\"      $NetBSD: sdpquery.1,v 1.17 2014/03/18 18:20:45 riastradh Exp $
\"
\" Copyright (c) 2006 Itronix Inc.
\" All rights reserved.
\"
\" Redistribution and use in source and binary forms, with or without
\" modification, are permitted provided that the following conditions
\" are met:
\" 1. Redistributions of source code must retain the above copyright
\"    notice, this list of conditions and the following disclaimer.
\" 2. Redistributions in binary form must reproduce the above copyright
\"    notice, this list of conditions and the following disclaimer in the
\"    documentation and/or other materials provided with the distribution.
\" 3. The name of Itronix Inc. may not be used to endorse
\"    or promote products derived from this software without specific
\"    prior written permission.
\"
\" THIS SOFTWARE IS PROVIDED BY ITRONIX INC. ``AS IS'' AND
\" ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED
\" TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
\" PURPOSE ARE DISCLAIMED.  IN NO EVENT SHALL ITRONIX INC. BE LIABLE FOR ANY
\" DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES
\" (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
\" LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND
\" ON ANY THEORY OF LIABILITY, WHETHER IN
\" CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
\" ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
\" POSSIBILITY OF SUCH DAMAGE.
\"
\" Copyright (c) 2009 The NetBSD Foundation, Inc.
\" Copyright (c) 2003 Maksim Yevmenkin <[email protected]>
\" All rights reserved.
\"
\" Redistribution and use in source and binary forms, with or without
\" modification, are permitted provided that the following conditions
\" are met:
\" 1. Redistributions of source code must retain the above copyright
\"    notice, this list of conditions and the following disclaimer.
\" 2. Redistributions in binary form must reproduce the above copyright
\"    notice, this list of conditions and the following disclaimer in the
\"    documentation and/or other materials provided with the distribution.
\"
\" THIS SOFTWARE IS PROVIDED BY THE AUTHOR AND CONTRIBUTORS ``AS IS'' AND
\" ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
\" ARE DISCLAIMED. IN NO EVENT SHALL THE AUTHOR OR CONTRIBUTORS BE LIABLE
\" FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
\" DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
\" OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
\" LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
\" SUCH DAMAGE.
\"
\" $FreeBSD: src/usr.sbin/bluetooth/sdpcontrol/sdpcontrol.8,v 1.6 2005/07/09 19:04:43 markus Exp $
\"
Dd October 6, 2009
Dt SDPQUERY 1
Os
Sh NAME
Nm sdpquery
Nd Service Discovery Protocol query utility
Sh SYNOPSIS
Nm
Op Fl NRX
Op Fl d Ar device
Fl a Ar address
Ar command
Op Ar parameters ...
Nm
Op Fl NRX
Op Fl c Ar path
Fl l
Ar command
Op Ar parameters ...
Sh DESCRIPTION
The
Nm
utility attempts to query the specified Service Discovery Protocol
(SDP) server.
Remote SDP servers are identified by their address.
Connection to the local SDP server is made via the control socket.
The
Nm
utility retrieves complete Service Records as directed and prints
each record's attribute ID/value list to standard output and error
messages to standard error.
Pp
The options are as follows:
Bl -tag -width ".Fl a Ar address"
It Fl a Ar address
Connect to the remote device with the specified address.
The address can be specified as BD_ADDR or a name.
If a name was specified, the
Nm
utility attempts to resolve the name via
Xr bt_gethostbyname 3 .
If no remote address is given,
Nm
attempts to contact a local SDP server via the control socket.
It Fl c Ar path
Specify path to the control socket.
The default path is
Pa /var/run/sdp .
It Fl d Ar device
Connect from the local device with the specified address.
The device can be specified by BD_ADDR or device name.
See
Xr btconfig 8
for a list of devices available.
If no device is specified, the
Nm
utility will use the best available.
It Fl l
Query the local SDP server via the control socket.
It Fl N
Additionally display numerical values.
It Fl R
Display service attributes in raw (uninterpreted) format.
It Fl X
Display service attribute values in hex.
El
Pp
The currently supported commands in
Nm
are:
Pp
Bl -tag -width Browse -compact
It Cm Browse Op Ar group
Browse for services.
The
Ar group
parameter is the UUID of the group to browse.
If omitted, the "Public Browse Group" is used.
Pp
It Cm Record Ar handle Op Ar handle...
Retrieve the Service Record with the given
Ar handle .
Multiple handles can be given.
Pp
It Cm Search Ar uuid Op Ar uuid...
Search for records matching the list of
UUIDs which can be given in numerical form, or the
following aliases are known:
Pp
Bl -tag -offset indent -compact -width RFCOMMxxx
It A2DP
Advanced Audio Distribution Profile
It BNEP
Bluetooth Network Encapsulation Protocol
It CIP
Common ISDN Access Service
It CTP
Cordless Telephony Service
It DUN
Dialup Networking Service
It FAX
Fax Service
It FTRN
File Transfer Service
It GN
Group ad-hoc Network Service
It HID
Human Interface Device Service
It HF
Handsfree Service
It HSET
Headset Service
It L2CAP
Logical Link Control and Adaptation Protocol
It LAN
LAN Access Using PPP Service
It NAP
Network Access Point Service
It OBEX
Object Exchange Protocol
It OPUSH
Object Push Service
It PANU
Personal Area Networking User Service
It PNP
Plug'n'Play Information Service
It RFCOMM
RFCOMM Protocol
It SDP
Service Discovery Protocol
It SP
Serial Port Service
It SYNC
IrMC Sync Client Service
El
Pp
Note that in order for a record to match, it must contain all the
UUIDs in the ServiceSearchPattern and the maximum number is 12.
El
Sh EXIT STATUS
Ex -std
Sh SEE ALSO
Xr bluetooth 3 ,
Xr sdp 3 ,
Xr btconfig 8 ,
Xr sdpd 8
Sh HISTORY
The
Nm
command first appeared in
Fx 5.3
as
Nm sdpcontrol .
It was ported to
Nx 4.0
under its present name by
An Iain Hibbert
under the sponsorship of Itronix, Inc.
Sh AUTHORS
An Maksim Yevmenkin Aq Mt [email protected]
An Iain Hibbert
for Itronix, Inc.