Network Working Group                                            J. Case
Request for Comments: 1512                The University of Tennesse and
Updates: 1285                                SNMP Research, Incorporated
                                                         A. Rijsinghani
                                          Digital Equipment Corporation
                                                         September 1993

                   FDDI Management Information Base

Status of this Memo

  This RFC specifies an Internet standards track protocol for the
  Internet community, and requests discussion and suggestions for
  improvements.  Please refer to the current edition of the "Internet
  Official Protocol Standards" for the standardization state and status
  of this protocol.  Distribution of this memo is unlimited.

Abstract

  This memo defines a portion of the Management Information Base (MIB)
  for use with network management protocols in TCP/IP-based internets.
  In particular, it defines objects for managing devices which
  implement the FDDI based on the ANSI FDDI SMT 7.3 draft standard [8],
  which has been forwarded for publication by the X3T9.5 committee.

Table of Contents

  1. The Network Management Framework ......................    2
  1.1 Object Definitions ...................................    2
  1.2 Format of Definitions ................................    2
  2. Overview ..............................................    2
  2.1 Textual Conventions ..................................    3
  3. Changes from RFC 1285 .................................    3
  4. Object Definitions ....................................    4
  4.1 The SMT Group ........................................    6
  4.2 The MAC Group ........................................   17
  4.3 The Enhanced MAC Counters Group ......................   29
  4.4 The PATH Group .......................................   32
  4.5 The PORT Group .......................................   38
  5. Acknowledgements ......................................   48
  6. References ............................................   50
  7. Security Considerations ...............................   51
  8. Authors' Addresses ....................................   51








Case & Rijsinghani                                              [Page 1]

RFC 1512                        FDDI MIB                  September 1993


1.  The Network Management Framework

  The Internet-standard Network Management Framework consists of three
  components.  They are:

     o STD 16, RFC 1155 which defines the SMI, the mechanisms used for
       describing and naming objects for the purpose of
       management.  STD 16, RFC 1212 defines a more concise description
       mechanism, which is wholly consistent with the SMI.

     o STD 17, RFC 1213 defines MIB-II, the core set of managed objects
       for the Internet suite of protocols.

     o STD 15, RFC 1157 which defines the SNMP, the protocol used for
       network access to managed objects.

  The Framework permits new objects to be defined for the purpose of
  experimentation and evaluation.

1.1.  Object Definitions

  Managed objects are accessed via a virtual information store, termed
  the Management Information Base or MIB.  Objects in the MIB are
  defined using the subset of Abstract Syntax Notation One (ASN.1)
  defined in the SMI.  In particular, each object object type is named
  by an OBJECT IDENTIFIER, an administratively assigned name.  The
  object type together with an object instance serves to uniquely
  identify a specific instantiation of the object.  For human
  convenience, we often use a textual string, termed the descriptor, to
  refer to the object type.

1.2.  Format of Definitions

  Section 4 contains contains the specification of all object types
  contained in this MIB module.  The object types are defined using the
  conventions defined in the SMI, as amended by the extensions
  specified in [7].

2.  Overview

  This document defines the managed objects for FDDI devices which are
  to be accessible via the Simple Network Management Protocol (SNMP).
  At present, this applies to these values of the ifType variable in
  the Internet-standard MIB:

              fddi(15)

  For these interfaces, the value of the ifSpecific variable in the



Case & Rijsinghani                                              [Page 2]

RFC 1512                        FDDI MIB                  September 1993


  MIB-II [4] has the OBJECT IDENTIFIER value:

              fddimib    OBJECT IDENTIFIER ::= { fddi 73 }

  The definitions of the objects presented here draws heavily from
  related work in the ANSI X3T9.5 committee and the SMT subcommittee of
  that committee [8].  In fact, the definitions of the managed objects
  in this document are, to the maximum extent possible, identical to
  those identified by the ANSI committee.  The semantics of each
  managed object should be the same with syntactic changes made as
  necessary to recast the objects in terms of the Internet-standard SMI
  and MIB so as to be compatible with the SNMP.  Examples of these
  syntactic changes include remapping booleans to enumerated integers,
  remapping bit strings to octet strings, and the like.  In addition,
  the naming of the objects was changed to achieve compatibility.

  These minimal syntactic changes with no semantic changes should allow
  implementations of SNMP manageable FDDI systems to share
  instrumentation with other network management schemes and thereby
  minimize implementation cost.  In addition, the translation of
  information conveyed by managed objects from one network management
  scheme to another is eased by these shared definitions.

  Only the essential variables, as indicated by their mandatory status
  in the ANSI specification, were retained in this document.  The
  importance of variables which have an optional status in the ANSI
  specification were perceived as being less widely accepted.

2.1.  Textual Conventions

  Several new datatypes are introduced as a textual convention in this
  MIB document.  These textual conventions enhance the readability of
  the document and ease comparisons with its ANSI counterpart.  It
  should be noted that the introduction of these textual conventions
  has no effect on either the syntax or the semantics of any managed
  objects.  The use of these is merely an artifact of the explanatory
  method used.  Objects defined in terms of one of these methods are
  always encoded by means of the rules that define the primitive type.
  Hence, no changes to the SMI or the SNMP are necessary to accommodate
  these textual conventions which are adopted merely for the
  convenience of readers and writers in pursuit of the elusive goal of
  clear, concise, and unambiguous MIB documents.

3.  Changes from RFC 1285

  The changes from RFC 1285 [2] to this document, based on changes from
  ANSI SMT 6.2 to SMT 7.3, were so numerous that the objects in this
  MIB module are located on a different branch of the MIB tree.  No



Case & Rijsinghani                                              [Page 3]

RFC 1512                        FDDI MIB                  September 1993


  assumptions should be made about compatibility with RFC 1285.

4.  Object Definitions

         FDDI-SMT73-MIB DEFINITIONS ::= BEGIN

         IMPORTS
                 Counter
                     FROM RFC1155-SMI
                 OBJECT-TYPE
                     FROM RFC-1212;

         --  This MIB module uses the extended OBJECT-TYPE macro as
         --  defined in [7].


         -- this is the FDDI MIB module

         fddi    OBJECT IDENTIFIER ::= { transmission 15 }
         fddimib   OBJECT IDENTIFIER ::= { fddi 73 }


         -- textual conventions

         FddiTimeNano ::= INTEGER (0..2147483647)
         -- This data type specifies 1 nanosecond units as
         -- an integer value.
         --
         -- NOTE: The encoding is normal integer representation, not
         -- two's complement.  Since this type is used for variables
         -- which are encoded as TimerTwosComplement in the ANSI
         -- specification, two operations need to be performed on such
         -- variables to convert from ANSI form to SNMP form:
         --
         -- 1) Convert from two's complement to normal integer
         --    representation
         -- 2) Multiply by 80 to convert from 80 nsec to 1 nsec units
         --
         -- No resolution is lost.  Moreover, the objects for which
         -- this data type is used effectively do not lose any range
         -- due to the lower maximum value since they do not require
         -- the full range.
         --
         -- Example: If fddimibMACTReq had a value of 8 ms, it would
         -- be stored in ANSI TimerTwosComplement format as 0xFFFE7960
         -- [8 ms is 100000 in 80 nsec units, which is then converted
         -- to two's complement] but be reported as 8000000 in SNMP
         -- since it is encoded here as FddiTimeNano.



Case & Rijsinghani                                              [Page 4]

RFC 1512                        FDDI MIB                  September 1993


         FddiTimeMilli ::= INTEGER (0..2147483647)
         -- This data type is used for some FDDI timers. It specifies
         -- time in 1 millisecond units, in normal integer
         -- representation.

         FddiResourceId ::= INTEGER (0..65535)
         -- This data type is used to refer to an instance of a  MAC,
         -- PORT, or PATH Resource ID.  Indexing begins
         -- at 1.  Zero is used to indicate the absence of a resource.

         FddiSMTStationIdType ::= OCTET STRING (SIZE (8))
         -- The unique identifier for the FDDI station.  This is a
         -- string of 8 octets, represented as X' yy yy xx xx xx xx
         -- xx xx' with the low order 6 octet (xx) from a unique IEEE
         -- assigned address.  The high order two bits of the IEEE
         -- address, the group address bit and the administration bit
         -- (Universal/Local) bit should both be zero.  The first two
         -- octets, the yy octets, are implementor-defined.
         --
         -- The representation of the address portion of the station id
         -- is in the IEEE (ANSI/IEEE P802.1A) canonical notation for
         -- 48 bit addresses.  The canonical form is a 6-octet string
         -- where the first octet contains the first 8 bits of the
         -- address, with the I/G(Individual/Group) address bit as the
         -- least significant bit and the  U/L (Universal/Local) bit
         -- as the next more significant bit, and so on.  Note that
         -- addresses in the ANSI FDDI standard SMT frames are
         -- represented in FDDI MAC order.

         FddiMACLongAddressType ::= OCTET STRING (SIZE (6))
         -- The representation of long MAC addresses as management
         -- values is in the IEEE (ANSI/IEEE P802.1A) canonical
         -- notation for 48 bit addresses.  The canonical form is a
         -- 6-octet string where the first octet contains the first 8
         -- bits of the address, with the I/G (Individual/Group)
         -- address bit as the least significant bit and the  U/L
         -- (Universal/Local) bit as the next more significant bit,
         -- and so on.  Note that the addresses in the SMT frames are
         -- represented in FDDI MAC order.


