TITLE 'ZENITH 100 OVLY'
; M8HZ.A86 -- Zenith 100 overlay file for MDM8xx.       09/28/84
;
; This overlay adapts the MDM8xx program to the 2661 EPCI  serial I/O
; chip used in the Zenith 100 series.
;
; You will want to look this file over carefully. There are a number of
; options that you can use to configure the program to suit your taste.
;
; Edit this file for your preferences then follow the "TO USE:" example
; shown below.
;
;       TO USE: First edit this file to chose your options.
;               Then assemble with ASM86.CMD or equivalent
;               assembler.  Then use M8CNFG to overlay the
;               the results of this program to the original
;               MDM8xx.H86 file:
;
;                       ASM86 M8HZ-1
;                       REN M8OVL.H86=M8HZ-1.H86
;                       M8CNFG
;                       GENCMD MDM 8080 CODE[MFF0]
;
;                Now run MDM.  Have Fun
;
; =   =   =   =   =   =   =   =   =   =   =   =   =   =   =   =   =   =
;
; 09/28/84 - Modified GP overlay for Z100       - Dennis Vallianos
; 09/21/84 - Converted for use with MDM830      - Alex Soya
; 01/10/83 - Original version for MDM701        - Irv Hoff
;
; =   =   =   =   =   =   =   =   =   =   =   =   =   =   =   =   =
;
YES             EQU     0FFH
NO              EQU     0
;
;
BELL            EQU     07H     ;bell
CR              EQU     0DH     ;carriage return
ESC             EQU     1BH     ;escape
LF              EQU     0AH     ;linefeed
;
;
; Zenith 100 specific communications port data
;
MODDATP         EQU     0ECH    ;modem data in port
MODCTL1         EQU     0EDH    ;modem control port
MODCTL2         EQU     0EDH    ;modem control port
MODMODE         EQU     0EEH    ;modem mode port
MODCMD          EQU     0EFH    ;modem command port
;
MODRCVB         EQU     2       ;bit to test for receive
MODRCVR         EQU     2       ;value when ready
MODSNDB         EQU     1       ;bit to test for send
MODSNDR         EQU     1       ;value when ready
;
               ORG     100H
               RS      3       ;(for  "JMP   START" instruction)
;
; User options.
; Change the clock speed to suit your system (defaults to 1200 baud).
;
;
PMMIMODEM       DB      NO      ;yes=PMMI S-100 Modem                   103H
AUTODIAL        DB      NO      ;yes=HAYES-likem no=non-PMMI            104H
TOUCHPULSE      DB      'T'     ;T=touch, P=pulse (Smartmodem-only)     105H
CLOCK           DB      49      ;clock speed in MHz x10, 25.5 MHz max.  106H
                               ;20=2 MHh, 37=3.68 MHz, 40=4 MHz, etc.
MSPEED          DB      5       ;0=110 1=300 2=450 3=600 4=710 5=1200   107H
                               ;6=2400 7=4800 8=9600 9=19200 default
BYTDLY          DB      5       ;0=0 delay  1=10ms  5=50 ms - 9=90 ms   108H
                               ;default time to send character in ter-
                               ;minal mode file transfer for slow BBS.
CRDLY           DB      5       ;0=0 delay 1=100 ms 5=500 ms - 9=900 ms 109H
                               ;default time for extra wait after CRLF
                               ;in terminal mode file transfer
NOOFCOL         DB      5       ;number of DIR columns shown            10AH
SETUPTST        DB      YES     ;yes=user-added Setup routine           10BH
SCRNTEST        DB      YES     ;cursor control routine                 10CH
RETRY           DB      NO      ;yes=reset the error limit to try again 10DH
                               ;no=abort after 10 consecutive errors
BAKUPBYTE       DB      NO      ;yes=change any file same name to .BAK  10EH
CRCDFLT         DB      YES     ;yes=default to CRC checking            10FH
TOGGLECRC       DB      YES     ;yes=allow toggling of CRC to Checksum  110H
CONVRUB         DB      NO      ;yes=convert rub to backspace           111H
TOGGLELRUB      DB      YES     ;yes=allow toggling of rub to backspace 112H
ADDLF           DB      NO      ;no=no LF after CR to send file in      113H
                               ;terminal mode (added by remote echo)
TOGGLELF        DB      YES     ;yes=allow toggling of LF after CR      114H
TRANLOGON       DB      YES     ;yes=allow transmission of logon        115H
                               ;write logon sequence at location LOGON
RESERVED        DB      NO      ;resevered for future release           116H
LOCONEXTCHR     DB      NO      ;yes=local command if EXTCHR precedes   117H
                               ;no=external command if EXTCHR precedes
TOGGLELOC       DB      YES     ;yes=allow toggling of LOCONEXTCHR      118H
LSTTST          DB      YES     ;yes=printer available on printer port  119H
