixTemplateDefinitionIeId             Unsigned32,



Dietz, et al.                Standards Track                   [Page 32]

RFC 6615                        IPFIX MIB                      June 2012


          ipfixTemplateDefinitionIeLength         Unsigned32,
          ipfixTemplateDefinitionEnterpriseNumber Unsigned32,
          ipfixTemplateDefinitionFlags            BITS
      }

  ipfixTemplateDefinitionIndex OBJECT-TYPE
      SYNTAX      Unsigned32 (1..65535)
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "The ipfixTemplateDefinitionIndex specifies the order in
          which the Information Elements are used in the (Options)
          Template Record.

          Since a Template Record can contain a maximum of 65535
          Information Elements, the index is limited to this value."
      REFERENCE
          "RFC 5101, Specification of the IP Flow Information Export
          (IPFIX) Protocol for the Exchange of IP Traffic Flow
          Information, Sections 3.4.1 and 3.4.2."
      ::= { ipfixTemplateDefinitionEntry 1 }

  ipfixTemplateDefinitionIeId OBJECT-TYPE
      SYNTAX      Unsigned32 (1..65535)
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "This indicates the Information Element ID at position
          ipfixTemplateDefinitionIndex in the (Options) Template
          ipfixTemplateId.  This implicitly specifies the data type
          of the Information Element.  The elements are registered
          at IANA.  A current list of assignments can be found at
          <http://www.iana.org/assignments/ipfix/>."
      REFERENCE
          "RFC 5101, Specification of the IP Flow Information Export
          (IPFIX) Protocol for the Exchange of IP Traffic Flow
          Information, Section 3.2.

          RFC 5102, Information Model for IP Flow Information Export."
      ::= { ipfixTemplateDefinitionEntry 2 }

  ipfixTemplateDefinitionIeLength OBJECT-TYPE
      SYNTAX      Unsigned32 (0..65535)
      MAX-ACCESS  read-only
      STATUS      current






Dietz, et al.                Standards Track                   [Page 33]

RFC 6615                        IPFIX MIB                      June 2012


      DESCRIPTION
          "This indicates the length of the Information Element ID at
          position ipfixTemplateDefinitionIndex in the (Options)
          Template ipfixTemplateId."
      REFERENCE
          "RFC 5101, Specification of the IP Flow Information Export
          (IPFIX) Protocol for the Exchange of IP Traffic Flow
          Information, Section 3.2.

          RFC 5102, Information Model for IP Flow Information Export."
      ::= { ipfixTemplateDefinitionEntry 3 }

  ipfixTemplateDefinitionEnterpriseNumber OBJECT-TYPE
      SYNTAX      Unsigned32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "IANA enterprise number of the authority defining the
          Information Element identifier in this Template Record.
          Enterprise numbers are assigned by IANA.  A current list of
          all assignments is available from
          <http://www.iana.org/assignments/enterprise-numbers/>.

          This object must be zero(0) for all standard Information
          Elements registered with IANA.  A current list of these
          elements is available from
          <http://www.iana.org/assignments/ipfix/>."
      REFERENCE
          "RFC 5101, Specification of the IP Flow Information Export
          (IPFIX) Protocol for the Exchange of IP Traffic Flow
          Information, Section 3.2.

          RFC 5102, Information Model for IP Flow Information Export."
      ::= { ipfixTemplateDefinitionEntry 4 }

  ipfixTemplateDefinitionFlags OBJECT-TYPE
      SYNTAX      BITS {
                      scope(0),
                      flowKey(1)
                  }
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "This bitmask indicates special attributes for the
          Information Element:

          scope(0)
              This Information Element is used for scope.



Dietz, et al.                Standards Track                   [Page 34]

RFC 6615                        IPFIX MIB                      June 2012


          flowKey(1)
              This Information Element is a Flow Key.

          Thus, we get the following values for an Information Element:

          If neither bit scope(0) nor bit flowKey(1) is set
              The Information Element is neither used for scoping nor
              as Flow Key.
          If only bit scope(0) is set
              The Information Element is used for scoping.
          If only bit flowKey(1) is set
              The Information Element is used as Flow Key.

          Both bit scope(0) and flowKey(1) MUST NOT be set at the same
          time.  This combination is not allowed."
      REFERENCE
          "RFC 5101, Specification of the IP Flow Information Export
          (IPFIX) Protocol for the Exchange of IP Traffic Flow
          Information, Sections 2 and 3.4.2.1.

          RFC 5102, Information Model for IP Flow Information Export."
      ::= { ipfixTemplateDefinitionEntry 5 }

  --------------------------------------------------------------------
  -- 1.1.4: Export Table
  --------------------------------------------------------------------
  ipfixExportTable  OBJECT-TYPE
      SYNTAX      SEQUENCE OF IpfixExportEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "This table lists all exports of an IPFIX Device.

          On Exporters, this table contains all exports grouped by
          Transport Session, Observation Domain ID, Template ID, and
          Metering Process represented by the
          ipfixMeteringProcessCacheId.  Thanks to the ipfixExportIndex,
          the exports can group one or more Transport Sessions to
          achieve a special functionality like failover management,
          load-balancing, etc.  The entries with the same
          ipfixExportIndex, ipfixObservationDomainId,
          and ipfixMeteringProcessCacheId define a Transport
          Session group.  If the Exporter does not use Transport
          Session grouping, then each ipfixExportIndex contains a
          single ipfixMeteringProcessCacheId, and thus a single
          Transport Session; this session MUST have a member type





Dietz, et al.                Standards Track                   [Page 35]

RFC 6615                        IPFIX MIB                      June 2012


          value of primary(1).  Transport Sessions referenced in this
          table MUST have a ipfixTransportSessionDeviceMode value of
          exporting(1).

          On Collectors, this table is not needed."
      ::= { ipfixMainObjects 4 }

  ipfixExportEntry OBJECT-TYPE
      SYNTAX      IpfixExportEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "Defines an entry in the ipfixExportTable."
      INDEX       {
          ipfixExportIndex,
          ipfixMeteringProcessCacheId,
          ipfixTransportSessionIndex
      }
      ::= { ipfixExportTable 1 }

  IpfixExportEntry ::=
      SEQUENCE {
         ipfixExportIndex      Unsigned32,
         ipfixExportMemberType INTEGER
      }

  ipfixExportIndex OBJECT-TYPE
      SYNTAX      Unsigned32 (1..4294967295)
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "Locally arbitrary, but unique identifier of an entry in
          the ipfixExportTable.  The value is expected
          to remain constant from a re-initialization of the entity's
          network management agent to the next re-initialization.

