Network Working Group                                        K. de Graaf
Request for Comments: 2239                              3Com Corporation
Category: Standards Track                                   D. Romascanu
                                                    Madge Networks Ltd.
                                                            D. McMaster
                                                     Cisco Systems Inc.
                                                          K. McCloghrie
                                                     Cisco Systems Inc.
                                                             S. Roberts
                                               Farallon Computing, Inc.
                                                          November 1997


            Definitions of Managed Objects for IEEE 802.3
              Medium Attachment Units (MAUs) using SMIv2


Status of this Memo

  This document specifies an Internet standards track protocol for the
  Internet community, and requests discussion and suggestions for
  improvements.  Please refer to the current edition of the "Internet
  Official Protocol Standards" (STD 1) for the standardization state
  and status of this protocol.  Distribution of this memo is unlimited.

Copyright Notice

  Copyright (C) The Internet Society (1997).  All Rights Reserved.

Table of Contents

  1 The SNMPv2 Network Management Framework ...............    2
  1.1 Object Definitions ..................................    2
  2 Overview ..............................................    3
  2.1 Relationship to RFC 1515 ............................    3
  2.2 MAU Management ......................................    3
  2.3 Relationship to Other MIBs ..........................    3
  2.3.1 Relationship to the MIB-II 'interfaces' group .....    3
  2.3.2 Relationship to the 802.3 Repeater MIB ............    4
  2.4 Management of Internal MAUs .........................    4
  3 Definitions ...........................................    4
  4 Acknowledgements ......................................   39
  5 References ............................................   40
  6 Security Considerations ...............................   41
  7 Authors' Addresses ....................................   41
  8 Full Copyright Statement ..............................   43





de Graaf, et. al.           Standards Track                     [Page 1]

RFC 2239          Managed Objects for IEEE 802.3 MAUs      November 1997


Abstract

  This memo defines an portion of the Management Information Base (MIB)
  for use with network management protocols in the Internet community.
  In particular, it defines objects for managing 10 and 100 Mb/second
  Medium Attachment Units (MAUs) based on IEEE Std 802.3 Section 30,
  "10 & 100 Mb/s Management," October 26, 1995.

1.  The SNMPv2 Network Management Framework

  The SNMPv2 Network Management Framework presently consists of three
  major components.  They are:

  o    the SMI, described in RFC 1902 [6] - the mechanisms used
       for describing and naming objects for the purpose of management.

  o    the MIB-II, STD 17, RFC 1213 [5] - the core set of
       managed objects for the Internet suite of protocols.

  o    the protocol, STD 15, RFC 1157 [10] and/or RFC 1905 [9] -
       the protocol used for accessing managed information.

  Textual conventions are defined in RFC 1903 [7], and conformance
  statements are defined in RFC 1904 [8].

  The Framework permits new objects to be defined for the purpose of
  experimentation and evaluation.

1.1.  Object Definitions

  Managed objects are accessed via a virtual information store, termed
  the Management Information Base or MIB.  Objects in the MIB are
  defined using the subset of Abstract Syntax Notation One (ASN.1)
  defined in the SMI.  In particular, each object type is named by an
  OBJECT IDENTIFIER, an administratively assigned name.  The object
  type together with an object instance serves to uniquely identify a
  specific instantiation of the object.  For human convenience, we
  often use a textual string, termed the descriptor, to refer to the
  object type.












de Graaf, et. al.           Standards Track                     [Page 2]

RFC 2239          Managed Objects for IEEE 802.3 MAUs      November 1997


2.  Overview

2.1.  Relationship to RFC 1515

  This MIB is intended to be a superset of that defined by RFC 1515
  [11], which will go to historic status.  This MIB includes all of the
  objects contained in that MIB, plus several new ones which provide
  additional capabilities.  Implementors are encouraged to support all
  applicable conformance groups in order to make the best use of the
  new functionality provided by this MIB.  The new objects provide
  management support for:

  o    management of 100 Mb/s devices

  o    auto-negotiation on interface MAUs

  o    jack management

2.2.  MAU Management

  Instances of these object types represent attributes of an IEEE 802.3
  MAU.  Several types of MAUs are defined in the IEEE 802.3 CSMA/CD
  standard [1] and [2].  These MAUs may be connected to IEEE 802.3
  repeaters or to 802.3 (Ethernet-like) interfaces.  For convenience
  this document refers to these devices as "repeater MAUs" and
  "interface MAUs."

  The definitions presented here are based on Section 30.5, "Layer
  Management for 10 & 100 Mb/s Medium Attachment Units (MAUs)", and
  Annex 30A, "GDMO Specifications for 802.3 managed objects" of IEEE
  Std 802.3u-1995.  That specification includes definitions for both
  10Mb/s and 100Mb/s devices, and is essentially a superset of the
  10Mb/s definitions given by IEEE 802.3 Section 20.  This
  specification is intended to serve the same purpose: to provide for
  management of both 10Mb/s and 100Mb/s MAUs.

2.3.  Relationship to Other MIBs

  It is assumed that an agent implementing this MIB will also implement
  (at least) the 'system' group defined in MIB-II [5].  The following
  sections identify other MIBs that such an agent should implement.

2.3.1.  Relationship to the MIB-II 'interfaces' group

  The sections of this document that define interface MAU-related
  objects specify an extension to the 'interfaces' group of MIB-II.  An
  agent implementing these interface-MAU related objects must also




de Graaf, et. al.           Standards Track                     [Page 3]

RFC 2239          Managed Objects for IEEE 802.3 MAUs      November 1997


  implement the 'interfaces' group of MIB-II.  The value of the object
  ifMauIfIndex is the same as the value of 'ifIndex' used to
  instantiate the interface to which the given MAU is connected.

  It is expected that an agent implementing the interface-MAU related
  objects in this MIB will also implement the Ethernet- like Interfaces
  MIB, RFC 1650.

  (Note that repeater ports are not represented as interfaces in the
  sense of MIB-II's 'interfaces' group.)

2.3.2.  Relationship to the 802.3 Repeater MIB

  The section of this document that defines repeater MAU-related
  objects specifies an extension to the 802.3 Repeater MIB defined in
  [4].  An agent implementing these repeater-MAU related objects must
  also implement the 802.3 Repeater MIB.

  The values of 'rpMauGroupIndex' and 'rpMauPortIndex' used to
  instantiate a repeater MAU variable shall be the same as the values
  of 'rptrPortGroupIndex' and 'rptrPortIndex' used to instantiate the
  port to which the given MAU is connected.

2.4.  Management of Internal MAUs

  In some situations, a MAU can be "internal" -- i.e., its
  functionality is implemented entirely within a device.  For example,
  a managed repeater may contain an internal repeater- MAU and/or an
  internal interface-MAU through which management communications
  originating on one of the repeater's external ports pass in order to
  reach the management agent associated with the repeater.  Such
  internal MAUs may or may not be managed.  If they are managed,
  objects describing their attributes should appear in the appropriate
  MIB subtree:

  dot3RpMauBasicGroup for internal repeater-MAUs and
  dot3IfMauBasicGroup for internal interface-MAUs.

3.  Definitions

  MAU-MIB DEFINITIONS ::= BEGIN

  IMPORTS
      Counter32, Integer32,
      OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE,
      OBJECT-IDENTITY, mib-2
          FROM SNMPv2-SMI
      TruthValue, TEXTUAL-CONVENTION



de Graaf, et. al.           Standards Track                     [Page 4]

RFC 2239          Managed Objects for IEEE 802.3 MAUs      November 1997


          FROM SNMPv2-TC
      OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP
          FROM SNMPv2-CONF;

  mauMod MODULE-IDENTITY
      LAST-UPDATED "9710310000Z"
      ORGANIZATION "IETF HUB MIB Working Group"
      CONTACT-INFO
          "WG E-mail: [email protected]

               Chair: Dan Romascanu
              Postal: Madge Networks (Israel) Ltd.
                      Atidim Technology Park, Bldg. 3
                      Tel Aviv 61131, Israel
                 Tel: 972-3-6458414, 6458458
                 Fax: 972-3-6487146
              E-mail: [email protected]

              Editor: Kathryn de Graaf
              Postal: 3Com Corporation
                      118 Turnpike Rd.
                      Southborough, MA  01772
                      USA
                 Tel: (508)229-1627
                 Fax: (508)490-5882
              E-mail: [email protected]"
      DESCRIPTION
              "Management information for 802.3 MAUs.

              The following references are used throughout this
              MIB module:

              [IEEE 802.3 Std]
                 refers to IEEE 802.3/ISO 8802-3 Information
                 processing systems - Local area networks -
                 Part 3: Carrier sense multiple access with
                 collision detection (CSMA/CD) access method
                 and physical layer specifications (1993),
                 and to IEEE Std 802.3u-1995, Supplement to
                 IEEE Std 802.3, clauses 22 through 29.

