Nom,Longitude,Latitude,ReservoirName/Nom,Year/Année,River/Rivière,City/Ville,Type/Type,High dam/Haut en m,Length/Long m,Vol/Vol 10³ m³,Capacit, 10³ m³,Area/ Surface  10³ m²,Owner/Proprié.,Consultant/Bur.d'études,Contractor/Entr,Note/Note,Altitude (m)
BARKERS CREEK,144.278045654,-36.968818665,,1869,Barkers Creek,CASTLEMAINE,TE,14,685,,2240,540,Coliban Water,,,,364 [e]
BATTERY CREEK,146.119171143,-38.715976715,BATTERY CREEK,1962,Battery Creek,FISH CREEK,TE,15,66,22,119,20,South Gippsland Water,Fisher Stewart Pty Ltd,Sydenham Bros,Dam raised 1976,121 [e]
BEACONSFIELD,145.409396000,-38.029434000,BEACONSFIELD RESERVOIR,1918,Haunted Gully Ck,MELBOURNE,TE,24,174,,912,146,Melbourne Water Corporation,State Rivers & Water Supply, Commission, Victoria ,State Rivers & Water Supply, Commission, Victoria ,Concrete core wall with puddle clay each side. No longer used for water supply,102 [e]
BELLFIELD,142.543681000,-37.174594000,LAKE BELLFIELD,1966,Fyans Creek,STAWELL,ER,55,750,2086,78550,4800,Wimmera Mallee Water,State Rivers & Water Supply Commission, Victoria,State Rivers & Water Supply Commission, Victoria,,266 [e]
BLUE ROCK,146.227942000,-38.079379000,LAKE BLUE ROCK,1984,Tanjil,MOE,ER,72,600,1514,200000,8730,Southern Rural Water,Rural Water Commission, Victoria,Rural Water Commission, Citra, White Industries,,137 [e]
BOSTOCK,144.186019000,-37.606752000,,1954,E Moorabool,BALLAN,ER/TE,27,271,150,7500,850,Barwon Water,Geelong Waterworks & Sewerage Trust ,Thiess Brothers,Includes secondary embankment 5m high and 340m long,494 [e]
BUFFALO,146.661794000,-36.715254000,LAKE BUFFALO,1965,Buffalo,WANGARATTA,ER,31,639,260,24000,3410,Goulburn-Murray Water,State Rivers & Water Supply Commission, Victoria ,State Rivers & Water Supply Commission, Victoria ,,266 [e]
BUNGAL,144.074128000,-37.677724000,,1972,West Moorabool,BALLARAT,ER,49,296,567,59600,3560,Central Highlands Water,Gutteridge Haskins & Davey,Roche Bros Pty Ltd,,401 [e]
CAIRN CURRAN,143.967097000,-36.989202000,CAIRN CURRAN,1956,Loddon,MALDON,TE,44,1548,811,148000,19000,Goulburn-Murray Water,State Rivers & Water Supply Commission, Victoria ,Utah (Aust) Ltd,Includes secondary embankment 15 m high & 853 m long,203 [e]
CAMPASPE WEIR,144.660644531,-36.435855866,,1892,Campaspe,ELMORE,ER/PG,13,140,,2700,1050,Goulburn-Murray Water,Victorian Water Supply Department ,Victorian Water Supply Department ,,122 [e]
CANDOWIE,145.571809000,-38.457235000,,1963,Tennants Creek,BASS,TE/ER,17,160,41,2263,550,Westernport Water,C W Candy & Partners (original), John Scroggie (modifications),McDonald Construction and Thiess,In 1978, spillway raised 1.68m and parapet wall 1.7m. In 1982, spillway raised 0.80m.,59 [e]
CARDINIA,145.398216000,-37.970422000,CARDINIA RESERVOIR,1973,Cardinia Creek,MELBOURNE,ER,86,1542,5150,286910,12950,Melbourne Water Corporation,Snowy Mountains Engineering Corporation,Fluor Construction for MMBW,Volume quantity includes 4 Saddle Dams, Main Dam 3700 only crest length 4295 without Saddle Dams,157 [e]
