; M8IN-1.A86 -- Overlay file for the CompuPro I3/I4.  09/14/84
;
; This overlay adapts the MDM8xx program to the CompuPro Interfacer 3 or
; Interfacer 4 serial cards using the 2651 USART chip.
;
; You will want to look this file over carefully. There are a number of
; options that you can use to configure the program to suit your taste.
; This file places particular emphasis on using an external modem that
; is connected to a serial port.  This includes acoustic modems as well
; as "intelligent" modems such as the Hayes Smartmodem, Racal-Vadic, Bell
; Dataphone 212A, etc.
;
; This overlay is capable of setting the baud rate, disconnecting the
; modem, and sending breaks.
;
;
;       TO USE: First edit this file filling in answers for your own
;               equipment.  Then assemble with ASM86.CMD or equivalent
;               assembler.  Then use M8CNFG to overlay the the results
;               of this program to the original MDM8xx.H86 file:
;
;                       ASM86 M8IN-1
;                       REN M8OVL.H86=M8IN-1.H86
;                       M8CNFG
;                       GENCMD MDM 8080 CODE[MFF0]
;
;                Now run MDM.  Have Fun
;
;
; =   =   =   =   =   =   =   =   =   =   =   =   =   =   =   =   =   =
;
; 09/19/84 - Original version for MDM8xx        - Alex Soya
; 04/04/84 - First version of this file         - Irv Hoff
;
; =   =   =   =   =   =   =   =   =   =   =   =   =   =   =   =   =
;
BELL    EQU     07H             ;bell
CR      EQU     0DH             ;carriage return
ESC     EQU     1BH             ;escape
LF      EQU     0AH             ;linefeed
;
YES     EQU     0FFH
NO      EQU     0
;
; Change the following to match your equipment
;
; =   =   =   =   =   =   =   =   =   =   =   =   =   =   =   =   =
;
BASE    EQU     010H            ;base port of CompuPro I3 or I4 cards
UPORT   EQU     BASE+7          ;user (chip select) port
MDM     EQU     6               ;chip that controls modem port
;
;
;
DPORT   EQU     BASE            ;data port
SPORT   EQU     BASE+1          ;status port
MPORT   EQU     BASE+2          ;mode port
CPORT   EQU     BASE+3          ;control port
;
TBMT    EQU     01H             ;transmit buffer empty
DAV     EQU     02H             ;data available
;
       ORG     100H
;
; Change the clock speed to suit your system
;
               RS      3       ;(for  "JMP   START" instruction)
;
PMMIMODEM       DB      NO      ;yes=PMMI S-100 Modem                   103H
AUTODIAL        DB      YES     ;yes=HAYES-like modem, no=non-PMMI      104H
TOUCHPULSE      DB      'T'     ;T=touch, P=pulse (Smartmodem-only)     105H
CLOCK           DB      80      ;clock speed in MHz x10, 25.5 MHz max.  106H
                               ;20=2 MHh, 37=3.68 MHz, 40=4 MHz, etc.
MSPEED          DB      1       ;0=110 1=300 2=450 3=600 4=710 5=1200   107H
                               ;6=2400 7=4800 8=9600 9=19200 default
BYTDLY          DB      5       ;0=0 delay  1=10ms  5=50 ms - 9=90 ms   108H
                               ;default time to send character in ter-
                               ;minal mode file transfer for slow BBS.