          A common ipfixExportIndex between two entries from this
          table indicates that there is a relationship between the
          Transport Sessions in ipfixTransportSessionIndex.  The type
          of relationship is expressed by the value of
          ipfixExportMemberType."
      ::= { ipfixExportEntry 1 }

  ipfixExportMemberType OBJECT-TYPE
      SYNTAX      INTEGER {
                      unknown(0),
                      primary(1),
                      secondary(2),



Dietz, et al.                Standards Track                   [Page 36]

RFC 6615                        IPFIX MIB                      June 2012


                      parallel(3),
                      loadBalancing(4)
                  }
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The type of member Transport Session in a Transport
          Session group (identified by the value of ipfixExportIndex,
          ipfixObservationDomainId, and ipfixMeteringProcessCacheId).
          The following values are valid:

          unknown(0)
              This value MUST be used if the status of the group
              membership cannot be detected by the equipment.  This
              value should be avoided as far as possible.

          primary(1)
              This value is used for a group member that is used as
              the primary target of an Exporter.  Other group members
              (with the same ipfixExportIndex and
              ipfixMeteringProcessCacheId) MUST NOT have the value
              primary(1) but MUST have the value secondary(2).
              This value MUST also be specified if the Exporter does
              not support Transport Session grouping.  In this case,
              the group contains only one Transport Session.

          secondary(2)
              This value is used for a group member that is used as a
              secondary target of an Exporter.  The Exporter will use
              one of the targets specified as secondary(2) within the
              same Transport Session group when the primary target is
              not reachable.

          parallel(3)
              This value is used for a group member that is used for
              duplicate exporting (i.e., all group members identified
              by the ipfixExportIndex are exporting the same Records
              in parallel).  This implies that all group members MUST
              have the same member type (i.e., parallel(3)).

          loadBalancing(4)
              This value is used for a group member that is used
              as one target for load-balancing.  This means that a
              Record is sent to one of the group members in this
              group identified by ipfixExportIndex.
              This implies that all group members MUST have the same
              member type (i.e., loadBalancing(4))."
      ::= { ipfixExportEntry 2 }



Dietz, et al.                Standards Track                   [Page 37]

RFC 6615                        IPFIX MIB                      June 2012


  --------------------------------------------------------------------
  -- 1.1.5: Metering Process Table
  --------------------------------------------------------------------
  ipfixMeteringProcessTable  OBJECT-TYPE
      SYNTAX      SEQUENCE OF IpfixMeteringProcessEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "This table lists so-called caches used at the Metering
          Process to store the metering data of Flows observed at
          the Observation Points given in the
          ipfixObservationPointGroupReference.  The table lists the
          timeouts that specify when the cached metering data is
          expired.

          On Collectors, the table is not needed."
      ::= { ipfixMainObjects 5 }

  ipfixMeteringProcessEntry OBJECT-TYPE
      SYNTAX      IpfixMeteringProcessEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "Defines an entry in the ipfixMeteringProcessTable."
      INDEX       { ipfixMeteringProcessCacheId }
      ::= { ipfixMeteringProcessTable 1 }

  IpfixMeteringProcessEntry ::=
      SEQUENCE {
          ipfixMeteringProcessCacheId              Unsigned32,
          ipfixMeteringProcessObservationPointGroupRef Unsigned32,
          ipfixMeteringProcessCacheActiveTimeout   Unsigned32,
          ipfixMeteringProcessCacheIdleTimeout Unsigned32
      }

  ipfixMeteringProcessCacheId OBJECT-TYPE
      SYNTAX      Unsigned32 (1..4294967295)
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "Locally arbitrary, but unique identifier of an entry in the
          ipfixMeteringProcessTable.  The value is expected to remain
          constant from a re-initialization of the entity's network
          management agent to the next re-initialization."
      ::= { ipfixMeteringProcessEntry 1 }






Dietz, et al.                Standards Track                   [Page 38]

RFC 6615                        IPFIX MIB                      June 2012


  ipfixMeteringProcessObservationPointGroupRef OBJECT-TYPE
      SYNTAX      Unsigned32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The Observation Point Group ID that links this table entry
          to the ipfixObservationPointTable.  The matching
          ipfixObservationPointGroupId in that table gives the
          Observation Points used in that cache.  If the Observation
          Points are unknown, the
          ipfixMeteringProcessObservationPointGroupRef MUST be zero."
      ::= { ipfixMeteringProcessEntry 2 }

  ipfixMeteringProcessCacheActiveTimeout OBJECT-TYPE
      SYNTAX      Unsigned32
      UNITS       "seconds"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "On the Exporter, this object contains the time after which a
          Flow is expired (and a Data Record for the Template is sent),
          even though packets matching this Flow are still received by
          the Metering Process.  If this value is 0, the Flow is not
          prematurely expired."
      REFERENCE
          "RFC 5470, Architecture for IP Flow Information Export,
          Section 5.1.1, item 3."
      ::= { ipfixMeteringProcessEntry 3 }

  ipfixMeteringProcessCacheIdleTimeout OBJECT-TYPE
      SYNTAX      Unsigned32
      UNITS       "seconds"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "On the Exporter, this object contains the time after which a
          Flow is expired (and a Data Record for the Template is sent)
          when no packets matching this Flow are received by the
          Metering Process for the given number of seconds.  If this
          value is zero, the Flow is expired immediately; i.e., a Data
          Record is sent for every packet received by the Metering
          Process."
      REFERENCE
          "RFC 5470, Architecture for IP Flow Information Export,
          Section 5.1.1, item 1"
      ::= { ipfixMeteringProcessEntry 4 }





Dietz, et al.                Standards Track                   [Page 39]

RFC 6615                        IPFIX MIB                      June 2012


  --------------------------------------------------------------------
  -- 1.1.6: Observation Point Table
  --------------------------------------------------------------------
  ipfixObservationPointTable  OBJECT-TYPE
      SYNTAX      SEQUENCE OF IpfixObservationPointEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "This table lists the Observation Points used within an
          Exporter by the Metering Process.  The index
          ipfixObservationPointGroupId groups Observation Points
          and is referenced in the Metering Process table.

          On Collectors, this table is not needed."
      ::= { ipfixMainObjects 6 }

  ipfixObservationPointEntry OBJECT-TYPE
      SYNTAX      IpfixObservationPointEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "Defines an entry in the ipfixObservationPointTable."
      INDEX       {
          ipfixObservationPointGroupId,
          ipfixObservationPointIndex
      }
      ::= { ipfixObservationPointTable 1 }

  IpfixObservationPointEntry ::=
      SEQUENCE {
          ipfixObservationPointGroupId           Unsigned32,
          ipfixObservationPointIndex             Unsigned32,
          ipfixObservationPointObservationDomainId Unsigned32,
          ipfixObservationPointPhysicalEntity    PhysicalIndexOrZero,
          ipfixObservationPointPhysicalInterface InterfaceIndexOrZero,
          ipfixObservationPointPhysicalEntityDirection INTEGER
      }

  ipfixObservationPointGroupId OBJECT-TYPE
      SYNTAX      Unsigned32 (1..4294967295)
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "Locally arbitrary, but unique identifier of an entry in the
          ipfixObservationPointTable.  The value is expected to remain
          constant from a re-initialization of the entity's network
          management agent to the next re-initialization.




Dietz, et al.                Standards Track                   [Page 40]

RFC 6615                        IPFIX MIB                      June 2012


          This index represents a group of Observation Points.

