BYE510.FX2                                      08/26/86

Fix number two for BYE510.

1.)     For persons who desire to run RBBS as their .COM file (both
       COMFILE and RBBS set to YES) and with EXFILE also set to YES,
       you will find that BYE will not cycle properly for the next
       caller.  To correct this problem, near the end of the main
       .ASM file you will find several conditional equates such as

                IF     EXFILE AND METAL

       DB statements here of user area, filename, and 21 nuls

                ENDIF

       just add a conditional of the equivilent to

                IF     EXFILE AND RBBS

       replacing the filename with that of your own exit file,
       or if NO exit file AND you are running CP/M PLUS (CPM3 set
       to YES) then use the filename of 'BYE     COM'.

                ENDIF          ;EXFILE AND RBBS

2.)     If you are using a BANKED CP/M PLUS system, you may still
       utilize your own MDPREP/MDPOSP routines by reinstallation
       of the calls to them in the main program.  The CALL MDPREP
       would be installed in the PATCH: area just before the
       CALL TBLADDR, and the CALL MDPOSP would be installed in
       the EXCPM: area just before the CALL RSXCLR.

       MOST of the CP/M Plus systems no longer need the pre- or
       post-processing routines.  The Morrow HARD DISK SYSTEMS
       are an exception to this, so, Morrow users, keep this in
       mind for future versions, just in case the MDPREP/MDPOSP
       calls remain out.  (We should be able to remember this!)


It's looking great guys!
       THANKS!!!
                                       George Reding
                                       CompuServe [72436,45]