         -- groups in the FDDI MIB module

         fddimibSMT          OBJECT IDENTIFIER ::= { fddimib 1 }

         fddimibMAC          OBJECT IDENTIFIER ::= { fddimib 2 }

         fddimibMACCounters  OBJECT IDENTIFIER ::= { fddimib 3 }



Case & Rijsinghani                                              [Page 5]

RFC 1512                        FDDI MIB                  September 1993


         fddimibPATH         OBJECT IDENTIFIER ::= { fddimib 4 }

         fddimibPORT         OBJECT IDENTIFIER ::= { fddimib 5 }


         -- the SMT group
         -- Implementation of the SMT group is mandatory for all
         -- systems which implement manageable FDDI subsystems.

         fddimibSMTNumber OBJECT-TYPE
             SYNTAX  INTEGER (0..65535)
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "The number of SMT implementations (regardless of
                     their current state) on this network management
                     application entity.  The value for this variable
                     must remain constant at least from one re-
                     initialization of the entity's network management
                     system to the next re-initialization."
             ::= { fddimibSMT  1 }


         -- the SMT table

         fddimibSMTTable OBJECT-TYPE
             SYNTAX  SEQUENCE OF FddimibSMTEntry
             ACCESS  not-accessible
             STATUS  mandatory
             DESCRIPTION
                     "A list of SMT entries.  The number of entries
                     shall not exceed the value of fddimibSMTNumber."
             ::= { fddimibSMT  2 }

         fddimibSMTEntry OBJECT-TYPE
             SYNTAX  FddimibSMTEntry
             ACCESS  not-accessible
             STATUS  mandatory
             DESCRIPTION
                     "An SMT entry containing information common to a
                     given SMT."
             INDEX   { fddimibSMTIndex }
             ::= { fddimibSMTTable 1 }

         FddimibSMTEntry ::=
             SEQUENCE {
                 fddimibSMTIndex
                     INTEGER,



Case & Rijsinghani                                              [Page 6]

RFC 1512                        FDDI MIB                  September 1993


                 fddimibSMTStationId
                     FddiSMTStationIdType,
                 fddimibSMTOpVersionId
                     INTEGER,
                 fddimibSMTHiVersionId
                     INTEGER,
                 fddimibSMTLoVersionId
                     INTEGER,
                 fddimibSMTUserData
                     OCTET STRING,
                 fddimibSMTMIBVersionId
                     INTEGER,
                 fddimibSMTMACCts
                     INTEGER,
                 fddimibSMTNonMasterCts
                     INTEGER,
                 fddimibSMTMasterCts
                     INTEGER,
                 fddimibSMTAvailablePaths
                     INTEGER,
                 fddimibSMTConfigCapabilities
                     INTEGER,
                 fddimibSMTConfigPolicy
                     INTEGER,
                 fddimibSMTConnectionPolicy
                     INTEGER,
                 fddimibSMTTNotify
                     INTEGER,
                 fddimibSMTStatRptPolicy
                     INTEGER,
                 fddimibSMTTraceMaxExpiration
                     FddiTimeMilli,
                 fddimibSMTBypassPresent
                     INTEGER,
                 fddimibSMTECMState
                     INTEGER,
                 fddimibSMTCFState
                     INTEGER,
                 fddimibSMTRemoteDisconnectFlag
                     INTEGER,
                 fddimibSMTStationStatus
                     INTEGER,
                 fddimibSMTPeerWrapFlag
                     INTEGER,
                 fddimibSMTTimeStamp
                     FddiTimeMilli,
                 fddimibSMTTransitionTimeStamp
                     FddiTimeMilli,



Case & Rijsinghani                                              [Page 7]

RFC 1512                        FDDI MIB                  September 1993


                 fddimibSMTStationAction
                     INTEGER
             }

         fddimibSMTIndex OBJECT-TYPE
             SYNTAX  INTEGER (1..65535)
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "A unique value for each SMT.  The value for each
                     SMT must remain constant at least from one re-
                     initialization of the entity's network management
                     system to the next re-initialization."
             ::= { fddimibSMTEntry 1 }

         fddimibSMTStationId OBJECT-TYPE
             SYNTAX  FddiSMTStationIdType -- OCTET STRING (SIZE (8))
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "Used to uniquely identify an FDDI station."
             REFERENCE
                     "ANSI { fddiSMT 11 }"
             ::= { fddimibSMTEntry 2 }

         fddimibSMTOpVersionId OBJECT-TYPE
             SYNTAX  INTEGER (1..65535)
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "The version that this station is using for its
                     operation (refer to ANSI 7.1.2.2). The value of
                     this variable is 2 for this SMT revision."
             REFERENCE
                     "ANSI { fddiSMT 13 }"
             ::= { fddimibSMTEntry 3 }

         fddimibSMTHiVersionId OBJECT-TYPE
             SYNTAX  INTEGER (1..65535)
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "The highest version of SMT that this station
                     supports (refer to ANSI 7.1.2.2)."
             REFERENCE
                     "ANSI { fddiSMT 14 }"
             ::= { fddimibSMTEntry 4 }




Case & Rijsinghani                                              [Page 8]

RFC 1512                        FDDI MIB                  September 1993


         fddimibSMTLoVersionId OBJECT-TYPE
             SYNTAX  INTEGER (1..65535)
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "The lowest version of SMT that this station
                     supports (refer to ANSI 7.1.2.2)."
             REFERENCE
                     "ANSI { fddiSMT 15 }"
             ::= { fddimibSMTEntry 5 }

         fddimibSMTUserData OBJECT-TYPE
             SYNTAX  OCTET STRING (SIZE (32))
             ACCESS  read-write
             STATUS  mandatory
             DESCRIPTION
                     "This variable contains 32 octets of user defined
                     information. The information shall be an ASCII
                     string."
             REFERENCE
                     "ANSI { fddiSMT 17 }"
             ::= { fddimibSMTEntry 6 }

         fddimibSMTMIBVersionId OBJECT-TYPE
             SYNTAX  INTEGER (0..65535)
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "The version of the FDDI MIB of this station.  The
                     value of this variable is 1 for this SMT
                     revision."
             REFERENCE
                     "ANSI { fddiSMT 18 }"
             ::= { fddimibSMTEntry 7 }

         fddimibSMTMACCts OBJECT-TYPE
             SYNTAX  INTEGER (0..255)
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "The number of MACs in this station or
                     concentrator."
             REFERENCE
                     "ANSI { fddiSMT 21 }"
             ::= { fddimibSMTEntry 8 }

         fddimibSMTNonMasterCts OBJECT-TYPE
             SYNTAX  INTEGER (0..2)



Case & Rijsinghani                                              [Page 9]

RFC 1512                        FDDI MIB                  September 1993


             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "The value of this variable is the number of A, B,
                     and S ports in this station or concentrator."
             REFERENCE
                     "ANSI { fddiSMT 22 }"
             ::= { fddimibSMTEntry 9 }

         fddimibSMTMasterCts OBJECT-TYPE
             SYNTAX  INTEGER (0..255)
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "The number of M Ports in a node. If the node is
                     not a concentrator, the value of the variable is
                     zero."
             REFERENCE
                     "ANSI { fddiSMT 23 }"
             ::= { fddimibSMTEntry 10 }

         fddimibSMTAvailablePaths OBJECT-TYPE
             SYNTAX  INTEGER (0..7)
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "A value that indicates the PATH types available
                     in the station.

                     The value is a sum.  This value initially takes
                     the value zero, then for each type of PATH that
                     this node has available, 2 raised to a power is
                     added to the sum.  The powers are according to the
                     following table:

                              Path   Power
                           Primary     0
                         Secondary     1
                             Local     2

                     For example, a station having Primary and Local
                     PATHs available would have a value of 5 (2**0 +
                     2**2)."
             REFERENCE
                     "ANSI { fddiSMT 24 }"
             ::= { fddimibSMTEntry 11 }

         fddimibSMTConfigCapabilities OBJECT-TYPE



Case & Rijsinghani                                             [Page 10]

RFC 1512                        FDDI MIB                  September 1993


             SYNTAX  INTEGER (0..3)
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "A value that indicates the configuration
                     capabilities of a node. The 'Hold Available' bit
                     indicates the support of the optional Hold
                     Function, which is controlled by
                     fddiSMTConfigPolicy.  The 'CF-Wrap-AB' bit
                     indicates that the station has the capability of
                     performing a wrap_ab (refer to ANSI SMT 9.7.2.2).

                     The value is a sum.  This value initially takes
                     the value zero, then for each of the configuration
                     policies currently enforced on the node, 2 raised
                     to a power is added to the sum.  The powers are
                     according to the following table:

                                Policy   Power
                         holdAvailable     0
                            CF-Wrap-AB     1 "
             REFERENCE
                     "ANSI { fddiSMT 25 }"
             ::= { fddimibSMTEntry 12 }

         fddimibSMTConfigPolicy OBJECT-TYPE
             SYNTAX  INTEGER (0..1)
             ACCESS  read-write
             STATUS  mandatory
             DESCRIPTION
                     "A value that indicates the configuration policies
                     currently desired in a node.  'Hold' is one of the
                     terms used for the Hold Flag, an optional ECM flag
                     used to enable the optional Hold policy.

                     The value is a sum.  This value initially takes
                     the value zero, then for each of the configuration
                     policies currently enforced on the node, 2 raised
                     to a power is added to the sum.  The powers are
                     according to the following table:

                                    Policy   Power
                         configurationhold     0 "
             REFERENCE
                     "ANSI { fddiSMT 26 }"
             ::= { fddimibSMTEntry 13 }

         fddimibSMTConnectionPolicy OBJECT-TYPE



Case & Rijsinghani                                             [Page 11]

RFC 1512                        FDDI MIB                  September 1993


             SYNTAX  INTEGER (32768..65535)
             ACCESS  read-write
             STATUS  mandatory
             DESCRIPTION
                     "A value representing the connection policies in
                     effect in a node. A station sets the corresponding
                     bit for each of the connection types that it
                     rejects. The letter designations, X and Y, in the
                     'rejectX-Y' names have the following significance:
                     X represents the PC-Type of the local PORT and Y
                     represents the PC_Type of the adjacent PORT
                     (PC_Neighbor). The evaluation of Connection-
                     Policy (PC-Type, PC-Neighbor) is done to determine
                     the setting of T- Val(3) in the PC-Signalling
                     sequence (refer to ANSI 9.6.3). Note that Bit 15,
                     (rejectM-M), is always set and cannot be cleared.