              [IEEE 802.3 Mgt]
                 refers to IEEE 802.3u-1995, - 10 Mb/s &
                 100 Mb/s Management, Section 30 -
                 Supplement to IEEE Std 802.3."
      ::= { snmpDot3MauMgt 6 }





de Graaf, et. al.           Standards Track                     [Page 5]

RFC 2239          Managed Objects for IEEE 802.3 MAUs      November 1997


  snmpDot3MauMgt OBJECT IDENTIFIER ::= { mib-2 26 }


  -- textual conventions

  JackType ::= TEXTUAL-CONVENTION
      STATUS     current
      DESCRIPTION
              "Common enumeration values for repeater and
              interface MAU jack types."
      SYNTAX     INTEGER {
                     other(1),
                     rj45(2),
                     rj45S(3), -- rj45 shielded
                     db9(4),
                     bnc(5),
                     fAUI(6),  -- female aui
                     mAUI(7),  -- male aui
                     fiberSC(8),
                     fiberMIC(9),
                     fiberST(10),
                     telco(11)
                 }


  dot3RpMauBasicGroup         OBJECT IDENTIFIER ::= { snmpDot3MauMgt 1 }
  dot3IfMauBasicGroup         OBJECT IDENTIFIER ::= { snmpDot3MauMgt 2 }
  dot3BroadMauBasicGroup      OBJECT IDENTIFIER ::= { snmpDot3MauMgt 3 }

  dot3IfMauAutoNegGroup       OBJECT IDENTIFIER ::= { snmpDot3MauMgt 5 }

  -- object identities for MAU types
  --  (see rpMauType and ifMauType for usage)

  dot3MauType
      OBJECT IDENTIFIER ::= { snmpDot3MauMgt 4 }

  dot3MauTypeAUI OBJECT-IDENTITY
      STATUS     current
      DESCRIPTION
              "no internal MAU, view from AUI"
      ::= { dot3MauType 1 }

  dot3MauType10Base5 OBJECT-IDENTITY
      STATUS     current
      DESCRIPTION
              "thick coax MAU (per 802.3 section 8)"
      ::= { dot3MauType 2 }



de Graaf, et. al.           Standards Track                     [Page 6]

RFC 2239          Managed Objects for IEEE 802.3 MAUs      November 1997


  dot3MauTypeFoirl OBJECT-IDENTITY
      STATUS     current
      DESCRIPTION
              "FOIRL MAU (per 802.3 section 9.9)"
      ::= { dot3MauType 3 }

  dot3MauType10Base2 OBJECT-IDENTITY
      STATUS     current
      DESCRIPTION
              "thin coax MAU (per 802.3 section 10)"
      ::= { dot3MauType 4 }

  dot3MauType10BaseT OBJECT-IDENTITY
      STATUS     current
      DESCRIPTION
              "UTP MAU (per 802.3 section 14)"
      ::= { dot3MauType 5 }

  dot3MauType10BaseFP OBJECT-IDENTITY
      STATUS     current
      DESCRIPTION
              "passive fiber MAU (per 802.3 section 16)"
      ::= { dot3MauType 6 }

  dot3MauType10BaseFB OBJECT-IDENTITY
      STATUS     current
      DESCRIPTION
              "sync fiber MAU (per 802.3 section 17)"
      ::= { dot3MauType 7 }

  dot3MauType10BaseFL OBJECT-IDENTITY
      STATUS     current
      DESCRIPTION
              "async fiber MAU (per 802.3 section 18)"
      ::= { dot3MauType 8 }

  dot3MauType10Broad36 OBJECT-IDENTITY
      STATUS     current
      DESCRIPTION
              "broadband DTE MAU (per 802.3 section 11). Note
              that 10BROAD36 MAUs can be attached to interfaces
              but not to repeaters."
      ::= { dot3MauType 9 }

  ------ new since RFC 1515:

  dot3MauType10BaseTHD OBJECT-IDENTITY
      STATUS     current



de Graaf, et. al.           Standards Track                     [Page 7]

RFC 2239          Managed Objects for IEEE 802.3 MAUs      November 1997


      DESCRIPTION
              "UTP MAU (per 802.3 section 14), half duplex mode"
      ::= { dot3MauType 10 }

  dot3MauType10BaseTFD OBJECT-IDENTITY
      STATUS     current
      DESCRIPTION
              "UTP MAU (per 802.3 section 14), full duplex mode"
      ::= { dot3MauType 11 }

  dot3MauType10BaseFLHD OBJECT-IDENTITY
      STATUS     current
      DESCRIPTION
              "async fiber MAU (per 802.3 section 18), half
              duplex mode"
      ::= { dot3MauType 12 }

  dot3MauType10BaseFLFD OBJECT-IDENTITY
      STATUS     current
      DESCRIPTION
              "async fiber MAU (per 802.3 section 18), full
              duplex mode"
      ::= { dot3MauType 13 }

  dot3MauType100BaseT4 OBJECT-IDENTITY
      STATUS     current
      DESCRIPTION
              "4 pair categ. 3 UTP (per 802.3 section 23)"
      ::= { dot3MauType 14 }

  dot3MauType100BaseTXHD OBJECT-IDENTITY
      STATUS     current
      DESCRIPTION
              "2 pair categ. 5 UTP (per 802.3 section 25), half
              duplex mode"
      ::= { dot3MauType 15 }

  dot3MauType100BaseTXFD OBJECT-IDENTITY
      STATUS     current
      DESCRIPTION
              "2 pair categ. 5 UTP (per 802.3 section 25), full
              duplex mode"
      ::= { dot3MauType 16 }

  dot3MauType100BaseFXHD OBJECT-IDENTITY
      STATUS     current
      DESCRIPTION
              "X fiber over PMT (per 802.3 section 26), half



de Graaf, et. al.           Standards Track                     [Page 8]

RFC 2239          Managed Objects for IEEE 802.3 MAUs      November 1997


              duplex mode"
      ::= { dot3MauType 17 }

  dot3MauType100BaseFXFD OBJECT-IDENTITY
      STATUS     current
      DESCRIPTION
              "X fiber over PMT (per 802.3 section 26), full
              duplex mode"
      ::= { dot3MauType 18 }

  dot3MauType100BaseT2HD OBJECT-IDENTITY
      STATUS     current
      DESCRIPTION
              "2 pair categ. 3 UTP (per 802.3 section 32), half
              duplex mode"
      ::= { dot3MauType 19 }

  dot3MauType100BaseT2FD OBJECT-IDENTITY
      STATUS     current
      DESCRIPTION
              "2 pair categ. 3 UTP (per 802.3 section 32), full
              duplex mode"
      ::= { dot3MauType 20 }


  --
  -- The Basic Repeater MAU Table
  --

  rpMauTable OBJECT-TYPE
      SYNTAX     SEQUENCE OF RpMauEntry
      MAX-ACCESS not-accessible
      STATUS     current
      DESCRIPTION
              "Table of descriptive and status information about
              the MAU(s) attached to the ports of a repeater."
      ::= { dot3RpMauBasicGroup 1 }

  rpMauEntry OBJECT-TYPE
      SYNTAX     RpMauEntry
      MAX-ACCESS not-accessible
      STATUS     current
      DESCRIPTION
              "An entry in the table, containing information
              about a single MAU."
      INDEX      { rpMauGroupIndex, rpMauPortIndex, rpMauIndex }
      ::= { rpMauTable 1 }




de Graaf, et. al.           Standards Track                     [Page 9]

RFC 2239          Managed Objects for IEEE 802.3 MAUs      November 1997


  RpMauEntry ::=
      SEQUENCE {
          rpMauGroupIndex
              Integer32,
          rpMauPortIndex
              Integer32,
          rpMauIndex
              Integer32,
          rpMauType
              OBJECT IDENTIFIER,
          rpMauStatus
              INTEGER,
          rpMauMediaAvailable
              INTEGER,
          rpMauMediaAvailableStateExits
              Counter32,
          rpMauJabberState
              INTEGER,
          rpMauJabberingStateEnters
              Counter32,
          rpMauFalseCarriers
              Counter32
      }

  rpMauGroupIndex OBJECT-TYPE
      SYNTAX     Integer32 (1..2147483647)
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
              "This variable uniquely identifies the group
              containing the port to which the MAU described by
              this entry is connected.

              Note:  In practice, a group will generally be a
              field-replaceable unit (i.e., module, card, or
              board) that can fit in the physical system
              enclosure, and the group number will correspond to
              a number marked on the physical enclosure.

