Three lower confidence interval estimation procedures for
system reliability of coherent systems with cyclic
components are developed and their accuracy measured
using Monte Carlo techniques. The procedures use either
the Poisson approximation to the Binomial distribution,
the lower Binomial confidence limit procedure, or a
modified procedure using the Poisson approximation to the
Binomial distribution to obtain an equation for the lower
confidence limit. The accuracy of the interval estimators
were evaluated using standard computer simulation methods
for series, parallel, series-parallel, and Wheatstone
Bridge systems. The method determined to be most accurate
can be combined with similar procedures for components
that have continuous failure times and applied to yield a
lower confidence interval procedures for the reliability
of coherent systems with cyclic and continuously
operating components.
Date Published: 2018-03-04 02:33:40
Identifier: DTIC_ADA242713
Item Size: 80341640
Language: english
Media Type: texts
# Topics
DTIC Archive; Covington, Valerie A ; ...
# Collections
dticarchive
additional_collections
# Uploaded by
@chris85
# Similar Items
View similar items
PHAROS
You are viewing proxied material from tilde.pink. The copyright of proxied material belongs to its original authors. Any comments or complaints in relation to proxied material should be directed to the original authors of the content concerned. Please see the disclaimer for more details.