                     The value is a sum.  This value initially takes
                     the value zero, then for each of the connection
                     policies currently enforced on the node, 2 raised
                     to a power is added to the sum.  The powers are
                     according to the following table:

                            Policy   Power
                         rejectA-A     0
                         rejectA-B     1
                         rejectA-S     2
                         rejectA-M     3
                         rejectB-A     4
                         rejectB-B     5
                         rejectB-S     6
                         rejectB-M     7
                         rejectS-A     8
                         rejectS-B     9
                         rejectS-S     10
                         rejectS-M     11
                         rejectM-A     12
                         rejectM-B     13
                         rejectM-S     14
                         rejectM-M     15 "
             REFERENCE
                     "ANSI { fddiSMT 27 }"
             ::= { fddimibSMTEntry 14 }

         fddimibSMTTNotify OBJECT-TYPE
             SYNTAX  INTEGER (2..30)
             ACCESS  read-write
             STATUS  mandatory



Case & Rijsinghani                                             [Page 12]

RFC 1512                        FDDI MIB                  September 1993


             DESCRIPTION
                     "The timer, expressed in seconds, used in the
                     Neighbor Notification protocol. It has a range of
                     2 seconds to 30 seconds, and its default value is
                     30 seconds (refer to ANSI SMT 8.2)."
             REFERENCE
                     "ANSI { fddiSMT 29 }"
             ::= { fddimibSMTEntry 15 }

         fddimibSMTStatRptPolicy OBJECT-TYPE
             SYNTAX  INTEGER { true(1), false(2) }
             ACCESS  read-write
             STATUS  mandatory
             DESCRIPTION
                     "If true, indicates that the node will generate
                     Status Reporting Frames for its implemented events
                     and conditions. It has an initial value of true.
                     This variable determines the value of the
                     SR_Enable Flag (refer to ANSI SMT 8.3.2.1)."
             REFERENCE
                     "ANSI { fddiSMT 30 }"
             ::= { fddimibSMTEntry 16 }

         fddimibSMTTraceMaxExpiration OBJECT-TYPE
             SYNTAX  FddiTimeMilli
             ACCESS  read-write
             STATUS  mandatory
             DESCRIPTION
                     "Reference Trace_Max (refer to ANSI SMT
                     9.4.4.2.2)."
             REFERENCE
                     "ANSI { fddiSMT 31 }"
             ::= { fddimibSMTEntry 17 }

         fddimibSMTBypassPresent OBJECT-TYPE
             SYNTAX  INTEGER { true(1), false(2) }
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "A flag indicating if the station has a bypass on
                     its AB port pair."
             REFERENCE
                     "ANSI { fddiSMT 34 }"
             ::= { fddimibSMTEntry 18 }

         fddimibSMTECMState OBJECT-TYPE
             SYNTAX  INTEGER {
                         ec0(1), -- Out



Case & Rijsinghani                                             [Page 13]

RFC 1512                        FDDI MIB                  September 1993


                         ec1(2), -- In
                         ec2(3), -- Trace
                         ec3(4), -- Leave
                         ec4(5), -- Path_Test
                         ec5(6), -- Insert
                         ec6(7), -- Check
                         ec7(8)  -- Deinsert
                     }
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "Indicates the current state of the ECM state
                     machine (refer to ANSI SMT 9.5.2)."
             REFERENCE
                     "ANSI { fddiSMT 41 }"
             ::= { fddimibSMTEntry 19 }

         fddimibSMTCFState OBJECT-TYPE
             SYNTAX  INTEGER {
                         cf0(1),   -- isolated
                         cf1(2),   -- local_a
                         cf2(3),   -- local_b
                         cf3(4),   -- local_ab
                         cf4(5),   -- local_s
                         cf5(6),   -- wrap_a
                         cf6(7),   -- wrap_b
                         cf7(8),   -- wrap_ab
                         cf8(9),   -- wrap_s
                         cf9(10),  -- c_wrap_a
                         cf10(11), -- c_wrap_b
                         cf11(12), -- c_wrap_s
                         cf12(13)  -- thru
                     }
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "The attachment configuration for the station or
                     concentrator (refer to ANSI SMT 9.7.2.2)."
             REFERENCE
                     "ANSI { fddiSMT 42 }"
             ::= { fddimibSMTEntry 20 }

         fddimibSMTRemoteDisconnectFlag OBJECT-TYPE
             SYNTAX  INTEGER { true(1), false(2) }
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "A flag indicating that the station was remotely



Case & Rijsinghani                                             [Page 14]

RFC 1512                        FDDI MIB                  September 1993


                     disconnected from the network as a result of
                     receiving an fddiSMTAction, disconnect (refer to
                     ANSI SMT 6.4.5.3) in a Parameter Management Frame.
                     A station requires a Connect Action to rejoin and
                     clear the flag (refer to ANSI SMT 6.4.5.2)."
             REFERENCE
                     "ANSI { fddiSMT 44 }"
             ::= { fddimibSMTEntry 21 }

         fddimibSMTStationStatus OBJECT-TYPE
             SYNTAX  INTEGER { concatenated(1), separated(2), thru(3) }
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "The current status of the primary and secondary
                     paths within this station."
             REFERENCE
                     "ANSI { fddiSMT 45 }"
             ::= { fddimibSMTEntry 22 }

         fddimibSMTPeerWrapFlag OBJECT-TYPE
             SYNTAX  INTEGER { true(1), false(2) }
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "This variable assumes the value of the
                     PeerWrapFlag in CFM (refer to ANSI SMT
                     9.7.2.4.4)."
             REFERENCE
                     "ANSI { fddiSMT 46 }"
             ::= { fddimibSMTEntry 23 }

         fddimibSMTTimeStamp OBJECT-TYPE
             SYNTAX  FddiTimeMilli
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "This variable assumes the value of TimeStamp
                     (refer to ANSI SMT 8.3.2.1)."
             REFERENCE
                     "ANSI { fddiSMT 51 }"
             ::= { fddimibSMTEntry 24 }

         fddimibSMTTransitionTimeStamp OBJECT-TYPE
             SYNTAX  FddiTimeMilli
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION



Case & Rijsinghani                                             [Page 15]

RFC 1512                        FDDI MIB                  September 1993


                     "This variable assumes the value of
                     TransitionTimeStamp (refer to ANSI SMT 8.3.2.1)."
             REFERENCE
                     "ANSI { fddiSMT 52 }"
             ::= { fddimibSMTEntry 25 }

         fddimibSMTStationAction OBJECT-TYPE
             SYNTAX  INTEGER {
                         other(1),               -- none of the following
                         connect(2),
                         disconnect(3),
                         path-Test(4),
                         self-Test(5),
                         disable-a(6),
                         disable-b(7),
                         disable-m(8)
                     }
             ACCESS  read-write
             STATUS  mandatory
             DESCRIPTION
                     "This object, when read, always returns a value of
                     other(1).  The behavior of setting this variable
                     to each of the acceptable values is as follows:

                          other(1): Results in an appropriate error.
                          connect(2): Generates a Connect signal to ECM
                               to begin a connection sequence. See ANSI
                               Ref 9.4.2.
                          disconnect(3): Generates a Disconnect signal
                               to ECM. see ANSI Ref 9.4.2.
                          path-Test(4): Initiates a station Path_Test.
                               The Path_Test variable (see ANSI Ref
                               9.4.1) is set to 'Testing'. The results
                               of this action are not specified in this
                               standard.
                          self-Test(5): Initiates a station Self_Test.
                               The results of this action are not
                               specified in this standard.
                          disable-a(6): Causes a PC_Disable on the A
                               port if the A port mode is peer.
                          disable-b(7): Causes a PC_Disable on the B
                               port if the B port mode is peer.
                          disable-m(8): Causes a PC_Disable on all M
                               ports.

                     Attempts to set this object to all other values
                     results in an appropriate error.  The result of
                     setting this variable to path-Test(4) or self-



Case & Rijsinghani                                             [Page 16]

RFC 1512                        FDDI MIB                  September 1993


                     Test(5) is implementation-specific."
             REFERENCE
                     "ANSI { fddiSMT 60 }"
             ::= { fddimibSMTEntry 26 }


         -- the MAC group
         -- Implementation of the MAC Group is mandatory for all
         -- systems which implement manageable FDDI subsystems.

         fddimibMACNumber OBJECT-TYPE
             SYNTAX  INTEGER (0..65535)
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "The total number of MAC implementations (across
                     all SMTs) on this network management application
                     entity.  The value for this variable must remain
                     constant at least from one re-initialization of
                     the entity's network management system to the next
                     re-initialization."
             ::= { fddimibMAC  1 }


         -- the MAC table

         fddimibMACTable OBJECT-TYPE
             SYNTAX  SEQUENCE OF FddimibMACEntry
             ACCESS  not-accessible
             STATUS  mandatory
             DESCRIPTION
                     "A list of MAC entries.  The number of entries
                     shall not exceed the value of fddimibMACNumber."
             ::= { fddimibMAC  2 }

         fddimibMACEntry OBJECT-TYPE
             SYNTAX  FddimibMACEntry
             ACCESS  not-accessible
             STATUS  mandatory
             DESCRIPTION
                     "A MAC entry containing information common to a
                     given MAC."
             INDEX   { fddimibMACSMTIndex, fddimibMACIndex }
             ::= { fddimibMACTable 1 }

         FddimibMACEntry ::=
             SEQUENCE {
                 fddimibMACSMTIndex



Case & Rijsinghani                                             [Page 17]

RFC 1512                        FDDI MIB                  September 1993


                         INTEGER,
                 fddimibMACIndex
                         INTEGER,
                 fddimibMACIfIndex
                         INTEGER,
                 fddimibMACFrameStatusFunctions
                         INTEGER,
                 fddimibMACTMaxCapability
                         FddiTimeNano,
                 fddimibMACTVXCapability
                         FddiTimeNano,
                 fddimibMACAvailablePaths
                         INTEGER,
                 fddimibMACCurrentPath
                         INTEGER,
                 fddimibMACUpstreamNbr
                         FddiMACLongAddressType,
                 fddimibMACDownstreamNbr
                         FddiMACLongAddressType,
                 fddimibMACOldUpstreamNbr
                         FddiMACLongAddressType,
                 fddimibMACOldDownstreamNbr
                         FddiMACLongAddressType,
                 fddimibMACDupAddressTest
                         INTEGER,
                 fddimibMACRequestedPaths
                         INTEGER,
                 fddimibMACDownstreamPORTType
                         INTEGER,
                 fddimibMACSMTAddress
                         FddiMACLongAddressType,
                 fddimibMACTReq
                         FddiTimeNano,
                 fddimibMACTNeg
                         FddiTimeNano,
                 fddimibMACTMax
                         FddiTimeNano,
                 fddimibMACTvxValue
                         FddiTimeNano,
                 fddimibMACFrameCts
                         Counter,
                 fddimibMACCopiedCts
                         Counter,
                 fddimibMACTransmitCts
                         Counter,
                 fddimibMACErrorCts
                         Counter,
                 fddimibMACLostCts



Case & Rijsinghani                                             [Page 18]

RFC 1512                        FDDI MIB                  September 1993


                         Counter,
                 fddimibMACFrameErrorThreshold
                         INTEGER,
                 fddimibMACFrameErrorRatio
                         INTEGER,
                 fddimibMACRMTState
                         INTEGER,
                 fddimibMACDaFlag
                         INTEGER,
                 fddimibMACUnaDaFlag
                         INTEGER,
                 fddimibMACFrameErrorFlag
                         INTEGER,
                 fddimibMACMAUnitdataAvailable
                         INTEGER,
                 fddimibMACHardwarePresent
                         INTEGER,
                 fddimibMACMAUnitdataEnable
                         INTEGER
             }


         fddimibMACSMTIndex OBJECT-TYPE
             SYNTAX  INTEGER (1..65535)
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "The value of the SMT index associated with this
                     MAC."
             ::= { fddimibMACEntry 1 }

         fddimibMACIndex OBJECT-TYPE
             SYNTAX  INTEGER (1..65535)
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "Index variable for uniquely identifying the MAC
                     object instances, which is the same as the
                     corresponding resource index in SMT."
             REFERENCE
                     "ANSI { fddiMAC 34 }"
             ::= { fddimibMACEntry 2 }

         fddimibMACIfIndex OBJECT-TYPE
             SYNTAX  INTEGER (1..65535)
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION



Case & Rijsinghani                                             [Page 19]

RFC 1512                        FDDI MIB                  September 1993


                     "The value of the MIB-II ifIndex corresponding to
                     this MAC.  If none is applicable, 0 is returned."
             REFERENCE
                     "MIB-II"
             ::= { fddimibMACEntry 3 }

         fddimibMACFrameStatusFunctions OBJECT-TYPE
             SYNTAX  INTEGER (0..7)
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "Indicates the MAC's optional Frame Status
                     processing functions.