          The special value of 0 MUST NOT be used within this table
          but is reserved for usage in the ipfixMeteringProcessTable.
          An index of 0 for the ipfixObservationPointGroupReference
          index in that table indicates that an Observation Point is
          unknown or unspecified for a Metering Process cache."
      ::= { ipfixObservationPointEntry 1 }

  ipfixObservationPointIndex OBJECT-TYPE
      SYNTAX      Unsigned32 (1..4294967295)
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "Locally arbitrary, but unique identifier of an entry in the
          ipfixObservationPointTable.  The value is expected to remain
          constant from a re-initialization of the entity's network
          management agent to the next re-initialization.

          This index represents a single Observation Point in an
          Observation Point group."
      ::= { ipfixObservationPointEntry 2 }

  ipfixObservationPointObservationDomainId OBJECT-TYPE
      SYNTAX      Unsigned32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The ID of the Observation Domain in which this
          Observation Point is included.

          The special value of 0 indicates that the Observation
          Points within this group cannot be applied to a single
          Observation Domain."
      REFERENCE
          "RFC 5101, Specification of the IP Flow Information Export
          (IPFIX) Protocol for the Exchange of IP Traffic Flow
          Information, Section 3.1."
      ::= { ipfixObservationPointEntry 3 }

  ipfixObservationPointPhysicalEntity OBJECT-TYPE
      SYNTAX      PhysicalIndexOrZero
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "This object contains the index of a physical entity in
          the ENTITY MIB.  This physical entity is the given
          Observation Point.  If such a physical entity cannot be



Dietz, et al.                Standards Track                   [Page 41]

RFC 6615                        IPFIX MIB                      June 2012


          specified or is not known, then the object is zero."
      ::= { ipfixObservationPointEntry 4 }

  ipfixObservationPointPhysicalInterface OBJECT-TYPE
      SYNTAX      InterfaceIndexOrZero
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "This object contains the index of a physical interface in
          the Interfaces MIB.  This physical interface is the given
          Observation Point.  If such a physical interface cannot be
          specified or is not known, then the object is zero.

          This object MAY be used alone or in addition to
          ipfixObservationPointPhysicalEntity.  If
          ipfixObservationPointPhysicalEntity is not zero, this
          object MUST point to the same physical interface that is
          referenced in ipfixObservationPointPhysicalEntity.
          Otherwise, it may reference any interface in the
          Interfaces MIB."
      ::= { ipfixObservationPointEntry 5 }

  ipfixObservationPointPhysicalEntityDirection OBJECT-TYPE
      SYNTAX      INTEGER {
                      unknown(0),
                      ingress(1),
                      egress(2),
                      both(3)
                  }
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The direction of the Flow that is monitored on the given
          physical entity.  The following values are valid:

          unknown(0)
              This value MUST be used if a direction is not known for
              the given physical entity.

          ingress(1)
              This value is used for monitoring incoming Flows on the
              given physical entity.

          egress(2)
              This value is used for monitoring outgoing Flows on the
              given physical entity.

          both(3)



Dietz, et al.                Standards Track                   [Page 42]

RFC 6615                        IPFIX MIB                      June 2012


              This value is used for monitoring incoming and outgoing
              Flows on the given physical entity."
      ::= { ipfixObservationPointEntry 6 }

  --------------------------------------------------------------------
  -- 1.1.7: Selection Process Table
  --------------------------------------------------------------------
  ipfixSelectionProcessTable OBJECT-TYPE
      SYNTAX      SEQUENCE OF IpfixSelectionProcessEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "This table contains Selector Functions connected to a
          Metering Process by the index ipfixMeteringProcessCacheId.
          The Selector Functions are grouped into Selection Processes
          by the ipfixSelectionProcessIndex.  The Selector Functions
          are applied within the Selection Process to the packets
          observed for the given Metering Process cache in increasing
          order as indicated by the ipfixSelectionProcessSelectorIndex.
          This means Selector Functions with a lower
          ipfixSelectionProcessSelectorIndex are applied first.
          The remaining packets are accounted for in Flow Records.

          Since IPFIX does not define any Selector Function (except
          selecting every packet), this is a placeholder for future
          use and a guideline for implementing enterprise-specific
          Selector Function objects.

          The following object tree should help the reader visualize
          how the Selector Function objects should be implemented:

          ipfixSelectorFunctions
          |
          +- ipfixFuncSelectAll
          |  |
          |  +- ipfixFuncSelectAllAvail (is the function available?)
          |
          +- ipfixFuncF2
          |  |
          |  +- ipfixFuncF2Avail (is the function F2 available?)
          |  |
          |  +- ipfixFuncF2Parameters (a table with parameters)
          ...
          |
          +- ipfixFuncFn...






Dietz, et al.                Standards Track                   [Page 43]

RFC 6615                        IPFIX MIB                      June 2012


          If a Selector Function takes parameters, the MIB should
          contain a table with an entry for each set of parameters
          used at the Exporter."
      ::= { ipfixMainObjects 7 }

  ipfixSelectionProcessEntry OBJECT-TYPE
      SYNTAX      IpfixSelectionProcessEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "Defines an entry in the ipfixSelectionProcessTable."
      INDEX       {
          ipfixMeteringProcessCacheId,
          ipfixSelectionProcessIndex,
          ipfixSelectionProcessSelectorIndex
      }
      ::= { ipfixSelectionProcessTable 1 }

  IpfixSelectionProcessEntry ::= SEQUENCE {
          ipfixSelectionProcessIndex            Unsigned32,
          ipfixSelectionProcessSelectorIndex    Unsigned32,
          ipfixSelectionProcessSelectorFunction OBJECT IDENTIFIER
      }

  ipfixSelectionProcessIndex OBJECT-TYPE
      SYNTAX      Unsigned32 (1..4294967295)
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "Locally arbitrary, but unique identifier of an entry in the
          ipfixSelectionProcessTable.  The value is expected to remain
          constant from a re-initialization of the entity's network
          management agent to the next re-initialization."
      ::= { ipfixSelectionProcessEntry 1 }

  ipfixSelectionProcessSelectorIndex OBJECT-TYPE
      SYNTAX      Unsigned32 (1..4294967295)
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "Index specifying the order in which the referenced
          ipfixSelectionProcessSelectorFunctions are applied to the
          observed packet stream within the given Selection Process
          (identified by the ipfixSelectionProcessIndex).  The
          Selector Functions are applied in increasing order; i.e.,
          Selector Functions with a lower index are applied first."
      ::= { ipfixSelectionProcessEntry 2 }




Dietz, et al.                Standards Track                   [Page 44]

RFC 6615                        IPFIX MIB                      June 2012


  ipfixSelectionProcessSelectorFunction OBJECT-TYPE
      SYNTAX      OBJECT IDENTIFIER
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The pointer to the Selector Function used at position
          ipfixSelectionProcessSelectorIndex in the list of Selector
          Functions for the Metering Process cache specified by the
          index ipfixMeteringProcessCacheId and for the given
          Selection Process (identified by the
          ipfixSelectionProcessIndex).

