Subj : Problem with Binkley
To   : Bob Ackley
From : Richard Webb
Date : Tue Oct 19 2010 12:02 am

HI Bob,

On Mon 2038-Oct-18 16:31, Bob Ackley (1:300/3) wrote to All:

BA> BT2 version 2.6 running on OS/2 version 4.0 (no fixpacks).  Machine
BA> is a Compaq Deskpro.

BA> Binkley's outgoing window shows two packets awaiting delivery to
BA> 618:150/0 and 618:150/1 (the same place for those interested).
BA> Binkley connects to 618:150/1 just fine and receives traffic
BA> regularly - but it won't pass the outgoing packets up the line.  It
BA> used to work just fine and nothing has been changed.  Traffic for
Hmmm, a couple of thoughts.

USe the PickupAll verb in your binkley.cfg if not already.

And here's one to take a close look at, make sure you have
same session pwd defined for both akas of the 618:*/* node.


BA> 1:116/901 also shows in the pending outbound window when it's there,
BA> and it is sent every time that system connects.

BA> Binkley also shows a message 'No traffic for 618:150/0' in the log
BA> at at every connect,  even though there IS a packet ready and
BA> waiting to go there.

THose two suggestions are my main thoughts, especially if
you're doing emsi sessions, make sure your nodelist compiler stuffs same
session pwd in the nodelist for both systems.

Regards,
          Richard
--- timEd 1.10.y2k+
* Origin:  (1:116/901)