CARDINIA DIVERSION 1,145.386704000,-37.936929000,AURA VALE LAKE,1973,Trib Cardinia Creek,EMERALD,ER,22,305,,,205,Melbourne Water Corporation,Snowy Mountains Engineering Corporation,Fluor Construction for MMBW,Dam seperates Cardinia Reservoir from Aura Vale Lake,167 [e]
CARDINIA DIVERSION 2,145.408264160,-37.936882019,CARDINIA DIVERSION 2,1973,Trib Cardinia Creek,EMERALD,ER,25,165,,,,Melbourne Water Corporation,Melbourne & Metropolitan Board of Works,Melbourne & Metropolitan Board of Works ,Water quality diversion dam,200 [e]
CARDINIA DIVERSION 3,145.420913696,-37.938312530,CARDINIA DIVERSION 3,1973,Trib Cardinia Creek,EMERALD,ER,14,105,,,,Melbourne Water Corporation,Melbourne & Metropolitan Board of Works,Melbourne & Metropolitan Board of Works ,Water quality diversion dam,204 [e]
CARDINIA DIVERSION 4,145.439376831,-37.953369141,CARDINIA DIVERSION 4,1973,Trib Cardinia Creek,EMERALD,ER,18,85,,,,Melbourne Water Corporation,Melbourne & Metropolitan Board of Works,Melbourne & Metropolitan Board of Works ,Water quality diversion dam,202 [e]
CARDINIA DIVERSION 6,145.447265625,-37.951118469,CARDINIA DIVERSION 6,1973,Trib Cardinia Creek,EMERALD,ER,16,109,,,,Melbourne Water Corporation,Melbourne & Metropolitan Board of Works,Melbourne & Metropolitan Board of Works ,Water quality diversion dam,212 [e]
CARDINIA SADDLE 2,145.387659000,-37.956752000,CARDINIA RESERVOIR,1973,Off Stream,EMERALD,ER,10,323,,72625,12950,Melbourne Water Corporation,Snowy Mountains Engineering Corporation,Fluor Construction for MMBW,,164 [e]
CARDINIA SADDLE 3,145.385985000,-37.950086000,CARDINIA RESERVOIR,1973,Off Stream,EMERALD,ER,16,1219,,126660,12950,Melbourne Water Corporation,Snowy Mountains Engineering Corporation,Fluor Construction for MMBW,,161 [e]
CLOVER,147.218809000,-36.780890000,,1956,East Kiewa,WODONGA,CB,20,75,9,290,40,AGL,State Electricity Commission, Victoria ,State Electricity Commission, Victoria ,,567 [e]
CRUSOE,144.226091000,-36.819317000,,1873,Bendigo Ck,BENDIGO,TE,12,670,,1500,300,Coliban Water,Joseph Brady,Sandhurst Council,,287 [e]
DARTMOUTH,147.524242000,-36.558050000,LAKE DARTMOUTH,1979,Mitta Mitta,MITTA MITTA,ER,180,670,14100,4000000,63000,Murray Darling Basin Commission,State Rivers & Water Supply Commission, Victoria ,Thiess Bros Pty Ltd,,467 [e]
DARTMOUTH,147.523788452,-36.557788849,REGULATING DAM,1980,Mitta Mitta,WODONGA,PG,25,180,30,5200,90,AGL Hydro,State Electricity Commission of Victoria ,Thiess Bros Pty Ltd,Regulating dam for hydro-electric and irrigation releases,465 [e]
DEVILBEND,145.099998000,-38.277995000,,1965,Trib Balcombe Ck,MELBOURNE,TE,29,275,222,14600,2430,Melbourne Water Corporation,State Rivers & Water Supply Commission, Victoria ,State Rivers & Water Supply Commission, Victoria ,No longer used for water supply,69 [e]
DJERRIWARRH,144.523521000,-37.603365000,,1963,Djerriwarrh Ck,MELTON,TE,20,168,67,960,170,Western Water,J B K Ley,J Legge Constractors Pty Ltd,,214 [e]
EEL HOLE CREEK,146.365528000,-38.300984000,HAZELWOOD COOLING POND,1962,Eel Hole Creek,MORWELL,TE,21,1676,842,30840,4630,International Power Hazelwood ,State Electricity Commission of Victoria ,Lewis Construction Co Pty Ltd,Cooling water storage for thermal power station,78 [e]