          This usually points to an object in the IPFIX SELECTOR MIB.
          If the Selector Function does not take parameters, then it
          MUST point to the root of the function subtree.  If the
          function takes parameters, then it MUST point to an entry
          in the parameter table of the Selector Function."
      ::= { ipfixSelectionProcessEntry 3 }

  --------------------------------------------------------------------
  -- 1.2.1: Transport Session Statistics Table
  --------------------------------------------------------------------
  ipfixTransportSessionStatsTable  OBJECT-TYPE
      SYNTAX      SEQUENCE OF IpfixTransportSessionStatsEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "This table lists Transport Session statistics between
          Exporting Processes and Collecting Processes."
      ::= { ipfixStatistics 1 }

  ipfixTransportSessionStatsEntry OBJECT-TYPE
      SYNTAX      IpfixTransportSessionStatsEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "Defines an entry in the ipfixTransportSessionStatsTable."
      AUGMENTS    { ipfixTransportSessionEntry }
      ::= { ipfixTransportSessionStatsTable 1 }

  IpfixTransportSessionStatsEntry ::=
      SEQUENCE {
          ipfixTransportSessionRate              Gauge32,
          ipfixTransportSessionPackets           Counter64,
          ipfixTransportSessionBytes             Counter64,
          ipfixTransportSessionMessages          Counter64,
          ipfixTransportSessionDiscardedMessages Counter64,
          ipfixTransportSessionRecords           Counter64,



Dietz, et al.                Standards Track                   [Page 45]

RFC 6615                        IPFIX MIB                      June 2012


          ipfixTransportSessionTemplates         Counter64,
          ipfixTransportSessionOptionsTemplates  Counter64,
          ipfixTransportSessionDiscontinuityTime TimeStamp
      }

  ipfixTransportSessionRate OBJECT-TYPE
      SYNTAX      Gauge32
      UNITS       "bytes/second"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The number of bytes per second received by the
          Collector or transmitted by the Exporter.  A
          value of zero (0) means that no packets were sent or
          received yet.  This object is updated every second."
      ::= { ipfixTransportSessionStatsEntry 1 }

  ipfixTransportSessionPackets OBJECT-TYPE
      SYNTAX      Counter64
      UNITS       "packets"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The number of packets received by the Collector
          or transmitted by the Exporter.
          Discontinuities in the value of this counter can occur at
          re-initialization of the management system and at other
          times as indicated by the value of
          ipfixTransportSessionDiscontinuityTime."
      ::= { ipfixTransportSessionStatsEntry 2 }

  ipfixTransportSessionBytes OBJECT-TYPE
      SYNTAX      Counter64
      UNITS       "bytes"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The number of bytes received by the Collector
          or transmitted by the Exporter.
          Discontinuities in the value of this counter can occur at
          re-initialization of the management system and at other
          times as indicated by the value of
          ipfixTransportSessionDiscontinuityTime."
      ::= { ipfixTransportSessionStatsEntry 3 }

  ipfixTransportSessionMessages OBJECT-TYPE
      SYNTAX      Counter64
      MAX-ACCESS  read-only



Dietz, et al.                Standards Track                   [Page 46]

RFC 6615                        IPFIX MIB                      June 2012


      STATUS      current
      DESCRIPTION
          "The number of IPFIX Messages received by the
          Collector or transmitted by the Exporter.
          Discontinuities in the value of this counter can occur at
          re-initialization of the management system and at other
          times as indicated by the value of
          ipfixTransportSessionDiscontinuityTime."
      ::= { ipfixTransportSessionStatsEntry 4 }

  ipfixTransportSessionDiscardedMessages OBJECT-TYPE
      SYNTAX      Counter64
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The number of received IPFIX Messages that are malformed,
          cannot be decoded, are received in the wrong order, or are
          missing according to the sequence number.

          If used at the Exporter, the number of messages that could
          not be sent due to, for example, internal buffer overflows,
          network congestion, or routing issues.
          Discontinuities in the value of this counter can occur at
          re-initialization of the management system and at other
          times as indicated by the value of
          ipfixTransportSessionDiscontinuityTime."
      ::= { ipfixTransportSessionStatsEntry 5 }

  ipfixTransportSessionRecords OBJECT-TYPE
      SYNTAX      Counter64
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The number of Data Records received by the Collector or
          transmitted by the Exporter.
          Discontinuities in the value of this counter can occur at
          re-initialization of the management system and at other
          times as indicated by the value of
          ipfixTransportSessionDiscontinuityTime."
      ::= { ipfixTransportSessionStatsEntry 6 }

  ipfixTransportSessionTemplates OBJECT-TYPE
      SYNTAX      Counter64
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The number of Templates received or transmitted.
          Discontinuities in the value of this counter can occur at



Dietz, et al.                Standards Track                   [Page 47]

RFC 6615                        IPFIX MIB                      June 2012


          re-initialization of the management system and at other
          times as indicated by the value of
          ipfixTransportSessionDiscontinuityTime."
      ::= { ipfixTransportSessionStatsEntry 7 }

  ipfixTransportSessionOptionsTemplates OBJECT-TYPE
      SYNTAX      Counter64
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The number of Options Templates received or transmitted.
          Discontinuities in the value of this counter can occur at
          re-initialization of the management system and at other
          times as indicated by the value of
          ipfixTransportSessionDiscontinuityTime."
      ::= { ipfixTransportSessionStatsEntry 8 }

  ipfixTransportSessionDiscontinuityTime OBJECT-TYPE
      SYNTAX      TimeStamp
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The value of sysUpTime at the most recent occasion at which
          one or more of the Transport Session counters suffered a
          discontinuity.
          A value of zero indicates that no such discontinuity has
          occurred since the last re-initialization of the local
          management subsystem."
      ::= { ipfixTransportSessionStatsEntry 9 }

  --------------------------------------------------------------------
  -- 1.2.2: Template Statistics Table
  --------------------------------------------------------------------
  ipfixTemplateStatsTable  OBJECT-TYPE
      SYNTAX      SEQUENCE OF IpfixTemplateStatsEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "This table lists statistics objects per Template."
      ::= { ipfixStatistics 2 }

  ipfixTemplateStatsEntry OBJECT-TYPE
      SYNTAX      IpfixTemplateStatsEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "Defines an entry in the ipfixTemplateStatsTable."




Dietz, et al.                Standards Track                   [Page 48]

RFC 6615                        IPFIX MIB                      June 2012


      AUGMENTS    { ipfixTemplateEntry }
      ::= { ipfixTemplateStatsTable 1 }

  IpfixTemplateStatsEntry ::=
      SEQUENCE {
          ipfixTemplateDataRecords       Counter64,
          ipfixTemplateDiscontinuityTime TimeStamp
      }

  ipfixTemplateDataRecords OBJECT-TYPE
      SYNTAX      Counter64
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The number of Data Records that are transmitted or received
          per Template.
          Discontinuities in the value of this counter can occur at
          re-initialization of the management system and at other
          times as indicated by the value of
          ipfixTemplateDiscontinuityTime."
      ::= { ipfixTemplateStatsEntry 1 }

  ipfixTemplateDiscontinuityTime OBJECT-TYPE
      SYNTAX      TimeStamp
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The value of sysUpTime at the most recent occasion at which
          the Template counter suffered a discontinuity.
          A value of zero indicates that no such discontinuity has
          occurred since the last re-initialization of the local
          management subsystem."
      ::= { ipfixTemplateStatsEntry 2 }

  --------------------------------------------------------------------
  -- 1.2.3: Metering Process Statistics Table
  --------------------------------------------------------------------
  ipfixMeteringProcessStatsTable  OBJECT-TYPE
      SYNTAX      SEQUENCE OF IpfixMeteringProcessStatsEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "This table lists statistics objects that have data per
          Metering Process cache.

