; MXO-MR10.ASM - Morrow Micro Decision MD-11 overlay file for MEX
;                or MDM712.
; 6/28/84
;
;  (Adapted from M712MD.ASM, originally for Morrow MD-2 & MD-3)
;
; You will want to look this file over carefully. There are a number of
; options that you can use to configure the program to suit your taste.
; This file adapts either modem program to the Morrow MD-11 computer.
; (It is not for use with the Morrow MD-2 or MD-3 computers.)
; While this computer has a number of serial ports, one is used for the
; terminal and the another for the printer/modem.  To use this
; overlay, you must use the CP/M program "SETUP" to set the printer/
; modem port to 1200 baud.  (This is usually done automatically upon
; a boot.)  Configure the internal jumpers to make the port a DTE
; type of device (page D-16 in my MD-11 User's Guide) for use with
; modems.
;
; Edit this file for your preferences then follow the "TO USE:" example
; shown below.
;
; Use the "SET" command to change the baudrate when desired.  It starts
; out at 1200 baud when the program is first called up.  If you exit
; the program while at 300 baud, re-boot the Morrow before proceeding
; in order to reprogram the Zilog DART to the correct clock ratio.
; (The SET command alters the DART clock divide ratio, not the
; clock frequency itself).  Exiting the program when set to 1200
; baud causes no such concern. (This advice only applies to usage
; of the SET command).
;
;       TO USE: First edit this file filling in answers for your own
;               equipment.  Then assemble with ASM.COM or equivalent
;               assembler.  Then use DDT to overlay the the results
;               of this program on the original MDM712.COM file (or
;               follow the instructions with MEX to overlay MEX10.COM).
;
;               For MDM712:
;
;               A>SAVE
;               A>DDT MDM712.COM
;               DDT VERS 2.2
;               NEXT  PC
;               4300 0100
;               -IMXO-MR10.HEX          (note the "I" command)
;               -R                      ("R" loads in the .HEX file)
;               NEXT  PC
;               4300 0000
;               -G0                     (that's a zero: return to CP/M)
;
;               CP/M 3 SAVE - Version 3.0
;               Enter file (type RETURN to exit): MODEM7.COM
;               Beginning hex address 0100
;               Ending hex address    4300
;               A>
;
;               You now have MODEM7.COM (or MEX.COM) for use on the
;               Morrow MD-11.
;
;
; =   =   =   =   =   =   =   =   =   =   =   =   =   =   =   =   =   =
;
; 06/28/84 - Further revisions & renamed for MEX- Steve Reyer
; 05/28/84 - Revised for use on Morrow MD-11    - Steve Reyer
; 07/21/83 - Renamed for use with MDM712        - Irv Hoff
; 07/01/83 - Revised for use with MDM711        - Irv Hoff
; 06/22/83 - Revised for use with MDM710        - Irv Hoff
; 06/22/83 - Altered MDM708DP for Morrow
;            Micro Decision computers using
;            an external modem                  - Irv Hoff
;
; =   =   =   =   =   =   =   =   =   =   =   =   =   =   =   =   =   =
;
BELL:           EQU     07H             ;bell
CR:             EQU     0DH             ;carriage return
ESC:            EQU     1BH             ;escape
LF:             EQU     0AH             ;linefeed
;
YES:            EQU     0FFH
NO:             EQU     0
;
;
PORT:           EQU     62H             ;Morrow MD-11 prt/modem port
MODCTL1:        EQU     PORT+1          ;Modem status port
MODDATP:        EQU     PORT            ;Modem data port
MODCTL2:        EQU     PORT+1          ;Modem control port
;
; The following was added by Reyer to define the Zilog DART
;
MODSNDB:        EQU     04H             ;bit to test for send
MODSNDR         EQU     04H             ;value when ready
MODRCVB         EQU     01H             ;bit to test for recv
MODRCVR         EQU     01H             ;value when ready
;
;
               ORG     100H
;
               DS      3       ;(for  "JMP   START" instruction)
;


PMMIMODEM:      DB      NO      ;yes=PMMI S-100 Modem                   103H
SMARTMODEM:     DB      YES     ;yes=HAYES Smartmodem, no=non-PMMI      104H
TOUCHPULSE:     DB      'T'     ;T=Touch, P=Pulse (Smartmodem-only)     105H
CLOCK:          DB      40      ;clock speed in MHz x10, 25.5 MHz max.  106H
                               ;20=2 MHh, 37=3.68 MHz, 40=4 MHz, etc.
MSPEED:         DB      5       ;0=110 1=300 2=450 3=600 4=710 5=1200   107H
                               ;6=2400 7=4800 8=9600 9=19200 default
BYTDLY:         DB      5       ;0=0 delay  1=10ms  5=50 ms - 9=90 ms   108H
                               ;default time to send character in ter-
                               ;minal mode file transfer for slow BBS.