EILDON,145.926719000,-37.222503000,LAKE EILDON,1956,Goulburn,EILDON,ER,83,983,10200,3390000,138320,Goulburn-Murray Water,State Rivers & Water Supply Commission, Victoria ,State Rivers & Water Supply Commission, Victoria ,Raised 1955, volume includes 16 bc in separate spillway,277 [e]
EPPALOCK,144.531841000,-36.850694000,EPPALOCK,1964,Campaspe,BENDIGO,ER,45,1041,816,312000,32300,Goulburn-Murray Water,State Rivers & Water Supply Commission, Victoria ,State Rivers & Water Supply Commission, Victoria ,,187 [e]
EVANSFORD,143.654405000,-37.275564000,,1887,Mccallums Creek,CLUNES,PG,17,76,,1620,286,Central Highlands Water,,,Raised 1940,343 [e]
EXPEDITION PASS,144.274317000,-37.052060000,,1869,Forest Creek,CASTLEMAINE,TE,18,240,59,550,70,Coliban Water,State Rivers & Water Supply Commission, Victoria ,State Rivers & Water Supply Commission, Victoria ,Reservoir volume presently 350 Ml due to siltation,379 [e]
FOSTER,146.226531982,-38.635631561,FOSTER,1997,Off Stream,FOSTER,TE,15,100,,262,46,South Gippsland Water,Fisher Stewart,,,74 [e]
FRANKSTON,145.129738000,-38.172184000,FRANKSTON RESERVOIR,1920,Sweetwater Ck,MELBOURNE,TE,19,264,,680,100,Melbourne Water Corporation,State Rivers & Water Supply, Commission, Victoria ,State Rivers & Water Supply, Commission, Victoria ,Embankment remedial works in 2004,78 [e]
G. A. WATERHOUSE,145.641082764,-36.816284180,,1978,Mountain Hut Ck,EUROA,ER,17,212,60,250,50,Goulburn Valley Water,Gutteridge Haskins & Davey,Thompson Earthworks,,299 [e]
GLENMAGGIE,146.800089000,-37.904692000,,1927,Macalister,SALE,PG,37,295,77,190410,17600,Southern Rural Water,State Rivers & Water Supply Commission, Victoria ,State Rivers & Water Supply Commission, Victoria ,Raised 1958, gates added, stabilised using ground anchors, 1987,69 [e]
GONG GONG,143.933119000,-37.548108000,,1877,Fellmonger's Ck,BALLARAT,TE,30,278,170,1902,253,Central Highlands Water,C Bagge,Young & McGuigan,Spillway reconstructed 1965, spillway capacity under review,512 [e]
GOULBURN WEIR,145.128450000,-36.789182000,NAGAMBIE,1890,Goulburn,NAGAMBIE,PG,15,212,14,25000,11200,Goulburn-Murray Water,Victorian Water Supply Department ,Victorian Water Supply Department ,Ground anchors installed 1982, vertical slide gates replaced with radial gates, 1986,128 [e]
GREENVALE,144.900162000,-37.635067000,,1972,Yuroke Creek,MELBOURNE,TE,52,2500,6900,27500,1740,Melbourne Water Corporation,Melbourne & Metropolitan Board of Works ,Melbourne & Metropolitan Board of Works ,Main dam only,164 [e]
JACANA,144.906921387,-37.692962646,JACANA RETARDING BASIN,1967,Moonee Ponds,MELBOURNE,TE,16,260,64,2870,650,Melbourne Water Corporation,Melbourne & Metropolitan Board of Works,Melbourne & Metropolitan Board of Works,Retarding basin, has permanently open outlet of 60 m3/sec,64 [e]
JOHNS HILL,145.419570923,-37.914756775,,1981,Off Stream,MENZIES CK,TE,27,420,185,360,35,Melbourne Water Corporation,Gutteridge, Haskins & Davey,Roche Bros Pty Ltd,,392 [e]
JUNCTION,147.224700928,-36.799194336,,1945,East Kiewa,WODONGA,CB,26,122,15,1480,120,AGL,State Electricity Commission, Victoria ,State Electricity Commission, Victoria ,,666 [e]