          On Collectors, this table is not needed."
      ::= { ipfixStatistics 3 }




Dietz, et al.                Standards Track                   [Page 49]

RFC 6615                        IPFIX MIB                      June 2012


  ipfixMeteringProcessStatsEntry OBJECT-TYPE
      SYNTAX      IpfixMeteringProcessStatsEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "Defines an entry in the ipfixMeteringProcessStatsTable."
      AUGMENTS    { ipfixMeteringProcessEntry }
      ::= { ipfixMeteringProcessStatsTable 1 }

  IpfixMeteringProcessStatsEntry ::=
      SEQUENCE {
          ipfixMeteringProcessCacheActiveFlows          Gauge32,
          ipfixMeteringProcessCacheUnusedCacheEntries   Gauge32,
          ipfixMeteringProcessCacheDataRecords          Counter64,
          ipfixMeteringProcessCacheDiscontinuityTime    TimeStamp
      }

  ipfixMeteringProcessCacheActiveFlows OBJECT-TYPE
      SYNTAX      Gauge32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The number of Flows currently active at this cache."
      ::= { ipfixMeteringProcessStatsEntry 1 }

  ipfixMeteringProcessCacheUnusedCacheEntries   OBJECT-TYPE
      SYNTAX      Gauge32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The number of unused cache entries."
      ::= { ipfixMeteringProcessStatsEntry 2 }

  ipfixMeteringProcessCacheDataRecords OBJECT-TYPE
      SYNTAX      Counter64
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The number of Data Records generated.
          Discontinuities in the value of this counter can occur at
          re-initialization of the management system and at other
          times as indicated by the value of
          ipfixMeteringProcessCacheDiscontinuityTime."
      ::= { ipfixMeteringProcessStatsEntry 3 }

  ipfixMeteringProcessCacheDiscontinuityTime OBJECT-TYPE
      SYNTAX      TimeStamp
      MAX-ACCESS  read-only



Dietz, et al.                Standards Track                   [Page 50]

RFC 6615                        IPFIX MIB                      June 2012


      STATUS      current
      DESCRIPTION
          "The value of sysUpTime at the most recent occasion at which
          the Metering Process counter suffered a discontinuity.
          A value of zero indicates that no such discontinuity has
          occurred since the last re-initialization of the local
          management subsystem."
      ::= { ipfixMeteringProcessStatsEntry 4 }

  --------------------------------------------------------------------
  -- 1.2.4: Selection Process Statistics Table
  --------------------------------------------------------------------
  ipfixSelectionProcessStatsTable OBJECT-TYPE
      SYNTAX      SEQUENCE OF IpfixSelectionProcessStatsEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "This table contains statistics for the Selector Functions
          connected to a Metering Process by the index
          ipfixMeteringProcessCacheId.

          The indexes MUST match an entry in the
          ipfixSelectionProcessTable."
      ::= { ipfixStatistics 4 }

  ipfixSelectionProcessStatsEntry OBJECT-TYPE
      SYNTAX      IpfixSelectionProcessStatsEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "Defines an entry in the ipfixSelectionProcessStatsTable."
      AUGMENTS    { ipfixSelectionProcessEntry }
      ::= { ipfixSelectionProcessStatsTable 1 }

  IpfixSelectionProcessStatsEntry ::= SEQUENCE {
          ipfixSelectionProcessStatsPacketsObserved   Counter64,
          ipfixSelectionProcessStatsPacketsDropped    Counter64,
          ipfixSelectionProcessStatsDiscontinuityTime TimeStamp
      }

  ipfixSelectionProcessStatsPacketsObserved OBJECT-TYPE
      SYNTAX      Counter64
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The number of packets observed at the entry point of the
          function.  The entry point may be the Observation Point or
          the exit point of another Selector Function.



Dietz, et al.                Standards Track                   [Page 51]

RFC 6615                        IPFIX MIB                      June 2012


          Discontinuities in the value of this counter can occur at
          re-initialization of the management system and at other
          times as indicated by the value of
          ipfixSelectionProcessStatsDiscontinuityTime."
      ::= { ipfixSelectionProcessStatsEntry 1 }

  ipfixSelectionProcessStatsPacketsDropped OBJECT-TYPE
      SYNTAX      Counter64
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The number of packets dropped while selecting packets.
          Discontinuities in the value of this counter can occur at
          re-initialization of the management system and at other
          times as indicated by the value of
          ipfixSelectionProcessStatsDiscontinuityTime."
      ::= { ipfixSelectionProcessStatsEntry 2 }

  ipfixSelectionProcessStatsDiscontinuityTime OBJECT-TYPE
      SYNTAX      TimeStamp
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The value of sysUpTime at the most recent occasion at which
          one or more of the Selector counters suffered a
          discontinuity.
          A value of zero indicates that no such discontinuity has
          occurred since the last re-initialization of the local
          management subsystem."
      ::= { ipfixSelectionProcessStatsEntry 3 }

  --==================================================================
  -- 2: Conformance Information
  --==================================================================
  ipfixCompliances OBJECT IDENTIFIER ::= { ipfixConformance 1 }
  ipfixGroups      OBJECT IDENTIFIER ::= { ipfixConformance 2 }

  --------------------------------------------------------------------
  -- 2.1: Compliance Statements
  --------------------------------------------------------------------
  ipfixCollectorCompliance MODULE-COMPLIANCE
      STATUS      current
      DESCRIPTION
          "An implementation that builds an IPFIX Collector
          that complies with this module MUST implement the objects
          defined in the mandatory group ipfixCommonGroup.





Dietz, et al.                Standards Track                   [Page 52]

RFC 6615                        IPFIX MIB                      June 2012


          The implementation of all objects in the other groups is
          optional and depends on the corresponding functionality
          implemented in the equipment.

          An implementation that is compliant with this MIB module
          is limited to using only the values TCP (6), UDP (17), and
          SCTP (132) in the ipfixTransportSessionProtocol object
          because these are the only protocols currently specified
          for usage within IPFIX (see RFC 5101)."
      MODULE  -- this module
      MANDATORY-GROUPS {
          ipfixCommonGroup
      }

      GROUP ipfixCommonStatsGroup
      DESCRIPTION
          "These objects should be implemented if the statistics
          function is implemented in the equipment."
      ::= { ipfixCompliances 1 }

  ipfixExporterCompliance MODULE-COMPLIANCE
      STATUS      current
      DESCRIPTION
          "An implementation that builds an IPFIX Exporter that
          complies with this module MUST implement the objects defined
          in the mandatory group ipfixCommonGroup.  The implementation
          of all other objects depends on the implementation of the
          corresponding functionality in the equipment."
      MODULE  -- this module
      MANDATORY-GROUPS {
              ipfixCommonGroup,
              ipfixExporterGroup
      }

      GROUP ipfixCommonStatsGroup
      DESCRIPTION
          "These objects should be implemented if the statistics
          function is implemented in the equipment."