              The group denoted by a particular value of this
              object is the same as the group denoted by the
              same value of rptrGroupIndex."
      ::= { rpMauEntry 1 }

  rpMauPortIndex OBJECT-TYPE
      SYNTAX     Integer32 (1..2147483647)
      MAX-ACCESS read-only
      STATUS     current



de Graaf, et. al.           Standards Track                    [Page 10]

RFC 2239          Managed Objects for IEEE 802.3 MAUs      November 1997


      DESCRIPTION
              "This variable uniquely identifies the repeater
              port within group rpMauGroupIndex to which the MAU
              described by this entry is connected."
      REFERENCE
              "Reference RFC 1516, rptrPortIndex."
      ::= { rpMauEntry 2 }

  rpMauIndex OBJECT-TYPE
      SYNTAX     Integer32 (1..2147483647)
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
              "This variable uniquely identifies the MAU
              described by this entry from among other MAUs
              connected to the same port (rpMauPortIndex)."
      REFERENCE
              "[IEEE 802.3 Mgt], 30.5.1.1.1, aMAUID."
      ::= { rpMauEntry 3 }

  rpMauType OBJECT-TYPE
      SYNTAX     OBJECT IDENTIFIER
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
              "This object identifies the 10 or 100 Mb/s
              baseband MAU type.  An initial set of MAU types
              are defined above.  The assignment of OBJECT
              IDENTIFIERs to new types of MAUs is managed by the
              IANA.  If the MAU type is unknown, the object
              identifier

              unknownMauType OBJECT IDENTIFIER ::= { 0 0 }

              is returned.  Note that unknownMauType is a
              syntactically valid object identifier, and any
              conformant implementation of ASN.1 and the BER
              must be able to generate and recognize this
              value."
      REFERENCE
              "[IEEE 802.3 Mgt], 30.5.1.1.2, aMAUType."
      ::= { rpMauEntry 4 }

  rpMauStatus OBJECT-TYPE
      SYNTAX     INTEGER {
                     other(1),
                     unknown(2),
                     operational(3),



de Graaf, et. al.           Standards Track                    [Page 11]

RFC 2239          Managed Objects for IEEE 802.3 MAUs      November 1997


                     standby(4),
                     shutdown(5),
                     reset(6)
                 }
      MAX-ACCESS read-write
      STATUS     current
      DESCRIPTION
              "The current state of the MAU.  This object may be
              implemented as a read-only object by those agents
              and MAUs that do not implement software control of
              the MAU state.  Some agents may not support
              setting the value of this object to some of the
              enumerated values.

              The value other(1) is returned if the MAU is in a
              state other than one of the states 2 through 6.

              The value unknown(2) is returned when the MAU's
              true state is unknown; for example, when it is
              being initialized.

              A MAU in the operational(3) state is fully
              functional, operates, and passes signals to its
              attached DTE or repeater port in accordance to its
              specification.

              A MAU in standby(4) state forces DI and CI to idle
              and the media transmitter to idle or fault, if
              supported.  Standby(4) mode only applies to link
              type MAUs.  The state of rpMauMediaAvailable is
              unaffected.

              A MAU in shutdown(5) state assumes the same
              condition on DI, CI, and the media transmitter as
              though it were powered down or not connected.  The
              MAU may return other(1) value for the
              rpMauJabberState and rpMauMediaAvailable objects
              when it is in this state.  For an AUI, this state
              will remove power from the AUI.

              Setting this variable to the value reset(6) resets
              the MAU in the same manner as a power-off, power-
              on cycle of at least one-half second would.  The
              agent is not required to return the value reset
              (6).

              Setting this variable to the value operational(3),
              standby(4), or shutdown(5) causes the MAU to



de Graaf, et. al.           Standards Track                    [Page 12]

RFC 2239          Managed Objects for IEEE 802.3 MAUs      November 1997


              assume the respective state except that setting a
              mixing-type MAU or an AUI to standby(4) will cause
              the MAU to enter the shutdown state."
      REFERENCE
              "[IEEE 802.3 Mgt], 30.5.1.1.7, aMAUAdminState,
              30.5.1.2.2, acMAUAdminControl, and 30.5.1.2.1,
              acRESETMAU."
      ::= { rpMauEntry 5 }

  rpMauMediaAvailable OBJECT-TYPE
      SYNTAX     INTEGER {
                     other(1),
                     unknown(2),
                     available(3),
                     notAvailable(4),
                     remoteFault(5),
                     invalidSignal(6),
                     remoteJabber(7),
                     remoteLinkLoss(8),
                     remoteTest(9)
                 }
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
              "If the MAU is a link or fiber type (FOIRL,
              10BASE-T, 10BASE-F) then this is equivalent to the
              link test fail state/low light function.  For an
              AUI or a coax (including broadband) MAU this
              indicates whether or not loopback is detected on
              the DI circuit.  The value of this attribute
              persists between packets for MAU types AUI,
              10BASE5, 10BASE2, 10BROAD36, and 10BASE-FP.

              The value other(1) is returned if the
              mediaAvailable state is not one of 2 through 6.

              The value unknown(2) is returned when the MAU's
              true state is unknown; for example, when it is
              being initialized.  At power-up or following a
              reset, the value of this attribute will be unknown
              for AUI, coax, and 10BASE-FP MAUs.  For these MAUs
              loopback will be tested on each transmission
              during which no collision is detected.  If DI is
              receiving input when DO returns to IDL after a
              transmission and there has been no collision
              during the transmission then loopback will be
              detected.  The value of this attribute will only
              change during non-collided transmissions for AUI,



de Graaf, et. al.           Standards Track                    [Page 13]

RFC 2239          Managed Objects for IEEE 802.3 MAUs      November 1997


              coax, and 10BASE-FP MAUs.

              For 100BASE-T4, 100BASE-TX and 100BASE-FX the
              enumerations match the states within the
              respective link integrity state diagrams, fig 23-
              12 and 24-15 of sections 23 and 24 of [2].  Any
              MAU which implements management of auto-
              negotiation will map remote fault indication to
              remote fault.

              The value available(3) indicates that the link,
              light, or loopback is normal.  The value
              notAvailable(4) indicates link loss, low light, or
              no loopback.

              The value remoteFault(5) indicates that a fault
              has been detected at the remote end of the link.
              This value applies to 10BASE-FB, 100BASE-T4 Far
              End Fault Indication and non-specified remote
              faults from a system running auto-negotiation.
              The values remoteJabber(7), remoteLinkLoss(8), and
              remoteTest(9) should be used instead of
              remoteFault(5) where the reason for remote fault
              is identified in the remote signaling protocol.

              The value invalidSignal(6) indicates that an
              invalid signal has been received from the other
              end of the link.  InvalidSignal(6) applies only to
              MAUs of type 10BASE-FB.

              Where an IEEE Std 802.3u-1995 clause 22 MII is
              present, a logic one in the remote fault bit
              (reference section 22.2.4.2.8 of that document)
              maps to the value remoteFault(5), and a logic zero
              in the link status bit (reference section
              22.2.4.2.10 of that document) maps to the value
              notAvailable(4).  The value notAvailable(4) takes
              precedence over the value remoteFault(5)."
      REFERENCE
              "[IEEE 802.3 Mgt], 30.5.1.1.4, aMediaAvailable."
      ::= { rpMauEntry 6 }

  rpMauMediaAvailableStateExits OBJECT-TYPE
      SYNTAX     Counter32
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
              "A count of the number of times that



de Graaf, et. al.           Standards Track                    [Page 14]

RFC 2239          Managed Objects for IEEE 802.3 MAUs      November 1997


              rpMauMediaAvailable for this MAU instance leaves
              the state available(3)."
      REFERENCE
              "[IEEE 802.3 Mgt], 30.5.1.1.5, aLoseMediaCounter."
      ::= { rpMauEntry 7 }

  rpMauJabberState OBJECT-TYPE
      SYNTAX     INTEGER {
                     other(1),
                     unknown(2),
                     noJabber(3),
                     jabbering(4)
                 }
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
              "The value other(1) is returned if the jabber
              state is not 2, 3, or 4.  The agent must always
              return other(1) for MAU type dot3MauTypeAUI.

              The value unknown(2) is returned when the MAU's
              true state is unknown; for example, when it is
              being initialized.

              If the MAU is not jabbering the agent returns
              noJabber(3).  This is the 'normal' state.

              If the MAU is in jabber state the agent returns
              the jabbering(4) value."
      REFERENCE
              "[IEEE 802.3 Mgt], 30.5.1.1.6,
              aJabber.jabberFlag."
      ::= { rpMauEntry 8 }

  rpMauJabberingStateEnters OBJECT-TYPE
      SYNTAX     Counter32
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
              "A count of the number of times that
              mauJabberState for this MAU instance enters the
              state jabbering(4).  For MAUs of type
              dot3MauTypeAUI, dot3MauType100BaseT4,
              dot3MauType100BaseTX, and dot3MauType100BaseFX,
              this counter will always indicate zero."
      REFERENCE
              "[IEEE 802.3 Mgt], 30.5.1.1.6,
              aJabber.jabberCounter."



de Graaf, et. al.           Standards Track                    [Page 15]

RFC 2239          Managed Objects for IEEE 802.3 MAUs      November 1997


      ::= { rpMauEntry 9 }

  rpMauFalseCarriers OBJECT-TYPE
      SYNTAX     Counter32
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
              "A count of the number of false carrier events
              during IDLE in 100BASE-X links.  This counter does
              not increment at the symbol rate.  It can
              increment after a valid carrier completion at a
              maximum rate of once per 100 ms until the next
              carrier event.