KELYNACK,145.082424000,-37.676093000,,1965,Trib Plenty River,BUNDOORA,,35,200,,150,,Parks Victoria,,,,93 [e]
KORUMBURRA NO 1,145.815719605,-38.412265778,COALITION CREEK,1896,Coalition Creek,KORUMBURRA,TE,13,230,,237,46,South Gippsland Water,,,Raised by 0.5m 1924,256 [e]
KORUMBURRA NO 3,145.810699463,-38.395195007,BELLVIEW CREEK,1958,Bellview Creek,KORUMBURRA,TE,16,100,38,502,80,South Gippsland Water,Scott Furphy,A D Hillgrove,,184 [e]
KORWEINGUBOORA,144.149487000,-37.509692000,,1910,E Morabool,BALLAN,TE/ER,13,533,84,2091,610,Barwon Water,Victorian Water Supply Department ,Alexander Lynch,,585 [e]
LAANECOORIE,143.891866000,-36.833994000,,1891,Loddon,MARYBOROUGH,TE/PG,22,399,,8000,4880,Goulburn-Murray Water,,,Spillway extensions 1909, raised 1935,163 [e]
LANCE CREEK,145.679097000,-38.509524000,,1911,Lance Ceek,WONTHAGGI,TE,21,480,86,4600,820,South Gippsland Water,J & H Coane,J & H Coane,Raised 4m in 1986, volume content refers to enlargement only,73 [e]
LAURISTON,144.380018000,-37.253449000,,1941,Coliban  ,KYNETON,CB/ER,33,244,42,20000,2080,Coliban Water,State Rivers & Water Supply Commission, Victoria ,State Rivers & Water Supply Commission, Victoria ,Raised 1949, secondary embankment 7m high and 197 long, includes 17 (TE) and ER in abutment sections,480 [e]
LEONGATHA NO 3,145.909499000,-38.411546000,HYLAND,1960,Ruby Creek,LEONGATHA,TE,20,100,75,1159,101,South Gippsland Water,Scott & Furphy,Thiess Bros (VIC) Pty Ltd,,184 [e]
LEONGATHA NO 4,145.897880000,-38.404101000,WESTERN,1981,Ruby Creek,LEONGATHA,TE,23,118,119,1137,150,South Gippsland Water,Camp Scott & Furphy,Statewide Earthmoving,,197 [e]
LERDERDERG WEIR,144.405746460,-37.578670502,,1980,Lerderderg,BACCHUS MARSH,PG,14,78,2,60,,Southern Rural Water,State Rivers & Water Supply Commission, Victoria ,State Rivers & Water Supply Commission, Victoria ,Diversion of stream flow only, via tunnel(s) to Merrimu. ,224 [e]
LOOMBAH,146.219680000,-36.720371000,,1946,Ryan's Creek,BENALLA,TE,14,170,34,677,160,North East Water,Garlick & Stewart,Snell & Handley,,330 [e]
LOWER STONY CREEK,144.246352000,-37.852785000,,1873,Stony Creek,GEELONG,PG,16,69,4,630,105,Barwon Water,Victorian Water Supply Department ,,No longer used for water supply,267 [e]
LOY YANG 1,146.584854126,-38.264644623,HIGH LEVEL STORAGE,1980,Off Stream,TRARALGON,TE,46,630,1790,6230,600,Loy Yang Power,State Electricity Commission of Victoria ,Roche Bros/State Electricity Commission of Victoria ,Water supply for the cooling systems, fire protection and other miscellaneous activities in the power stations,145 [e]
LOY YANG 2,,,SETTLING POND,1980,Off Stream,TRARALGON,TE,17,1620,570,1800,230,Loy Yang Power,State Electricity Commission of Victoria ,Thiess Bros Pty Ltd/State Electricity Commission of Victoria ,Retention of surface runoff and cooling period for purge water from thermal power station
LOY YANG 3,146.595046997,-38.264568329,FIRE SERVICE RESERVOIR,1981,Off Stream,TRARALGON,TE,28,650,500,2300,300,Loy Yang Power,State Electricity Commission of Victoria ,Thiess Bros Pty Ltd/State Electricity Commission of Victoria ,Downstream embankment partially submerged in ash pond as Ash Pond immediately down stream.,145 [e]