                     The value is a sum.  This value initially takes
                     the value zero, then for each function present, 2
                     raised to a power is added to the sum.  The powers
                     are according to the following table:

                          function   Power
                      fs-repeating     0
                        fs-setting     1
                       fs-clearing     2 "
             REFERENCE
                     "ANSI { fddiMAC 11 }"
             ::= { fddimibMACEntry 4 }

         fddimibMACTMaxCapability OBJECT-TYPE
             SYNTAX  FddiTimeNano
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "Indicates the maximum time value of fddiMACTMax
                     that this MAC can support."
             REFERENCE
                     "ANSI { fddiMAC 13 }"
             ::= { fddimibMACEntry 5 }

         fddimibMACTVXCapability OBJECT-TYPE
             SYNTAX  FddiTimeNano
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "Indicates the maximum time value of
                     fddiMACTvxValue that this MAC can support."
             REFERENCE
                     "ANSI { fddiMAC 14 }"
             ::= { fddimibMACEntry 6 }



Case & Rijsinghani                                             [Page 20]

RFC 1512                        FDDI MIB                  September 1993


         fddimibMACAvailablePaths OBJECT-TYPE
             SYNTAX  INTEGER (0..7)
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "Indicates the paths available for this MAC (refer
                     to ANSI SMT 9.7.7).

                     The value is a sum.  This value initially takes
                     the value zero, then for each type of PATH that
                     this MAC has available, 2 raised to a power is
                     added to the sum.  The powers are according to the
                     following table:

                              Path   Power
                           Primary     0
                         Secondary     1
                             Local     2 "
             REFERENCE
                     "ANSI { fddiMAC 22 }"
             ::= { fddimibMACEntry 7 }

         fddimibMACCurrentPath OBJECT-TYPE
             SYNTAX  INTEGER {
                         isolated(1),
                         local(2),
                         secondary(3),
                         primary(4),
                         concatenated(5),
                         thru(6)
                     }
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "Indicates the Path into which this MAC is
                     currently inserted (refer to ANSI 9.7.7)."
             REFERENCE
                     "ANSI { fddiMAC 23 }"
             ::= { fddimibMACEntry 8 }

         fddimibMACUpstreamNbr OBJECT-TYPE
             SYNTAX  FddiMACLongAddressType -- OCTET STRING (SIZE (6))
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "The MAC's upstream neighbor's long individual MAC
                     address. It has an initial value of the SMT-
                     Unknown-MAC Address and is only modified as



Case & Rijsinghani                                             [Page 21]

RFC 1512                        FDDI MIB                  September 1993


                     specified by the Neighbor Information Frame
                     protocol (refer to ANSI SMT 7.2.1 and 8.2)."
             REFERENCE
                     "ANSI { fddiMAC 24 }"
             ::= { fddimibMACEntry 9 }

         fddimibMACDownstreamNbr OBJECT-TYPE
             SYNTAX  FddiMACLongAddressType -- OCTET STRING (SIZE (6))
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "The MAC's downstream neighbor's long individual
                     MAC address. It has an initial value of the SMT-
                     Unknown-MAC Address and is only modified as
                     specified by the Neighbor Information Frame
                     protocol (refer to ANSI SMT 7.2.1 and 8.2)."
             REFERENCE
                     "ANSI { fddiMAC 25 }"
             ::= { fddimibMACEntry 10 }

         fddimibMACOldUpstreamNbr OBJECT-TYPE
             SYNTAX  FddiMACLongAddressType -- OCTET STRING (SIZE (6))
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "The previous value of the MAC's upstream
                     neighbor's long individual MAC address. It has an
                     initial value of the SMT-Unknown- MAC Address and
                     is only modified as specified by the Neighbor
                     Information Frame protocol (refer to ANSI SMT
                     7.2.1 and 8.2)."
             REFERENCE
                     "ANSI { fddiMAC 26 }"
             ::= { fddimibMACEntry 11 }

         fddimibMACOldDownstreamNbr OBJECT-TYPE
             SYNTAX  FddiMACLongAddressType -- OCTET STRING (SIZE (6))
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "The previous value of the MAC's downstream
                     neighbor's long individual MAC address. It has an
                     initial value of the SMT- Unknown-MAC Address and
                     is only modified as specified by the Neighbor
                     Information Frame protocol (refer to ANSI SMT
                     7.2.1 and 8.2)."
             REFERENCE
                     "ANSI { fddiMAC 27 }"



Case & Rijsinghani                                             [Page 22]

RFC 1512                        FDDI MIB                  September 1993


             ::= { fddimibMACEntry 12 }

         fddimibMACDupAddressTest OBJECT-TYPE
             SYNTAX  INTEGER { none(1), pass(2), fail(3) }
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "The Duplicate Address Test flag, Dup_Addr_Test
                     (refer to ANSI 8.2)."
             REFERENCE
                     "ANSI { fddiMAC 29 }"
             ::= { fddimibMACEntry 13 }

         fddimibMACRequestedPaths OBJECT-TYPE
             SYNTAX  INTEGER  (0..255)
             ACCESS  read-write
             STATUS  mandatory
             DESCRIPTION
                     "List of permitted Paths which specifies the
                     Path(s) into which the MAC may be inserted (refer
                     to ansi SMT 9.7).

                     The value is a sum which represents the individual
                     paths that are desired.  This value initially
                     takes the value zero, then for each type of PATH
                     that this node is, 2 raised to a power is added to
                     the sum.  The powers are according to the
                     following table:

                                        Path   Power
                                       local     0
                         secondary-alternate     1
                           primary-alternate     2
                      concatenated-alternate     3
                         secondary-preferred     4
                           primary-preferred     5
                      concatenated-preferred     6
                                        thru     7 "
             REFERENCE
                     "ANSI { fddiMAC 32 }"
             ::= { fddimibMACEntry 14 }

         fddimibMACDownstreamPORTType OBJECT-TYPE
             SYNTAX  INTEGER { a(1), b(2), s(3), m(4), none(5) }
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "Indicates the PC-Type of the first port that is



Case & Rijsinghani                                             [Page 23]

RFC 1512                        FDDI MIB                  September 1993


                     downstream of this MAC (the exit port)."
             REFERENCE
                     "ANSI { fddiMAC 33 }"
             ::= { fddimibMACEntry 15 }

         fddimibMACSMTAddress OBJECT-TYPE
             SYNTAX  FddiMACLongAddressType -- OCTET STRING (SIZE (6))
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "The 48-bit individual address of the MAC used for
                     SMT frames."
             REFERENCE
                     "ANSI { fddiMAC 41 }"
             ::= { fddimibMACEntry 16 }

         fddimibMACTReq OBJECT-TYPE
             SYNTAX  FddiTimeNano
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "This variable is the T_Req_value passed to the
                     MAC.  Without having detected a duplicate, the
                     time value of this variable shall assume the
                     maximum supported time value which is less than or
                     equal to the time value of fddiPATHMaxT-Req.  When
                     a MAC has an address detected as a duplicate, it
                     may use a time value for this variable greater
                     than the time value of fddiPATHTMaxLowerBound.  A
                     station shall cause claim when the new T_Req may
                     cause the value of T_Neg to change in the claim
                     process, (i.e., time value new T_Req < T_Neg, or
                     old T_Req = T_Neg)."
             REFERENCE
                     "ANSI { fddiMAC 51 }"
             ::= { fddimibMACEntry 17 }

         fddimibMACTNeg OBJECT-TYPE
             SYNTAX  FddiTimeNano
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "It is reported as a FddiTimeNano number."
             REFERENCE
                     "ANSI { fddiMAC 52 }"
             ::= { fddimibMACEntry 18 }

         fddimibMACTMax OBJECT-TYPE



Case & Rijsinghani                                             [Page 24]

RFC 1512                        FDDI MIB                  September 1993


             SYNTAX  FddiTimeNano
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "This variable is the T_Max_value passed to the
                     MAC.  The time value of this variable shall assume
                     the minimum suported time value which is greater
                     than or equal to the time value of fddiPATHT-
                     MaxLowerBound"
             REFERENCE
                     "ANSI { fddiMAC 53 }"
             ::= { fddimibMACEntry 19 }

         fddimibMACTvxValue OBJECT-TYPE
             SYNTAX  FddiTimeNano
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "This variable is the TVX_value passed to the MAC.
                     The time value of this variable shall assume the
                     minimum suported time value which is greater than
                     or equal to the time value of
                     fddiPATHTVXLowerBound."
             REFERENCE
                     "ANSI { fddiMAC 54 }"
             ::= { fddimibMACEntry 20 }

         fddimibMACFrameCts OBJECT-TYPE
             SYNTAX  Counter
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "A count of the number of frames received by this
                     MAC (refer to ANSI MAC 7.5.1)."
             REFERENCE
                     "ANSI { fddiMAC 71 }"
             ::= { fddimibMACEntry 21 }

         fddimibMACCopiedCts OBJECT-TYPE
             SYNTAX  Counter
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "A count that should as closely as possible match
                     the number of frames addressed to (A bit set) and
                     successfully copied into the station's receive
                     buffers (C bit set) by this MAC (refer to ANSI MAC
                     7.5). Note that this count does not include MAC



Case & Rijsinghani                                             [Page 25]