CRDLY           DB      5       ;0=0 delay 1=100 ms 5=500 ms - 9=900 ms 109H
                               ;default time for extra wait after CRLF
                               ;in terminal mode file transfer
NOOFCOL         DB      5       ;number of DIR columns shown            10AH
SETUPTST        DB      YES     ;yes=user-added Setup routine           10BH
SCRNTEST        DB      YES     ;cursor control routine                 10CH
RETRY           DB      NO      ;yes=reset the error limit to try again 10DH
                               ;no=abort after 10 consecurive errors
BAKUPBYTE       DB      NO      ;yes=change any file same name to .BAK  10EH
CRCDFLT         DB      YES     ;yes=default to CRC checking            10FH
TOGGLECRC       DB      YES     ;yes=allow toggling of CRC to Checksum  110H
CONVRUB         DB      NO      ;yes=convert rub to backspace           111H
TOGGLERUB       DB      YES     ;yes=allow toggling of rub to backspace 112H
ADDLF           DB      NO      ;no=no LF after CR to send file in      113H
                               ;terminal mode (added by remote echo)
TOGGLELF        DB      YES     ;yes=allow toggling of LF after CR      114H
TRANLOGON       DB      YES     ;yes=allow transmission of logon        115H
                               ;write logon sequence at location LOGON
RESERVED        DB      NO      ;resevered for future release           116H
LOCONEXTCHR     DB      NO      ;yes=local command if EXTCHR precedes   117H
                               ;no=external command if EXTCHR precedes
TOGGLELOC       DB      YES     ;yes=allow toggling of LOCONEXTCHR      118H
LSTTST          DB      YES     ;yes=printer available on printer port  119H
XOFFTST         DB      NO      ;yes=checks for XOFF from remote while  11AH
                               ;sending a file in terminal mode
XONWAIT         DB      NO      ;yes=wait for XON after CR while        11BH
                               ;sending a file in terminal mode
TOGXOFF         DB      YES     ;yes=allow toggling of XOFF checking    11CH
IGNORCTL        DB      YES     ;yes=CTL-chars above ^M not displayed   11DH
EXTRA1          DB      0       ;for future expansion                   11EH
EXITCHR         DB      'E'-40H ;^E = Exit to main menu                 11FH
BRKCHR          DB      '@'-40H ;^@ = Send 300 ms. break tone           120H
NOCONNCT        DB      'N'-40H ;^N = Disconnect from the phone line    121H
LOGCHR          DB      'L'-40H ;^L = Send logon                        122H
LSTCHR          DB      'P'-40H ;^P = Toggle printer                    123H
UNSAVE          DB      'R'-40H ;^R = Close input text buffer           124H
TRANCHR         DB      'T'-40H ;^T = Transmit file to remote           125H
SAVECHR         DB      'Y'-40H ;^Y = Open input text buffer            126H
EXTCHR          DB      '^'-40H ;^^ = Send next character               127H
;
;
       RS      3                       ;                               128H
;
IN@MODCTL1:
       JMP     IMCTL1                  ;in modem control port          12BH
       DB      0,0,0,0,0,0,0           ; spares
;
OUT@MODDATP:
       JMP     OMDP                    ;out modem data port            135H
       DB      0,0,0,0,0,0,0           ; spares
;
IN@MODDATP:
       JMP     IMDP                    ;in modem data port             13FH
       DB      0,0,0,0,0,0,0           ; spares
;
ANI@MODRCVB:    AND AL,DAV              ;bit to test for receive ready  149H
               RET
;
CPI@MODRCVR:    CMP AL,DAV              ;value of rcv. bit when ready   14CH
               RET
;
ANI@MODSNDB:    AND AL,TBMT             ;bit to test for send ready     14FH
               RET
;
CPI@MODSNDR:    CMP AL,TBMT             ;value of send bit when ready   152H
               RET
;
       RS      6                       ;                               156H
;
OUT@MODCTL1:    RET
       RS      2                       ;out modem control port #2      15BH
;
OUT@MODCTL2:    RET
       RS      2                       ;out modem control port #1      15EH
;
LOGONPTR DW     (Offset LOGON)          ;for user message.              161H
       RS      6                       ;                               163H
JMP@GOODBYE:JMP GOODBYE                 ;                               169H
JMP@INITMOD:JMP INITMOD                 ;go to user written routine     16CH
       RET
       NOP                             ;(by-passes PMMI routine)       170H
       NOP
       RET
       NOP                             ;(by-passes PMMI routine)       173H
       NOP
       RET
       NOP                             ;(by-passes PMMI routine)       176H
       NOP
JMP@SETUPR:    JMP  SETUPR              ;                               178H
JMP@SPCLMENU:  JMP  SPCLMENU            ;                               17BH
JMP@SYSVER:    JMPS SYSVER              ;make sure this is SHORT Jump   17EH
JMP@BREAK:     JMP  SENDBRK             ;                               180H

;
; Do not change the following eight lines.