LOY YANG 4,146.584854126,-38.262809753,ASH POND,1981,Off Stream,TRARALGON,TE,43,1400,3000,9800,600,Loy Yang Power,Thiess Bros Pty Ltd/State Electricity Commission of Victoria ,Thiess Bros Pty Ltd/State Electricity Commission of Victoria ,Storage for Power Station Ash(7800) and clarification pond for ash sluicing water and storage of excess saline water (2000)from Latrobe Valley Power Station prior to discharge to Ocean Outfall. Embankment modified in 1995 to increase capacity by 2800.,142 [e]
LYSTERFIELD,145.298009000,-37.970878000,,1934,Eumemmering Ck,MELBOURNE,TE,14,523,,4200,840,Parks Victoria,State Rivers & Water Supply Commission, Victoria ,State Rivers & Water Supply Commission, Victoria ,,61 [e]
MALMSBURY,144.379084000,-37.196151000,,1870,Coliban,KYNETON,TE,24,530,,18000,3010,Coliban Water,State Rivers & Water Supply, Commission, Victoria ,State Rivers & Water Supply, Commission, Victoria ,Raised 1887, gates added 1940, Outlet and Spillway remodelled in 1987,447 [e]
MAROONDAH,145.551338000,-37.641932000,MAROONDAH RESERVOIR,1927,Watts,MELBOURNE,PG,41,291,132,28200,2000,Melbourne Water Corporation,Melbourne & Metropolitan Board of Works ,Melbourne & Metropolitan Board of Works ,Spillway enlarged 1989, stabilised using ground anchors,127 [e]
MCCALL SAY,146.211848000,-36.788460000,,1974,Ryans Creek,BENALLA,TE,23,168,130,1100,400,North East Water,Garlick & Stewart,State Rivers & Water Supply Commission, Victoria ,Formerly Upper Ryan's Creek,474 [e]
MCCAY,144.297620000,-37.092114000,,1960,Green Creek,CASTLEMAINE,TE/ER,30,274,170,1400,200,Coliban Water,State Rivers & Water Supply Commission, Victoria,State Rivers & Water Supply Commission, Victoria ,,405 [e]
MELTON,144.570401000,-37.744326000,,1916,Wribee,BACCHUS MARSH,ER,35,181,,17000,2450,Southern Rural Water,State Rivers & Water Supply Commission, Victoria ,State Rivers & Water Supply Commission, Victoria ,Raised 1937, 1967. Gates removed and spillway modified 1990,79 [e]
MERRIMU,144.494623000,-37.633428000,,1969,Coimadai Ck,BACCHUS MARSH,ER,46,350,350,35000,3300,Southern Rural Water,State Rivers & Water Supply Commission, Victoria ,State Rivers & Water Supply Commission, Victoria ,Raising of 8.7m in 1987, spillway crest set to store 1 in 100 year flood volume,170 [e]
MOKOAN,146.020690918,-36.481159210,LAKE MOKOAN,1971,Winton Swamp,BENALLA,TE,11,7500,956,365000,78910,Goulburn-Murray Water,State Rivers & Water Supply Commission, Victoria ,G Abignano Pty Ltd,Off stream storage,165 [e]
MOONDARRA,146.387458000,-38.091691000,,1961,Tyers,MOE,ER,41,311,499,30400,2500,Gippsland Water,Latrobe Valley Water & Sewerage Board ,Thiess Bros (VIC) Pty Ltd,,159 [e]
MOORABOOL,144.085565000,-37.516296000,,1915,Wst Morabool,BALLARAT,TE,13,658,115,6740,1586,Central Highlands Water,JS Sherland,Starr & McLelland,Raised 1940, embankment length 658 incluudes spillway 51m.,603 [e]
MORWELL NO 3,146.413543701,-38.261096954,SETTLING POND,1967,Off Stream,MORWELL,TE,12,975,275,1130,95,Gippsland Water,State Electricity Commission of Victoria ,State Electricity Commission, Victoria ,Filled In,85 [e]
