Three lower confidence interval estimation procedures for | |
system reliability of coherent systems with cyclic | |
components are developed and their accuracy measured | |
using Monte Carlo techniques. The procedures use either | |
the Poisson approximation to the Binomial distribution, | |
the lower Binomial confidence limit procedure, or a | |
modified procedure using the Poisson approximation to the | |
Binomial distribution to obtain an equation for the lower | |
confidence limit. The accuracy of the interval estimators | |
were evaluated using standard computer simulation methods | |
for series, parallel, series-parallel, and Wheatstone | |
Bridge systems. The method determined to be most accurate | |
can be combined with similar procedures for components | |
that have continuous failure times and applied to yield a | |
lower confidence interval procedures for the reliability | |
of coherent systems with cyclic and continuously | |
operating components. | |