              This counter increments only for MAUs of type
              dot3MauType100BaseT4, dot3MauType100BaseTX, and
              dot3MauType100BaseFX.  For all other MAU types,
              this counter will always indicate zero.

              The approximate minimum time for rollover of this
              counter is 7.4 hours."
      REFERENCE
              "[IEEE 802.3 Mgt], 30.5.1.1.10, aFalseCarriers."
      ::= { rpMauEntry 10 }


  -- The rpJackTable applies to MAUs attached to repeaters
  -- which have one or more external jacks (connectors).

  rpJackTable OBJECT-TYPE
      SYNTAX     SEQUENCE OF RpJackEntry
      MAX-ACCESS not-accessible
      STATUS     current
      DESCRIPTION
              "Information about the external jacks attached to
              MAUs attached to the ports of a repeater."
      ::= { dot3RpMauBasicGroup 2 }

  rpJackEntry OBJECT-TYPE
      SYNTAX     RpJackEntry
      MAX-ACCESS not-accessible
      STATUS     current
      DESCRIPTION
              "An entry in the table, containing information
              about a particular jack."

      INDEX    { rpMauGroupIndex,
                 rpMauPortIndex,



de Graaf, et. al.           Standards Track                    [Page 16]

RFC 2239          Managed Objects for IEEE 802.3 MAUs      November 1997


                 rpMauIndex,
                 rpJackIndex }
      ::= { rpJackTable 1 }

  RpJackEntry ::=
      SEQUENCE {
          rpJackIndex
              Integer32,
          rpJackType
              JackType
      }

  rpJackIndex OBJECT-TYPE
      SYNTAX     Integer32 (1..2147483647)
      MAX-ACCESS not-accessible
      STATUS     current
      DESCRIPTION
              "This variable uniquely identifies the jack
              described by this entry from among other jacks
              attached to the same MAU (rpMauIndex)."
      ::= { rpJackEntry 1 }

  rpJackType OBJECT-TYPE
      SYNTAX     JackType
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
              "The jack connector type, as it appears on the
              outside of the system."
      ::= { rpJackEntry 2 }


  --
  -- The Basic Interface MAU Table
  --

  ifMauTable OBJECT-TYPE
      SYNTAX     SEQUENCE OF IfMauEntry
      MAX-ACCESS not-accessible
      STATUS     current
      DESCRIPTION
              "Table of descriptive and status information about
              MAU(s) attached to an interface."

      ::= { dot3IfMauBasicGroup 1 }

  ifMauEntry OBJECT-TYPE
      SYNTAX     IfMauEntry



de Graaf, et. al.           Standards Track                    [Page 17]

RFC 2239          Managed Objects for IEEE 802.3 MAUs      November 1997


      MAX-ACCESS not-accessible
      STATUS     current
      DESCRIPTION
              "An entry in the table, containing information
              about a single MAU."
      INDEX      { ifMauIfIndex, ifMauIndex }
      ::= { ifMauTable 1 }

  IfMauEntry ::=
      SEQUENCE {
          ifMauIfIndex
              Integer32,
          ifMauIndex
              Integer32,
          ifMauType
              OBJECT IDENTIFIER,
          ifMauStatus
              INTEGER,
          ifMauMediaAvailable
              INTEGER,
          ifMauMediaAvailableStateExits
              Counter32,
          ifMauJabberState
              INTEGER,
          ifMauJabberingStateEnters
              Counter32,
          ifMauFalseCarriers
              Counter32,
          ifMauTypeList
              Integer32,
          ifMauDefaultType
              OBJECT IDENTIFIER,
          ifMauAutoNegSupported
              TruthValue
      }

  ifMauIfIndex OBJECT-TYPE
      SYNTAX     Integer32 (1..2147483647)
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
              "This variable uniquely identifies the interface
              to which the MAU described by this entry is
              connected."
      REFERENCE
              "RFC 1213, ifIndex"
      ::= { ifMauEntry 1 }




de Graaf, et. al.           Standards Track                    [Page 18]

RFC 2239          Managed Objects for IEEE 802.3 MAUs      November 1997


  ifMauIndex OBJECT-TYPE
      SYNTAX     Integer32 (1..2147483647)
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
              "This variable uniquely identifies the MAU
              described by this entry from among other MAUs
              connected to the same interface (ifMauIfIndex)."
      REFERENCE
              "[IEEE 802.3 Mgt], 30.5.1.1.1, aMAUID."
      ::= { ifMauEntry 2 }

  ifMauType OBJECT-TYPE
      SYNTAX     OBJECT IDENTIFIER
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
              "This object identifies the 10 or 100 Mb/s
              baseband or broadband MAU type.  An initial set of
              MAU types are defined above.  The assignment of
              OBJECT IDENTIFIERs to new types of MAUs is managed
              by the IANA.  If the MAU type is unknown, the
              object identifier

              unknownMauType OBJECT IDENTIFIER ::= { 0 0 }

              is returned.  Note that unknownMauType is a
              syntactically valid object identifier, and any
              conformant implementation of ASN.1 and the BER
              must be able to generate and recognize this value.

              This object represents the operational type of the
              MAU, as determined by either (1) the result of the
              auto-negotiation function or (2) if auto-
              negotiation is not enabled or is not implemented
              for this MAU, by the value of the object
              ifMauDefaultType.  In case (2), a set to the
              object ifMauDefaultType will force the MAU into
              the new operating mode."
      REFERENCE
              "[IEEE 802.3 Mgt], 30.5.1.1.2, aMAUType."
      ::= { ifMauEntry 3 }

  ifMauStatus OBJECT-TYPE
      SYNTAX     INTEGER {
                     other(1),
                     unknown(2),
                     operational(3),



de Graaf, et. al.           Standards Track                    [Page 19]

RFC 2239          Managed Objects for IEEE 802.3 MAUs      November 1997


                     standby(4),
                     shutdown(5),
                     reset(6)
                 }
      MAX-ACCESS read-write
      STATUS     current
      DESCRIPTION
              "The current state of the MAU.  This object may be
              implemented as a read-only object by those agents
              and MAUs that do not implement software control of
              the MAU state.  Some agents may not support
              setting the value of this object to some of the
              enumerated values.

              The value other(1) is returned if the MAU is in a
              state other than one of the states 2 through 6.

              The value unknown(2) is returned when the MAU's
              true state is unknown; for example, when it is
              being initialized.

              A MAU in the operational(3) state is fully
              functional, operates, and passes signals to its
              attached DTE or repeater port in accordance to its
              specification.

              A MAU in standby(4) state forces DI and CI to idle
              and the media transmitter to idle or fault, if
              supported.  Standby(4) mode only applies to link
              type MAUs.  The state of ifMauMediaAvailable is
              unaffected.

              A MAU in shutdown(5) state assumes the same
              condition on DI, CI, and the media transmitter as
              though it were powered down or not connected.  The
              MAU may return other(1) value for the
              ifMauJabberState and ifMauMediaAvailable objects
              when it is in this state.  For an AUI, this state
              will remove power from the AUI.

              Setting this variable to the value reset(6) resets
              the MAU in the same manner as a power-off, power-
              on cycle of at least one-half second would.  The
              agent is not required to return the value reset
              (6).

              Setting this variable to the value operational(3),
              standby(4), or shutdown(5) causes the MAU to



de Graaf, et. al.           Standards Track                    [Page 20]

RFC 2239          Managed Objects for IEEE 802.3 MAUs      November 1997


              assume the respective state except that setting a
              mixing-type MAU or an AUI to standby(4) will cause
              the MAU to enter the shutdown state."
      REFERENCE
              "[IEEE 802.3 Mgt], 30.5.1.1.7, aMAUAdminState,
              30.5.1.2.2, acMAUAdminControl, and 30.5.1.2.1,
              acRESETMAU."
      ::= { ifMauEntry 4 }

  ifMauMediaAvailable OBJECT-TYPE
      SYNTAX     INTEGER {
                     other(1),
                     unknown(2),
                     available(3),
                     notAvailable(4),
                     remoteFault(5),
                     invalidSignal(6),
                     remoteJabber(7),
                     remoteLinkLoss(8),
                     remoteTest(9)
                 }
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
              "If the MAU is a link or fiber type (FOIRL,
              10BASE-T, 10BASE-F) then this is equivalent to the
              link test fail state/low light function.  For an
              AUI or a coax (including broadband) MAU this
              indicates whether or not loopback is detected on
              the DI circuit.  The value of this attribute
              persists between packets for MAU types AUI,
              10BASE5, 10BASE2, 10BROAD36, and 10BASE-FP.

              The value other(1) is returned if the
              mediaAvailable state is not one of 2 through 6.