CRDLY:          DB      5       ;0=0 delay 1=100 ms 5=500 ms - 9=900 ms 109H
                               ;default time for extra wait after CRLF
                               ;in terminal mode file transfer
NOOFCOL:        DB      5       ;number of DIR columns shown            10AH
SETUPTST:       DB      YES     ;yes=user-added Setup routine           10BH
SCRNTEST:       DB      YES     ;Cursor control routine                 10CH
ACKNAK:         DB      YES     ;yes=resend a record after any non-ACK  10DH
                               ;no=resend a record after a valid NAK
BAKUPBYTE:      DB      NO      ;yes=change any file same name to .BAK  10EH
CRCDFLT:        DB      YES     ;yes=default to CRC checking            10FH
TOGGLECRC:      DB      YES     ;yes=allow toggling of CRC to Checksum  110H
CONVBKSP:       DB      NO      ;yes=convert backspace to rub           111H
TOGGLEBK:       DB      YES     ;yes=allow toggling of bksp to rub      112H
ADDLF:          DB      NO      ;no=no LF after CR to send file in      113H
                               ;terminal mode (added by remote echo)
TOGGLELF:       DB      YES     ;yes=allow toggling of LF after CR      114H
TRANLOGON:      DB      YES     ;yes=allow transmission of logon        115H
                               ;write logon sequence at location LOGON
SAVCCP:         DB      YES     ;yes=do not overwrite CCP               116H
LOCONEXTCHR:    DB      NO      ;yes=local command if EXTCHR precedes   117H
                               ;no=external command if EXTCHR precedes
TOGGLELOC:      DB      YES     ;yes=allow toggling of LOCONEXTCHR      118H
LSTTST:         DB      YES     ;no=using modem on printer port         119H
XOFFTST:        DB      YES     ;yes=checks for XOFF from remote while  11AH
                               ;sending a file in terminal mode
XONWAIT:        DB      NO      ;yes=wait for XON after CR while        11BH
                               ;sending a file in terminal mode
TOGXOFF:        DB      YES     ;yes=allow toggling of XOFF checking    11CH
IGNORCTL:       DB      YES     ;yes=CTL-chars above ^M not displayed   11DH
EXTRA1:         DB      0       ;for future expansion                   11EH
EXTRA2:         DB      0       ;for future expansion                   11FH
BRKCHR:         DB      '@'-40H ;^@ = Send 300 ms. break tone           120H
NOCONNCT:       DB      'N'-40H ;^N = Disconnect from phone line        121H
LOGCHR:         DB      'L'-40H ;^L = Send logon                        122H
LSTCHR:         DB      'P'-40H ;^P = Toggle printer                    123H
UNSAVE:         DB      'R'-40H ;^R = Close input text buffer           124H
TRANCHR:        DB      'T'-40H ;^T = Transmit file to remote           125H
SAVECHR:        DB      'Y'-40H ;^Y = Open input text buffer            126H
EXTCHR:         DB      '^'-40H ;^^ = Send next character               127H
;
;
               DS      2               ;                               128H
;
IN$MODCTL1:     IN      MODCTL1 ! RET   ;in modem control port          12AH
               DS      7
OUT$MODDATP:    OUT     MODDATP ! RET   ;out modem data port            134H
               DS      7
IN$MODDATP:     IN      MODDATP ! RET   ;in modem data port             13EH
               DS      7               ;
;
ANI$MODRCVB:    ANI     MODRCVB ! RET   ;Reyer: These lines were
CPI$MODRCVR:    CPI     MODRCVR ! RET   ;added to make it similar to
ANI$MODSNDB:    ANI     MODSNDB ! RET   ;similar overlays where the
CPI$MODSNDR     CPI     MODSNDR ! RET   ;UART flags needed testing
               DS      12              ;
;
;
LOGONPTR:       DW      LOGON           ;for user message.              160H
               DS      6               ;                               162H
JMP$GOODBYE:    JMP     GOODBYE         ;                               168H
JMP$INITMOD:    JMP     INITMOD         ;go to user written routine     16BH
               RET  !  NOP  !  NOP     ;(by-passes PMMI routine)       16EH
               RET  !  NOP  !  NOP     ;(by-passes PMMI routine)       171H
               RET  !  NOP  !  NOP     ;(by-passes PMMI routine)       174H
JMP$SETUPR:     JMP     SETUPR          ;                               177H
JMP$SPCLMENU:   JMP     SPCLMENU        ;                               17AH
JMP$SYSVER:     JMP     SYSVER          ;                               17DH
JMP$BREAK:      JMP     SENDBRK         ;                               180H
;
;
; Do not change the following six lines.
;
JMP$ILPRT:      DS      3               ;                               183H
JMP$INBUF       DS      3               ;                               186H
JMP$INLNCOMP:   DS      3               ;                               189H
JMP$INMODEM     DS      3               ;                               18CH
JMP$NXTSCRN:    DS      3               ;                               18FH
JMP$TIMER:      DS      3               ;                               192H
;
; Clear sequences -- CLREOS is clear to end of screen, CLRSCRN is clear
; entire screen.  Last entry must be 0.  Any other 0's act as NOP's.
; The SCRNTST option must be set "YES" for these to work.  These are now
; set for the Morrow MDT-60 terminal.