RFC 1512                        FDDI MIB                  September 1993


                     frames."
             REFERENCE
                     "ANSI { fddiMAC 72 }"
             ::= { fddimibMACEntry 22 }

         fddimibMACTransmitCts OBJECT-TYPE
             SYNTAX  Counter
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "A count that should as closely as possible match
                     the number of frames transmitted by this MAC
                     (refer to ANSI MAC 7.5).  Note that this count
                     does not include MAC frames."
             REFERENCE
                     "ANSI { fddiMAC 73 }"
             ::= { fddimibMACEntry 23 }

         fddimibMACErrorCts OBJECT-TYPE
             SYNTAX  Counter
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "A count of the number of frames that were
                     detected in error by this MAC that had not been
                     detected in error by another MAC (refer to ANSI
                     MAC 7.5.2)."
             REFERENCE
                     "ANSI { fddiMAC 81 }"
             ::= { fddimibMACEntry 24 }

         fddimibMACLostCts OBJECT-TYPE
             SYNTAX  Counter
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "A count of the number of instances that this MAC
                     detected a format error during frame reception
                     such that the frame was stripped (refer to ANSI
                     MAC 7.5.3)."
             REFERENCE
                     "ANSI { fddiMAC 82 }"
             ::= { fddimibMACEntry 25 }

         fddimibMACFrameErrorThreshold OBJECT-TYPE
             SYNTAX  INTEGER (0..65535)
             ACCESS  read-write
             STATUS  mandatory



Case & Rijsinghani                                             [Page 26]

RFC 1512                        FDDI MIB                  September 1993


             DESCRIPTION
                     "A threshold for determining when a MAC Condition
                     report (see ANSI 8.3.1.1) shall be generated.
                     Stations not supporting variable thresholds shall
                     have a value of 0 and a range of (0..0)."
             REFERENCE
                     "ANSI { fddiMAC 95 }"
             ::= { fddimibMACEntry 26 }

         fddimibMACFrameErrorRatio OBJECT-TYPE
             SYNTAX  INTEGER (0..65535)
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "This variable is the value of the ratio,

                      ((delta fddiMACLostCts + delta fddiMACErrorCts) /
                      (delta fddiMACFrameCts + delta fddiMACLostCts ))
                      * 2**16 "
             REFERENCE
                     "ANSI { fddiMAC 96 }"
             ::= { fddimibMACEntry 27 }

         fddimibMACRMTState OBJECT-TYPE
             SYNTAX  INTEGER {
                         rm0(1), -- Isolated
                         rm1(2), -- Non_Op
                         rm2(3), -- Ring_Op
                         rm3(4), -- Detect
                         rm4(5), -- Non_Op_Dup
                         rm5(6), -- Ring_Op_Dup
                         rm6(7), -- Directed
                         rm7(8)  -- Trace
                     }
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "Indicates the current state of the RMT State
                     Machine (refer to ANSI 10.3.2)."
             REFERENCE
                     "ANSI { fddiMAC 111 }"
             ::= { fddimibMACEntry 28 }

         fddimibMACDaFlag OBJECT-TYPE
             SYNTAX  INTEGER { true(1), false(2) }
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION



Case & Rijsinghani                                             [Page 27]

RFC 1512                        FDDI MIB                  September 1993


                     "The RMT flag Duplicate Address Flag, DA_Flag
                     (refer to ANSI 10.2.1.2)."
             REFERENCE
                     "ANSI { fddiMAC 112 }"
             ::= { fddimibMACEntry 29 }

         fddimibMACUnaDaFlag OBJECT-TYPE
             SYNTAX  INTEGER { true(1), false(2) }
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "A flag, UNDA_Flag (refer to ANSI 8.2.2.1), set
                     when the upstream neighbor reports a duplicate
                     address condition. Cleared when the condition
                     clears."
             REFERENCE
                     "ANSI { fddiMAC 113 }"
             ::= { fddimibMACEntry 30 }

         fddimibMACFrameErrorFlag OBJECT-TYPE
             SYNTAX  INTEGER { true(1), false(2) }
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "Indicates the MAC Frame Error Condition is
                     present when set. Cleared when the condition
                     clears and on station initialization."
             REFERENCE
                     "ANSI { fddiMAC 114 }"
             ::= { fddimibMACEntry 31 }

         fddimibMACMAUnitdataAvailable OBJECT-TYPE
             SYNTAX  INTEGER { true(1), false(2) }
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "This variable shall take on the value of the
                     MAC_Avail flag defined in RMT."
             REFERENCE
                     "ANSI { fddiMAC 116 }"
             ::= { fddimibMACEntry 32 }

         fddimibMACHardwarePresent OBJECT-TYPE
             SYNTAX  INTEGER { true(1), false(2) }
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "This variable indicates the presence of



Case & Rijsinghani                                             [Page 28]

RFC 1512                        FDDI MIB                  September 1993


                     underlying hardware support for this MAC object.
                     If the value of this object is false(2), the
                     reporting of the objects in this entry may be
                     handled in an implementation-specific manner."
             REFERENCE
                     "ANSI { fddiMAC 117 }"
             ::= { fddimibMACEntry 33 }

         fddimibMACMAUnitdataEnable OBJECT-TYPE
             SYNTAX  INTEGER { true(1), false(2) }
             ACCESS  read-write
             STATUS  mandatory
             DESCRIPTION
                     "This variable determines the value of the
                     MA_UNITDATA_Enable flag in RMT.  The default and
                     initial value of this flag is true(1)."
             REFERENCE
                     "ANSI { fddiMAC 118 }"
             ::= { fddimibMACEntry 34 }


         -- the Enhanced MAC Counters group
         -- Implementation of this Group is optional, but systems
         -- claiming support must implement all variables in this
         -- group


         -- the MAC Counters table

         fddimibMACCountersTable OBJECT-TYPE
             SYNTAX  SEQUENCE OF FddimibMACCountersEntry
             ACCESS  not-accessible
             STATUS  mandatory
             DESCRIPTION
                     "A list of MAC Counters entries.  The number of
                     entries shall not exceed the value of
                     fddimibMACNumber."
             ::= { fddimibMACCounters  1 }

         fddimibMACCountersEntry OBJECT-TYPE
             SYNTAX  FddimibMACCountersEntry
             ACCESS  not-accessible
             STATUS  mandatory
             DESCRIPTION
                     "A MAC Counters entry containing information
                     common to a given MAC."
             INDEX   { fddimibMACSMTIndex, fddimibMACIndex }
             ::= { fddimibMACCountersTable 1 }



Case & Rijsinghani                                             [Page 29]

RFC 1512                        FDDI MIB                  September 1993


         FddimibMACCountersEntry ::=
             SEQUENCE {
                 fddimibMACTokenCts
                         Counter,
                 fddimibMACTvxExpiredCts
                         Counter,
                 fddimibMACNotCopiedCts
                         Counter,
                 fddimibMACLateCts
                         Counter,
                 fddimibMACRingOpCts
                         Counter,
                 fddimibMACNotCopiedRatio
                         INTEGER,
                 fddimibMACNotCopiedFlag
                         INTEGER,
                 fddimibMACNotCopiedThreshold
                         INTEGER
             }

         fddimibMACTokenCts OBJECT-TYPE
             SYNTAX  Counter
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "A count that should as closely as possible match
                     the number of times the station has received a
                     token (total of non-restricted and restricted) on
                     this MAC (see ANSI MAC 7.4). This count is
                     valuable for determination of network load."
             REFERENCE
                     "ANSI { fddiMAC 74 }"
             ::= { fddimibMACCountersEntry 1 }

         fddimibMACTvxExpiredCts OBJECT-TYPE
             SYNTAX  Counter
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "A count that should as closely as possible match
                     the number of times that TVX has expired."
             REFERENCE
                     "ANSI { fddiMAC 83 }"
             ::= { fddimibMACCountersEntry 2 }

         fddimibMACNotCopiedCts OBJECT-TYPE
             SYNTAX  Counter
             ACCESS  read-only



Case & Rijsinghani                                             [Page 30]

RFC 1512                        FDDI MIB                  September 1993


             STATUS  mandatory
             DESCRIPTION
                     "A count that should as closely as possible match
                     the number of frames that were addressed to this
                     MAC but were not copied into its receive buffers
                     (see ANSI MAC 7.5). For example, this might occur
                     due to local buffer congestion. Because of
                     implementation considerations, this count may not
                     match the actual number of frames not copied. It
                     is not a requirement that this count be exact.
                     Note that this count does not include MAC frames."
             REFERENCE
                     "ANSI { fddiMAC 84 }"
             ::= { fddimibMACCountersEntry 3 }

         fddimibMACLateCts OBJECT-TYPE
             SYNTAX  Counter
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "A count that should as closely as possible match
                     the number of TRT expirations since this MAC was
                     reset or a token was received (refer to ANSI MAC
                     7.4.5)."
             REFERENCE
                     "ANSI { fddiMAC 85 }"
             ::= { fddimibMACCountersEntry 4 }

         fddimibMACRingOpCts OBJECT-TYPE
             SYNTAX  Counter
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                      "The count of the number of times the ring has
                     entered the 'Ring_Operational' state from the
                     'Ring Not Operational' state.  This count is
                     updated when a SM_MA_STATUS.Indication of a change
                     in the Ring_Operational status occurs (refer to
                     ANSI 6.1.4). Because of implementation
                     considerations, this count may be less than the
                     actual RingOp_Ct. It is not a requirement that
                     this count be exact."
             REFERENCE
                     "ANSI { fddiMAC 86 }"
             ::= { fddimibMACCountersEntry 5 }

         fddimibMACNotCopiedRatio OBJECT-TYPE
             SYNTAX  INTEGER (0..65535)



Case & Rijsinghani                                             [Page 31]

RFC 1512                        FDDI MIB                  September 1993


             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "This variable is the value of the ratio:

                      (delta fddiMACNotCopiedCts /
                      (delta fddiMACCopiedCts +
                        delta fddiMACNotCopiedCts )) * 2**16 "
             REFERENCE
                     "ANSI { fddiMAC 105 }"
             ::= { fddimibMACCountersEntry 6 }

         fddimibMACNotCopiedFlag OBJECT-TYPE
             SYNTAX  INTEGER { true(1), false(2) }
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "Indicates that the Not Copied condition is
                     present when read as true(1).  Set to false(2)
                     when the condition clears and on station
                     initialization."
             REFERENCE
                     "ANSI { fddiMAC 115 }"
             ::= { fddimibMACCountersEntry 7 }

         fddimibMACNotCopiedThreshold OBJECT-TYPE
             SYNTAX  INTEGER (0..65535)
             ACCESS  read-write
             STATUS  mandatory
             DESCRIPTION
                     "A threshold for determining when a MAC condition
                     report shall be generated.  Stations not
                     supporting variable thresholds shall have a value
                     of 0 and a range of (0..0)."
             REFERENCE
                     "ANSI { fddiMAC 103 }"
             ::= { fddimibMACCountersEntry 8 }