              The value unknown(2) is returned when the MAU's
              true state is unknown; for example, when it is
              being initialized.  At power-up or following a
              reset, the value of this attribute will be unknown
              for AUI, coax, and 10BASE-FP MAUs.  For these MAUs
              loopback will be tested on each transmission
              during which no collision is detected.  If DI is
              receiving input when DO returns to IDL after a
              transmission and there has been no collision
              during the transmission then loopback will be
              detected.  The value of this attribute will only
              change during non-collided transmissions for AUI,



de Graaf, et. al.           Standards Track                    [Page 21]

RFC 2239          Managed Objects for IEEE 802.3 MAUs      November 1997


              coax, and 10BASE-FP MAUs.

              For 100BASE-T4, 100BASE-TX and 100BASE-FX the
              enumerations match the states within the
              respective link integrity state diagrams, fig 23-
              12 and 24-15 of sections 23 and 24 of [2].  Any
              MAU which implements management of auto-
              negotiation will map remote fault indication to
              remote fault.

              The value available(3) indicates that the link,
              light, or loopback is normal.  The value
              notAvailable(4) indicates link loss, low light, or
              no loopback.

              The value remoteFault(5) indicates that a fault
              has been detected at the remote end of the link.
              This value applies to 10BASE-FB, 100BASE-T4 Far
              End Fault Indication and non-specified remote
              faults from a system running auto-negotiation.
              The values remoteJabber(7), remoteLinkLoss(8), and
              remoteTest(9) should be used instead of
              remoteFault(5) where the reason for remote fault
              is identified in the remote signaling protocol.

              The value invalidSignal(6) indicates that an
              invalid signal has been received from the other
              end of the link.  InvalidSignal(6) applies only to
              MAUs of type 10BASE-FB.

              Where an IEEE Std 802.3u-1995 clause 22 MII is
              present, a logic one in the remote fault bit
              (reference section 22.2.4.2.8 of that document)
              maps to the value remoteFault(5), and a logic zero
              in the link status bit (reference section
              22.2.4.2.10 of that document) maps to the value
              notAvailable(4).  The value notAvailable(4) takes
              precedence over the value remoteFault(5)."
      REFERENCE
              "[IEEE 802.3 Mgt], 30.5.1.1.4, aMediaAvailable."
      ::= { ifMauEntry 5 }

  ifMauMediaAvailableStateExits OBJECT-TYPE
      SYNTAX     Counter32
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
              "A count of the number of times that



de Graaf, et. al.           Standards Track                    [Page 22]

RFC 2239          Managed Objects for IEEE 802.3 MAUs      November 1997


              ifMauMediaAvailable for this MAU instance leaves
              the state available(3)."
      REFERENCE
              "[IEEE 802.3 Mgt], 30.5.1.1.5, aLoseMediaCounter."
      ::= { ifMauEntry 6 }

  ifMauJabberState OBJECT-TYPE
      SYNTAX     INTEGER {
                     other(1),
                     unknown(2),
                     noJabber(3),
                     jabbering(4)
                 }
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
              "The value other(1) is returned if the jabber
              state is not 2, 3, or 4.  The agent must always
              return other(1) for MAU type dot3MauTypeAUI.

              The value unknown(2) is returned when the MAU's
              true state is unknown; for example, when it is
              being initialized.

              If the MAU is not jabbering the agent returns
              noJabber(3).  This is the 'normal' state.

              If the MAU is in jabber state the agent returns
              the jabbering(4) value."
      REFERENCE
              "[IEEE 802.3 Mgt], 30.5.1.1.6,
              aJabber.jabberFlag."
      ::= { ifMauEntry 7 }

  ifMauJabberingStateEnters OBJECT-TYPE
      SYNTAX     Counter32
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
              "A count of the number of times that
              mauJabberState for this MAU instance enters the
              state jabbering(4).  For MAUs of type
              dot3MauTypeAUI, dot3MauType100BaseT4,
              dot3MauType100BaseTX, and dot3MauType100BaseFX,
              this counter will always indicate zero."
      REFERENCE
              "[IEEE 802.3 Mgt], 30.5.1.1.6,
              aJabber.jabberCounter."



de Graaf, et. al.           Standards Track                    [Page 23]

RFC 2239          Managed Objects for IEEE 802.3 MAUs      November 1997


      ::= { ifMauEntry 8 }

  ifMauFalseCarriers OBJECT-TYPE
      SYNTAX     Counter32
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
              "A count of the number of false carrier events
              during IDLE in 100BASE-X links.  This counter does
              not increment at the symbol rate.  It can
              increment after a valid carrier completion at a
              maximum rate of once per 100 ms until the next
              carrier event.

              This counter increments only for MAUs of type
              dot3MauType100BaseT4, dot3MauType100BaseTX, and
              dot3MauType100BaseFX.  For all other MAU types,
              this counter will always indicate zero.

              The approximate minimum time for rollover of this
              counter is 7.4 hours."
      REFERENCE
              "[IEEE 802.3 Mgt], 30.5.1.1.10, aFalseCarriers."
      ::= { ifMauEntry 9 }

  ifMauTypeList OBJECT-TYPE
      SYNTAX     Integer32
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
              "A value that uniquely identifies the set of
              possible IEEE 802.3 types that the MAU could be.
              The value is a sum which initially takes the value
              zero.  Then, for each type capability of this MAU,
              2 raised to the power noted below is added to the
              sum. For example, a MAU which has the capability
              to be only 10BASE-T would have a value of 512
              (2**9).  In contrast, a MAU which supports both
              10Base-T (full duplex) and 100BASE-TX (full
              duplex) would have a value of ((2**11) + (2**16))
              or 67584.

              The powers of 2 assigned to the capabilities are
              these:

              Power  Capability
                0      other or unknown
                1      AUI



de Graaf, et. al.           Standards Track                    [Page 24]

RFC 2239          Managed Objects for IEEE 802.3 MAUs      November 1997


                2      10BASE-5
                3      FOIRL
                4      10BASE-2
                5      10BASE-T duplex mode unknown
                6      10BASE-FP
                7      10BASE-FB
                8      10BASE-FL duplex mode unknown
                9      10BROAD36
               10      10BASE-T  half duplex mode
               11      10BASE-T  full duplex mode
               12      10BASE-FL half duplex mode
               13      10BASE-FL full duplex mode
               14      100BASE-T4
               15      100BASE-TX half duplex mode
               16      100BASE-TX full duplex mode
               17      100BASE-FX half duplex mode
               18      100BASE-FX full duplex mode
               19      100BASE-T2 half duplex mode
               20      100BASE-T2 full duplex mode

              If auto-negotiation is present on this MAU, this
              object will map to ifMauAutoNegCapability."

      ::= { ifMauEntry 10 }

  ifMauDefaultType OBJECT-TYPE
      SYNTAX     OBJECT IDENTIFIER
      MAX-ACCESS read-write
      STATUS     current
      DESCRIPTION
              "This object identifies the default administrative
              10 or 100 Mb/s baseband MAU type, to be used in
              conjunction with the operational MAU type denoted
              by ifMauType.

              The set of possible values for this object is the
              same as the set defined for the ifMauType object.

              This object represents the administratively-
              configured type of the MAU.  If auto-negotiation
              is not enabled or is not implemented for this MAU,
              the value of this object determines the
              operational type of the MAU.  In this case, a set
              to this object will force the MAU into the
              specified operating mode.

              If auto-negotiation is implemented and enabled for
              this MAU, the operational type of the MAU is



de Graaf, et. al.           Standards Track                    [Page 25]

RFC 2239          Managed Objects for IEEE 802.3 MAUs      November 1997


              determined by auto-negotiation, and the value of
              this object denotes the type to which the MAU will
              automatically revert if/when auto-negotiation is
              later disabled.