;
CLREOS:         CALL    JMP$ILPRT       ;                               195H
               DB      ESC,'Y',0,0,0   ;                               198H
               RET                     ;                               19DH
;
CLRSCRN:        CALL    JMP$ILPRT       ;                               19EH
               DB      ESC,'*',0,0,0   ;                               1A1H
               RET                     ;                               1A6H
;
;
SYSVER:         CALL    JMP$ILPRT       ;                               1A7H
               DB      'Version for Morrow MD-11 hard-disk computer'
               DB      CR,LF,0
               RET
;.....
;
;
;-----------------------------------------------------------------------
;
; NOTE:  You can change the SYSVER message to be longer or shorter.  The
;        end of your last routine should terminate by 0400H (601 bytes
;        available after start of SYSVER) if using the Hayes Smartmodem
;        or by address 0C00H (2659 bytes) otherwise.
;
;-----------------------------------------------------------------------
;
; You can put in a message at this location which can be called up with
; CTL-O if TRANLOGON has been set YES.  You can put in several lines if
; desired.  End with a 0.
;
;
LOGON:    DB    'This is a Morrow MD-11 computer',CR,LF,0
;.....
;
;
;=======================================================================
; Extensive changes from the original Morrow overlay, M712MD.ASM
; have been made below by Reyer to accomodate the MD-11 and its
; Zilog DART (Dual UART).  Notation such as "REG. 5" refers to
; write-registers in the Zilog DART.
;
; This routine allows a 300 ms. break tone to be sent to reset some
; time-share computers.
;
SENDBRK:  MVI   A,05H           ;SELECT REG. 5
         OUT   MODCTL1
         MVI   A,0FAH          ;SEND BREAK ONLY
         OUT   MODCTL1
         JMP   GOODBYE1        ;GO TO WAIT
;...
;
;
; This routine sends a 300 ms. break tone and sets DTR low for the same
; length of time to disconnect some modems such as the Bell 212A, etc.
;
GOODBYE:  MVI   A,05H           ;REG. 5
         OUT   MODCTL1
         MVI   A,7AH           ;DTR OFF AND BREAK SENT
         OUT   MODCTL1
GOODBYE1: MVI   B,3             ;300 MS.
         CALL  JMP$TIMER
         MVI   A,05H           ;REG. 5
         OUT   MODCTL1
         MVI   A,0EAH          ;DTR ON, NO BREAK
         OUT   MODCTL1
         RET
;
;
;
;.....
;
;
; No initialization other than using SETUP (if needed) from
; CP/M is required.  The following is part of the SET
; command code.  (see OK300, OK1200, LOADBD, below).
;
INITMOD:  MVI   A,5             ;TRANSFER TIME FOR 1200 BAUD
         STA   MSPEED
         MVI   A,04H           ;SELECT REG. 4
         OUT   MODCTL1
INITMOD1: MVI   A,44H           ;DEFAULT TO /16 FOR 1200 BAUD
         OUT   MODCTL1
         IN    PORT            ;CLEAR DATA PORT
         RET
;.....
;
;
SETUPR:   LXI   D,BAUDBUF       ;POINT TO NEW INPUT BUFFER
         CALL  JMP$ILPRT
         DB    'Input Baud Rate (300, 1200): ',0
         CALL  JMP$INBUF
         LXI   D,BAUDBUF+2
         CALL  JMP$INLNCOMP    ;COMPARE BAUDBUF+2 WITH CHARACTERS BELOW
         DB    '300',0
         JNC   OK300           ;GO IF GOT MATCH
         CALL  JMP$INLNCOMP
         DB    '1200',0
         JNC   OK1200
         CALL  JMP$ILPRT       ;ALL MATCHES FAILED, TELL OPERATOR
         DB    '++ Incorrect entry ++',CR,LF,BELL,0
         JMP   SETUPR          ;TRY AGAIN
;
OK300:    MVI   A,1             ;MSPEED 300 BAUD VALUE
         MVI   B,0C4H          ;DIVIDE BY 64 FOR 300 BAUD
         JMP   LOADBD          ;GO LOAD THEM
;
OK1200:   MVI   A,5
         MVI   B,44H           ;DIVIDE BY 16 FOR 1200 BAUD
;
;
LOADBD:   STA   INITMOD+1       ;CHANGE TIME-TO-SEND TO MATCH BAUDRATE
         MOV   A,B             ;GET BAUDRATE BYTE
         STA   INITMOD1+1      ;STORE IN INITMOD
         JMP   INITMOD         ;REINITIALIZE TO NEW BAUDRATE, THEN DONE
;
;
BAUDBUF:  DB    10,0
         DS    10
;.....
;
;
;              (END OF INITMOD AND SETUP ROUTINES)
;=======================================================================
;
;
; These routines can be used for your equipment, be sure to end with RET
;
SPCLMENU: RET
;
;=======================================================================
;
;
; NOTE:  MUST TERMINATE PRIOR TO 0400H (with Smartmodem)
;                                0C00H (without Smartmodem).
;
         END
;