      GROUP ipfixExporterStatsGroup
      DESCRIPTION
          "These objects MUST be implemented if statistics functions
          are implemented in the equipment."
      ::= { ipfixCompliances 2 }







Dietz, et al.                Standards Track                   [Page 53]

RFC 6615                        IPFIX MIB                      June 2012


  --------------------------------------------------------------------
  -- 2.2: MIB Grouping
  --------------------------------------------------------------------
  ipfixCommonGroup OBJECT-GROUP
      OBJECTS {
          ipfixTransportSessionProtocol,
          ipfixTransportSessionSourceAddressType,
          ipfixTransportSessionSourceAddress,
          ipfixTransportSessionDestinationAddressType,
          ipfixTransportSessionDestinationAddress,
          ipfixTransportSessionSourcePort,
          ipfixTransportSessionDestinationPort,
          ipfixTransportSessionSctpAssocId,
          ipfixTransportSessionDeviceMode,
          ipfixTransportSessionTemplateRefreshTimeout,
          ipfixTransportSessionOptionsTemplateRefreshTimeout,
          ipfixTransportSessionTemplateRefreshPacket,
          ipfixTransportSessionOptionsTemplateRefreshPacket,
          ipfixTransportSessionIpfixVersion,
          ipfixTransportSessionStatus,

          ipfixTemplateSetId,
          ipfixTemplateAccessTime,

          ipfixTemplateDefinitionIeId,
          ipfixTemplateDefinitionIeLength,
          ipfixTemplateDefinitionEnterpriseNumber,
          ipfixTemplateDefinitionFlags
      }
      STATUS      current
      DESCRIPTION
          "The main IPFIX objects."
      ::= { ipfixGroups 1 }

  ipfixCommonStatsGroup OBJECT-GROUP
      OBJECTS {
          ipfixTransportSessionRate,
          ipfixTransportSessionPackets,
          ipfixTransportSessionBytes,
          ipfixTransportSessionMessages,
          ipfixTransportSessionDiscardedMessages,
          ipfixTransportSessionRecords,
          ipfixTransportSessionTemplates,
          ipfixTransportSessionOptionsTemplates,
          ipfixTransportSessionDiscontinuityTime,

          ipfixTemplateDataRecords,
          ipfixTemplateDiscontinuityTime



Dietz, et al.                Standards Track                   [Page 54]

RFC 6615                        IPFIX MIB                      June 2012


      }
      STATUS      current
      DESCRIPTION
          "Common statistical objects."
      ::= { ipfixGroups 2 }

  ipfixExporterGroup OBJECT-GROUP
      OBJECTS {
          ipfixExportMemberType,

          ipfixMeteringProcessObservationPointGroupRef,
          ipfixMeteringProcessCacheActiveTimeout,
          ipfixMeteringProcessCacheIdleTimeout,

          ipfixObservationPointObservationDomainId,
          ipfixObservationPointPhysicalEntity,
          ipfixObservationPointPhysicalInterface,
          ipfixObservationPointPhysicalEntityDirection,

          ipfixSelectionProcessSelectorFunction
      }
      STATUS      current
      DESCRIPTION
          "The main objects for Exporters."
      ::= { ipfixGroups 3 }

  ipfixExporterStatsGroup OBJECT-GROUP
      OBJECTS {
          ipfixMeteringProcessCacheActiveFlows,
          ipfixMeteringProcessCacheUnusedCacheEntries,
          ipfixMeteringProcessCacheDataRecords,
          ipfixMeteringProcessCacheDiscontinuityTime,

          ipfixSelectionProcessStatsPacketsObserved,
          ipfixSelectionProcessStatsPacketsDropped,
          ipfixSelectionProcessStatsDiscontinuityTime
      }
      STATUS      current
      DESCRIPTION
          "The statistical objects for Exporters."
      ::= { ipfixGroups 4 }

  END








Dietz, et al.                Standards Track                   [Page 55]

RFC 6615                        IPFIX MIB                      June 2012


8.2.  IPFIX SELECTOR MIB Definition

  IPFIX-SELECTOR-MIB DEFINITIONS ::= BEGIN

  IMPORTS
      MODULE-IDENTITY, OBJECT-TYPE, mib-2
          FROM SNMPv2-SMI                              -- [RFC2578]
      TruthValue
          FROM SNMPv2-TC                               -- [RFC2579]
      MODULE-COMPLIANCE, OBJECT-GROUP
          FROM SNMPv2-CONF;                            -- [RFC2580]

  ipfixSelectorMIB MODULE-IDENTITY
      LAST-UPDATED "201206110000Z"         -- 11 June 2012
      ORGANIZATION "IETF IPFIX Working Group"
      CONTACT-INFO
          "WG charter:
            http://www.ietf.org/html.charters/ipfix-charter.html

          Mailing Lists:
            General Discussion: [email protected]
            To Subscribe: http://www1.ietf.org/mailman/listinfo/ipfix
            Archive:
        http://www1.ietf.org/mail-archive/web/ipfix/current/index.html

          Editor:
            Thomas Dietz
            NEC Europe Ltd.
            NEC Laboratories Europe
            Network Research Division
            Kurfuersten-Anlage 36
            Heidelberg  69115
            Germany
            Phone: +49 6221 4342-128
            Email: [email protected]

            Atsushi Kobayashi
            NTT Information Sharing Platform Laboratories
            3-9-11 Midori-cho
            Musashino-shi, Tokyo  180-8585
            Japan
            Phone: +81-422-59-3978
            Email: [email protected]

            Benoit Claise
            Cisco Systems, Inc.
            De Kleetlaan 6a b1
            Diegem  1831



Dietz, et al.                Standards Track                   [Page 56]

RFC 6615                        IPFIX MIB                      June 2012


            Belgium
            Phone:  +32 2 704 5622
            Email: [email protected]

            Gerhard Muenz
            Technische Universitaet Muenchen
            Department of Informatics
            Chair for Network Architectures and Services (I8)
            Boltzmannstr. 3
            Garching  85748
            Germany
            Email: [email protected]"

      DESCRIPTION
          "The IPFIX SELECTOR MIB module defined in this section
          provides the standard Filtering and Sampling functions that
          can be referenced in the ipfixSelectionProcessTable.  All
          standard Filtering and Sampling functions MUST be registered
          in the subtree under object ipfixSelectorFunctions
          (1.3.6.1.2.1.194.1.1).  The top-level OIDs in the subtree
          under object ipfixSelectorFunctions MUST be registered in a
          sub-registry maintained by IANA at
          <http://www.iana.org/assignments/smi-numbers/>.

          New Selector Functions MUST be registered at IANA and are
          subject to Expert Review [RFC5226], i.e., review by one of a
          group of experts designated by an IETF Area Director.  The
          group of experts MUST check the requested MIB objects for
          completeness and accuracy of the description.  Requests for
          MIB objects that duplicate the functionality of existing
          objects SHOULD be declined.  The smallest available OID
          SHOULD be assigned to new MIB objects.  The specification
          of new MIB objects SHOULD follow the structure specified in
          [RFC6615] and MUST be published using a well-
          established and persistent publication medium.  The experts
          will initially be drawn from the Working Group Chairs and
          document editors of the IPFIX and PSAMP Working Groups.