              NOTE TO IMPLEMENTORS:  It may be necessary to
              provide for underlying hardware implementations
              which do not follow the exact behavior specified
              above.  In particular, when
              ifMauAutoNegAdminStatus transitions from enabled
              to disabled, the agent implementation must ensure
              that the operational type of the MAU (as reported
              by ifMauType) correctly transitions to the value
              specified by this object, rather than continuing
              to operate at the value earlier determined by the
              auto-negotiation function."
      REFERENCE
              "[IEEE 802.3 Mgt], 30.5.1.1.1, aMAUID, and [IEEE
              802.3 Std], 22.2.4.1.4."
      ::= { ifMauEntry 11 }

  ifMauAutoNegSupported OBJECT-TYPE
      SYNTAX     TruthValue
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
              "This object indicates whether or not auto-
              negotiation is supported on this MAU."
      ::= { ifMauEntry 12 }



  -- The ifJackTable applies to MAUs attached to interfaces
  -- which have one or more external jacks (connectors).

  ifJackTable OBJECT-TYPE
      SYNTAX     SEQUENCE OF IfJackEntry
      MAX-ACCESS not-accessible
      STATUS     current
      DESCRIPTION
              "Information about the external jacks attached to
              MAUs attached to an interface."
      ::= { dot3IfMauBasicGroup 2 }

  ifJackEntry OBJECT-TYPE
      SYNTAX     IfJackEntry
      MAX-ACCESS not-accessible
      STATUS     current



de Graaf, et. al.           Standards Track                    [Page 26]

RFC 2239          Managed Objects for IEEE 802.3 MAUs      November 1997


      DESCRIPTION
              "An entry in the table, containing information
              about a particular jack."
      INDEX    { ifMauIfIndex,
                 ifMauIndex,
                 ifJackIndex }
      ::= { ifJackTable 1 }

  IfJackEntry ::=
      SEQUENCE {
          ifJackIndex
              Integer32,
          ifJackType
              JackType
      }


  ifJackIndex OBJECT-TYPE
      SYNTAX     Integer32 (1..2147483647)
      MAX-ACCESS not-accessible
      STATUS     current
      DESCRIPTION
              "This variable uniquely identifies the jack
              described by this entry from among other jacks
              attached to the same MAU."
      ::= { ifJackEntry 1 }

  ifJackType OBJECT-TYPE
      SYNTAX     JackType
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
              "The jack connector type, as it appears on the
              outside of the system."
      ::= { ifJackEntry 2 }


  -- The ifMauAutoNegTable applies to systems in which
  -- auto-negotiation is supported on one or more MAUs
  -- attached to interfaces.  Note that if auto-negotiation
  -- is present and enabled, the ifMauType object reflects
  -- the result of the auto-negotiation function.

  ifMauAutoNegTable OBJECT-TYPE
      SYNTAX     SEQUENCE OF IfMauAutoNegEntry
      MAX-ACCESS not-accessible
      STATUS     current
      DESCRIPTION



de Graaf, et. al.           Standards Track                    [Page 27]

RFC 2239          Managed Objects for IEEE 802.3 MAUs      November 1997


              "Configuration and status objects for the auto-
              negotiation function of MAUs attached to
              interfaces."
      ::= { dot3IfMauAutoNegGroup 1 }

  ifMauAutoNegEntry OBJECT-TYPE
      SYNTAX     IfMauAutoNegEntry
      MAX-ACCESS not-accessible
      STATUS     current
      DESCRIPTION
              "An entry in the table, containing configuration
              and status information for the auto-negotiation
              function of a particular MAU."
          INDEX     { ifMauIfIndex, ifMauIndex }
      ::= { ifMauAutoNegTable 1 }

  IfMauAutoNegEntry ::=
      SEQUENCE {
          ifMauAutoNegAdminStatus
              INTEGER,
          ifMauAutoNegRemoteSignaling
              INTEGER,
          ifMauAutoNegConfig
              INTEGER,
          ifMauAutoNegCapability
              Integer32,
          ifMauAutoNegCapAdvertised
              Integer32,
          ifMauAutoNegCapReceived
              Integer32,
          ifMauAutoNegRestart
              INTEGER

      }


  ifMauAutoNegAdminStatus OBJECT-TYPE
      SYNTAX     INTEGER {
                     enabled(1),
                     disabled(2)
                 }
      MAX-ACCESS read-write
      STATUS     current
      DESCRIPTION
              "Setting this object to enabled(1) will cause the
              interface which has the auto-negotiation signaling
              ability to be enabled.




de Graaf, et. al.           Standards Track                    [Page 28]

RFC 2239          Managed Objects for IEEE 802.3 MAUs      November 1997


              If the value of this object is disabled(2) then
              the interface will act as it would if it had no
              auto-negotiation signaling.  Under these
              conditions, an IEEE 802.3 MAU will immediately be
              forced to the state indicated by the value of the
              object ifMauDefaultType.

              NOTE TO IMPLEMENTORS:  When
              ifMauAutoNegAdminStatus transitions from enabled
              to disabled, the agent implementation must ensure
              that the operational type of the MAU (as reported
              by ifMauType) correctly transitions to the value
              specified by the ifMauDefaultType object, rather
              than continuing to operate at the value earlier
              determined by the auto-negotiation function."
      REFERENCE
              "[IEEE 802.3 Mgt], 30.6.1.1.2, aAutoNegAdminState
              and 30.6.1.2.2, acAutoNegAdminControl."
      ::= { ifMauAutoNegEntry 1 }

  ifMauAutoNegRemoteSignaling OBJECT-TYPE
      SYNTAX     INTEGER {
                     detected(1),
                     notdetected(2)
                 }
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
              "A value indicating whether the remote end of the
              link is using auto-negotiation signaling. It takes
              the value detected(1) if and only if, during the
              previous link negotiation, FLP Bursts were
              received."
      REFERENCE
              "[IEEE 802.3 Mgt], 30.6.1.1.3,
              aAutoNegRemoteSignaling."
      ::= { ifMauAutoNegEntry 2 }

  ifMauAutoNegConfig OBJECT-TYPE
      SYNTAX     INTEGER {
                     other(1),
                     configuring(2),
                     complete(3),
                     disabled(4),
                     parallelDetectFail(5)
                 }
      MAX-ACCESS read-only
      STATUS     current



de Graaf, et. al.           Standards Track                    [Page 29]

RFC 2239          Managed Objects for IEEE 802.3 MAUs      November 1997


      DESCRIPTION
              "A value indicating the current status of the
              auto-negotiation process.  The enumeration
              parallelDetectFail(5) maps to a failure in
              parallel detection as defined in 28.2.3.1 of [IEEE
              802.3 Std]."
      REFERENCE
              "[IEEE 802.3 Mgt], 30.6.1.1.4,
              aAutoNegAutoConfig."
      ::= { ifMauAutoNegEntry 4 }

  ifMauAutoNegCapability OBJECT-TYPE
      SYNTAX     Integer32
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
              "A value that uniquely identifies the set of
              capabilities of the local auto-negotiation entity.
              The value is a sum which initially takes the value
              zero.  Then, for each capability of this
              interface, 2 raised to the power noted below is
              added to the sum. For example, an interface which
              has the capability to support only 100Base-TX half
              duplex would have a value of 32768 (2**15).  In
              contrast, an interface which supports both
              100Base-TX half duplex and and 100Base-TX full
              duplex would have a value of 98304 ((2**15) +
              (2**16)).

              The powers of 2 assigned to the capabilities are
              these:

              Power   Capability
                0       other or unknown
               (1-9)    (reserved)
               10       10BASE-T  half duplex mode
               11       10BASE-T  full duplex mode
               12       (reserved)
               13       (reserved)
               14       100BASE-T4
               15       100BASE-TX half duplex mode
               16       100BASE-TX full duplex mode
               17       (reserved)
               18       (reserved)
               19      100BASE-T2 half duplex mode
               20      100BASE-T2 full duplex mode

              Note that interfaces that support this MIB may



de Graaf, et. al.           Standards Track                    [Page 30]

RFC 2239          Managed Objects for IEEE 802.3 MAUs      November 1997


              have capabilities that extend beyond the scope of
              this MIB."
      REFERENCE
              "[IEEE 802.3 Mgt], 30.6.1.1.5,
              aAutoNegLocalTechnologyAbility."
      ::= { ifMauAutoNegEntry 5 }

  ifMauAutoNegCapAdvertised OBJECT-TYPE
      SYNTAX     Integer32
      MAX-ACCESS read-write
      STATUS     current
      DESCRIPTION
              "A value that uniquely identifies the set of
              capabilities advertised by the local auto-
              negotiation entity. Refer to
              ifMauAutoNegCapability for a description of the
              possible values of this object.

              Capabilities in this object that are not available
              in ifMauAutoNegCapability cannot be enabled."
      REFERENCE
              "[IEEE 802.3 Mgt], 30.6.1.1.6,
              aAutoNegAdvertisedTechnologyAbility."
      ::= { ifMauAutoNegEntry 6 }

  ifMauAutoNegCapReceived OBJECT-TYPE
      SYNTAX     Integer32
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
              "A value that uniquely identifies the set of
              capabilities received from the remote auto-
              negotiation entity. Refer to
              ifMauAutoNegCapability for a description of the
              possible values of this object.

              Note that interfaces that support this MIB may be
              attached to remote auto-negotiation entities which
              have capabilities beyond the scope of this MIB."
      REFERENCE
              "[IEEE 802.3 Mgt], 30.6.1.1.7,
              aAutoNegReceivedTechnologyAbility."
      ::= { ifMauAutoNegEntry 7 }

  ifMauAutoNegRestart OBJECT-TYPE
      SYNTAX     INTEGER {
                     restart(1),
                     norestart(2)



de Graaf, et. al.           Standards Track                    [Page 31]

RFC 2239          Managed Objects for IEEE 802.3 MAUs      November 1997


                 }
      MAX-ACCESS read-write
      STATUS     current
      DESCRIPTION
              "If the value of this object is set to restart(1)
              then this will force auto-negotiation to begin
              link renegotiation. If auto-negotiation signaling
              is disabled, a write to this object has no effect.