;
JMP@ILPRT:
               RS      3               ;                               183H
JMP@INBUF:
               RS      3               ;                               186H
JMP@INLNCOMP:
               RS      3               ;                               189H
JMP@INMODEM:
               RS      3               ;                               18CH
JMP@NXTSCRN:
               RS      3               ;                               18FH
JMP@TIMER:
               RS      3               ;                               192H
JMP@CTYPE:
               RS      3               ;                               195H
JMP@KEYIN:
               RS      3               ;                               198H
;
;
; Routine to clear to end of screen.  If using CLREOS and CLRSCRN, set
; SCRNTEST to YES at 010AH (above).
;
CLREOS: CALL    JMP@ILPRT               ;                               19BH
       DB      ESC,'Y',0,0,0           ;                               19EH
       RET                             ;                               1A3H
;
CLRSCRN:CALL    JMP@ILPRT               ;                               1A4H
       DB      ESC,'*',0,0,0           ;                               1A7H
       RET                             ;                               1ACH
;
SYSVER: CALL    JMP@ILPRT               ;                               1ADH
       DB      'Version for CompuPro '
       DB      'Interfacer-3 or 4 (port ',MDM+'0',')'
       DB      CR,LF,0
       RET
;.....
;
;
;-----------------------------------------------------------------------
;
; NOTE:  You can change the SYSVER message to be longer or shorter.  The
;        end of your last routine should terminate by 0600H if using the
;        Hayes Smartmodem or by address 0C00H otherwise.
;
;-----------------------------------------------------------------------
;
; You can put in a message at this location which can be called up with
; CTL-O if TRANLOGON has been set TRUE.  You can use several lines if
; desired.  End with a 0.
;
LOGON   DB      'It has been a long day, so now it'
       DB      ' is time for a Coke!',CR,LF,0
;.....
;
;
; Add your own routine here to read a byte from your Modem Control port
;
IMCTL1: MOV     AL,MDM          ;select Interfacer 3/4 Port
       OUT     UPORT,AL
       IN      AL,SPORT
       RET
;....
;
;
; Add your own routine here to send a byte in AL to modem data port
;
OMDP:   PUSH    AX              ;save data while selecting port
       MOV     AL,MDM
       OUT     UPORT,AL
       POP     AX
       OUT     DPORT,AL
       RET
;....
;
;
; Add your own routine here to read modem data port into AL
;
IMDP:   MOV     AL,MDM          ;select UART first
       OUT     UPORT,AL
       IN      AL,DPORT        ;now get data
       RET
;.....
;
;
; Add your own routine here to send a break tone to reset some time-
; share computers, if desired.
;
SENDBRK:MOV     AL,MDM          ;select chip
       OUT     UPORT,AL
       MOV     AL,2FH          ;send break for 300ms
       JMPS    GOODBYE1
;.....
;
;
; Add your own routine here to put DTR low and/or send a break tone.
; Check other routines such as MDM711DP.ASM which is using this feature.
;
GOODBYE:MOV     AL,MDM          ;select chip
       OUT     UPORT,AL
       XOR     AL,AL           ;turn off DTR
;
GOODBYE1:
       OUT     CPORT,AL
       MOV     CH,3            ;turn off DTR for 300 ms.
       CALL    JMP@TIMER
       MOV     AL,27H          ;turn DTR back on
       OUT     CPORT,AL
       RET
;.....
