On 24 Jun 21 23:17, Jesse C---- said the following to All:
JC> issue has come up now when I start dbridge it immedatly sees some sort of
JC> caller and aborting the operation says aborting opperation however it launc
JC> the board anyways then after you hangup dbridge swapps back in and still sa
JC> aborting opperation and hangs there. timer runs still but program is stuck.
Is the CD indicator "grey" on the modem status bar when D'Bridge starts up?
If it is, then either the Fossil driver you're using or the modem-control
file is forcing the carrier-detect (CD) signal on or high, which is how the
mailer determines a connection is established. Either make sure &C1 is part of
the modem-init string in the modem control file or check the Fossil settings.
Nick
--- Renegade vY2Ka2
* Origin: Joey, do you like movies about gladiators? (1:229/426)