              Setting the value of this object to norestart(2)
              has no effect."
      REFERENCE
              "[IEEE 802.3 Mgt], 30.6.1.2.1,
              acAutoNegRestartAutoConfig."
      ::= { ifMauAutoNegEntry 8 }


  --
  -- The Basic Broadband MAU Table
  --

  broadMauBasicTable OBJECT-TYPE
      SYNTAX     SEQUENCE OF BroadMauBasicEntry
      MAX-ACCESS not-accessible
      STATUS     current
      DESCRIPTION
              "Table of descriptive and status information about
              the broadband MAUs connected to interfaces."
      ::= { dot3BroadMauBasicGroup 1 }

  broadMauBasicEntry OBJECT-TYPE
      SYNTAX     BroadMauBasicEntry
      MAX-ACCESS not-accessible
      STATUS     current
      DESCRIPTION
              "An entry in the table, containing information
              about a single broadband MAU."
      INDEX     { broadMauIfIndex, broadMauIndex }
      ::= { broadMauBasicTable 1 }

  BroadMauBasicEntry ::=
      SEQUENCE {
          broadMauIfIndex
              Integer32,
          broadMauIndex
              Integer32,
          broadMauXmtRcvSplitType
              INTEGER,



de Graaf, et. al.           Standards Track                    [Page 32]

RFC 2239          Managed Objects for IEEE 802.3 MAUs      November 1997


          broadMauXmtCarrierFreq
              Integer32,
          broadMauTranslationFreq
              Integer32
      }

  broadMauIfIndex OBJECT-TYPE
      SYNTAX     Integer32 (1..2147483647)
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
              "This variable uniquely identifies the interface
              to which the MAU described by this entry is
              connected."
      REFERENCE
              "Reference RFC 1213, ifIndex."
      ::= { broadMauBasicEntry 1 }

  broadMauIndex OBJECT-TYPE
      SYNTAX     Integer32 (1..2147483647)
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
              "This variable uniquely identifies the MAU
              connected to interface broadMauIfIndex that is
              described by this entry."
      REFERENCE
              "Reference IEEE 802.3 MAU Mgt, 20.2.3.2, aMAUID."
      ::= { broadMauBasicEntry 2 }

  broadMauXmtRcvSplitType OBJECT-TYPE
      SYNTAX     INTEGER {
                     other(1),
                     single(2),
                     dual(3)
                 }
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
              "This object indicates the type of frequency
              multiplexing/cabling system used to separate the
              transmit and receive paths for the 10BROAD36 MAU.

              The value other(1) is returned if the split type
              is not either single or dual.

              The value single(2) indicates a single cable
              system.  The value dual(3) indicates a dual cable



de Graaf, et. al.           Standards Track                    [Page 33]

RFC 2239          Managed Objects for IEEE 802.3 MAUs      November 1997


              system, offset normally zero."
      REFERENCE
              "Reference IEEE 802.3 MAU Mgt, 20.2.3.2,
              aBbMAUXmitRcvSplitType."
      ::= { broadMauBasicEntry 3 }

  broadMauXmtCarrierFreq OBJECT-TYPE
      SYNTAX     Integer32
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
              "This variable indicates the transmit carrier
              frequency of the 10BROAD36 MAU in MHz/4; that is,
              in units of 250 kHz."
      REFERENCE
              "Reference IEEE 802.3 MAU Mgt, 20.2.3.2,
              aBroadbandFrequencies.xmitCarrierFrequency."
      ::= { broadMauBasicEntry 4 }

  broadMauTranslationFreq OBJECT-TYPE
      SYNTAX     Integer32
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
              "This variable indicates the translation offset
              frequency of the 10BROAD36 MAU in MHz/4; that is,
              in units of 250 kHz."
      REFERENCE
              "Reference IEEE 802.3 MAU Mgt, 20.2.3.2,
              aBroadbandFrequencies.translationFrequency."
      ::= { broadMauBasicEntry 5 }



  -- Notifications for use by 802.3 MAUs

  rpMauJabberTrap NOTIFICATION-TYPE
      OBJECTS     { rpMauJabberState }
      STATUS      current
      DESCRIPTION
              "This trap is sent whenever a managed repeater MAU
              enters the jabber state.

              The agent must throttle the generation of
              consecutive rpMauJabberTraps so that there is at
              least a five-second gap between them."
      REFERENCE
              "[IEEE 802.3 Mgt], 30.5.1.3.1, nJabber



de Graaf, et. al.           Standards Track                    [Page 34]

RFC 2239          Managed Objects for IEEE 802.3 MAUs      November 1997


              notification."
      ::= { snmpDot3MauMgt 0 1 }

  ifMauJabberTrap NOTIFICATION-TYPE
      OBJECTS     { ifMauJabberState }
      STATUS      current
      DESCRIPTION
              "This trap is sent whenever a managed interface
              MAU enters the jabber state.

              The agent must throttle the generation of
              consecutive ifMauJabberTraps so that there is at
              least a five-second gap between them."
      REFERENCE
              "[IEEE 802.3 Mgt], 30.5.1.3.1, nJabber
              notification."
      ::= { snmpDot3MauMgt 0 2 }


  -- Conformance information

  mauModConf
          OBJECT IDENTIFIER ::= { mauMod 1 }
    mauModCompls
          OBJECT IDENTIFIER ::= { mauModConf 1 }
    mauModObjGrps
          OBJECT IDENTIFIER ::= { mauModConf 2 }
    mauModNotGrps
          OBJECT IDENTIFIER ::= { mauModConf 3 }


  -- Object groups

  mauRpGrpBasic OBJECT-GROUP
      OBJECTS     { rpMauGroupIndex,
                    rpMauPortIndex,
                    rpMauIndex,
                    rpMauType,
                    rpMauStatus,
                    rpMauMediaAvailable,
                    rpMauMediaAvailableStateExits,
                    rpMauJabberState,
                    rpMauJabberingStateEnters }
      STATUS      current
      DESCRIPTION
          "Basic conformance group for MAUs attached to
          repeater ports.  This group is also the
          conformance specification for RFC 1515



de Graaf, et. al.           Standards Track                    [Page 35]

RFC 2239          Managed Objects for IEEE 802.3 MAUs      November 1997


          implementations."
      ::= { mauModObjGrps 1 }

  mauRpGrp100Mbs OBJECT-GROUP
      OBJECTS     { rpMauFalseCarriers }
      STATUS      current
      DESCRIPTION
          "Conformance group for MAUs attached to
          repeater ports with 100 Mb/s capability."
      ::= { mauModObjGrps 2 }

  mauRpGrpJack OBJECT-GROUP
      OBJECTS     { rpJackType }
      STATUS      current
      DESCRIPTION
          "Conformance group for MAUs attached to
          repeater ports with managed jacks."
      ::= { mauModObjGrps 3 }

  mauIfGrpBasic OBJECT-GROUP
      OBJECTS     { ifMauIfIndex,
                    ifMauIndex,
                    ifMauType,
                    ifMauStatus,
                    ifMauMediaAvailable,
                    ifMauMediaAvailableStateExits,
                    ifMauJabberState,
                    ifMauJabberingStateEnters }
      STATUS      current
      DESCRIPTION
          "Basic conformance group for MAUs attached to
          interfaces.  This group also provides a
          conformance specification for RFC 1515
          implementations."
      ::= { mauModObjGrps 4 }

  mauIfGrp100Mbs OBJECT-GROUP
      OBJECTS     { ifMauFalseCarriers,
                    ifMauTypeList,
                    ifMauDefaultType,
                    ifMauAutoNegSupported }
      STATUS      current
      DESCRIPTION
          "Conformance group for MAUs attached
          to interfaces with 100 Mb/s capability."
      ::= { mauModObjGrps 5 }

  mauIfGrpJack OBJECT-GROUP



de Graaf, et. al.           Standards Track                    [Page 36]

RFC 2239          Managed Objects for IEEE 802.3 MAUs      November 1997


      OBJECTS     { ifJackType }
      STATUS      current
      DESCRIPTION
          "Conformance group for MAUs attached
          to interfaces with managed jacks."
      ::= { mauModObjGrps 6 }

  mauIfGrpAutoNeg OBJECT-GROUP
      OBJECTS     { ifMauAutoNegAdminStatus,
                    ifMauAutoNegRemoteSignaling,
                    ifMauAutoNegConfig,
                    ifMauAutoNegCapability,
                    ifMauAutoNegCapAdvertised,
                    ifMauAutoNegCapReceived,
                    ifMauAutoNegRestart }
      STATUS      current
      DESCRIPTION
          "Conformance group for MAUs attached to
          interfaces with managed auto-negotiation."
      ::= { mauModObjGrps 7 }

  mauBroadBasic OBJECT-GROUP
      OBJECTS     { broadMauIfIndex,
                    broadMauIndex,
                    broadMauXmtRcvSplitType,
                    broadMauXmtCarrierFreq,
                    broadMauTranslationFreq }
      STATUS      current
      DESCRIPTION
          "Conformance group for broadband MAUs
          attached to interfaces.  This group
          provides a conformance specification
          for RFC 1515 implementations."
      ::= { mauModObjGrps 8 }

  -- Notification groups

  rpMauNotifications NOTIFICATION-GROUP
      NOTIFICATIONS { rpMauJabberTrap }
      STATUS      current
      DESCRIPTION
          "Notifications for repeater MAUs."
      ::= { mauModNotGrps 1 }

  ifMauNotifications NOTIFICATION-GROUP
      NOTIFICATIONS { ifMauJabberTrap }
      STATUS      current
      DESCRIPTION



de Graaf, et. al.           Standards Track                    [Page 37]

RFC 2239          Managed Objects for IEEE 802.3 MAUs      November 1997


          "Notifications for interface MAUs."
      ::= { mauModNotGrps 2 }


  -- Compliances

  mauModRpCompl MODULE-COMPLIANCE
      STATUS      current
      DESCRIPTION
          "Compliance for MAUs attached to repeater ports."