;
;
; You can use this area for any special initialization or setup you may
; wish to include.  Each must stop with a RET.  You can check the other
; available overlays for ideas how to write your own routines if that
; may be of some help.
;
INITMOD:MOV     AL,MDM          ;select chip
       OUT     UPORT,AL
;
INITMOD1:
       MOV     AL,4EH          ;select 8 data bits, no parity, 1 stop
       OUT     MPORT,AL
;
INITMOD2:
       MOV     BL,Byte Ptr MSPEED  ;get baud rate
       DEC     BL              ; adjust for table offset
       XOR     BH,BH           ; make 16 bit
       MOV     AL, Byte Ptr BDTBL[BX]
       OUT     MPORT,AL
       MOV     AL,27H          ;turn on DTR etc.
       OUT     CPORT,AL
       RET
;.....
;
;
; Use the 'SET' command to select a desired baud rate
;
SETUPR: MOV     DX,(Offset BAUDBUF)  ;point to new input buffer
       CALL    JMP@ILPRT
       DB      'Input Baud Rate (300, 600, 1200, 4800, 9600, 19200): ',0
       CALL    JMP@INBUF
       MOV     DX,(Offset BAUDBUF)+2
       CALL    JMP@INLNCOMP    ;compare BAUDBUF+2 with characters below
       DB      '300',0
       JNB     OK300           ;go if got match
       CALL    JMP@INLNCOMP
       DB      '600',0
       JNB     OK600
       CALL    JMP@INLNCOMP
       DB      '1200',0
       JNB     OK1200
       CALL    JMP@INLNCOMP
       DB      '4800',0
       JNB     OK4800
       CALL    JMP@INLNCOMP
       DB      '9600',0
       JNB     OK9600
       CALL    JMP@INLNCOMP
       DB      '19200',0
       JNB     OK19200
       CALL    JMP@ILPRT       ;all matches failed, tell operator
       DB      '++ Incorrect entry ++',CR,LF,BELL,0
       JMP     SETUPR                  ;try again
;
OK300:  MOV     AL,1            ;MSPEED 300 baud value
       JMPS    LOADBD          ;go load everything
;
OK600:  MOV     AL,3
       JMPS    LOADBD
;
OK1200: MOV     AL,5
       JMPS    LOADBD
;
OK4800: MOV     AL,7
       JMPS    LOADBD
;
OK9600: MOV     AL,8
       JMPS    LOADBD
;
OK19200:MOV     AL,9
;
LOADBD: MOV     Byte Ptr MSPEED,AL  ;change time-to-send to match baudrate
       JMP     INITMOD         ;reinitialize to new baudrate, then done
;...
;
;
BDRTE   DB      0               ;keeps selected uart Baud Rate Value
;.....
;
;
; Table of baudrate parameters
;
BD300   EQU     35H             ;300  bps
BD450   EQU     0               ;450  bps NOT SUPPORTED
BD600   EQU     36H             ;600  bps
BD710   EQU     0               ;710  bps NOT SUPPORTED
BD1200  EQU     37H             ;1200 bps
BD2400  EQU     0               ;2400 bps NOT SUPPORTED
BD4800  EQU     3CH             ;4800 bps
BD9600  EQU     3EH             ;9600 bps
BD19200 EQU     3FH             ;19200 bps
;
BAUDBUF DB      10,0
       RS      10

BDTBL   DB BD300,BD450,BD600,BD710,BD1200,BD2400,BD4800,BD9600,BD19200
;....
;
;              (END OF INITMOD AND SETUP ROUTINES)
;=======================================================================
;
;
; If using the Hayes Smartmodem this is unavailable without a special
; change.
;
SPCLMENU:RET
;
;
; NOTE:  MUST TERMINATE PRIOR TO 0600H (with Smartmodem)
;                                0C00H (without Smartmodem)
;.....
;
       END