          Copyright (c) 2012 IETF Trust and the persons identified as
          authors of the code.  All rights reserved.

          Redistribution and use in source and binary forms, with or
          without modification, is permitted pursuant to, and subject
          to the license terms contained in, the Simplified BSD
          License set forth in Section 4.c of the IETF Trust's
          Legal Provisions Relating to IETF Documents
          (http://trustee.ietf.org/license-info)."




Dietz, et al.                Standards Track                   [Page 57]

RFC 6615                        IPFIX MIB                      June 2012


  --  Revision history

      REVISION     "201206110000Z"         -- 11 June 2012
      DESCRIPTION
          "Update to MIB description to reflect updated registration
          of new Sampling and Filtering functions.  Published as
          RFC 6615."

      REVISION     "201003150000Z"         -- 15 March 2010
      DESCRIPTION
          "Initial version, published as RFC 5815."

      ::= { mib-2 194 }

  --******************************************************************
  -- Top-Level Structure of the MIB
  --******************************************************************

  ipfixSelectorObjects     OBJECT IDENTIFIER
      ::= { ipfixSelectorMIB 1 }
  ipfixSelectorConformance OBJECT IDENTIFIER
      ::= { ipfixSelectorMIB 2 }

  --==================================================================
  -- 1: Objects Used by All IPFIX Implementations
  --==================================================================
  --------------------------------------------------------------------
  -- 1.1: Packet Selector Functions for IPFIX
  --------------------------------------------------------------------
  ipfixSelectorFunctions OBJECT IDENTIFIER
      ::= { ipfixSelectorObjects 1 }

  --------------------------------------------------------------------
  -- 1.1.1: Function 1: Selecting All Packets
  --------------------------------------------------------------------
  ipfixFuncSelectAll OBJECT IDENTIFIER
      ::= { ipfixSelectorFunctions 1 }

  ipfixFuncSelectAllAvail OBJECT-TYPE
      SYNTAX      TruthValue
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "This object indicates the availability of the trivial
          function of selecting all packets.  This function is always
          available."
      ::= { ipfixFuncSelectAll 1 }




Dietz, et al.                Standards Track                   [Page 58]

RFC 6615                        IPFIX MIB                      June 2012


  --==================================================================
  -- 2: Conformance Information
  --==================================================================
  ipfixSelectorCompliances OBJECT IDENTIFIER
      ::= { ipfixSelectorConformance 1 }
  ipfixSelectorGroups      OBJECT IDENTIFIER
      ::= { ipfixSelectorConformance 2 }

  --------------------------------------------------------------------
  -- 2.1: Compliance Statements
  --------------------------------------------------------------------
  ipfixSelectorBasicCompliance MODULE-COMPLIANCE
      STATUS      current
      DESCRIPTION
          "An implementation that builds an IPFIX Exporter that
          complies with this module MUST implement the objects defined
          in the mandatory group ipfixBasicGroup.  The implementation
          of all other objects depends on the implementation of the
          corresponding functionality in the equipment."
      MODULE  -- this module
      MANDATORY-GROUPS {
              ipfixSelectorBasicGroup
      }
      ::= { ipfixSelectorCompliances 1 }

  --------------------------------------------------------------------
  -- 2.2: MIB Grouping
  --------------------------------------------------------------------
  ipfixSelectorBasicGroup OBJECT-GROUP
      OBJECTS {
          ipfixFuncSelectAllAvail
      }
      STATUS      current
      DESCRIPTION
          "The main IPFIX objects."
      ::= { ipfixSelectorGroups 1 }

  END













Dietz, et al.                Standards Track                   [Page 59]

RFC 6615                        IPFIX MIB                      June 2012


9.  Security Considerations

  There are no management objects defined in this MIB module that have
  a MAX-ACCESS clause of read-write and/or read-create.  So, if this
  MIB module is implemented correctly, then there is no risk that an
  intruder can alter or create any management objects of this MIB
  module via direct SNMP SET operations.

  Some of the readable objects in this MIB module (i.e., objects with a
  MAX-ACCESS other than not-accessible) may be considered sensitive or
  vulnerable in some network environments.  It is thus important to
  control even GET and/or NOTIFY access to these objects and possibly
  to even encrypt the values of these objects when sending them over
  the network via SNMP.  These are the tables and objects and their
  sensitivity/vulnerability:

  o  ipfixTransportSessionTable - contains configuration data that
     might be sensitive because objects in this table may reveal
     information about the network infrastructure

  o  ipfixExportTable - contains configuration data that might be
     sensitive because objects in this table may reveal information
     about the network infrastructure as well

  o  ipfixMeteringProcessTable - contains configuration data that might
     be sensitive because objects in this table may reveal information
     about the IPFIX Device itself

  o  ipfixObservationPointTable - contains configuration data that
     might be sensitive because objects in this table may reveal
     information about the IPFIX Device itself and the network
     infrastructure

  o  ipfixSelectorFunctions - currently contains no sensitive data but
     might want to be secured anyway, since it may contain sensitive
     data in a future version

  All other objects and tables contain no data that is considered
  sensitive.

  SNMP versions prior to SNMPv3 did not include adequate security.
  Even if the network itself is secure (for example by using IPsec),
  there is no control as to who on the secure network is allowed to
  access and GET/SET (read/change/create/delete) the objects in this
  MIB module.






Dietz, et al.                Standards Track                   [Page 60]

RFC 6615                        IPFIX MIB                      June 2012


  Implementations MUST provide the security features described by the
  SNMPv3 framework (see [RFC3410]), including full support for
  authentication and privacy via the User-based Security Model (USM)
  [RFC3414] with the AES cipher algorithm [RFC3826].  Implementations
  MAY also provide support for the Transport Security Model (TSM)
  [RFC5591] in combination with a secure transport such as SSH
  [RFC5592] or TLS/DTLS [RFC6353].

  Further, deployment of SNMP versions prior to SNMPv3 is NOT
  RECOMMENDED.  Instead, it is RECOMMENDED to deploy SNMPv3 and to
  enable cryptographic security.  It is then a customer/operator
  responsibility to ensure that the SNMP entity giving access to an
  instance of this MIB module is properly configured to give access to
  the objects only to those principals (users) that have legitimate
  rights to indeed GET or SET (change/create/delete) them.

10.  IANA Considerations

  The MIB module in this document uses the following IANA-assigned
  OBJECT IDENTIFIER values recorded in the SMI Numbers registry:

          Descriptor        OBJECT IDENTIFIER value
          ----------        -----------------------
          ipfixMIB          { mib-2 193 }
          ipfixSelectorMIB  { mib-2 194 }

  The IPFIX SELECTOR MIB registry as defined in [RFC5815] Section 10
  has been removed by IANA, as its use is discontinued with this
  document.