XOFFTST         DB      NO      ;yes=checks for XOFF from remote while  11AH
                               ;sending a file in terminal mode
XONWAIT         DB      NO      ;yes=wait for XON after CR while        11BH
                               ;sending a file in terminal mode
TOGXOFF         DB      YES     ;yes=allow toggling of XOFF checking    11CH
IGNORCTL        DB      YES     ;yes=CTL-chars above ^M not displayed   11DH
EXTRA1          DB      0       ;for future expansion                   11EH
EXITCHR         DB      'E'-40H ;^E = Exit to main menu                 11FH
BRKCHR          DB      'B'-40H ;^B = Send 300 ms. break tone           120H
NOCONNCT        DB      'N'-40H ;^N = Disconnect from the phone line    121H
LOGCHR          DB      'L'-40H ;^L = Send logon                        122H
LSTCHR          DB      'P'-40H ;^P = Toggle printer                    123H
UNSAVE          DB      'R'-40H ;^R = Close input text buffer           124H
TRANCHR         DB      'T'-40H ;^T = Transmit file to remote           125H
SAVECHR         DB      'Y'-40H ;^Y = Open input text buffer            126H
EXTCHR          DB      '\'-40H ;^\ = Send next character               127H
;
;
;
               RS      3               ;                               128H
;
IN_MODCTL1:     IN     AL,MODCTL1 ! RET ;in modem control port          12BH
               DB     0,0,0,0,0,0,0    ; spares
;
OUT_MODDATP:    OUT    MODDATP,AL ! RET ;out modem data port            135H
               DB     0,0,0,0,0,0,0    ; spares
;
IN_MODDATP:     IN     AL,MODDATP ! RET ;in modem data port             13FH
               DB     0,0,0,0,0,0,0    ; spares
;
ANI_MODRCVB:    AND    AL,MODRCVB ! RET ;bit to test for receive ready  149H
;
CPI_MODRCVR:    CMP    AL,MODRCVR ! RET ;value of rcv. bit when ready   14CH
;
ANI_MODSNDB:    AND    AL,MODSNDB ! RET ;bit to test for send ready     14FH

CPI_MODSNDR:    CMP    AL,MODSNDR ! RET ;value of send bit when ready   152H
;
               RS     6                ;                               156H
;
OUT_MODCTL1:    OUT    MODCTL1,AL ! RET ;out modem control port #2      15BH
;
OUT_MODCTL2:    OUT    MODCTL2,AL ! RET ;out modem control port #1      15EH




;
;
LOGONPTR        DW      (OFFSET LOGON)  ;for user message.              161H
               RS      6               ;                               163H
JMP_GOODBYE:    JMP GOODBYE             ;                               169H
JMP_INITMOD:    JMP INITMOD             ;go to user written routine     16CH
               RET
               NOP                     ;(by-passes PMMI routine)       170H
               NOP
               RET
               NOP                     ;(by-passes PMMI routine)       173H
               NOP
               RET
               NOP                     ;(by-passes PMMI routine)       176H
               NOP
;
JMP_SETUPR:     JMP  SETUPR             ;                               178H
JMP_SPCLMENU:   JMP  SPCLMENU           ;                               17BH
JMP_SYSVER:     JMPS  SYSVER            ;make sure this is SHORT Jump   17EH
JMP_BREAK:      JMP  SENDBRK            ;                               180H

;
; Do not change the following sixteen lines.
;
JMP_ILPRT:
               RS      3               ;                               183H
JMP_INBUF:
               RS      3               ;                               186H
JMP_INLNCOMP:
               RS      3               ;                               189H
JMP_INMODEM:
               RS      3               ;                               18CH
JMP_NXTSCRN:
               RS      3               ;                               18FH
JMP_TIMER:
               RS      3               ;                               192H
JMP_CTYPE:
               RS      3               ;                               195H
JMP_KEYIN:
               RS      3               ;                               198H
;
;
; Routine to clear to end of screen.  If using CLREOS and CLRSCRN, set
; SCRNTEST to YES at 010AH (above).
;
CLREOS: CALL    JMP_ILPRT               ;                               19BH
       DB      ESC,'J',0,0,0           ;                               19EH
       RET                             ;                               1A3H
;
CLRSCRN:CALL    JMP_ILPRT               ;                               1A4H
       DB      ESC,'E',0,0,0           ;                               1A7H
       RET                             ;                               1ACH
;
SYSVER: CALL    JMP_ILPRT               ;                               1ADH
       DB      'Version for Zenith 100 modem port J2'
       DB      CR,LF,0
       RET
;.....