MT COLE,143.112289429,-37.178379059,,1903,Spring Creek,ARARAT,VA,28,132,,800,120,Grampians Water,,,Raised 1926, 5.2m, raised 4m by kinhill, 1986 ,260 [e]
NEWLYN,144.003038000,-37.406062000,,1871,Bullarook Creek,DAYLESFORD,TE,12,741,,3300,710,Goulburn-Murray Water,State Rivers & Water Supply, Commission, Victoria ,State Rivers & Water Supply, Commission, Victoria ,Raised 1961,533 [e]
NICHOLSON RIVER,,,,1976,Nicholson,BAIRNSDALE,PG,16,96,8,630,140,Not SRW,Garlick & Stewart,Jack Legge Contractors Pty Ltd
NILLAHCOOTIE,146.011090000,-36.855553000,LAKE NILLAHCOOTIE,1967,Broken,BENALLA,ER,34,884,298,40000,5320,Goulburn-Murray Water,State Rivers & Water Supply Commission, Victoria ,State Rivers & Water Supply Commission, Victoria ,,262 [e]
O'SHANNASSY,145.805376000,-37.675490000,O'SHANNASSY RESERVOIR,1928,O'Shannassy,MELBOURNE,TE,34,226,245,3100,270,Melbourne Water Corporation,Melbourne & Metropolitan Board of Works ,Melbourne & Metropolitan Board of Works ,Spillway enlarged and full supply level lowered in 1987,359 [e]
PINE GULLY,146.430459000,-38.181091000,,1962,Offstream,MORWELL,TE,17,203,84,470,74,Gippsland Water,Gippsland Water,Latrobe Valley Water & Sewerage Board,,78 [e]
PINE LAKE,142.333031000,-36.775192000,,1923,Offstream,HORSHAM,TE,15,3700,,64200,7340,Wimmera Mallee Water,State Rivers & Water Supply Commission, Victoria ,State Rivers & Water Supply Commission, Victoria ,,138 [e]
PYKES CREEK,144.296161000,-37.610696000,,1911,Pykes & Myers Cks,BALLAN,TE,39,443,,24000,2030,Southern Rural Water,State Rivers & Water Supply Commission, Victoria ,State Rivers & Water Supply Commission, Victoria ,Raised 1930,393 [e]
ROCKLANDS,141.959968000,-37.234617000,,1953,Glenelg,HAMILTON,PG/ER,24,490,69,348310,68500,Grampians Wimmera Mallee Water,State Rivers & Water Supply Commission, Victoria,State Rivers & Water Supply Commission, Victoria ,Volume includes 15 (er) and (te),189 [e]
ROCKY VALLEY,147.294624000,-36.873845000,,1959,East Kiewa,WODONGA,ER,32,518,459,28370,2650,AGL,State Electricity Commission, Victoria ,State Electricity Commission, Victoria ,,1594 [e]
ROSSLYNNE,144.569628000,-37.475207000,,1973,Jackson Creek,GISBORNE,ER,37,351,440,24500,1940,Southern Rural Water,State Rivers & Water Supply Commission, Victoria ,State Rivers & Water Supply Commission, Victoria ,Formerly Little Scotland,446 [e]
RUNNING CREEK,145.225326538,-37.533153534,RUNNING CREEK RESERVOIR,1966,Running Creek,HURSTBRIDGE,ER,18,110,38,280,25,Melbourne Water Corporation,Garlick & Stewart,Janus Constructions Pty Ltd,No longer used for water supply,211 [e]
SANDHURST,144.241712000,-36.844100000,,1984,Off Stream,BENDIGO,TE,26,860,725,2500,172,Coliban Water,Rural Water Commission, Victoria,Rural Water Commission, Jack Legge Constructors Pty Ltd,,329 [e]
SILVAN,145.405576000,-37.827887000,,1932,Stoneyford Ck,MELBOURNE,TE,40,650,1610,40580,3340,Melbourne Water Corporation,Melbourne & Metropolitan Board of Works ,Melbourne & Metropolitan Board of Works ,Rockfill placed on downstream face 1986,242 [e]
SPRING GULLY,144.282546000,-36.803100000,,1868,Spring Creek,BENDIGO,TE,18,512,,2500,450,Coliban Water,,,Raised 1929,275 [e]