  IANA has created and maintains a sub-registry at
  http://www.iana.org/assignments/smi-numbers, in which the top-level
  OIDs in the subtree under object ipfixSelectorFunctions MUST be
  registered.  The initial version of this sub-registry should contain
  the following:

  Sub-registry Name: IPFIX-SELECTOR-MIB Functions
  Reference: [RFC6615]
  Registration Procedures: Expert Review [RFC5226]

  Prefix: iso.org.dod.internet.mgmt.
  mib-2.ipfixSelectorMIB.ipfixSelectorObjects.ipfixSelectorFunctions
  (1.3.6.1.2.1.194.1.1)

  Decimal   Name                 Description            Reference
  -------   ------------------   -----------------      ---------
       1    ipfixFuncSelectAll   Select everything      [RFC6615]




Dietz, et al.                Standards Track                   [Page 61]

RFC 6615                        IPFIX MIB                      June 2012


  Additions to this sub-registry are subject to Expert Review
  [RFC5226], i.e., review by one of a group of experts designated by an
  IETF Area Director.  The group of experts MUST check the requested
  MIB objects for completeness and accuracy of the description.
  Requests for MIB objects that duplicate the functionality of existing
  objects SHOULD be declined.  The smallest available OID SHOULD be
  assigned to new MIB objects.  The specification of new MIB objects
  SHOULD follow the structure specified in Section 6.1 and MUST be
  published using a well-established and persistent publication medium.
  The experts will initially be drawn from the Working Group Chairs and
  document editors of the IPFIX and PSAMP Working Groups.

11.  Acknowledgments

  This document is a product of the IPFIX Working Group.  The authors
  would like to thank the following persons: Paul Aitken for his
  detailed review, Dan Romascanu and the MIB doctors, and many more,
  for their technical reviews and feedback.

12.  References

12.1.  Normative References

  [RFC2119]  Bradner, S., "Key words for use in RFCs to Indicate
             Requirement Levels", BCP 14, RFC 2119, March 1997.

  [RFC2578]  McCloghrie, K., Ed., Perkins, D., Ed., and J.
             Schoenwaelder, Ed., "Structure of Management Information
             Version 2 (SMIv2)", STD 58, RFC 2578, April 1999.

  [RFC2579]  McCloghrie, K., Ed., Perkins, D., Ed., and J.
             Schoenwaelder, Ed., "Textual Conventions for SMIv2",
             STD 58, RFC 2579, April 1999.

  [RFC2580]  McCloghrie, K., Ed., Perkins, D., Ed., and J.
             Schoenwaelder, Ed., "Conformance Statements for SMIv2",
             STD 58, RFC 2580, April 1999.

  [RFC2863]  McCloghrie, K. and F. Kastenholz, "The Interfaces Group
             MIB", RFC 2863, June 2000.

  [RFC3873]  Pastor, J. and M. Belinchon, "Stream Control Transmission
             Protocol (SCTP) Management Information Base (MIB)",
             RFC 3873, September 2004.

  [RFC4001]  Daniele, M., Haberman, B., Routhier, S., and J.
             Schoenwaelder, "Textual Conventions for Internet Network
             Addresses", RFC 4001, February 2005.



Dietz, et al.                Standards Track                   [Page 62]

RFC 6615                        IPFIX MIB                      June 2012


  [RFC4133]  Bierman, A. and K. McCloghrie, "Entity MIB (Version 3)",
             RFC 4133, August 2005.

  [RFC5101]  Claise, B., Ed., "Specification of the IP Flow Information
             Export (IPFIX) Protocol for the Exchange of IP Traffic
             Flow Information", RFC 5101, January 2008.

  [RFC5102]  Quittek, J., Bryant, S., Claise, B., Aitken, P., and J.
             Meyer, "Information Model for IP Flow Information Export",
             RFC 5102, January 2008.

  [RFC5226]  Narten, T. and H. Alvestrand, "Guidelines for Writing an
             IANA Considerations Section in RFCs", BCP 26, RFC 5226,
             May 2008.

  [RFC5815]  Dietz, T., Ed., Kobayashi, A., Claise, B., and G. Muenz,
             "Definitions of Managed Objects for IP Flow Information
             Export", RFC 5815, April 2010.

12.2.  Informative References

  [RFC3410]  Case, J., Mundy, R., Partain, D., and B. Stewart,
             "Introduction and Applicability Statements for Internet-
             Standard Management Framework", RFC 3410, December 2002.

  [RFC3414]  Blumenthal, U. and B. Wijnen, "User-based Security Model
             (USM) for version 3 of the Simple Network Management
             Protocol (SNMPv3)", STD 62, RFC 3414, December 2002.

  [RFC3826]  Blumenthal, U., Maino, F., and K. McCloghrie, "The
             Advanced Encryption Standard (AES) Cipher Algorithm in the
             SNMP User-based Security Model", RFC 3826, June 2004.

  [RFC3917]  Quittek, J., Zseby, T., Claise, B., and S. Zander,
             "Requirements for IP Flow Information Export (IPFIX)",
             RFC 3917, October 2004.

  [RFC5470]  Sadasivan, G., Brownlee, N., Claise, B., and J. Quittek,
             "Architecture for IP Flow Information Export", RFC 5470,
             March 2009.

  [RFC5472]  Zseby, T., Boschi, E., Brownlee, N., and B. Claise, "IP
             Flow Information Export (IPFIX) Applicability", RFC 5472,
             March 2009.

  [RFC5474]  Duffield, N., Ed., Chiou, D., Claise, B., Greenberg, A.,
             Grossglauser, M., and J. Rexford, "A Framework for Packet
             Selection and Reporting", RFC 5474, March 2009.



Dietz, et al.                Standards Track                   [Page 63]

RFC 6615                        IPFIX MIB                      June 2012


  [RFC5475]  Zseby, T., Molina, M., Duffield, N., Niccolini, S., and F.
             Raspall, "Sampling and Filtering Techniques for IP Packet
             Selection", RFC 5475, March 2009.

  [RFC5476]  Claise, B., Ed., Johnson, A., and J. Quittek, "Packet
             Sampling (PSAMP) Protocol Specifications", RFC 5476,
             March 2009.

  [RFC5591]  Harrington, D. and W. Hardaker, "Transport Security Model
             for the Simple Network Management Protocol (SNMP)",
             RFC 5591, June 2009.

  [RFC5592]  Harrington, D., Salowey, J., and W. Hardaker, "Secure
             Shell Transport Model for the Simple Network Management
             Protocol (SNMP)", RFC 5592, June 2009.

  [RFC6353]  Hardaker, W., "Transport Layer Security (TLS) Transport
             Model for the Simple Network Management Protocol (SNMP)",
             RFC 6353, July 2011.
































Dietz, et al.                Standards Track                   [Page 64]

RFC 6615                        IPFIX MIB                      June 2012


Authors' Addresses

  Thomas Dietz (editor)
  NEC Europe Ltd.
  NEC Laboratories Europe
  Network Research Division
  Kurfuersten-Anlage 36
  Heidelberg  69115
  DE

  Phone: +49 6221 4342-128
  EMail: [email protected]


  Atsushi Kobayashi
  NTT Information Sharing Platform Laboratories
  3-9-11 Midori-cho
  Musashino-shi, Tokyo  180-8585
  JA

  Phone: +81-422-59-3978
  EMail: [email protected]


  Benoit Claise
  Cisco Systems, Inc.
  De Kleetlaan 6a b1
  Diegem  1831