         -- the PATH group
         -- Implementation of the PATH group is mandatory for all
         -- systems which implement manageable FDDI subsystems.

         fddimibPATHNumber OBJECT-TYPE
             SYNTAX  INTEGER (0..65535)
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION



Case & Rijsinghani                                             [Page 32]

RFC 1512                        FDDI MIB                  September 1993


                     "The total number of PATHs possible (across all
                     SMTs) on this network management application
                     entity.  The value for this variable must remain
                     constant at least from one re-initialization of
                     the entity's network management system to the next
                     re-initialization."
             ::= { fddimibPATH  1 }


         -- the PATH table

         fddimibPATHTable OBJECT-TYPE
             SYNTAX  SEQUENCE OF FddimibPATHEntry
             ACCESS  not-accessible
             STATUS  mandatory
             DESCRIPTION
                     "A list of PATH entries.  The number of entries
                     shall not exceed the value of fddimibPATHNumber."
             ::= { fddimibPATH  2 }

         fddimibPATHEntry OBJECT-TYPE
             SYNTAX  FddimibPATHEntry
             ACCESS  not-accessible
             STATUS  mandatory
             DESCRIPTION
                     "A PATH entry containing information common to a
                     given PATH."
             INDEX   { fddimibPATHSMTIndex, fddimibPATHIndex }
             ::= { fddimibPATHTable 1 }

         FddimibPATHEntry ::=
             SEQUENCE {
                 fddimibPATHSMTIndex
                         INTEGER,
                 fddimibPATHIndex
                         INTEGER,
                 fddimibPATHTVXLowerBound
                         FddiTimeNano,
                 fddimibPATHTMaxLowerBound
                         FddiTimeNano,
                 fddimibPATHMaxTReq
                         FddiTimeNano
             }

         fddimibPATHSMTIndex OBJECT-TYPE
             SYNTAX  INTEGER (1..65535)
             ACCESS  read-only
             STATUS  mandatory



Case & Rijsinghani                                             [Page 33]

RFC 1512                        FDDI MIB                  September 1993


             DESCRIPTION
                     "The value of the SMT index associated with this
                     PATH."
             ::= { fddimibPATHEntry 1 }


         fddimibPATHIndex OBJECT-TYPE
             SYNTAX  INTEGER (0..65535)
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "Index variable for uniquely identifying the
                     primary, secondary and local PATH object
                     instances. Local PATH object instances are
                     represented with integer values 3 to 255."
             REFERENCE
                     "ANSI { fddiPATH 11 }"
             ::= { fddimibPATHEntry 2 }

         fddimibPATHTVXLowerBound OBJECT-TYPE
             SYNTAX  FddiTimeNano
             ACCESS  read-write
             STATUS  mandatory
             DESCRIPTION
                     "Specifies the minimum time value of
                     fddiMACTvxValue that shall be used by any MAC that
                     is configured in this path. The operational value
                     of fddiMACTvxValue is managed by settting this
                     variable.  This variable has the time value range
                     of:

                     0 < fddimibPATHTVXLowerBound < fddimibPATHMaxTReq
                     Changes to this variable shall either satisfy the
                     time value relationship:

                     fddimibPATHTVXLowerBound <=
                     fddimibMACTVXCapability

                     of each of the MACs currently on the path, or be
                     considered out of range.  The initial value of
                     fddimibPATHTVXLowerBound shall be 2500 nsec (2.5
                     ms)."
             REFERENCE
                     "ANSI { fddiPATH 21 }"
             ::= { fddimibPATHEntry 3 }

         fddimibPATHTMaxLowerBound OBJECT-TYPE
             SYNTAX  FddiTimeNano



Case & Rijsinghani                                             [Page 34]

RFC 1512                        FDDI MIB                  September 1993


             ACCESS  read-write
             STATUS  mandatory
             DESCRIPTION
                     "Specifies the minimum time value of fddiMACTMax
                     that shall be used by any MAC that is configured
                     in this path.  The operational value of
                     fddiMACTMax is managed by setting this variable.
                     This variable has the time value range of:

                     fddimibPATHMaxTReq <= fddimibPATHTMaxLowerBound

                     and an absolute time value range of:

                     10000nsec (10 msec) <= fddimibPATHTMaxLowerBound

                     Changes to this variable shall either satisfy the
                     time value relationship:

                     fddimibPATHTMaxLowerBound <
                     fddimibMACTMaxCapability

                     of each of the MACs currently on the path, or be
                     considered out of range.  The initial value of
                     fddimibPATHTMaxLowerBound shall be 165000 nsec
                     (165 msec)."
             REFERENCE
                     "ANSI { fddiPATH 22 }"
             ::= { fddimibPATHEntry 4 }

         fddimibPATHMaxTReq OBJECT-TYPE
             SYNTAX  FddiTimeNano
             ACCESS  read-write
             STATUS  mandatory
             DESCRIPTION
                     "Specifies the maximum time value of fddiMACT-Req
                     that shall be used by any MAC that is configured
                     in this path.  The operational value of fddiMACT-
                     Req is managed by setting this variable.  This
                     variable has the time value range of:

                     fddimibPATHTVXLowerBound < fddimibPATHMaxTReq <=
                                              fddimibPATHTMaxLowerBound.

                     The default value of fddimibPATHMaxTReq is 165000
                     nsec (165 msec)."
             REFERENCE
                     "ANSI { fddiPATH 23 }"
             ::= { fddimibPATHEntry 5 }



Case & Rijsinghani                                             [Page 35]

RFC 1512                        FDDI MIB                  September 1993


         -- the PATH Configuration table

         fddimibPATHConfigTable OBJECT-TYPE
             SYNTAX SEQUENCE OF FddimibPATHConfigEntry
             ACCESS not-accessible
             STATUS mandatory
             DESCRIPTION
                     "A table of Path configuration entries.  This
                     table lists all the resources that may be in this
                     Path."
             REFERENCE
                     "ANSI { fddiPATH 18 }"
             ::= { fddimibPATH 3 }

         fddimibPATHConfigEntry OBJECT-TYPE
             SYNTAX FddimibPATHConfigEntry
             ACCESS not-accessible
             STATUS mandatory
             DESCRIPTION
                     "A collection of objects containing information
                     for a given PATH Configuration entry."
             INDEX { fddimibPATHConfigSMTIndex,
                     fddimibPATHConfigPATHIndex,
                     fddimibPATHConfigTokenOrder }
             ::= { fddimibPATHConfigTable 1 }

         FddimibPATHConfigEntry ::=
             SEQUENCE {
                 fddimibPATHConfigSMTIndex
                     INTEGER,
                 fddimibPATHConfigPATHIndex
                     INTEGER,
                 fddimibPATHConfigTokenOrder
                     INTEGER,
                 fddimibPATHConfigResourceType
                     INTEGER,
                 fddimibPATHConfigResourceIndex
                     INTEGER,
                 fddimibPATHConfigCurrentPath
                     INTEGER
             }

         fddimibPATHConfigSMTIndex OBJECT-TYPE
             SYNTAX INTEGER (1..65535)
             ACCESS read-only
             STATUS mandatory
             DESCRIPTION
                     "The value of the SMT index associated with this



Case & Rijsinghani                                             [Page 36]

RFC 1512                        FDDI MIB                  September 1993


                     configuration entry."
             ::= { fddimibPATHConfigEntry 1 }

         fddimibPATHConfigPATHIndex OBJECT-TYPE
             SYNTAX INTEGER (1..65535)
             ACCESS read-only
             STATUS mandatory
             DESCRIPTION
                     "The value of the PATH resource index associated
                     with this configuration entry."
             ::= { fddimibPATHConfigEntry 2 }

         fddimibPATHConfigTokenOrder OBJECT-TYPE
             SYNTAX INTEGER (1..65535)
             ACCESS read-only
             STATUS mandatory
             DESCRIPTION
                     "An object associated with Token order for this
                     entry.  Thus if the token passes resources a, b, c
                     and d, in that order, then the value of this
                     object for these resources would be 1, 2, 3 and 4
                     respectively."
             ::= { fddimibPATHConfigEntry 3 }

         fddimibPATHConfigResourceType OBJECT-TYPE
             SYNTAX INTEGER { mac(2), port(4) }
             ACCESS read-only
             STATUS mandatory
             DESCRIPTION
                     "The type of resource associated with this
                     configuration entry."
             ::= { fddimibPATHConfigEntry 4 }

         fddimibPATHConfigResourceIndex OBJECT-TYPE
             SYNTAX INTEGER (1..65535)
             ACCESS read-only
             STATUS mandatory
             DESCRIPTION
                     "The value of the SMT resource index used to refer
                     to the instance of this MAC or Port resource."
             ::= { fddimibPATHConfigEntry 5 }

         fddimibPATHConfigCurrentPath OBJECT-TYPE
             SYNTAX INTEGER {
                      isolated(1), local(2), secondary(3), primary(4),
                      concatenated(5), thru(6)
                    }
             ACCESS read-only



Case & Rijsinghani                                             [Page 37]

RFC 1512                        FDDI MIB                  September 1993


             STATUS mandatory
             DESCRIPTION
                     "The current insertion status for this resource on
                     this Path."
             ::= { fddimibPATHConfigEntry 6 }


         -- the PORT group
         -- Implementation of the PORT group is mandatory for all
         -- systems which implement manageable FDDI subsystems.

         fddimibPORTNumber OBJECT-TYPE
             SYNTAX  INTEGER (0..65535)
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "The total number of PORT implementations (across
                     all SMTs) on this network management application
                     entity.  The value for this variable must remain
                     constant at least from one re-initialization of
                     the entity's network management system to the next
                     re-initialization."
             ::= { fddimibPORT  1 }


         -- the PORT table

         fddimibPORTTable OBJECT-TYPE
             SYNTAX  SEQUENCE OF FddimibPORTEntry
             ACCESS  not-accessible
             STATUS  mandatory
             DESCRIPTION
                     "A list of PORT entries.  The number of entries
                     shall not exceed the value of fddimibPORTNumber."
             ::= { fddimibPORT  2 }

         fddimibPORTEntry OBJECT-TYPE
             SYNTAX  FddimibPORTEntry
             ACCESS  not-accessible
             STATUS  mandatory
             DESCRIPTION
                     "A PORT entry containing information common to a
                     given PORT."
             INDEX   { fddimibPORTSMTIndex, fddimibPORTIndex }
             ::= { fddimibPORTTable 1 }

         FddimibPORTEntry ::=
             SEQUENCE {



Case & Rijsinghani                                             [Page 38]