STAWELL MINE WATER,142.808990478,-37.066177368,,1984,Off Stream,STAWELL,TE,17,800,200,700,67,Western Mining Corporation,Gutteridge, Haskins & Davey,,N°5 Dam,248 [e]
SUGARLOAF,145.291936000,-37.674310000,SUGARLOAF RESERVOIR,1980,Sugarloaf Creek,MELBOURNE,ER,89,1050,4700,99220,4450,Melbourne Water Corporation,Melbourne & Metropolitan Board of Works,Various Contractors for MMBW,,169 [e]
SUGARLOAF SADDLE 1,145.300112000,-37.680730000,SUGARLOAF RESERVOIR,1980,Trib Sugarloaf Creek,YARRA GLEN,ER,17,528,,49591,4450,Melbourne Water Corporation,Melbourne & Metropolitan Board of Works,Various Contractors for MMBW,,173 [e]
SUNDAY CREEK,145.120543000,-37.364214000,,1986,Sunday Creek,BROADFORD,ER,30,213,246,1700,230,Goulburn Valley Water,Van Hoof & Byrne P/L,I & L Nadenbousch,,373 [e]
SWINGLER,146.327291000,-37.709017000,THOMSON RESERVOIR,1977,Thomson,MOE,PG,18,144,15,400,40,Melbourne Water Corporation,Melbourne & Metropolitan Board of Works ,Citra Australia Ltd for MMBW,Decommissioned and innundated under Thomson reservoir,432 [e]
TANK HILL,142.677180000,-38.307324000,,1938,Crater Depression,WARRNAMBOOL,TE,19,213,,760,134,Wannon Water,State Rivers & Water Supply Commission, Victoria ,State Rivers & Water Supply Commission, Victoria ,Concrete core wall with puddle clay each side,95 [e]
TARAGO,145.936782000,-38.020559000,,1974,Tarago,WARRAGUL,ER,34,300,326,37570,3600,Melbourne Water Corporation,State Rivers & Water Supply Commission, Victoria ,State Rivers & Water Supply Commission, Victoria ,Raised 1974,153 [e]
TAYLOR'S LAKE,142.380323000,-36.761854000,,1923,Offstream,HORSHAM,TE,12,2200,,35770,7400,Wimmera Mallee Water,,,,141 [e]
THOMSON,146.400805000,-37.840970000,THOMSON RESERVOIR,1983,Thomson,MOE,ER,166,590,14170,1123090,22300,Melbourne Water Corporation,Snowy Mountains Engineering Corporation,Various Contractors for MMBW,Dam vol includes Saddle Dam,494 / 434 [e]
THOMSON SADDLE,146.395483000,-37.845647000,THOMSON RESERVOIR,1983,Off Stream,MOE,ER,36,580,14170,514872,22300,Melbourne Water Corporation,Snowy Mountains Engineering Corporation,Various Contractors for MMBW,Dam vol includes Main Dam,446 [e]
TULLAROOP,143.865924000,-37.092568000,,1959,Tullaroop Creek,MARYBOROUGH,TE/ER,41,1502,788,74000,7420,Goulburn-Murray Water,State Rivers & Water Supply Commission, Victoria,State Rivers & Water Supply Commission, Victoria ,Includes secondary embankment 9 m high & 1070 m long,219 [e]
UPPER COLIBAN,144.396658000,-37.285347000,,1903,Coliban,KYNETON,TE,30,280,204,37500,4000,Coliban Water,,Victorian Government,Bank raised 1917, siphonic spillway added 1925, spillway and outlet remodelled, embankment raised 1992,501 [e]
UPPER STONY CREEK NO 1,144.209375000,-37.819243000,,1870,Upper Stony Ck,GEELONG,TE,26,404,320,3443,450,Barwon Water,Victorian Water Supply Department ,Jonothan Chappell,Embankment partially failed on first filling, spillway lowered, dam raised 1916 to original level,350 [e]
UPPER YARRA,145.898459000,-37.674072000,UPPER YARRA RESERVOIR,1957,Yarra,MELBOURNE,TE,89,610,5660,204895,7500,Melbourne Water Corporation,Melbourne & Metropolitan Board of Works ,Melbourne & Metropolitan Board of Works ,,360 [e]
