Subj : Talsiman/Postie
To : vorlon
From : deon
Date : Sun Apr 17 2022 08:28 pm
Re: Talsiman/Postie
By: vorlon to deon on Sun Apr 17 2022 05:37 pm
> >> talsiman/postie end.
> >> 2022-04-14 14:36:55 [1893] ERROR: Packet version != 2
> >> Hub is husky.
> >> A 14:36:15 Invalid pkt version 512!
> > An endian issue?
> The intresting thing is that hpt on the same machine works, but it can't
> read the squish files.
>
> Hpt on the same machine, can read & process JAM files though...
So that sounds even more like an endian issue.
I'm assuming you compiled hpt and talisman on the m68k? I bet the hpt on the same machine sending something to a different machine wouldnt work... You'd get the same pkt version issue... (Send me a packet and we can see...)
"512" is the 2nd bit of the 2nd byte, and "2" is the 2nd bit of the 1st byte, and in a fido packet, the "version" value is a 2 byte field.
...����
--- SBBSecho 3.15-Linux
* Origin: I'm playing with ANSI+videotex - wanna play too? (21:2/116)