RFC 1512                        FDDI MIB                  September 1993


                 fddimibPORTSMTIndex
                         INTEGER,
                 fddimibPORTIndex
                         INTEGER,
                 fddimibPORTMyType
                         INTEGER,
                 fddimibPORTNeighborType
                         INTEGER,
                 fddimibPORTConnectionPolicies
                         INTEGER,
                 fddimibPORTMACIndicated
                         INTEGER,
                 fddimibPORTCurrentPath
                         INTEGER,
                 fddimibPORTRequestedPaths
                         OCTET STRING,
                 fddimibPORTMACPlacement
                         FddiResourceId,
                 fddimibPORTAvailablePaths
                         INTEGER,
                 fddimibPORTPMDClass
                         INTEGER,
                 fddimibPORTConnectionCapabilities
                         INTEGER,
                 fddimibPORTBSFlag
                         INTEGER,
                 fddimibPORTLCTFailCts
                         Counter,
                 fddimibPORTLerEstimate
                         INTEGER,
                 fddimibPORTLemRejectCts
                         Counter,
                 fddimibPORTLemCts
                         Counter,
                 fddimibPORTLerCutoff
                         INTEGER,
                 fddimibPORTLerAlarm
                         INTEGER,
                 fddimibPORTConnectState
                         INTEGER,
                 fddimibPORTPCMState
                         INTEGER,
                 fddimibPORTPCWithhold
                         INTEGER,
                 fddimibPORTLerFlag
                         INTEGER,
                 fddimibPORTHardwarePresent
                         INTEGER,



Case & Rijsinghani                                             [Page 39]

RFC 1512                        FDDI MIB                  September 1993


                 fddimibPORTAction
                         INTEGER
             }

         fddimibPORTSMTIndex OBJECT-TYPE
             SYNTAX  INTEGER (1..65535)
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "The value of the SMT index associated with this
                     PORT."
             ::= { fddimibPORTEntry 1 }

         fddimibPORTIndex OBJECT-TYPE
             SYNTAX  INTEGER (1..65535)
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "A unique value for each PORT within a given SMT,
                     which is the same as the corresponding resource
                     index in SMT.  The value for each PORT must remain
                     constant at least from one re-initialization of
                     the entity's network management system to the next
                     re-initialization."
             REFERENCE
                     "ANSI { fddiPORT 29 }"
             ::= { fddimibPORTEntry 2 }

         fddimibPORTMyType OBJECT-TYPE
             SYNTAX  INTEGER { a(1), b(2), s(3), m(4), none(5) }
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "The value of the PORT's PC_Type (refer to ANSI
                     9.4.1, and 9.6.3.2)."
             REFERENCE
                     "ANSI { fddiPORT 12 }"
             ::= { fddimibPORTEntry 3 }

         fddimibPORTNeighborType OBJECT-TYPE
             SYNTAX  INTEGER { a(1), b(2), s(3), m(4), none(5) }
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "The type of the remote PORT as determined in PCM.
                     This variable has an initial value of none, and is
                     only modified in PC_RCode(3)_Actions (refer to
                     ANSI SMT 9.6.3.2)."



Case & Rijsinghani                                             [Page 40]

RFC 1512                        FDDI MIB                  September 1993


             REFERENCE
                     "ANSI { fddiPORT 13 }"
             ::= { fddimibPORTEntry 4 }

         fddimibPORTConnectionPolicies OBJECT-TYPE
             SYNTAX  INTEGER (0..3)
             ACCESS  read-write
             STATUS  mandatory
             DESCRIPTION
                     "A value representing the PORT's connection
                     policies desired in the node. The value of pc-
                     mac-lct is a term used in the PC_MAC_LCT Flag (see
                     9.4.3.2).  The value of pc-mac-loop is a term used
                     in the PC_MAC_Loop Flag.

                     The value is a sum.  This value initially takes
                     the value zero, then for each PORT policy, 2
                     raised to a power is added to the sum.  The powers
                     are according to the following table:

                                   Policy   Power
                               pc-mac-lct     0
                              pc-mac-loop     1 "
             REFERENCE
                     "ANSI { fddiPORT 14 }"
             ::= { fddimibPORTEntry 5 }

         fddimibPORTMACIndicated OBJECT-TYPE
             SYNTAX  INTEGER {
                         tVal9FalseRVal9False(1),
                         tVal9FalseRVal9True(2),
                         tVal9TrueRVal9False(3),
                         tVal9TrueRVal9True(4)
                     }
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "The indications (T_Val(9), R_Val(9)) in PC-
                     Signalling, of the intent to place a MAC in the
                     output token path to a PORT (refer to ANSI SMT
                     9.6.3.2.)."
             REFERENCE
                     "ANSI { fddiPORT 15 }"
             ::= { fddimibPORTEntry 6 }

         fddimibPORTCurrentPath OBJECT-TYPE
             SYNTAX  INTEGER {
                         ce0(1), -- isolated



Case & Rijsinghani                                             [Page 41]

RFC 1512                        FDDI MIB                  September 1993


                         ce1(2), -- local
                         ce2(3), -- secondary
                         ce3(4), -- primary
                         ce4(5), -- concatenated
                         ce5(6)  -- thru
                     }
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "Indicates the Path(s) into which this PORT is
                     currently inserted."
             REFERENCE
                     "ANSI { fddiPORT 16 }"
             ::= { fddimibPORTEntry 7 }

         fddimibPORTRequestedPaths OBJECT-TYPE
             SYNTAX  OCTET STRING (SIZE (3))
             ACCESS  read-write
             STATUS  mandatory
             DESCRIPTION
                     "This variable is a list of permitted Paths where
                     each list element defines the Port's permitted
                     Paths.  The first octet corresponds to 'none', the
                     second octet to 'tree', and the third octet to
                     'peer'."
             REFERENCE
                     "ANSI { fddiPORT 17 }"
             ::= { fddimibPORTEntry 8 }

         fddimibPORTMACPlacement OBJECT-TYPE
             SYNTAX  FddiResourceId -- INTEGER (0..65535)
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "Indicates the MAC, if any, whose transmit path
                     exits the station via this PORT. The value shall
                     be zero if there is no MAC associated with the
                     PORT. Otherwise, the MACIndex of the MAC will be
                     the value of the variable."
             REFERENCE
                     "ANSI { fddiPORT 18 }"
             ::= { fddimibPORTEntry 9 }

         fddimibPORTAvailablePaths OBJECT-TYPE
             SYNTAX  INTEGER (0..7)
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION



Case & Rijsinghani                                             [Page 42]

RFC 1512                        FDDI MIB                  September 1993


                     "Indicates the Paths which are available to this
                     Port. In the absence of faults, the A and B Ports
                     will always have both the Primary and Secondary
                     Paths available.

                     The value is a sum.  This value initially takes
                     the value zero, then for each type of PATH that
                     this port has available, 2 raised to a power is
                     added to the sum.  The powers are according to the
                     following table:

                              Path   Power
                           Primary     0
                         Secondary     1
                             Local     2 "
             REFERENCE
                     "ANSI { fddiPORT 19 }"
             ::= { fddimibPORTEntry 10 }

         fddimibPORTPMDClass OBJECT-TYPE
             SYNTAX  INTEGER {
                             multimode(1),
                             single-mode1(2),
                             single-mode2(3),
                             sonet(4),
                             low-cost-fiber(5),
                             twisted-pair(6),
                             unknown(7),
                             unspecified(8)
                     }
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "This variable indicates the type of PMD entity
                     associated with this port."
             REFERENCE
                     "ANSI { fddiPORT 22 }"
             ::= { fddimibPORTEntry 11 }

         fddimibPORTConnectionCapabilities OBJECT-TYPE
             SYNTAX  INTEGER (0..3)
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "A value that indicates the connection
                     capabilities of the port. The pc-mac-lct bit
                     indicates that the station has the capability of
                     setting the PC_MAC_LCT Flag. The pc-mac-loop bit



Case & Rijsinghani                                             [Page 43]

RFC 1512                        FDDI MIB                  September 1993


                     indicates that the station has the capability of
                     setting the PC_MAC_Loop Flag (refer to ANSI
                     9.4.3.2).

                     The value is a sum.  This value initially takes
                     the value zero, then for each capability that this
                     port has, 2 raised to a power is added to the sum.
                     The powers are according to the following table:

                        capability   Power
                        pc-mac-lct     0
                       pc-mac-loop     1 "
             REFERENCE
                     "ANSI { fddiPORT 23 }"
             ::= { fddimibPORTEntry 12 }

         fddimibPORTBSFlag OBJECT-TYPE
             SYNTAX  INTEGER { true(1), false(2) }
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "This variable assumes the value of the BS_Flag
                     (refer to ANSI SMT 9.4.3.3)."
             REFERENCE
                     "ANSI { fddiPORT 33 }"
             ::= { fddimibPORTEntry 13 }

         fddimibPORTLCTFailCts OBJECT-TYPE
             SYNTAX  Counter
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "The count of the consecutive times the link
                     confidence test (LCT) has failed during connection
                     management (refer to ANSI 9.4.1)."
             REFERENCE
                     "ANSI { fddiPORT 42 }"
             ::= { fddimibPORTEntry 14 }

         fddimibPORTLerEstimate OBJECT-TYPE
             SYNTAX  INTEGER (4..15)
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "A long term average link error rate. It ranges
                     from 10**-4 to 10**-15 and is reported as the
                     absolute value of the base 10 logarithm (refer to
                     ANSI SMT 9.4.7.5.)."