WARANGA,145.039186000,-36.550190000,WARANGA BASIN,1905,Offstream,TATURA,TE,12,,,411000,58480,Goulburn-Murray Water,State Rivers & Water Supply, Commission, Victoria ,State Rivers & Water Supply, Commission, Victoria ,,119 [e]
WARTOOK,142.437959000,-37.096881000,,1887,Mackenzie,STAWELL,TE/ER,11,1160,,29360,10000,Grampians Wimmera Mallee Water,,Wimmera Shire, Victoria,Raised 1.2 metres in 1890, d/s strengthening berm constructed 1999,442 [e]
WEST BARWON,143.722265000,-38.531952000,,1963,West Barwon,COLAC,TE/ER,43,352,642,21900,1760,Barwon Water,Geelong Waterworks & Sewerage Trust ,Utah (Aust) Ltd,,181 [e]
WEST GELLIBRAND,143.653643000,-38.599004000,,1972,West Gellibrand,COLAC,TE,23,165,118,2000,250,Barwon Water,Garlick & Stewart,Jack Legge Contractors Pty Ltd,,344 [e]
WHITE SWAN,143.923409000,-37.518840000,,1951,Off Stream,BALLARAT,TE,41,479,887,14107,1240,Central Highlands Water,Ballarat Water Commission,Ballarat Water Commission Dayal Singh,Includes secondary embankment 21m high and 363m long,525 [e]
WILLIAM HOVELL,146.390859000,-36.912684000,,1973,King ,WANGARATTA,TE/ER,35,414,355,13500,1130,Goulburn-Murray Water,State Rivers & Water Supply Commission, Victoria ,State Rivers & Water Supply Commission, Victoria ,,406 [e]
WILLIMIGONGON,144.600163000,-37.391087000,,1982,Willimigongon,MACEDON,TE,20,187,107,280,38,Central Highlands Water,Camp Scott & Furphy,Leech Earthmoving,,680 [e]
WITTS GULLY,146.317718506,-38.215686798,,1964,Herne's Creek,YALLOURN,TE,17,198,84,350,65,Truenergy Yallourn,Shift Manager Mine Operations,Roche Bros Pty Ltd,Fire fighting water supply. Was Hernes Ck Dam.,123 [e]
WURDEE BOLUC,144.051208496,-38.277587891,,1928,Off Stream,GEELONG,TE,11,8658,821,40140,5640,Barwon Water,Geelong District Water Board, Rural Water Commission, GHD ,JJ McDonald and Sons,Original construction by SR&WSC, raised in 1955 by Geelong Water Storage Trust, raised in 1991 by Geelong District Water Board,137 [e]
YALLOURN STORAGE,146.340117000,-38.169823000,LAKE NARRACAN,1961,Latrobe,YALLOURN,CB,21,118,8,8020,3425,Southern Rural Water,State Electricity Commission, Victoria ,Lewis Construction Co Pty Ltd,Cooling water storage for thermal power station,55 [e]
YALLOURN WEIR,146.355346680,-38.170997620,,1935,Latrobe,YALLOURN,PG,12,129,2,490,150,Southern Rural Water,State Electricity Commission, Victoria ,State Electricity Commission, Victoria ,Original weir destroyed by flood 1934, rebuilt 1935, provides cooling water for thermal power station,47 [e]
YAN YEAN,145.124760000,-37.563426000,,1857,Off Stream,MELBOURNE,TE,10,963,206,33085,5600,Melbourne Water Corporation,Victorian Water Supply Department ,Martindale & Steele,Embankment  remedial works in 2000,180 [e]
YARRAWONGA WEIR,145.998774000,-36.007243000,LAKE MULWALA,1939,Murray,YARRAWONGA,TE,22,489,126,117500,43900,Murray Darling Basin Commission,State Rivers & Water Supply Commission, Victoria ,State Rivers & Water Supply Commission, Victoria ,Includes 32 (bc),126 [e]

TAILINGS DAM 8,139.458800000,-20.771300000,,,Lena Creek,,TE,24,150,,29500,7800
WANGUMMA WEIR,141.407900000,-34.122100000,,,Murray,,BG,10,,,15,0