Subj : Re: Sio vs Sio2k
To   : Mike Luther
From : Kevin Nunn
Date : Sun Apr 10 2005 06:53 pm

-=> MIKE LUTHER wrote to KEVIN NUNN <=-

ML> I'm wondering if your modem and the SIO 1.60 are curiously in conflict
ML> over the DOS session settings should you be running the BBS in DOS

Thanks for the help! :) The BBS is OS/2 native, as with the Mailer
(BT). I do have dos doors, but the problem occurs even before trying to
get into dos.

ML> mode?  That or possibly that the modem has an initialization
setting ML> for one of its parameters that is in conflict?  Is it, for
example,

Not sure what all might help you, but I'll start with the modem info
and init strings:

==========================================
ati7
USRobotics Courier V.Everything Configuration Profile...

Product type           US/Canada External
Options                HST,V32bis,Terbo,VFC,V34+
Fax Options            Class 1,Class 2.0
Clock Freq             20.16Mhz
Flash ROM              512k
Ram                    64k

Supervisor date        03/13/98
DSP date               03/13/98

Supervisor rev         7.3.14
DSP rev                3.0.13

Serial Number          20XOB9N6F66A

OK

==========================================
One note about the modem, I currently use a courier, but I have
switched to a USR sportster and the problem still occurs

=========================================

ati4
USRobotics Courier V.Everything Settings...

  B0  C1  E1  F1  M1  Q0  V1  X7
  BAUD=115200 PARITY=N  WORDLEN=8
  DIAL=PULSE  ON HOOK   TIMER

  &A3  &B1  &C1  &D2  &G0  &H1  &I0  &K1  &L0  &M4  &N0
  &P0  &R2  &S0  &T5  &U0  &X0  &Y1  %N6  #CID=0

  S00=000  S01=000  S02=043  S03=013  S04=010  S05=008  S06=002  S07=060
  S08=002  S09=006  S10=014  S11=070  S12=050  S13=000  S14=001  S15=000
  S16=000  S17=000  S18=000  S19=000  S20=000  S21=010  S22=017  S23=019
  S24=150  S25=005  S26=001  S27=000  S28=008  S29=020  S30=000  S31=000
  S32=009  S33=000  S34=000  S35=000  S36=000  S37=000  S38=000  S39=000
  S40=000  S41=000  S42=126  S43=200  S44=015  S45=000  S46=000  S47=000
  S48=000  S49=000  S50=000  S51=000  S52=000  S53=000  S54=064  S55=000
  S56=000  S57=000  S58=000  S59=000  S60=000  S61=000  S62=000  S63=000
  S64=000  S65=000  S66=000  S67=000  S68=000  S69=000  S70=000

  LAST DIALED #:

=================================================

And lastly, my modem strings from binkley.cfg - these are directly from
the BGFAX documentation for a USR

PreInit    |v``^``ATZ|~ATS0=0+FCLASS=2\.0|~
Init       AT+FAA=1;+FLI="713\ 555\ 1212";+FNR=1,1,1,1|
PreDial    `
Prefix     ATM0+FCLASS=0;DT
Answer     ATA|

=================================================

SIO setup in the config.sys file is generic, posting just in case

DEVICE=C:\SIO\SIO.SYS (COM1,3F8,4,-) (COM2:115200,INTERNET:2F8,NONE:3,-)
(COM3:115200,INTERNET:3E8,NONE:4,-) (COM4:115200,INTERNET:2E8,NONE:3,-)
DEVICE=C:\SIO\VSIO.SYS
DEVICE=C:\SIO\vx00.sys

==================================================

If there is anymore info that I can provide, let me know and thanks for
helping me try to figure this out.

Kev

... *    <- Tribble   #    <- Tribble After Borg Assimilation
--- Telegard/2/QWK v3.09.g2-sp4/mL
* Origin: Razor's Domain BBS (1:397/10)