      MODULE -- this module
          MANDATORY-GROUPS { mauRpGrpBasic }

          GROUP mauRpGrp100Mbs
          DESCRIPTION
              "Implementation of this optional group is
              recommended for MAUs which have 100Mb/s
              capability."

          GROUP mauRpGrpJack
          DESCRIPTION
              "Implementation of this optional group is
              recommended for MAUs which have one or more
              external jacks."

          GROUP rpMauNotifications
          DESCRIPTION
              "Implementation of this group is
              recommended for MAUs attached to repeater
              ports."

      ::= { mauModCompls 1 }


  mauModIfCompl MODULE-COMPLIANCE
      STATUS      current
      DESCRIPTION
          "Compliance for MAUs attached to interfaces."

      MODULE -- this module
          MANDATORY-GROUPS { mauIfGrpBasic }

          GROUP mauIfGrp100Mbs
          DESCRIPTION
              "Implementation of this optional group is
              recommended for MAUs which have 100Mb/s
              capability."



de Graaf, et. al.           Standards Track                    [Page 38]

RFC 2239          Managed Objects for IEEE 802.3 MAUs      November 1997


          GROUP mauIfGrpJack
          DESCRIPTION
              "Implementation of this optional group is
              recommended for MAUs which have one or more
              external jacks."

          GROUP mauIfGrpAutoNeg
          DESCRIPTION
              "Implementation of this group is
              mandatory for MAUs which support
              managed auto-negotiation."

          GROUP mauBroadBasic
          DESCRIPTION
              "Implementation of this group is
              mandatory for broadband MAUs."

          GROUP ifMauNotifications
          DESCRIPTION
              "Implementation of this group is
              recommended for MAUs attached to
              interfaces."

      ::= { mauModCompls 2 }

  END

4.  Acknowledgements

  This document was produced by the IETF Hub MIB Working Group, whose
  efforts were greatly advanced by the contributions of the following
  people:

       Chuck Black
       John Flick
       Jeff Johnson
       Leon Leong
       Mike Lui
       Dave Perkins
       Geoff Thompson
       Maurice Turcotte
       Paul Woodruff

  Special thanks as well to Dave Perkins for his excellent work on the
  SMICng compiler, which made it easy to take advantage of the latest
  SNMPv2 constructs in this MIB.





de Graaf, et. al.           Standards Track                    [Page 39]

RFC 2239          Managed Objects for IEEE 802.3 MAUs      November 1997


5.  References

  [1]  IEEE 802.3/ISO 8802-3 Information processing systems -
       Local area networks - Part 3:  Carrier sense multiple
       access with collision detection (CSMA/CD) access method
       and physical layer specifications, 1993.

  [2]  IEEE 802.3u-1995, "MAC Parameters, Physical Layer, Medium
       Attachment Units and Repeater for 100 Mb/s Operation,
       Type 100BASE-T," Sections 21 through 29, Supplement to
       IEEE Std 802.3, October 26, 1995.

  [3]  IEEE 802.3u-1995, "10 & 100 Mb/s Management," Section 30,
       Supplement to IEEE Std 802.3, October 26, 1995.

  [4]  de Graaf, K., D. Romascanu, D. McMaster and K.
       McCloghrie, "Definitions of Managed Objects for IEEE
       802.3 Repeater Devices using SMIv2", RFC 2108, February
       1997.

  [5]  McCloghrie, K. and M. Rose, Editors, "Management
       Information Base for Network Management of TCP/IP-based
       internets: MIB-II", STD 17, RFC 1213, March 1991.

  [6]  Case, J., McCloghrie, K., Rose, M. and S. Waldbusser,
       "Structure of Management Information for version 2 of the
       Simple Network Management Protocol (SNMPv2)", RFC 1902,
       January 1996.

  [7]  Case, J., McCloghrie, K., Rose, M. and S. Waldbusser, "Textual
       Conventions for version 2 of the Simple Network Management
       Protocol (SNMPv2)", RFC 1903, January 1996.

  [8]  Case, J., McCloghrie, K., Rose, M. and S. Waldbusser,
       "Conformance Statements for version 2 of the Simple Network
       Management Protocol (SNMPv2)", RFC 1904, January 1996.

  [9]  Case, J., McCloghrie, K., Rose, M. and S. Waldbusser, "Protocol
       Operations for version 2 of the Simple Network Management
       Protocol (SNMPv2)", RFC 1905, January 1996.

  [10] Case, J., M. Fedor, M. Schoffstall and  J. Davin, "Simple
       Network Management Protocol", STD 15, RFC 1157, May 1990.

  [11] McMaster, D., K. McCloghrie and  S. Roberts, "Definitions of
       Managed Objects for IEEE 802.3 Medium Attachment Units
       (MAUs)", RFC 1515, September 1993.




de Graaf, et. al.           Standards Track                    [Page 40]

RFC 2239          Managed Objects for IEEE 802.3 MAUs      November 1997


6.  Security Considerations

  Certain management information defined in this MIB may be considered
  sensitive in some network environments.  Therefore, authentication of
  received SNMP requests and controlled access to management
  information should be employed in such environments.  The method for
  this authentication is a function of the SNMP Administrative
  Framework, and has not been expanded by this MIB.

  Several objects in this MIB allow write access.  Setting these
  objects can have a serious effect on the operation of the network,
  including enabling or disabling a MAU, changing a MAU's default type,
  enabling, disabling or restarting autonegotiation, or modifying the
  capabilities that a MAU advertizes during autonegotiation.  It is
  recommended that implementers seriously consider whether set
  operations should be allowed without providing, at a minimum,
  authentication of request origin.

7.  Authors' Addresses

  Kathryn de Graaf
  3Com Corporation
  118 Turnpike Rd.
  Southborough, MA 01772 USA

  Phone: (508)229-1627
  Fax:   (508)490-5882
  EMail: [email protected]


  Dan Romascanu
  Madge Networks (Israel) Ltd.
  Atidim Technology Park, Bldg. 3
  Tel Aviv 61131, Israel

  Phone: 972-3-6458414, 6458458
  Fax:   972-3-6487146
  EMail: [email protected]


  Donna McMaster
  Cisco Systems Inc.
  170 West Tasman Drive
  San Jose, CA 95134

  Phone:: (408) 526-5260
  EMail: [email protected]




de Graaf, et. al.           Standards Track                    [Page 41]

RFC 2239          Managed Objects for IEEE 802.3 MAUs      November 1997


  Keith McCloghrie
  Cisco Systems Inc.
  170 West Tasman Drive
  San Jose, CA 95134

  Phone: (408) 526-5260
  EMail: [email protected]


  Sam Roberts
  Farallon Computing, Inc.
  2470 Mariner Square Loop
  Alameda, CA 94501-1010

  Phone:: (510) 814-5215
  EMail: [email protected]



































de Graaf, et. al.           Standards Track                    [Page 42]

RFC 2239          Managed Objects for IEEE 802.3 MAUs      November 1997


8.  Full Copyright Statement

  Copyright (C) The Internet Society (1997).  All Rights Reserved.

  This document and translations of it may be copied and furnished to
  others, and derivative works that comment on or otherwise explain it
  or assist in its implementation may be prepared, copied, published
  and distributed, in whole or in part, without restriction of any
  kind, provided that the above copyright notice and this paragraph are
  included on all such copies and derivative works.  However, this
  document itself may not be modified in any way, such as by removing
  the copyright notice or references to the Internet Society or other
  Internet organizations, except as needed for the purpose of
  developing Internet standards in which case the procedures for
  copyrights defined in the Internet Standards process must be
  followed, or as required to translate it into languages other than
  English.

  The limited permissions granted above are perpetual and will not be
  revoked by the Internet Society or its successors or assigns.

  This document and the information contained herein is provided on an
  "AS IS" basis and THE INTERNET SOCIETY AND THE INTERNET ENGINEERING
  TASK FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
  BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION
  HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF
  MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
























de Graaf, et. al.           Standards Track                    [Page 43]