Case & Rijsinghani                                             [Page 44]

RFC 1512                        FDDI MIB                  September 1993


             REFERENCE
                     "ANSI { fddiPORT 51 }"
             ::= { fddimibPORTEntry 15 }

         fddimibPORTLemRejectCts OBJECT-TYPE
             SYNTAX  Counter
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "A link error monitoring count of the times that a
                     link has been rejected."
             REFERENCE
                     "ANSI { fddiPORT 52 }"
             ::= { fddimibPORTEntry 16 }

         fddimibPORTLemCts OBJECT-TYPE
             SYNTAX  Counter
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "The aggregate link error monitor error count, set
                     to zero only on station initialization."
             REFERENCE
                     "ANSI { fddiPORT 53 }"
             ::= { fddimibPORTEntry 17 }

         fddimibPORTLerCutoff OBJECT-TYPE
             SYNTAX  INTEGER (4..15)
             ACCESS  read-write
             STATUS  mandatory
             DESCRIPTION
                      "The link error rate estimate at which a link
                     connection will be broken. It ranges from 10**-4
                     to 10**-15 and is reported as the absolute value
                     of the base 10 logarithm (default of 7)."
             REFERENCE
                     "ANSI { fddiPORT 58 }"
             ::= { fddimibPORTEntry 18 }

         fddimibPORTLerAlarm OBJECT-TYPE
             SYNTAX  INTEGER (4..15)
             ACCESS  read-write
             STATUS  mandatory
             DESCRIPTION
                     "The link error rate estimate at which a link
                     connection will generate an alarm. It ranges from
                     10**-4 to 10**-15 and is reported as the absolute
                     value of the base 10 logarithm of the estimate



Case & Rijsinghani                                             [Page 45]

RFC 1512                        FDDI MIB                  September 1993


                     (default of 8)."
             REFERENCE
                     "ANSI { fddiPORT 59 }"
             ::= { fddimibPORTEntry 19 }

         fddimibPORTConnectState OBJECT-TYPE
             SYNTAX  INTEGER {
                         disabled(1),
                         connecting(2),
                         standby(3),
                         active(4)
                     }
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "An indication of the connect state of this PORT
                     and is equal to the value of Connect_State (refer
                     to ANSI 9.4.1)"
             REFERENCE
                     "ANSI { fddiPORT 61 }"
             ::= { fddimibPORTEntry 20 }

         fddimibPORTPCMState OBJECT-TYPE
             SYNTAX  INTEGER {
                         pc0(1), -- Off
                         pc1(2), -- Break
                         pc2(3), -- Trace
                         pc3(4), -- Connect
                         pc4(5), -- Next
                         pc5(6), -- Signal
                         pc6(7), -- Join
                         pc7(8), -- Verify
                         pc8(9), -- Active
                         pc9(10) -- Maint
                     }
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "The state of this Port's PCM state machine refer
                     to ANSI SMT 9.6.2)."
             REFERENCE
                     "ANSI { fddiPORT 62 }"
             ::= { fddimibPORTEntry 21 }

         fddimibPORTPCWithhold OBJECT-TYPE
             SYNTAX  INTEGER {
                          none(1),
                          m-m(2),



Case & Rijsinghani                                             [Page 46]

RFC 1512                        FDDI MIB                  September 1993


                          otherincompatible(3),
                          pathnotavailable(4)
                     }
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "The value of PC_Withhold (refer to ANSI SMT
                     9.4.1)."
             REFERENCE
                     "ANSI { fddiPORT 63 }"
             ::= { fddimibPORTEntry 22 }

         fddimibPORTLerFlag OBJECT-TYPE
             SYNTAX  INTEGER { true(1), false(2) }
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "The condition becomes active when the value of
                     fddiPORTLerEstimate is less than or equal to
                     fddiPORTLerAlarm. This will be reported with the
                     Status Report Frames (SRF) (refer to ANSI SMT
                      7.2.7 and 8.3)."
             REFERENCE
                     "ANSI { fddiPORT 64 }"
             ::= { fddimibPORTEntry 23 }

         fddimibPORTHardwarePresent OBJECT-TYPE
             SYNTAX  INTEGER { true(1), false(2) }
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "This variable indicates the presence of
                     underlying hardware support for this Port object.
                     If the value of this object is false(2), the
                     reporting of the objects in this entry may be
                     handled in an implementation-specific manner."
             REFERENCE
                     "ANSI { fddiPORT 65 }"
             ::= { fddimibPORTEntry 24 }

         fddimibPORTAction OBJECT-TYPE
             SYNTAX  INTEGER {
                     other(1),           -- none of the following
                     maintPORT(2),
                     enablePORT(3),
                     disablePORT(4),
                     startPORT(5),
                     stopPORT(6)



Case & Rijsinghani                                             [Page 47]

RFC 1512                        FDDI MIB                  September 1993


                     }
             ACCESS  read-write
             STATUS  mandatory
             DESCRIPTION
                     "Causes a Control signal to be generated with a
                     control_action of 'Signal' and the 'variable'
                     parameter set with the appropriate value (i.e.,
                     PC_Maint, PC_Enable, PC_Disable, PC_Start, or
                     PC_Stop) (refer to ANSI 9.4.2)."
             REFERENCE
                     "ANSI { fddiPORT 70 }"
             ::= { fddimibPORTEntry 25 }


         END

5.  Acknowledgements

  This document was produced by the IETF FDDI MIB working group:

              Hossein Alaee, 3Com Corporation
              Haggar Alsaleh, Bell Northern Research
              William Anderson, Mitre Corporation
              Alan Apt, Addison-Wesley
              Mary Artibee, Silicon Graphics
              Karen Auerbach, Epilogue Technologies
              Doug Bagnall, Apollo/Hewlett Packard
              Chet Birger, Coral Network Corporation
              Pablo Brenner, Fibronics
              Howard Brown, Cabletron
              Jack Brown, US Army Computer Engineering Center
              Eric Brunner
              Jeff Case, The University of Tennessee
              Tammy Chan, Fibercom
              Asheem Chandna, AT&T
              Cho Y. Chang, Apollo/Hewlett Packard
              Chris Chiotasso, Fibronics
              Paul Ciarfella, Digital Equipment Corporation
              John Cook, Chipcom
              Don Coolidge, Silicon Graphics
              Burt Cyr, Unisys
              James R. Davin, Massachusetts Institute of Technology
              Nabil Damouny
              Nadya El-Afandi, Network Systems Corporation
              Hunaid Engineer, Cray Research
              Jeff Fitzgerald, Fibercom
              Richard Fox, Synoptics
              Stan Froyd, ACC



Case & Rijsinghani                                             [Page 48]

RFC 1512                        FDDI MIB                  September 1993


              Debbie Futcher, U.S. Naval Surface Warfare Center
              Joseph Golio, Cray Research
              Jeremy Greene, Coral
              Peter Hayden, Digital Equipment Corporation
              Scott Hiles, U.S. Naval Surface Warfare Center
              Greg Jones, Data General
              Satish Joshi, SynOptics Communications
              Jayant Kadambi, AT&T Bell Labs
              Joanna Karwowska, Data General
              Frank Kastenholz, Interlan
              Jim Kinder, Fibercom
              Christopher Kolb, PSI
              Cheryl Krupczak, NCR
              Peter Lin, Vitalink
              Then Liu
              John R. LoVerso, Concurrent Computer Corporation
              Ron Mackey, Distributed Systems International, Inc.
              Gary Malkin, Proteon
              Bruce McClure, Synernetics
              Keith McCloghrie, Hughes Lan Systems
              Donna McMaster, SynOptics
              John O'Hara, Massachusetts Institute of Technology
              Luc Pariseau, Digital Equipment Corporation
              Dave Perkins, SynOptics Communications
              James E. Reeves, SynOptics Communications
              Jim Reinstedler, Ungermann-Bass
              Radhi Renous, Fibronics
              Sal Ricci, AT&T/NCR
              Anil Rijsinghani, Digital Equipment Corporation
              Bob Rolla, Synernetics
              Nelson Ronkin, Synernetics
              Marshall T. Rose, Performance Systems International, Inc.
              Milt Roselinsky, CMC
              Jon Saperia, Digital Equipment Corporation
              Greg Satz, cisco Systems
              Steven Senum, Network Systems Corporation
              Jim Sheridan, IBM Corporation
              Jeffrey Schiller, MIT
              Dror Shindelman, Fibronics
              Mark Sleeper, Sparta
              Lou Steinberg, IBM Corporation
              Larry Stefani, Digital Equipment Corporation
              Mary Jane Strohl, Apollo/Hewlett Packard
              Sally Tarquinio, Mitre Corporation
              Kaj Tesink, Bellcore
              Ian Thomas, Chipcom
              Dean Throop, Data General
              Bill Townsend, Xylogics



Case & Rijsinghani                                             [Page 49]

RFC 1512                        FDDI MIB                  September 1993


              Ahmet H. Tuncay, SynOptics Communications
              Mike Turico, Motorola
              Chris VandenBerg, ACC
              Sudhanshu Verma, Hewlett Packard
              Joe Vermeulen, UNISYS
              David Waiteman, BBN
              Bert Williams, Synernetics
              Mark Wood, Distributed Systems International, Inc.
              Y. C. Yang
              Denis Yaro, Sun Microsystems
              Jeff Young, Cray Research

  The author gratefully acknowledges the labors of Judi Talley and
  David Reid of SNMP Research, Inc. for their editorial assistance in
  the preparation of this document.

6.  References

  [1]  Rose M., and K. McCloghrie, "Structure and Identification of
       Management Information for TCP/IP-based internets", STD 16, RFC
       1155, Performance Systems International, Hughes LAN Systems, May
       1990.

  [2]  Case, J., "FDDI Management Information Base", RFC 1285, SNMP
       Research, Incorporated, January 1992.

  [3]  Case, J., Fedor, M., Schoffstall, M., and J. Davin, "Simple
       Network Management Protocol", STD 15, RFC 1157, SNMP Research,
       Performance Systems International, Performance Systems
       International, MIT Laboratory for Computer Science, May 1990.

  [4]  McCloghrie K., and M. Rose, Editors, "Management Information
       Base for Network Management of TCP/IP-based internets", STD 17,
       RFC 1213, Performance Systems International, March 1991.

  [5]  Information processing systems - Open Systems Interconnection -
       Specification of Abstract Syntax Notation One (ASN.1),
       International Organization for Standardization.  International
       Standard 8824, (December, 1987).

  [6]  Information processing systems - Open Systems Interconnection -
       Specification of Basic Encoding Rules for Abstract Notation One
       (ASN.1), International Organization for Standardization.
       International Standard 8825, (December, 1987).

  [7]  Rose, M., and K. McCloghrie, Editors, "Concise MIB Definitions",
       STD 16, RFC 1212, Performance Systems International, Hughes LAN
       Systems, March 1991.



Case & Rijsinghani                                             [Page 50]

RFC 1512                        FDDI MIB                  September 1993


  [8]  American National Standards Institute, FDDI Station Management
       (SMT), Draft Proposed American National Standard, American
       National Standards Institute, X3T9.5/84-49 REV 7.3.

7. Security Considerations

  Security issues are not discussed in this memo.

8. Authors' Addresses

  Jeffrey D. Case
  The University of Tennessee
  Department of Computer Science
  107 Ayres Hall
  Knoxville, Tennessee  37996

  and

  SNMP Research, Incorporated
  3001 Kimberlin Heights Road
  Knoxville, Tennessee  37920

  Phone: (615) 974-5067 or (615) 573-1434
  EMail: [email protected]


  Anil Rijsinghani
  Digital Equipment Corporation
  295 Foster Street
  Littleton, MA 01460-1123

  Phone: (508) 952-3520
  EMail: [email protected]