;
;
;-----------------------------------------------------------------------
;
; NOTE:  You can change the SYSVER message to be longer or shorter.  The
;        end of your last routine should terminate by 0600H if using the
;        Hayes Smartmodem or by address 0C00H otherwise.
;
;-----------------------------------------------------------------------
;
; You can put in a message at this location which can be called up with
; CTL-O if TRANLOGON has been set TRUE.  You can use several lines if
; desired.  End with a 0.
;
LOGON   DB      'Hello out there!',CR,LF,0

;.....
;
;
; Send a break tone to reset some time-share computers, if desired.
;
SENDBRK:MOV     AL,1DH
       JMP     GOODBYE1
;.....
;
;
; Routine here to put DTR low and disconnect modem.
;
GOODBYE:MOV     AL,0                    ;selecting chip forces DTR low
;
GOODBYE1:
       OUT     MODCMD,AL
       IN      AL,MODCMD
       IN      AL,MODCMD
       MOV     CH,3                    ;hold for 300 ms
       CALL    JMP_TIMER
       MOV     AL,37H                  ;reset to normal
       OUT     MODCMD,AL
       IN      AL,MODCMD
       IN      AL,MODCMD
       MOV     AL,0
       RET
;.....
;
;
; The following routine initializes the 2661B I/O port.
;
INITMOD:MOV     AL,0                    ;select chip
       OUT     MODCMD,AL
       IN      AL,MODCMD
       IN      AL,MODCMD
       MOV     AL,4EH                  ;async., 8 bits, 1 stop, no parity
       OUT     MODMODE,AL
       MOV     BL,BYTE PTR MSPEED      ;get baud rate
       DEC     BL                      ;adjust for table offset
       XOR     BH,BH                   ;make 16 bit
       MOV     AL,BYTE PTR BDTBL[BX]
       OUT     MODMODE,AL              ;set baud rate
       MOV     AL,37H                  ;async, RTS, DTR, etc.
       OUT     MODCMD,AL
       IN      AL,MODCMD
       IN      AL,MODCMD
       MOV     AL,0                    ;clear register
       RET
;.....
;
; Use the 'SET' command to select a desired baud rate.
;
SETUPR: MOV     DX,OFFSET BAUDBUF
       CALL    JMP_ILPRT
       DB      'Input Baud Rate (300, 1200, 2400, 4800, 9600): ',0
       CALL    JMP_INBUF               ;get user's input
       MOV     DX,(OFFSET BAUDBUF)+2
       CALL    JMP_INLNCOMP            ;compare BAUDBUF+2 with chars. below
       DB      '300',0
       JNB     OK300
       CALL    JMP_INLNCOMP
       DB      '1200',0
       JNB     OK1200
       CALL    JMP_INLNCOMP
       DB      '2400',0
       JNB     OK2400
       CALL    JMP_INLNCOMP
       DB      '4800',0
       JNB     OK4800
       CALL    JMP_INLNCOMP
       DB      '9600',0
       JNB     OK9600
       CALL    JMP_ILPRT               ;failed to match - tell operator
       DB      '++ Incorrect entry ++',CR,LF,BELL,0
       JMP     SETUPR                  ;try again
;
OK300:  MOV     AL,1
       JMPS    LOADBD
;
OK1200: MOV     AL,5
       JMPS    LOADBD
;
OK2400: MOV     AL,6
       JMPS    LOADBD
;
OK4800: MOV     AL,7
       JMPS    LOADBD
;
OK9600: MOV     AL,8
       JMPS    LOADBD
;
OK19200:
       MOV     AL,9
;
LOADBD: MOV     BYTE PTR MSPEED,AL      ;change so messages are ok
       JMP     INITMOD                 ;reinitialize chip to new speed
;
; TABLE OF BAUDRATE PARAMETERS
;
BD300   EQU     0F6H
BD450   EQU     0                       ;450 bps NOT SUPPORTED
BD600   EQU     0                       ;600 bps NOT SUPPORTED
BD710   EQU     0                       ;710 bps NOT SUPPORTED
BD1200  EQU     0F8H
BD2400  EQU     0FBH
BD4800  EQU     0FCH
BD9600  EQU     0FDH
BD19200 EQU     0FEH
;
BAUDBUF DB      10,0
       RS      10
;
; Pointer table
;
BDTBL   DB      BD300,BD450,BD600,BD710,BD1200,BD2400,BD4800,BD9600,BD19200
;
;
; If using the Hayes Smartmodem this is unavailable without a special
; change.
;
SPCLMENU:
       RET
;
;
; NOTE:  MUST TERMINATE PRIOR TO 0600H (with Smartmodem)
;                                0C00H (without Smartmodem)
;.....
;
         END